• Title/Summary/Keyword: Scattering Points

검색결과 75건 처리시간 0.03초

Two-Dimensional Numerical Modeling and Simulation of Ultrasonic Testing

  • Yim, Hyun-June;Baek, Eun-Sol
    • 비파괴검사학회지
    • /
    • 제22권6호
    • /
    • pp.649-658
    • /
    • 2002
  • As an attempt to further improve the reliability and effectiveness of ultrasonic testing (UT), a two-dimensional numerical simulator of UT was developed. The simulator models the wave medium (or test object) using the mass-spring lattice model (MSLM) that consists of mass-points and springs. Some previous simulation results, obtained by using MSLM, are briefly reviewed in this paper, for propagation, reflection, and scattering of ultrasonic waves. Next, the models of transmitting and receiving piezoelectric transducers are introduced with some numerical results, which is a main focus of this paper. The UT simulator, established by combining the transducer models with the MSLM, was used to simulate many UT setups. In this paper, two simple setups are considered as examples, and their simulated A-scan signals are discussed. The potential of the MSLM, transducer models, and the UT simulator developed in this study to be used in the actual UT is confirmed.

Interleaving Phenomena of the North Pacific Intermediate Water in the Offshore Area of the Kuroshio

  • Yang, Sung-Kee;Lee, Byung-Gul
    • 한국환경과학회지
    • /
    • 제12권5호
    • /
    • pp.521-527
    • /
    • 2003
  • To study the intruded phenomena of North Pacific Ocean around Boso peninsular, water property distribution in the adjacent seas to Japan is studied using the hydrographic data obtained by Japan Maritime Agency and Japan Fisheries Agency from 1973 to 1996, The scattering of water type in T-5 diagram is relatively small in the Kuroshio Region. Both the envelopes of saline side and of fresh side of the scattered data points shifts gradually from saline side to fresh side as the observation Line moves from southwest to northeast. In mixed water region, the scattering of water type increases rapidly as the observation line moves north; the envelope of fresh cold side moves towards fresh cold side much faster than that of saline side. This suggests that the water does not advect along the salinity minimum layer, but the salinity minimum layer can be understood as a boundary of two different waters aligned vertically, We defined the typical water masses as the Oyashio Water and the Kuroshio Water. The water mass below the salinity minimum layer may be created by isopycnal mixing of these two water masses with a fixed mixing rate. While the water mass above the salinity minimum cannot be created simply by isopycnal mixing. The salinity minimum layer may be eroded from upper side due to active minxing processes in the surface layer, while the water of the salinity minimum layer moves gradually southward. This appears to give an explanation why the thermosteric anomaly value at salinity minimun decereases towards south.

농촌지역 건설폐기물 중간처리 사업장에서 발생하는 미세먼지의 발생 현황 및 인근 지역에 미치는 영향 연구 (A Study on the Status of Fine Dust Generated from Construction Waste Intermediate Treatment Plants in Rural Area and Its Impact on Neighboring Areas)

  • 장경필;박지선;김병윤
    • 한국농촌건축학회논문집
    • /
    • 제25권4호
    • /
    • pp.9-16
    • /
    • 2023
  • In this study, the status and characteristics of fine dust and its impact on neighboring areas were investigated to proactively respond to the government's environmental regulations expected in the future and to minimize the damage by the fine dust generated at construction waste intermediate treatment plants. In addition, since there are no such plants that can affect the surroundings with no houses or other waste treatment sites nearby, an independently located construction waste intermediate treatment plant was selected to compare the characteristics of fine dust with that from the construction waste intermediate treatment sites located in the downtown area. The conclusions of the study are as follows. (1) The measurement results of PM10 at 4 points in the plant showed that the location where the crushing facility was operating had an elevated level of fine dust at 80㎍/m3 on average and a maximum of 124㎍/m3, and the level rose to 110㎍/m3 at points where vehicles frequent. (2) The PM2.5 measurement results inside the plant showed that the average concentration of the reference point was 16㎍/m3 and the maximum value was 20㎍/m3, which was distributed within the management standard. (3) It was found that the average concentration of PM10 in the nearby area ranged from 28 to 38㎍/m3, which was similar to or lower than 36㎍/m3 of the reference point. Therefore, the concentration of the fine dust generated in the plant had a negligible effect on the increase in concentration of fine dust in nearby areas. (4) The heavy metal contents were measured from the filter paper collected from the plant. The PM10 was found to be about 14 to 26ng/m3, and PM 2.5 was 25 to 28ng/m3, which was the average of domestic atmospheric concentrations. (5) The SEM-EDX analysis results showed that the PM10 contained Si and O around 40% similarly for both. The SiO2, a component of silica occupied the most and C was present as CaCO3, which was assumed to be a limestone component. The remaining components included NaO, Al2O3, and CaO as trace oxides. (6) The SEM-EDX analysis results showed that the PM 2.5 contained 5 to 7% of Cl, which is a chlorine ion, and a small amount of K was detected at 2.51% in the sample from the shutdown plant.

다층 유전체위의 변하는 저항율을 가진 저항띠 격자구조에 의한 전자파 산란 해석 (Analysis of Electromagnetic Scattering by a Resistive Strip Grating with Tapered Resistivity on Dielectric Multilayers)

  • Uei-Joong Yoon
    • 한국전자파학회논문지
    • /
    • 제8권5호
    • /
    • pp.495-503
    • /
    • 1997
  • 본 논문에서는 3개의 유전체층 위의 변하는 저항율을 가진 저항띠 격자구조에 의한 E 분극 전자파 산란 문제 들은 Fourier-Galerkin 모멘트 법을 이용하여 저항띠의 변하는 저항율과 3개의 유전체층의 비유전율 및 두께에 대한 효과를 알기 위해 해석하였다. 유도되는 표면전류는 차수 $\alpha$=0과 $\beta$=1의 값을 가지는 직교다항식의 일종인 Jacobi-polynomial ${P^{(\chi,\beta)}}_p$(.)의 급수로 전개하였으며, 저항띠의 변하는 저항율은 한쪽 모서리에서는 0이고 다른 쪽 모서리로 가면서 유한한 값으로 선형적으로 변하는 것으로 가정하였다. 정규화된 반사 및 투과전력은 저항띠의 변하는 저항율과 유전체 층들의 비유전율 및 두께를 변화시켜 얻었다. 급변점들은 전파모드와 감쇠모드사이 에서 고차모드가 모드 전환펠 때 관측되었으며, 전반적으로 국부적인 최소점들은 유전체 충들의 비유전율이 증가함에 따라 격자주기가 작아지는 값에서 발생하였다. 변하는 저하율에 따른 정규화된 반사전력 및 투과전력의 패턴은 균일 저하율 및 완전도체 경우와 매우 다르다는 것이 주목된다. 본 논문의 제안된 방법은 변하는 저항율, 균일 저항율및 완전도체 띠들의 경우에 대한 산란문제들을 해결할 수 있다.

  • PDF

不規則 粗面에서 저입사각 후방산란에 관한 수치해석 (A Numerical Study of Low Grazing Angle Backscattering from Random Rough Surfaces)

  • Kwang-Yeol Yoon
    • 한국전자파학회논문지
    • /
    • 제13권6호
    • /
    • pp.590-598
    • /
    • 2002
  • 맥스웰방정식의 직접해인 FVTD(Finite Volume Time Domain)법을 이용하여, 저입사시의 불규칙 조면에서의 전자파 산란 문제를 수치해석 하였다. FVTD댑은 복잡한 구조의 전자파의 산란문제에 대해서 개발된 시간영역에 의한 수치해석법이며, 종래의 FDTD(Finite Difference Time Domain)법 보다 임의형태의 경계문제를 쉽게 다룰 수 있는 이점을 가지고 있다. 그러나 산란물체의 형태가 아주 복잡하고 정도를 문제삼을 경우 FVTD법에서는 셀 사이즈(cell size)를 충분히 세분화 할 필요가 있다. 그 경우 셀 사이즈에 의한 수치해의 수속성을 검토하고, 외삽법(extrapolation method)을 이용해서 간단하고 정확한 후방산란계수를 측정하는 방안을 제시했다. 더욱이 취급하는 편파의 상이를 특징짖는 레이다 단면적의 편파비에 대해서 입사각(grazing angle) 이 10도 이하의 해면 레이다의 실험결과와 비교하여, FVTD법의 수치계산 결과가 실측치와 잘 일치하는 결과를 제시했다.

New Finger-vein Recognition Method Based on Image Quality Assessment

  • Nguyen, Dat Tien;Park, Young Ho;Shin, Kwang Yong;Park, Kang Ryoung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제7권2호
    • /
    • pp.347-365
    • /
    • 2013
  • The performance of finger-vein recognition methods is limited by camera optical defocusing, the light-scattering effect of skin, and individual variations in the skin depth, density, and thickness of vascular patterns. Consequently, all of these factors may affect the image quality, but few studies have conducted quality assessments of finger-vein images. Therefore, we developed a new finger-vein recognition method based on image quality assessment. This research is novel compared with previous methods in four respects. First, the vertical cross-sectional profiles are extracted to detect the approximate positions of vein regions in a given finger-vein image. Second, the accurate positions of the vein regions are detected by checking the depth of the vein's profile using various depth thresholds. Third, the quality of the finger-vein image is measured by using the number of detected vein points in relation to the depth thresholds, which allows individual variations of vein density to be considered for quality assessment. Fourth, by assessing the quality of input finger-vein images, inferior-quality images are not used for recognition, thereby enhancing the accuracy of finger-vein recognition. Experiments confirmed that the performance of finger-vein recognition systems that incorporated the proposed quality assessment method was superior to that of previous methods.

Second-order Nonlinear Optical Properties of Amorphous Molecules Based on 5-(4-Diethylamino-benzylidene)-1,3-dimethyl-pyrimidine-2,4,6-trione

  • Lee, Seung-Mook;Rhee, Bum-Ku;Lee, Sang-Ho;Lee, Chul-Joo;Park, Ki-Hong
    • Journal of Photoscience
    • /
    • 제10권2호
    • /
    • pp.203-208
    • /
    • 2003
  • Two coupled molecules were successfully synthesized by condensation of amine-donor-substituted barbituric acid derivativies as nonlinear optical chromophores. A flexible spacer of the alkyl chain with different lengths of carbon chains (5 and 6 carbons) was introduced between two chromophores, which prevented crystallization and aggregation of molecules. Two coupled molecules (B-Cn-B, n=5, 6) had glass-transition temperatures on a second heating around 81 and 76$^{\circ}C$ without melting points, respectively. To explore the linear optical properties, thin-films were prepared and examined by a photometry method using Nd:YVO$_4$ CW laser. Also, microscopic and macroscopic nonlinear optical properties were measured by Hyper-Rayleigh Scattering (HRS) and the Maker Fringes method using Nd:YAG ps pulse laser, respectively. In spite of the moderate hyperpolarizabilities of coupled molecules, the second order NLO coefficient (d$\_$33/) was larger than the conventional Disperse Red 1 doped PMMA polymeric system.

  • PDF

방사와 투과를 이용한 층류확산화염내 매연입자의 온도 및 농도 측정 (Soot Temperature and Concentration Measurement Using Emission/Transmission Tomography in Laminar Diffusion Flame)

  • 송상종;박성호;김상수
    • 대한기계학회논문집
    • /
    • 제17권10호
    • /
    • pp.2563-2573
    • /
    • 1993
  • The measurements of monochromatic line-of-sight flame emission and light transmission in the same path having small spatial resolution were performed in an axisymmetric laminar propane $C_{3}H_{8}$ diffusion flame. The light wavelengthes of 632 nm, 800nm, 900nm were used. From these measurements, local point soot radiances (by Kirchhoff's law) and absorption coefficients were reconstructed by tomography. Thus local point soot temperatures and concentrations were obtained. The reconstructed soot temperatures and concentrations of local points have no differences between the case of visible range (632 nm) and the case of infrared range (800 nm and 900 nm). In these ranges, the scattering coefficient is much lower than the absorption coefficient. Soot mean temperature over the path also matches well with local soot temperature in outer region of the flame. Temperature measurement by thermocouple with different bead diameters $(222{\mu}m and 308{\mu}m)$ was carried in the same flame. Rapid insertion technique was used and radiation effect was considered. Radiation correction in the sooting region was carried out and the corrected result was in good agreement with the local soot temperature.

Numerical analysis of an offshore platform with large partial porous cylindrical members due to wave forces

  • Park, Min-Su;Kawano, Kenji;Nagata, Shuichi
    • Ocean Systems Engineering
    • /
    • 제1권4호
    • /
    • pp.337-353
    • /
    • 2011
  • In the present study, an offshore platform having large partial porous cylindrical members, which are composed of permeable and impermeable cylinders, is suggested. In order to calculate the wave force on large partial porous cylindrical members, the fluid domain is divided into three regions: a single exterior region, N inner regions and N beneath regions, and the scattering wave in each fluid region is expressed by an Eigen-function expansion method. Applying Darcy's law to the porous boundary condition, the effect of porosity is simplified. Wave excitation forces and wave run up on the structures are presented for various wave conditions. For the idealized three-dimensional platform having large partial porous cylindrical members, the dynamic response evaluations of the platform due to wave forces are carried out through the modal analysis. In order to examine the effects of soil-structure interaction, the substructure method is also applied. The displacement and bending stress at the selective nodal points of the structure are computed using various input parameters, such as the shear-wave velocity of soil, the wave height and the wave period. Applying the Monte Carlo Simulation (MCS) method, the reliability evaluations at critical structure members, which contained uncertainties caused by dynamic forces and structural properties, are examined by the reliability index with the results obtained from MCS.

A Lattice-Based Monte Carlo Evaluation of Canada Deuterium Uranium-6 Safety Parameters

  • Kim, Yonghee;Hartanto, Donny;Kim, Woosong
    • Nuclear Engineering and Technology
    • /
    • 제48권3호
    • /
    • pp.642-649
    • /
    • 2016
  • Important safety parameters such as the fuel temperature coefficient (FTC) and the power coefficient of reactivity (PCR) of the CANada Deuterium Uranium (CANDU-6) reactor have been evaluated using the Monte Carlo method. For accurate analysis of the parameters, the Doppler broadening rejection correction scheme was implemented in the MCNPX code to account for the thermal motion of the heavy uranium-238 nucleus in the neutron-U scattering reactions. In this work, a standard fuel lattice has been modeled and the fuel is depleted using MCNPX. The FTC value is evaluated for several burnup points including the mid-burnup representing a near-equilibrium core. The Doppler effect has been evaluated using several cross-section libraries such as ENDF/B-VI.8, ENDF/B-VII.0, JEFF-3.1.1, and JENDL-4.0. The PCR value is also evaluated at mid-burnup conditions to characterize the safety features of an equilibrium CANDU-6 reactor. To improve the reliability of the Monte Carlo calculations, we considered a huge number of neutron histories in this work and the standard deviation of the k-infinity values is only 0.5-1 pcm.