• Title/Summary/Keyword: Scattered X-ray

Search Result 149, Processing Time 0.026 seconds

A Case of Pulmonary Alveolar Microlithiasis (폐포 미세 결석증 1예)

  • Lee, Bu-Hyun;Kang, Byung-Soo;Min, Joo-Won;Park, Sang-Joon;Kim, Tae-Ho;Chung, Jae-Ho;Park, Chan-Sub
    • Tuberculosis and Respiratory Diseases
    • /
    • v.71 no.1
    • /
    • pp.55-58
    • /
    • 2011
  • Pulmonary alveolar microlithiasis is a rare disease of unknown etiology that is characterized by the presence of calcific concentrations in the alveolar spaces. The radiographic appearance is pathognomonic. Plain chest radiographs show a white lung or sandstorm lung consisting of fine sand like microcalcifications diffusely scattered throughout both lungs with a higher density at the lung bases. We now report the case of a 67-year-old male whose diagnosis was based on characteristic findings on a chest X-ray and a high-resolution computed tomography scan.

Simulation study of dust-scattered Far-Ultraviolet emission in the Orion-Eridanus Superbubble

  • Jo, Young-Soo;Min, Kyoung-Wook;Lim, Tae-Ho;Seon, Kwang-Il
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.98.1-98.1
    • /
    • 2012
  • We present the results of dust scattering simulations carried out for the Orion-Eridanus Superbubble region by comparing them with observations made in the far-ultraviolet. The albedo and the phase function asymmetry factor (g-factor) of interstellar grains were estimated, as were the distance and thickness of the dust layers. The results are as follows: [0.43]_(-0.04)^(+0.02) for the albedo and [0.43]_(-0.2)^(+0.2) for the g-factor, in good agreement with previous determinations and theoretical predictions. The distance of the assumed single dust layer, modeled for the Orion Molecular Cloud Complex, was estimated to be ~110 pc, and the thickness ranged from ~130 at the core to ~50 pc at the boundary for the region of present interest, implying that the dust cloud is located in front of the superbubble. The simulation result also indicates that a thin (~10 pc) dust shell surrounds the inner X-ray cavities of hot gas at a distance of ~70-90 pc.

  • PDF

The Imaging Anatomical Consideration about Effects of Respiratory Disease on the Breath Control and Resonance in Vocal Technique (발성기법중 호흡기 질환이 호흡조절과 공명에 미치는 영향에 관한 영상해부학적 고찰)

  • Lee, Dong-Myoung
    • Journal of radiological science and technology
    • /
    • v.24 no.2
    • /
    • pp.41-47
    • /
    • 2001
  • This study was undertaken to examine the differences between normal vocal technique and abnormal vocal technique because of diseases in respiratory system(emphysema). The breath control for vocalizing with diaphragmatic respiration must be sustained clearly. But if there is an abnormality in lung(emphysema), it is not sustained to hold diaphragmatic respiration when we sing. In order to examine the differences of the width in diaphragmatic respiration among professional singer's case, non professional case and the case of respiratory disturbance, Shimadzu X-ray remote control TV system was used. The results obtained were summerized as follows: When we vocalize, breath control is very important not only to sustain a resonance but also to form focus for being scattered to cranial resonance. We must know the differences between normal and abnormal diaphrogmatic respiration in order to teach vocal technique right. professional singer's vocal technique with Piaphragmatic respiration was better than that compared with non professional case and respiratory disturbance. Non professional case was very similar to the case of respiratory disturvance in diaphragmatic respiration until 10 sec. after full inhalation, but diaphragmatic respiration in the case of 20 sec. after full inhalation was very different.

  • PDF

Investigation of Initial Formation of Aluminum Nitride Films by Single Precursor Organometallic Chemical Vapor Deposition of$[Me_{2}Al(\mu-NHR)]_{2}\;(R=^{i}Pr,\;^{t}Bu)$

  • Sung Myung Mo;Jung Hyun Dam;Lee June-Key;Kim Sehun;Park Joon T.;Kim Yunsoo
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.1
    • /
    • pp.79-83
    • /
    • 1994
  • The organometallic chemical vapor deposition of single precursors, $[Me_2Al({\mu}-NHR)]_2\;(R=^iPr,\;^tBu)$, for alumininum nitride thin films has been investigated to evaluate their poroperties as potential precursors. In chemical vapor deposition processes the gas phase products scattered from a Ni(100) substrate were analyzed by mass spectrometry and the deposited films were characterized by X-ray photoelectron spectroscopy (XPS). The optimum temperatures for the formation of AlN films have been found to be between 700 K and 800 K. Carbon contamination of the films seems to be attributed mainly to the methyl groups bonded to the aluminum atoms. It is apparent that $^tBu$ group is better than $^iPr$ group as a substituent on the nitrogen atom of the single precursors for the AlN thin film formation.

The Effects of Image Quality due to Scattering X-ray according to increasing Patient Thickness (피사체 두께에 따른 산란선 발생이 화질에 미치는 영향)

  • Park, Ji-Koon;Yang, Sung-Woo;Jun, Jae-Hoon;Cho, Su-Yeon;Kim, Kyo-Tae;Heo, Ye-Ji;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.671-677
    • /
    • 2017
  • In this study, scattering factors affecting the quality of medical images were quantitatively analyzed and investigated. MCNPX simulation was conducted by using ANSI phantom, made of tissue equivalent materials, to calculate the scattering ratio occurred by the increase of the object thickness. Then, the result of the simulation was compared with the result of actual radiation measurement. In addition, we evaluated the image quality by the RMS evaluation, RSD and NPS analysis using X-ray images acquired with increasing object thickness. Furthermore, the scattering ratio was analyzed by increasing the thickness of acrylic phantom on chest phantom. The result showed that the scattering ratio was increased to 57.2%, 62.4%, and 66.8% from 48.9%, respectively, when the acrylic phantom thickness was increased by 1 inch from 6.1 inches. The results of MCNPX simulation and the actual measured scattering dose showed similar results. Also, as a result of RMS measurement from acquired x-ray images, the standard deviation decreased as the object thickness increased. However, in the RSD analysis considering the average incident dose, the results were increased from 0.028 to 0.039, 0.051, 0.062 as the acrylic phantom thickness was increased from 6.1 inches to 7.1 inch, 8.1 inch, and 9.1 inch, respectively. It can be seen that the increase of the scattering effect due to the increase of the object thickness reduces the SNR. Also, the NPS results obtained by measuring scattered radiation incident on the detector resulted in the increase of the noise as the object thickness increased.

Evaluation of the Space Scattered Dose According to the Position of the Radiation Workers in Mammography Room (유방촬영 시 방사선관계종사자의 위치에 따른 공간선량평가)

  • Lee, Dong-Yeon;Lee, Jin-Soo
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.297-303
    • /
    • 2016
  • This study was conducted to evaluate the dose of the space to the controller located within the mammography room conducted a research on ways to the reduction exposure to the radiation workers. Results, the dose of 6.18 mGy/year was measured when there is no difference in the hilar area of the controller position, the dose of 2.35E-11 mGy/year was measured when installing the Shielding door. In addition, when the direction of the X-ray tube anode be heading this direction controller, low average level measured was 0.30 mGy/year. Based on this study, the mammography should be considered when installing the anode and cathod directions. And, by installing the shielding door, it must be able to completely separate shooting space and control room. This is the best way radiation protection method in radiation workers.

Evaluation of Image Quality for Scattered X-rays using in Digital Radiography (디지털방사선영상에서 산란선의 영상특성 평가)

  • Kim, Hansol;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.395-403
    • /
    • 2022
  • Flat-panel detector (FPD) used in digital radiographic imaging systems was used to perform a quantitative power spectrum evaluation as a result of the thickness change of polymethyl methacrylate (PMMA), a tissue equivalent. As the PMMA thickness increases with the resolution-chart phantom image, the effect of the scattering line increases, indicating that the modulation characteristics decrease, and the image is bright. The results show that the noise of the image increases, and noise-power spectral images are obtained by Fourier transform to confirm by spatial frequency. Thus, it can be verified that the PMMA thickness and noise are proportional through the result of evaluating the change of resolution characteristics and representing the 2D noise-power spectrum as one-dimensional values by evaluating the change of scattering line with MTF as the PMMA thickness increases in the image.

Morphological Changes of Mouse Ovary by X-Ray Irradiation (방사선 조사선량에 따른 생쥐 난소의 형태학적 변화)

  • Yoon, Chul-Ho;Choi, Jong-Woon;Yoon, Surk-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.4
    • /
    • pp.140-156
    • /
    • 2007
  • This research was performed to investigate the morphological changes of folliculus ovary according to the radiation dose. The whole body radiation of 200 cGy, 400 cGy, and 600 cGy was given to the each groups of 5 months-aged female mouse. Various staining methods used in this research are: Hematosylin-Eosin method, and immunohistochemistrical methods using BrdU, TUNEL, p53, p21, PCNA and inhibin. The minute structural changes of folliculus ovary were observed through an electron microscope with high magnification. The morphological changes of growing folliculus ovary became distinct as the dose of X-rays increased. Especially, the nuclei of granular cells showed manifest condensation and the changes of the transparent zone were distinct. As a result of histochemical reaction according to Masson's trichrome method and reticular fiber method, the changed granular cells, the deformed basilar membrane of folliculus ovary and the abnormal arrangement of the reticular fiber were observed. In the reaction of BrdU, the granular cells of normal folliculus ovary with positive reaction rapidly decreased according to the increase of the dose of X-rays. In TUNEL study, granular cells showing positive reaction in retarded folliculus ovary were expanded to growing folliculus ovary and primordial folliculus ovary according to the increase of the dose of X-rays. In case of 600 cGy of X-rays, oocyte underwent apoptosis. In p53 immunohistochemistry, p53 manifested to be stronger as the dose of X-rays increased. p53 reactivity was manifested distinctively in all cells comprising folliculus ovary following irradiation of 600 cGy. p21 was manifested in granular cells of folliculus ovary and showed very positive reaction around follicular antrum according to the increase of the dose of X-rays. In PCNA, positive reaction was manifested in growing folliculus ovary, mature folliculus ovary and primordial folliculus ovary, but the extent of the reaction decreased as the dose of the X-rays decreased. The finding that the reaction of granular cells around folliculus ovary was stronger than that near follicular membrane indicates that what was damaged first by X-ray was the cells near folliculus ovary and follicular antrum. The reactivity of $inhibin-{\alpha}$ showed difference according to the growing stage of folliculus ovary: $inhibin-{\alpha}$ showed the most strong reaction in mature folliculus ovary with follicular antrum. There was strong reaction in granular cells around follicular membrane but $inhibin-{\alpha}$ did not occur at all in theca cells comprising follicular membrane. $Inhibin-{\alpha}$ in ovary tissue exposed to 400 cGy of X-rays was manifested more strongly than in ovary tissue exposed to 600 cGy of X-rays, which was related to the phenomenon that granular cells of mature folliculus ovary underwent necrosis or apoptosis increasingly due to X-rays. In an electron microscope with high magnification, nuclei and protoplasm of granular cells in growing folliculus ovary abruptly underwent minute structural changes according to the increase of dose of X-rays. Cell residue, by-product of cell decease, neutrophil and macrophage around follicular antrum were observed. The minute structural changes in granular cells showed typical characteristics of apoptosis: the increase of electronic density due to nuclear condensation, fragmentation of nuclei and atrophy of protoplasm. Necrosis of cells was identified but it was not so remarkable. Macrophage with apoptotic bodies was scattered. Proportional to the radiation dose, we found that the generation of heterogeneous substance of normal ovary texture's follicular fluid, the emergence of dyeing characteristic in the basilar membrane of folicle, the generation of apoptosis, and the transformation of macrophages, etc. From this results, we can infer the possible radiation hazard on the ovary of cervix cancer patient with radiation therapy.

The Variation of Surface Dose by Beam Spoiler in 10 MV Photon Beam from Linear Accelerator (선형가속기 10 MV 광자선에서 산란판(Beam Spoiler) 사용 시 표면선량 변화)

  • Bae, Seong-Cheol;Kim, Jun-Ho;Lee, Choul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • Purpose: The purpose of this study is to find a optimal beam spoiler condition on the dose distribution near the surface, when treating a squamous cell carcinoma of the head and neck and a lymphatic region with 10 MV photon beam. The use of a optimal spoiler allows elivering high dose to a superficial tumor volume, while maintaining the skin-sparing effect in the area between the surface to the depth of 0.4 cm. Materials and Methods: The lucite beam spoiler, which were a tissue equivalent, were made and placed between the surface and the photon collimators of linear accelerator. The surface-dose, the dose at the depth of 0.4 cm, and the maximum dose at the dmax were measured with a parallel-plate ionization chamber for $5{\times}5cm\;to\;30{\times}30cm^2$ field sizes using lucite spoilers with different thicknesses at varying skin-to-spoiler separation (SSS). In the same condition, the dose was measured with bolus and compared with beam spoiler. Results: The spoiler increased the surface and build-up dose and shifted the depth of maximum dose toward the surface. With a 10 MV x-ray beam and a optimal beam spoiler when treating a patient, a similer build-up dose with a 6 MV photon beam could be achieved, while maintaining a certain amount of skin spring. But it was provided higher surface dose under SSS of less than 5 cm, the spoiler thickness of more than 1.8 cm or more, and larger field size than $20{\times}20cm^2$ provided higher surface dose like bolus and obliterated the spin-sparing effect. the effects of the beam spoiler on beam profile was reduced with increasing depths. Conclusion: The lucite spoiler allowed using of a 10 MV photon beam for the radiation treatment of head and neck caner by yielding secondary scattered electron on the surface. The dose at superficial depth was increased and the depth of maximum dose was moved to near the skin surface. Spoiling the 10 MV x-ray beam resulted in treatment plans that maintained dose homogeneity without the consequence of increased skin reaction or treat volume underdose for regions near the skin surface. In this, the optimal spoiler thickeness of 1.2 cm and 1.8 cm were found at SSS of 7 cm for $10{\times}10cm^2$ field. The surface doses were measured 60% and 64% respectively. In addition, It showed so optimal that 94% and 94% at the depth of 0.4 cm and dmax respectively.

  • PDF

The Clinical Study of the Lower Respiratory Tract Infection by Respiratory Syncytial Virus on Children under 2 Year of Age (2세 이하 어린이에서 Respiratory Syncytial Virus에 의한 하기도 감염에 관한 연구)

  • Cho, Jung Ik;Choi, Hyung Chul;Kim, Jong Duck;Cho, Ji Hyun
    • Pediatric Infection and Vaccine
    • /
    • v.7 no.2
    • /
    • pp.193-200
    • /
    • 2000
  • Purpose : This study was designed and performed for evaluations of clinical manifestation and course of the children under 2 year of age with respiratory tract infection and positive respiratory syncytial virus(RSV) antigen. Methods : The selection criteria of the patients were children under 24 month-of-age, Clinical manifestation of respiratory tract infection, and positive RSV antigen that was detected by Vitek ImmunoDiagnostic Assay System(VIDAS) from nasal cavity. The additional laboratory and simple chest X-ray findings were reviewed from the chart of children who were admitted Wonkwang university hospital from October 1999 to March 2000. Results : Total number of patients enrolled on this study was 102. The 48(47%) children were RSV antigen positive by VIDAS method. Abnormal chest X-ray findings were noticed in 38 cases. The male to female sex ratio of 48 RSV antigen positive cases was 1.2 : 1. The mean and range of age was $10.2{\pm}5.9$ and 1.0~24 months. The peak outbreak of cases was noticed on November, 1999. All of the cases shows coughing but rale was audible in 30 cases(60%). Dyspnea, wheezing, and intercostal retraction were noticed 11(23%), 15(31%), and 10(21%) cases respectively. The most common chest X-ray finding was scattered patch infiltration that was noticed in 30 cases(63%). The mean total white blood cell counts in peripheral blood was $12,608{\pm}4,686/mm^3$. The mean blood level of IgA and IgE were $50.8{\pm}20.9$ and $72.1{\pm}98.3mg/dL$ respectively. The C-reactive protein was $16.0{\pm}18.5mg/L$. Total 5 cases need a mechanical respiraton. The duration of admission was under 7 days in 36 cases(75%). Conclusion : The RSV antigen was detected commonly in late fall and winter season. The severity of children under 2 years old with RSV respiratory tract infection take in some degree a gave courses.

  • PDF