• Title/Summary/Keyword: Scattered X-ray

Search Result 149, Processing Time 0.027 seconds

Mineralogical, Micro-textural, and Geochemical Characteristics for the Carbonate Rocks of the Lower Makgol Formation in Seokgaejae Section (석개재 지역 하부 막골층 탄산염암의 광물조성, 미세구조 및 지화학적 특성)

  • Park, Chaewon;Kim, Ha;Song, Yungoo
    • Economic and Environmental Geology
    • /
    • v.51 no.4
    • /
    • pp.323-343
    • /
    • 2018
  • This study defines the mineralogical, micro-textural and geochemical characteristics for the carbonate rocks and discusses the fluids that have affected the depositional environment of the Lower Makgol Formation in Seokgaejae section. Based on analysis of X-ray Diffraction (XRD), Scanning Electron Microscope-Energy Dispersive X-ray Spectrometry (SEM-EDS), Electron Probe Micro Analyzer-Wavelength Dispersive X-ray Spectrometry (EPMA-WDS) and Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry (LA-ICP-MS), carbonate miorofacies in the basal and the lower members of the Makgol Formation are distinguished and classified into four types. Type 1 dolomite (xenotopic interlocking texture) and Type 2 dolomite (idiotopic interlocking texture) have relatively high Mg/Ca ratio, flat REE pattern, low Fe and Mn. Extensively interlocking textures in these dolomites indicate constant supply of Mg ion from hypersaline brine. Type 3 and Type 4 dolomite (scattered and loosely-aggregated texture) have relatively moderate Mg/Ca ratio, MREE enriched pattern, low to high Fe and Mn. These partial dolomitization indicate limited supply of Mg ion under the influx of meteoric water with seawater. Also, the evidence of Fe-bearing minerals, recrystallization and relatively high Fe and Mn in Type 4 indicates the influence of secondary diagenetic fluids under suboxic conditions. Integrating geochemical data with mineralogical and micro-textural evidence, the discrepancy between the basal and the lower members of the Makgol Formation indicates different sedimentary environment. It suggest that hypersaline brine have an influence on the basal member, while mixing meteoric water with seawater have an effect on the lower member of the Makgol Formation.

Effects of acid-treatment conditions on the surface properties of the RBM treated titanium implants (산-처리 조건이 RBM처리한 티타늄 임플란트의 표면 특성에 주는 영향)

  • Lee, Han-Ah;Seok, Soohwang;Lee, Sang-Hyeok;Lim, Bum-Soon
    • Korean Journal of Dental Materials
    • /
    • v.45 no.4
    • /
    • pp.257-274
    • /
    • 2018
  • The purpose of this study was to evaluate the effect of acid-treatment conditions on the surface properties of the RBM (Resorbable Blast Media) treated titanium. Disk typed cp-titanium specimens were prepared and RBM treatments was performed with calcium phosphate ceramic powder. Acid solution was mixed using HCl, $H_2SO_4$ and deionized water with 4 different volume fraction. The RBM treated titanium was acid treated with different acid solutions at 3 different temperatures and for 3 different periods. After acid-treatments, samples were cleaned with 1 % Solujet solution for 30 min and deionized water for 30 min using ultrasonic cleanser, then dried in the electrical oven ($37^{\circ}C$). Weight of samples before and after acid-treatment were measured using electric balance. Surface roughness was estimated using a confocal laser scanning microscopy, crystal phase in the surface of sample was analyzed using X-ray diffractometer. Surface morphology and components were evaluated using Scanning Electron Microscope (SEM) with Energy Dispersive X-ray spectroscopy (EDX) and X-ray Photoemission Spectroscopy (XPS). Values of the weight changes and surface roughness were statistically analyzed using Tukey-multiple comparison test (p=0.05). Weight change after acid treatments were significantly increased with increasing the concentration of $H_2SO_4$ and temperature of acid-solution. Acid-treatment conditions (concentration of $H_2SO_4$, temperature and time) did not produce consistent effects on the surface roughness, it showed the scattered results. From XRD analysis, formation of titanium hydrides in the titanium surface were observed in all specimens treated with acid-solutions. From XPS analysis, thin titanium oxide layer in the acid-treated specimens could be evaluated. Acid solution with $90^{\circ}C$ showed the strong effect on the titanium surface, it should be treated with caution to avoid the over-etching process.

Two Cases of Giant Cell Tumor of the Bone Diagnosed by Fine Needle Aspiration Cytology (골 거대세포종의 2예 세침 천자 세포학적 소견)

  • Myong, Na-Hye;Ha, Chang-Won;Cho, Kyung-Ja;Jang, Ja-June;Baek, Goo-Hyun;Lee, Soo-Yong
    • The Korean Journal of Cytopathology
    • /
    • v.1 no.1
    • /
    • pp.93-97
    • /
    • 1990
  • Two cases of giant cell tumor of bone diagnosed by fine needle aspiration cytology are described. Case 1 was a 28-year-old male who had pain sense for one year at the right distal thigh. His radiologic finding revealed a destructive cortical lesion with soft tissue extension at medial side of epiphysis of the distal femur. Case 2 was a 21-year-old female complaining pain at left distal forearm for eight months and showed a well-demarcated expansile osteolytic lesion with multiseptation, and cortical destruction at epiphysis and metaphysis of the left distal radius on the X-ray. Fine needle aspiration of each lesion was performed. The aspirate of the case 1 revealed moderate cellularity, which was composed of scattered giant cells of osteoclastic type and small round to oval monotonous stromal cells in large areas. Giant cells were evenly distributed in single or small groups and had irregular but abundant cytoplasms with 10 to 20 nuclei in the center. The nuclei showed ovoid shape, fine granular chromatin, and a small but conspicuous nucleolus. Stromal cells were dispersed in isolated pattern or sometimes aggregated in clusters and showed the same nuclei as those of giant cells and scanty cytoplasms. Comparing to case 1, case 2 had a more translucent abundant cytoplasm in the giant cells and more spindled stromal cells. All two cases revealed neither nuclear atypism nor increased abnormal mitoses In both giant and stromal cells, suggesting no evidence of malignancy. Thereafter the lesions were treated with excision and curettage, and histologically confirmed as giant cell tumors of the bone.

  • PDF

The role of EL2 in the infrared transmission images of defects in semi-insulating GaAs

  • Kang, Seong-Jun;Lee, Sung-Seok
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.6
    • /
    • pp.725-728
    • /
    • 2011
  • Infrared transmission images from GaAs semi insulating wafers were considered for years as directly related to the quantum absorption by electrons on fundamental states of deep centers, especially EL2. The satisfying correspondence of these images with the dislocations revealed by etching or X ray topography or infrared tomography led to the opinion that a strong concentration of EL2 centers was to be expected in the immediate vicinity of the dislocations. More recent work indicates that contrary to the expected behavior the photoqu$\acute{e}$nching of transmission images at T=80K does not appreciably change the image structure itself but more largely the uniform background level of absorption. Such investigations show that the transmission images of isolated dislocations (Indium doped materials) or cell structures of tangled dislocations (undoped materials) can be partly attributed to scattered light; similar operation at T=10K removes the dark features associated to EL2 but still preserves the skeleton of the pattern which is due to scattering. A result of the measurements is that dislocations must not be considered any longer as inexhaustive EL2 reservoirs. The lifetime of the photoqu$\acute{e}$nching mechanism is shown to vary differently for EL2 centers located close to the dislocations or in the matrix. In this paper we will develop the details of infrared image photoqu$\acute{e}$nching experiments in the vicinity of dislocations; undoped and In doped GaAs materials will be shown. These results will be discussed in the light of surface etching experiments.

Mineralogical Characteristics and Origins of Smectite in the Marine Sediment around South Shetland Islands, Antarctica (남극 사우스셰틀란드 해양퇴적물내 스멕타이트의 광물학적 특성과 기원)

  • 정기영;윤호일
    • Journal of the Mineralogical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.22-32
    • /
    • 2002
  • Mineral composition and chemistry of the clay minerals in the three cores from the continental shelves of South Shetland Islands (NCS09) and Anberse Island (GC98-2), and from the fjord of King George Island (A10-01) were determined by X-ray diffraction and electron microprobe analysis in search of the distributions and origin of the clay minerals in the Antarctic marine sediments. Smectite content is relatively high in NCS09 regardless of core depths (av. 8.3%), but low in GC98-2 (1.1%). In Al0-01, smectite content is higher in the upper section than in the lower section. Kaolinite was not detected from all the cores in this study Yellow to yellowish green clay granules were commonly scattered in the sediments of NCS09 cores. The clays contain 16.97% and 2.53% $Fe_2$$O_3$$K_2$O. Average structural formula of the clay indicates ferrian beidellite . The (Fe, K)-rich smectite of NSC09 must have been derived from relatively young basaltic volcanics altered by reaction with seawater near Shetland Islands by glacial erosion or eolian process related to volcanic eruption. GC98-2 nearer to Antarctic continent is very low in smectite content. In A10-01, the lower diamicton was deposited from the glacial erosion of smectite-free ancient volcanics in the interior of King George Island, while the upper section was derived from the smectite-bearing terrestrial debris and eolian materials after retreat of glaciers in Marian Cove and ice cover in Barton Peninsula. Thehigh K contents of smectites suggest the interstratification of illite and smectite layers, which might be observed by future TEM lattice fringe imaging.

The Selection Effect of Native Gold and Magnetite by Microwave-nitric Acid Leaching and Magnetic/hydro Separation (마이크로웨이브-질산용출과자력/수력선별에의한자연금및자철석의선별효과)

  • Lee, Jong-Ju;Park, Cheon-Young
    • Economic and Environmental Geology
    • /
    • v.53 no.2
    • /
    • pp.183-196
    • /
    • 2020
  • This study aimed to recover native gold from the concentrate using microwave-nitric acid leaching and magnetic/hydro separation experiments. The insoluble-residue was filtered from leaching solution through microwave-nitric acid leaching experiment. As a result of the atomic absorption spectrometer(AAS) analysis of the filtered leaching solution, it was discovered that Au content was not eluted at all and it was observed from the back scattered electron(BSE) image that native gold was liberated in the insoluble-residue. When magnetic/hydro separation experiments were applied for the insoluble-residue, magnetic and non magnetic minerals were separtated from insoluble-residue. Magnetite was recovered from the magnetic minerals and as a result of applying the hydro separation experiment again for the non-magnetic mineral, native gold was recovered. The native gold was identified through the X-ray diffraction(XRD) analysis and BSE image.

Measurement of the Spatial Scattering Dose by Opening, Closing Door and Installing Shielding : A Study on the Reduction of Exposure Dose in Radiography (문 개폐 여부와 차폐체 설치 유무에 따른 공간산란선량 측정 : X선 촬영 시 피폭선량 감소방안에 대한 연구)

  • Yoon, Hong-Joo;Lee, Yong-Ki;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.477-482
    • /
    • 2019
  • Recently, due to the increased use of medical radiation, the radiation exposure of radiation workers should be considered as well as medical exposure of patients. And it is recommended to close the door during radiography. however, In this study, when the door was inevitably opened for radiography, the proposed method was to install the shield as a method of reducing the exposure dose. And its efficiency was analyzed. In simple chest radiography, the measurement point was changed according to the measurement location. Dose rate were measured 10 times for each condition using a dosimeter. And the average value was derived. Using this, the change of dose according to the opening and closing of the door and the installation of the shield was analyzed. Using this, we compared and analyzed the dose change according to the door opening and closing and the installation of the shield, and significance was verified through the SPSS ver. 24. Depending on whether the door was opened or closed, 11,215.35%, 159.0%, 101.9% increased in front of the door in the consol room, behind the wall and behind the lead glass. Depending on the installing of the shield, the 49.2%, 29.6%, 19.9%, 30.6% decrease in front of the door in the examination and consol room, behind the wall and lead glass. In addition, statistical analysis was showed that there were significant differences in both the results according to whether the door was opened or closed and shielding(p<.05). Close the door during radiography. However, when the door should be opened, it was confirmed that the dose rate were reduced by installing the shield. Therefore, to optimize radiation protection, it is recommended to install shields when opening the door.

Effectiveness Evaluation of Scanogram Using Longbone Detector (Longbone 검출기를 이용한 Scanogram의 유효성 평가)

  • Jang, Su-han;Heo, Ji-eun
    • Journal of radiological science and technology
    • /
    • v.43 no.4
    • /
    • pp.235-242
    • /
    • 2020
  • Scanogram is that combine several practical images into one image to observation. So it is an important consideration in many clinical situation such as iliac measurement, leg alignment measurement and Scoliosis. Currently, scanogram examinations are mainly conducted for children and elderly patients. In this study, in order to apply the longbone detector to children or elderly patients who are difficult to cooperate with, we compared the longbone detector from D equipment with the G equipment discovery 656 Puls equipment in reproducibility of images, distribution of irradiation dose, scattering dose, irradiation time and image acquisition time. D equipment took more than twice as much time as G equipment. The scattered dose generated about 50% more G equipment than D equipment. In the whole spine scanogram and the measurement length of the lower leg, D equipment was also measured longer than G equipment. However, both methods did not show much difference from the CT scanogram, so there was no problem in measurement. The height of the thyroid radiation dose of G equipment was produced more radiation than D equipment. However, the longbone detector deviated from the x-ray center line relative to the tube rotation method, and was measured lower by the directionality of the measuring instrument, so that the error could not be corrected. In the conclusion of study, using the longbone detector is excellent for applying to children or elderly patients to reduce scattering dose. However, using CR may be useful to normal patients. Because, the image quality may deteriorate due to an imbalance of dose difference in thickness depending on the body part. So, it is useful to using a compensation filter or tube rotation method when we take a whole spine scanogram.

A Case of Papillary Adenocarcinoma Presenting with Multiple Cysts (다발성 낭성 유두상 폐선암 1예)

  • Chon, Su-Yeon;Kim, Yu-Jin;Kyung, Sun-Young;An, Chang-Hyeok;Lee, Sang-Pyo;Park, Jeong-Woong;Jeong, Sung-Hwan;Cho, Eun-Kyung;Sung, Yon-Mi;Kim, Na-Rae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.68 no.2
    • /
    • pp.93-96
    • /
    • 2010
  • A 23-year old woman was admitted to our hospital with hemoptysis. The chest X-ray showed reticulonodular opacity and multiple cysts throughout the entire lung field. The chest CT scan revealed numerous bilateral cysts with various sizes, some of them with thickened walls. An open lung wedge resection was performed. The resected specimen showed scattered small nodules, 0.3 to 0.6 cm in size. Microscopically, each nodule was composed of atypical glands with an occasional papillary architecture spreading to the alveolar septa, which were morphologically consistent with a papillary adenocarcinoma with a bronchioloalveolar carcinoma growth pattern. Immunochemically, the tumor cells were negative for the S-100 protein. The patient was diagnosed with an adenocarcinoma of the lung. A variety of diseases can produce or mimic multiple, thin-walled cysts in the lung. Lung cancer with multiple cysts is quite rare. Nevertheless, adenocarcinoma should be a diagnostic consideration. We report a case of a multiple cystic adenocarcinoma of the lung.

Analysis of Chemical Compounds of Gaseous and Particulate Pollutants from the Open Burning of Agricultural HDPE Film Waste

  • Kim, Tae-Han;Choi, Boo-Hun;Kook, Joongjin
    • Journal of People, Plants, and Environment
    • /
    • v.24 no.6
    • /
    • pp.585-593
    • /
    • 2021
  • Background and objective: Illegal open-air incineration, which is criticized as a leading source of air pollutants among agricultural activities, currently requires constant effort and attention. Countries around the world have been undertaking studies on the emission of heavy metal substances in fine dust discharged during the incineration process. A precise analytical method is required to examine the harmful effects of particulate pollutants on the human body. Methods: In order to simulate open-air incineration, the infrastructure needed for incineration tests complying with the United States Environmental Protection Agency (EPA) Method 5G was built, and a large-area analysis was conducted on particulate pollutants through automated scanning electron microscopy (SEM)-energy-dispersive X-ray spectroscopy (EDS). For the test specimen, high-density polyethylene (HDPE) waste collected by the DangJin Office located in Choongcheongnam-do was used. To increase the identifiability of the analyzed particles, the incineration experiment was conducted in an incinerator three times after dividing the film waste into 200 g specimens. Results: Among the metal particulate matters detected in the HDPE waste incineration test, transition metals included C (20.8-37.1 wt%) and O (33.7-37.9 wt%). As for other chemical matters, the analysis showed that metal particulate matters such as metalloids, alkali metals, alkaline earth metals, and transition metals reacted to C and C-O. Si, a representative metalloid, was detected at 14.8-20.8 wt%, showing the highest weight ratio except for C and O. Conclusion: In this study, the detection of metal chemicals in incinerated particulate matters was effectively confirmed through SEM-EDS. The results of this study verified that HDPE waste adsorbs metal chemicals originating from soil due to its own properties and deterioration, and that when incinerated, it emits particulate matters containing transition metals and other metals that contribute to the excessive production and reduction of reactive oxygen species.