• Title/Summary/Keyword: School connection

Search Result 1,716, Processing Time 0.023 seconds

A Study on Teaching Continuous Probability Distribution in Terms of Mathematical Connection (수학적 연결성을 고려한 연속확률분포단원의 지도방안 연구)

  • Hwang, Suk-Geun;Yoon, Jeong-Ho
    • School Mathematics
    • /
    • v.13 no.3
    • /
    • pp.423-446
    • /
    • 2011
  • In school mathematics, concepts of definite integral and integration by substitution have mathematical connection with introduction of probability density function, expectation of continuous random variable, and standardization of normal distribution. However, we have difficulty in finding mathematical connection between integration and continuous probability distribution in the curriculum manual, 13 kinds of 'Basic Calculus and Statistics' and 10 kinds of 'Integration and Statistics' authorized textbooks, and activity books applied to the revised curriculum. Therefore, the purpose of this study is to provide a teaching method connected with mathematical concepts of integral in regard to three concepts in continuous probability distribution chapter-introduction of probability density function, expectation of continuous random variable, and standardization of normal distribution. To find mathematical connection between these three concepts and integral, we analyze a survey of student, the revised curriculum manual, authorized textbooks, and activity books as well as 13 domestic and 22 international statistics (or probability) books. Developed teaching method was applied to actual classes after discussion with a professional group. Through these steps, we propose the result by making suggestions to revise curriculum or change the contents of textbook.

  • PDF

Cyclic response and design procedure of a weak-axis cover-plate moment connection

  • Lu, Linfeng;Xu, Yinglu;Zheng, Huixiao;Lim, James B.P.
    • Steel and Composite Structures
    • /
    • v.26 no.3
    • /
    • pp.329-345
    • /
    • 2018
  • This paper systematically investigated the mechanical performance of the weak-axis cover-plate connection, including a beam end monotonic loading test and a column top cyclic loading test, and a series of parametric studies for exterior and interior joints under cyclic loading using a nonlinear finite element analysis program ABAQUS, focusing on the influences of the shape of top cover-plate, the length and thickness of the cover-plate, the thickness of the skin plate, and the steel material grade. Results showed that the strains at both edges of the beam flange were greater than the middle's, thus it is necessary to take some technical methods to ensure the construction quality of the beam flange groove weld. The plastic rotation of the exterior joint can satisfy the requirement of FEMA-267 (1995) of 0.03 rad, while only one side connection of interior joint satisfied ANSI/AISC 341-10 under the column top cyclic loading. Changing the shape or the thickness or the length of the cover-plate did not significantly affect the mechanical behaviors of frame joints no matter in exterior joints or interior joints. The length and thickness of the cover-plate recommended by FEMA 267 (1995) is also suitable to the weak-axis cover-plate joint. The minimum skin plate thickness and a design procedure for the weak-axis cover-plate connections were proposed finally.

Influence of UTLS Ozone on the QBO-MJO Connection: A Case Study Using the GloSea5 Model (상부 대류권-하부 성층권 오존이 성층권 준 2년주기 진동과 매든-줄리안 진동 상관성에 미치는 영향: GloSea5 이용 사례)

  • Oh, Jiyoung;Son, Seok-Woo;Back, Seung-Yoon
    • Atmosphere
    • /
    • v.32 no.3
    • /
    • pp.223-233
    • /
    • 2022
  • Recent studies have shown that Madden-Julian Oscillation (MJO) is modulated by Quasi-Biennial Oscillation (QBO) during the boreal winter; MJO becomes more active and predictable during the easterly phase of QBO (EQBO) than the westerly phase (WQBO). Despite growing evidences, climate models fail to capture the QBO-MJO connection. One of the possible reasons is a weak static stability change in the upper troposphere and lower stratosphere (UTLS) by neglecting QBO-induced ozone change in the model. Here, we investigate the possible impact of the ozone-radiative feedback in the tropical UTLS on the QBO-MJO connection by integrating the Global Seasonal Forecasting System 5 (GloSea5) model. A set of experiments is conducted by prescribing either the climatological ozone or the observed ozone at a given year for the EQBO-MJO event in January 2006. The realistic ozone improves the temperature simulation in the UTLS. However, its impacts on the MJO are not evident. The MJO phase and amplitude do not change much when the ozone is prescribed with observation. While it may suggest that the ozone-radiative feedback plays a rather minor role in the QBO-MJO connection, it could also result from model biases in UTLS temperature and not-well organized MJO in the model.

Punching performance of RC slab-column connections with inner steel truss

  • Shi, Qingxuan;Ma, Ge;Guo, Jiangran;Ma, Chenchen
    • Advances in concrete construction
    • /
    • v.14 no.3
    • /
    • pp.195-204
    • /
    • 2022
  • As a brittle failure mode, punching-shear failure can be widely found in traditional RC slab-column connections, which may lead to the entire collapse of a flat plate structure. In this paper, a novel RC slab-column connection with inner steel truss was proposed to enhance the punching strength. In the proposed connection, steel trusses, each of which was composed of four steel angles and a series of steel strips, were pre-assembled at the periphery of the column capital and behaved as transverse reinforcements. With the aim of exploring the punching behavior of this novel RC slab-column connection, a static punching test was conducted on two full-scaled RC slab specimens, and the crack patterns, failure modes, load-deflection and load-strain responses were thoroughly analyzed to explore the contribution of the applied inner steel trusses to the overall punching behavior. The test results indicated that all the test specimens suffered the typical punching-shear failure, and the higher punching strength and initial stiffness could be found in the specimen with inner steel trusses. The numerical models of tested specimens were analyzed in ABAQUS. These models were verified by comparing the results of the tests with the results of the analyzes, and subsequently the sensitivity of the punching capacity to different parameters was studied. Based on the test results, a modified critical shear crack theory, which could take the contribution of the steel trusses into account, was put forward to predict the punching strength of this novel RC slab-column connection, and the calculated results agreed well with the test results.

Ecological Linkage Assessment of Urban Park by Using Connection Components in Establishment Green Network (도시녹지네트워크 구축에서 연결요소를 활용한 도시공원의 생태적 연결 가능성 평가)

  • Kim, Mi-Ri;Sung, Hyun-Chan
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.17 no.6
    • /
    • pp.61-72
    • /
    • 2014
  • We implemented ecological linkage assessment, through the connection components of the urban forests, rivers and parks, for the ecological connection of the urban parks which are standing out as the core of the urban green networks, so as to suggest basic data to compare, evaluate and improve urban green networks, as a basic study for the evaluation of the ecological connectabilities between the cities. For the ecological linkage assessment, we analyzed to see if the urban parks of Goyang, Ansan and Yongin, which are the subject cities, are actually ecologically connected with forests and rivers, using distance and roads, which are physical connection elements, in consideration of the mobility of the wild animals, and greening ratios and impervious pavement ratios, which are ecological connectabilities in consideration of the ecological values. The overall result of the ecological linkage assessment the physical connection elements and the ecological connection elements shows that the ecological green network ratio through direct connection states is 36.62% in Goyang, 42.55% in Ansan and 64.00% in Yongin, respectively, giving the ecological connectability ratio of less than half, with the average urban ecological green network ration of 47.72%. The comparison result of the ecological connectabilities between the object cities employing the connection elements indicates that when you set up green networks, you should consider together the physical connection elements, such as the roads, which will lower the ecological connectabilities - rather than do it simply based on areas and distances - while the ecological connection elements with the forests and the streams should be reinforced, so that the ecological connectabilities of the urban parks may be enhanced.

A Cascaded D-STATCOM Integrated with a Distribution Transformer for Medium-voltage Reactive Power Compensation

  • Lei, Ertao;Yin, Xianggen;Chen, Yu;Lai, Jinmu
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.522-532
    • /
    • 2017
  • This paper presents a novel integrated structure for a cascaded distribution static compensator (D-STATCOM) and distribution transformer for medium-voltage reactive power compensation. The cascaded multilevel converter is connected to a system via a group of special designed taps on the primary windings of the Dyn11 connection distribution transformer. The three-phase winding taps are symmetrically arranged and the connection point voltage can be decreased to half of the line-to-line voltage at most. Thus, the voltage stress for the D-STATCOM is reduced and a compromise between the voltage rating and the current rating can be achieved. The spare capacity of the distribution transformer can also be fully used. The working mechanism is explained in detail and a modified control strategy is proposed for reactive power compensation. Finally, both simulation and scaled-down prototype experimental results are provided to verify the feasibility and effectiveness of the proposed connection structure and control strategy.

Study on flexural capacity of simply supported steel-concrete composite beam

  • Liu, Jing;Ding, Fa-xing;Liu, Xue-mei;Yu, Zhi-wu
    • Steel and Composite Structures
    • /
    • v.21 no.4
    • /
    • pp.829-847
    • /
    • 2016
  • This paper investigates the flexural capacity of simply supported steel-concrete composite I beam and box beam under positive bending moment through combined experimental and finite element (FE) modeling. 24 composite beams are included into the experiments and parameters including shear connection degree, transverse reinforcement ratio, section form of girder, diameter of stud and loading way are also considered and investigated. ABAQUS is employed to establish FE models to simulate the behavior of composite beams. The influences of a few key parameters, such as the shear connection degree, stud arrangement, stud diameter, beam length and loading way, on flexural capacity are discussed. In addition, three methods including GB standard, Eurocode 4, and Nie method are also used to estimate the flexural capacity of composite beams and also for comparison with experimental and numerical results. The results indicate that Nie method may provide a better estimation in comparison to other two standards.

Experimental and analytical behavior of stiffened angle joints

  • Wang, Peng;Pan, Jianrong;Wang, Zhan;Chen, Shizhe
    • Steel and Composite Structures
    • /
    • v.26 no.1
    • /
    • pp.67-78
    • /
    • 2018
  • The application of rib stiffeners is common on steel connections, with regard to the stiffened angle connection, experimental results about the influence of stiffeners under monotonic and cyclic loading are very limited. Consequently, this paper presents the experimental investigation on four types angle connections with or without stiffener under static loading and another four type stiffened angle connections subjected to cyclic loading. The static experimental result showed that the rib stiffener weld in tension zone of the connection greatly enhanced its initial rotational stiffness and flexural strength. While a stiffener was applied to the compression zone of the connection, it had not obvious influences on the initial rotational stiffness, but increased its flexural strength. The moment-rotation curves, skeleton curves, ductility, energy dissipation and rigidity were evaluated under cyclic loading. Stiffened top-and-seat angle connections behaved as semi-rigid and partial strength, and rotation of all stiffened angle connections exceeded 0.04rad. The failure modes between monotonic and cyclic loading test were completely different and indicated certain robustness.

A Study on Automatic Modeling of Pipelines Connection Using Point Cloud (포인트 클라우드를 이용한 파이프라인 연결 자동 모델링에 관한 연구)

  • Lee, Jae Won;Patil, Ashok Kumar;Holi, Pavitra;Chai, Young Ho
    • Korean Journal of Computational Design and Engineering
    • /
    • v.21 no.3
    • /
    • pp.341-352
    • /
    • 2016
  • Manual 3D pipeline modeling from LiDAR scanned point cloud data is laborious and time-consuming process. This paper presents a method to extract the pipe, elbow and branch information which is essential to the automatic modeling of the pipeline connection. The pipe geometry is estimated from the point cloud data through the Hough transform and the elbow position is calculated by the medial axis intersection for assembling the nearest pair of pipes. The branch is also created for a pair of pipe segments by estimating the virtual points on one pipe segment and checking for any feasible intersection with the other pipe's endpoint within the pre-defined range of distance. As a result of the automatic modeling, a complete 3D pipeline model is generated by connecting the extracted information of pipes, elbows and branches.

Flexural stiffness of steel-concrete composite beam under positive moment

  • Ding, Fa-Xing;Liu, Jing;Liu, Xue-Mei;Guo, Feng-Qi;Jiang, Li-Zhong
    • Steel and Composite Structures
    • /
    • v.20 no.6
    • /
    • pp.1369-1389
    • /
    • 2016
  • This paper investigates the flexural stiffness of simply supported steel-concrete composite I-beams under positive bending moment through combined experimental, numerical, and different standard methods. 14 composite beams are tested for experimental study and parameters including shear connection degree, transverse and longitudinal reinforcement ratios, loading way are also investigated. ABAQUS is employed to establish finite element (FE) models to simulate the flexural behavior of composite beams. The influences of a few key parameters, such as the shear connection degree, stud arrangement, stud diameter, beam length, loading way, on the flexural stiffness is also studied by parametric study. In addition, three widely used standard methods including GB, AISC, and British standards are used to estimate the flexural stiffness of the composite beams. The results are compared with the experimental and numerical results. The findings have provided comprehensive understanding of the flexural stiffness and the modelling of the composite beams. The results also indicate that GB 50017-2003 could provide better results in comparison to the other standards.