• 제목/요약/키워드: School Building Cases

검색결과 242건 처리시간 0.022초

도시지역의 통합운영학교 유형과 건축계획 연구 (A Study on the Categories and Architectural Design of the Unified Operation School in Urban Area)

  • 이화룡;동재욱;김홍민;박민근
    • 교육시설 논문지
    • /
    • 제25권4호
    • /
    • pp.3-9
    • /
    • 2018
  • In recent years, schools in the urban areas are also showing their interest in the integrated school and considering adapting the actual operation method. That is why decline of the school-age population is not limited to rural areas any more, and decreasing number of students in urban schools is raised as a social issue to reconsider the continuation of schools. To solve the problems of the small-scale schools in the urban area, the integrated school is being considered as an alternative. Furthermore, the newly built schools in the urban development areas are also planned as the integrated school. Accordingly, the purpose of this study is to examine the cases of integrated schools in urban area of developed countries and to analyze their architectural planning considerations in practice.

Semi-automatic Legal Ontology Construction based on Korean Language Sentence Patterns

  • Jo, Dae Woong;Kim, Myung Ho
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권6호
    • /
    • pp.69-77
    • /
    • 2017
  • The information related to legislation is massive, and it takes much time and effort to manually build the legislation ontology. Thus, studies on machine-based automated building methods are underway. However, the studies to automatically construct such systems focus on using TBox construction, and those based on automated ABox construction, which corresponds to instances, theoretical systems and data building cases, has not yet been sufficiently developed. Therefore, this paper suggests using a semi-automatic ABox construction method based on sentence patterns to automatically build the ontology for the legislation of the Republic of Korea. Precision and Recall experiments were conducted to further discuss the performance of the suggested method. These experiments provide a comparison between the manual classification, and the triples built by the machines of the legal information by assessing the corresponding numerical values.

BIM for Construction Quality Record

  • Son, Sang-Hyuk;Lee, Dong-Eun
    • 국제학술발표논문집
    • /
    • The 6th International Conference on Construction Engineering and Project Management
    • /
    • pp.252-254
    • /
    • 2015
  • Building Information Modeling (BIM) encourages effective information share and utilization among project participants during entire life cycle of facility. This paper presents a method that keeps track of the historical quality records involved in construction operations and facilitates using BIM. The method is coded into BIM based Quality Record Traceability (BIM-QRT) System that makes use of historical records obtained from database administrating construction operations. This study is of value to practitioners because the method makes clear the project participants' responsibility relative to the quality of each and every element of the facility. The main objective of this research is to develop an accurate, fully automated method for construction Quality Record Tracking by using a BIM along with construction operations data obtained by information technology. Test cases verify the usability and validity of the methods implemented in the system.

  • PDF

미군 시설공사 설계변경 요인과 영향에 대한 연구 (Analysis of Causes and Impact of Change Orders in the U.S. Military Construction Projects)

  • 박인성;김하림;이학주;김도형;민윤기;조훈희
    • 한국건축시공학회지
    • /
    • 제21권3호
    • /
    • pp.213-219
    • /
    • 2021
  • 미군 공사는 국내 공사와 설계기준과 수행절차 등이 상이하기때문에 설계변경의 원인과 영향도 등도 다른 양상을 보인다. 본 연구는 100억 이상 규모 총 24건의 미군공사에서 발생한 721건의 설계변경 자료와 164명의 미군공사참여자 설문을 바탕으로 미군공사의 설계변경 원인과 그 영향도를 분석하였다. 미군공사에서 중요한 설계변경 요인은 설계 오류에 의한 설계 관련 변경(348건, 48.3%), 발주자 요구(86건, 11.9%), 상이한 현장 상태(69건, 9.6%)로 밝혀졌다. 또한, 설계변경으로 인해 평균 6.56%의 공사비 증가와 계약공기 대비 21.1%의 공기연장이 발생하였다. 본 연구의 결과로 국내 건설사에는 군 시설의 접근성 및 제한성으로 인해 부족할 수 있는 미군공사의 설계변경 및 공사성과의 전반적 이해도를 향상을 기대한다. 이를 바탕으로 향후 미군시설공사의 발전적 방향을 제시할 수 있는 후속 연구를 제안한다.

건물 적용 유형별 공기식 BIPVT 유닛의 전기 및 열성능 비교에 관한 연구 (A Study on the Performance Comparisons of Air Type BIPVT Collector Applied on Roofs and Facades)

  • 강준구;김진희;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제30권5호
    • /
    • pp.56-62
    • /
    • 2010
  • The integration of PV modules into building facades or roof could raise their temperature that results in the reduction of PV system's electrical power generation. Hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. PV/thermal collectors, or more generally known as PVT collectors, are devices that operate simultaneously to convert solar energy from the sun into two other useful energies, namely, electricity and heat. This paper compares the experimental performance of BIPVT((Building-Integrated Photovoltaic Thermal) collectors that applied on building roof and facade. There are four different cases: a roof-integrated PVT type and a facade-integrated PVT type, the base models with an air gap between the PV module and the surface, and the improved models for each types with aluminum fins attached to the PV modules. The accumulated thermal energy of the roof-integrated type was 15.8% higher than the facade-integrated regardless of fin attachment. The accumulated electrical energy of the roof-integrated type was 7.6% higher, compared to that of the facade-integrated. The efficiency differences among the collectors may be due to the fact that the pins absorbed heat from the PV module and emitted it to air layer.

Investigation of surface pressures on CAARC tall building concerning effects of turbulence

  • Li, Yonggui;Yan, Jiahui;Chen, Xinzhong;Li, Qiusheng;Li, Yi
    • Wind and Structures
    • /
    • 제31권4호
    • /
    • pp.287-298
    • /
    • 2020
  • This paper presents an experimental investigation on the surface pressures on the CAARC standard tall building model concerning the effects of freestream turbulence. Two groups of incidence turbulence are generated in the wind tunnel experiment. The first group has an approximately constant turbulence intensity of 10.3% but different turbulence integral scale varying from 0.141 m to 0.599 m or from 0.93 to 5.88 in terms of scale ratio (turbulence integral scale to building dimension). The second group presents similar turbulence integral scale but different turbulence intensity ranging from 7.2% to 13.5%. The experimental results show that the mean pressure coefficients on about half of the axial length of the side faces near the leading edge slightly decrease as the turbulence integral scale ratio that is larger than 4.25 increases, but respond markedly to the changes in turbulence intensity. The root-mean-square (RMS) and peak pressure coefficients depend on both turbulence integral scale and intensity. The RMS pressure coefficients increase with turbulence integral scale and intensity. As the turbulence integral scale increases from 0.141 m to 0.599 m, the mean peak pressure coefficient increases by 7%, 20% and 32% at most on the windward, side faces and leeward of the building model, respectively. As the turbulence intensity increases from 7.2% to 13.5%, the mean value of peak pressure coefficient increases by 47%, 69% and 23% at most on windward, side faces and leeward, respectively. The values of cross-correlations of fluctuating pressures increase as the turbulence integral scale increases, but decrease as turbulence intensity increases in most cases.

대학본부시설의 계획을 위한 조사연구 (A Study on The Planning of The Administration Facilities in University Campus)

  • 박준수;서기영
    • 교육시설
    • /
    • 제3권3호
    • /
    • pp.5-13
    • /
    • 1996
  • The university administration building is one of the most important structure in campuses in terms of its functional roll providing all the institutional services and its symbolic value that represents the school. But we can still find many universities carrying on without administration buildings, And even though in the cases that have their own administration buildings, the architectural qualities of the buildings often can not meet the basic requirements for a worthwhile administration building. Because of its complex and complicated nature, planning and designing university administrative facilities are not an easy task to be successful. This study aims to provide the basic directions in designing university administration building through the survey of the facilities in the existing campuses.

  • PDF

태양전지를 활용한 노후 건축물 그린 리모델링 디자인 사례분석 연구 (Old building green remodeling design cases study analysis using solar cell)

  • 박지훈;남원석;장중식
    • 한국융합학회논문지
    • /
    • 제11권9호
    • /
    • pp.155-162
    • /
    • 2020
  • 본 연구는 파리기후변화협약 이후 전 세계적으로 각광받고 있는 태양전지를 활용한 노후 건축물 그린 리모델링 디자인의 국내외 사례 분석을 바탕으로 향후 진행할 태양전지를 활용한 그린 리모델링 디자인 제안의 긍정적인 측면과 시사점을 확인하고자 하였다. 연구의 방법으로는 문헌연구를 바탕으로 이론적 고찰을 진행하였고, 이후 국내외 태양전지를 활용한 그린 리모델링 디자인의 사례를 조사·분석하였다. 그 결과 플렉서블한 특징을 통한 시공의 용이성, 박막전지의 투명도와 색상의 조절을 통한 심미적 효과, 자유로운 사이즈 제작으로 재료 낭비가 적은 경제적 효과, 외관의 직접 부착을 통한 건물과의 조화로운 측면을 확인할 수 있었다. 이러한 점을 토대로 박막 태양전지를 그린 리모델링 디자인에 활용하여 올 수 있는 기대효과와 유효성을 제시하고, 향후 진행할 태양전지를 활용한 노후 건축물 그린 리모델링 디자인 제안에 대한 방향성과 참고 자료로 활용되기를 기대한다.

내, 외단열 공동주택의 축열체 위치 차이에 따른 동단위 연간 냉난방부하 비교평가 (Comparison of Annual Heating and Cooling Loads of Internally and Externally Insulated Apartment Buildings According to the Location of Thermal Mass)

  • 구보경;이병인;최두성;송승영
    • 한국태양에너지학회 논문집
    • /
    • 제30권1호
    • /
    • pp.42-49
    • /
    • 2010
  • The IIS(Internal Insulation System) is applied in most Korean apartment buildings which are the most common type of residential buildings. Consequently, there are many cases in which the layer of insulation is disconnected by the structural components at the wall-slab and wall-wall joints in the envelope. These joints become thermal bridges where the risk of heat loss increases. It is expected that the EIFS(External Insulation and Finish System) is the solution to this problem. In this study, annual heating and cooling loads of apartment buildings with IIS and EIFS were compared using Design Builder program in order to evaluate the thermal storage effect of EIFS where the concrete thermal mass is located inside of the insulation material. As results, the apartment building with EIFS could reduce annual heating and cooling loads by 2.4% and 4.1%, respectively.

Community-acquired Legionnaires' Disease in a Newly Constructed Apartment Building

  • Ryu, Sukhyun;Yang, Kyungho;Chun, Byung Chul
    • Journal of Preventive Medicine and Public Health
    • /
    • 제50권4호
    • /
    • pp.274-277
    • /
    • 2017
  • Objectives: Legionnaires' disease (LD) is a severe type of pneumonia caused by inhalation of aerosols contaminated with Legionella. On September 22, 2016, a single case of LD was reported from a newly built apartment building in Gyeonggi province. This article describes an epidemiologic investigation of LD and identification of the possible source of infection. Methods: To identify the source of LD, we interviewed the patient's husband using a questionnaire based on the Legionella management guidelines from the Korea Centers for Disease Control and Prevention. Water samples from the site were collected and analyzed. An epidemiological investigation of the residents and visitors in the apartment building was conducted for 14 days before the index patient's symptoms first appeared to 14 days after the implementation of environmental control measures. Results: Legionella pneumophila serogroup 1 was isolated from the heated-water samples from the patient's residence and the basement of the apartment complex. Thirty-two suspected cases were reported from the apartment building during the surveillance period, yet all were confirmed negative based on urinary antigen tests. Conclusions: The likely source of infection was the building's potable water, particularly heated water. Further study of effective monitoring systems in heated potable water should be considered.