• Title/Summary/Keyword: Scattering Dust Construction Site

Search Result 13, Processing Time 0.022 seconds

A Study on the Actual Condition and Effect of Dust Scattering in Construction Field (건설현장에서 발생하는 비산먼지의 실태 및 영향에 관한 연구)

  • Yu, Hee-Jong;Han, Kyeong-Yeon;Kwak, Kwang-Soo;Kim, Jae-Soo;Yang, Keek-Yeong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.4
    • /
    • pp.109-115
    • /
    • 2004
  • Dust scattering is one of the major problem for the residents living nearby construction field with construction noise and vibration. The dust scattering may inflict a considerable damage to psychological, spiritual discomfort to neighboring peoples. Therefore, the trouble of residents living nearby construction field have been increasing. Nevertheless, in our country, adequate guidelines for the dust scattering are not yet established because of the lack of basic data and insufficient research works. In this point, this study has researched its level of damage by conducting of the interview-survey which utilizing of questionnaire-paper asking for those staffs and workers to answer in the construction field, in order to grasp the damage extent of the actual condition effect and response against scattering dust in construction field. As the result, the occurring rate of dust scattering was appeared high compare with other constructing processes, due to utilization of construction equipment that operating at the fundamental basic construction stage, and it was turned out that presently the proper countermeasure and training against scattering dust in the construction site is insufficient. As for the solution mean against that, it is considered that with the better operation of construction site such as the installation of facilities for occurrence-restraint of dust scattering, frequent sprinkling of water, use of thermostat-covers, as well as those methods to be minimized of the occurrence of dust scattering must be contrived through the education for an attention how to use of construction equipment and training at the site.

Survey on the Occurrence of Fine (Scatter) Dust at the Construction Site and the Effectiveness of Countermeasures (건축공사 현장의 미세(비산)먼지 발생현황과 대책별 효과에 관한 설문조사)

  • Han, Jae Goo;Kim, Young Hyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.299-300
    • /
    • 2021
  • In this study, a questionnaire survey was conducted on the occurrence of fine dust at the construction site and the effectiveness of countermeasures. Based on the results of the survey, it is intended to be used as basic data for establishing a method to reduce fine dust in construction sites.

  • PDF

Survey on the Occurrence of Scattering Dust at Construction Sites (건설현장의 비산먼지 발생실태에 관한 설문조사)

  • Han, Jae Goo;Kim, Young Hyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.210-211
    • /
    • 2020
  • In this study, a questionnaire survey on the occurrence status of fine dust in urban construction sites and the response level was conducted. Based on the results of the survey, it is intended to be used as basic data for establishing a method to reduce fine dust in construction sites.

  • PDF

A Fundamental study of Fine Dust Reduction of Dust Inhibitor using Water Soluble Polymer (수용성 폴리머를 사용한 비산먼지 방지제의 미세먼지 저감에 관한 기초적 연구)

  • Lim, Sung-Gyu;Cho, In-Seong;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.38-39
    • /
    • 2020
  • Since a lot of fugitive dust is generated at construction and civil engineering construction sites in Korea, the fine dust regulation at construction sites has been strengthened in accordance with the implementation of the Special Act on Fine Dust Reduction. In a construction site, water is generally sprayed to temporarily reduce the generation rate of scattered dust, but there is a problem that when water evaporates, it scatters again. In this study, the performance of a scattering dust inhibitor incorporating a polymer that stabilizes the ground and reduces the rate of scattering dust by forming a polymer film even when water evaporates using a polymer and a surfactant was evaluated.

  • PDF

A Study on the Correlation Analysis between the Daily Earthwork Volume and Fine Dust Concentration

  • Dong-Myeong, CHO;Ju-Yeon, LEE;Tae-Hwan, JEONG;Woo-Taeg, KWON
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 2023
  • Purpose: Fine dust is classified as a group 1 carcinogen and poses a significant environmental problem that urgently requires improvement to protect the environmental rights of citizens. Given the difficulty of implementing measures to reduce overseas sources of fine dust, it is essential to first devise specific measures to address domestic emission sources. As such, this study aims to analyze the correlation between earthwork volume control and fine dust concentration as preliminary management measures to reduce the impact of scattering dust at construction sites. Based on real-time air quality information, field management measures will be presented to mitigate the effects of dust emissions. Research design, data and methodology: As examples, we selected construction sites that had recently undergone small-scale environmental impact assessment consultations. The standard earthwork volume was classified into grades using 20% intervals, and we applied AERMOD to predict the weighted concentration of fine dust based on the earthwork volume class and analyzed its correlation. Results: The results of this study demonstrate a strong correlation between earthwork volume and fine dust concentration. By utilizing the correlation analysis between earthwork volume and fine dust concentration on-site, this finding can be utilized as an effective fine dust management plan. Conclusions: This involves determining the daily earthwork intensity based on real-time air quality information and implementing measures to reduce scattering dust.

A Study on the Field Application of particulate matter Measurement Instruments in Light Scattering Method (광산란법 미세먼지 계측기의 현장 적용성 평가에 관한 연구 )

  • Liu, Bao-lin;Lee, Chung-Won;Lim, Hyo-Jin;Tae, Sung-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.201-202
    • /
    • 2023
  • Now, there are many cases where materials are maintained at construction sites or standard construction prices are not in accordance with the applicable regulations, resulting in a lot of fine dust. Therefore, a particulate matter measurement system is applied not only to manage particulate matter at construction sites but also to reduce particulate matter .This study aims to evaluate the applicability of this particulate matter measurement system to the construction site through long-term measurement experiments using a light scattering method particulate matter measurement instrument at the construction site.

  • PDF

A Study on the Realization of Dust Damage Compensation Calculation for the Prevention of Dust Damage in Construction Site (공사장 먼지피해 예방을 위한 먼지피해 배상액 산정 현실화 방안 연구)

  • Kim, Jinho
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.2
    • /
    • pp.374-385
    • /
    • 2022
  • Purpose: Even if a damage is applied to the dust of the construction site containing the first-class carcinogen, it is dismissed or 5~30% of the amount of noise damage compensation is paid., Because of such loopholes, some construction companies are neglecting the dust management of the construction site, and the damage of the workers and the residents in the construction site continues. Method: The purpose of this study is to examine the problems of the calculation criteria of damage compensation amount of construction site dust, the measurement of dust concentration, the analysis of measurement data (the data of electric signboard measuring device by the mining scattering method), the prediction and evaluation methods such as modeling, and to suggest improvement measures. Result: It is found that it is impossible to calculate the amount of damages from dust damage in the construction site by calculating the current dust damage compensation amount and dust concentration modeling and measurement. Conclusion: It will receive an application for compensation for damage within the site where damage is expected (about 100m in the straight line and the boundary line of the site), and present a method of calculating the amount of compensation that differentially evaluates dust damage to the degree of dust management and compliance with dust-related legal standards.

A Study on the Tendency of Fugitive Dust for Environmental Maintenance at the Aggregate Unloading Site of Ready-mixed Concrete Plants (레미콘 플랜트의 골재하차장 환경 유지관리를 위한 비산먼지 발생 경향에 관한 연구)

  • Cho, Hyun-Woo;Shin, Hong-Chul;Chung, Yoon-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.5
    • /
    • pp.103-111
    • /
    • 2022
  • Fine dust can cause serious problems to human health, and fugitive dust generated at construction sites is one of the main sources of fine dust in Korea. However, monitoring of the amount of fugitive dust generated at the ready-mixed concrete plant site is not performed, and only passive monitoring methods are partially applied in the field. Since it is impossible to control fugitive dust after it is exposed to the air, it is very important to suppress the occurrence or to remove it immediately at the stage of occurrence. Therefore, after identifying the characteristics through real-time monitoring in the fugitive dust generation stage, systematic management is required for suppressing or removing scattering dust in the field. In this study, the scattering dust generation characteristics were analyzed by measuring the particle mass concentration(PMC) of Fugitive dust generated at the aggregate unloading site of the ready-mixed concrete plant in real-time.

Evaluation of the Location Efficiency of Fine Dust Shelters Considering Vulnerable Population in Seoul (취약계층을 고려한 미세먼지 쉼터 입지 효율성 평가)

  • Lim, Jae Kwon;Lee, Hye Kyung
    • Journal of KIBIM
    • /
    • v.12 no.4
    • /
    • pp.104-115
    • /
    • 2022
  • Fine Dust in Korea has been classified as a social disaster since 2019 due to continuous increase in concentration of Particulate Matter 10(PM 10) and PM 2.5. The fine dust issue has negative physical and mental impacts, especially on vulnerable population including children and the elderly. Seoul metropolitan government have installed fine dust shelters since 2019. However, there is a lack of research that evaluates spatiotemporal distribution of these facilities. Therefore, the first aim of this study is to find the relationship between PM levels and dust scattering construction sites, or air pollutant emission sites through in depth spatial analyses. The second purpose is to analyze the spatial distribution of PM shelters in Seoul, and to evaluate the location efficiency of them. Kernel density, krigging, and network analyses were conducted, and floating population was considered instead of census data for this research. The reults of network analysis based on the road system showed that Yangcheon-gu, Songpa-gu, Seongbuk-gu, and Dobong-gu were found to need additional fine dust shelters. Also, the results from analyzing the floating population that includes children and the elderly showed that Songpa-gu, Seodaemun-gu, Gangdong-gu, Seocho-gu, and Dongdaemun-gu need more placements of find dust shelters. The results of this study are expected to provide implications for urban planners to enhance find dust shelter placement in urban areas, and vulnerable population issues would be considered in many ways.

Environmental Maintenance Technology for Concrete Manufacturing Industry by Using an Automatic Fugitive Dust Reduction System (비산먼지 자동 저감시스템을 이용한 콘크리트 제조업 환경 유지관리 기술)

  • Hyun-Woo Cho;Yoon-Seok Chung;Deuk-Hyun Ryu;Yun-Yong Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.4
    • /
    • pp.70-77
    • /
    • 2023
  • Fine dust is a cause of serious ecological problems, and fugitive dust generated from construction sites is a major source of fine dust in Korea. However, at construction sites, including concrete manufacturing industry sites, measurements are rarely made at the fugitive dust generation stage, and passive removal methods are the majority. Therefore, in this study, a fugitive dust measurement method suitable for managing fugitive dust generated during aggregate unloading in the concrete manufacturing industry sites was selected. In addition, the purpose was to analyze the amount of fugitive dust reduction according to the operation of the reduction system by applying the automatic fugitive dust reduction system to the aggregate unloading site. As a result, the reliability of the light scattering method was secured through the comparative measurement of the beta-ray absorption method and the light scattering method, and the light scattering method correction coefficient was calculated and applied to the measured value of the fugitive dust particle mass concentration at the concrete manufacturing industry sites. In addition, the fugitive dust reduction rate according to the operation of the automatic fugitive dust reduction system was derived.