Evaluation of the Space Scattered Dose According to the Position of the Radiation Workers in Mammography Room  

Lee, Dong-Yeon (Department of Radiation Oncology, Dongnam Inst. of Radiological & Medical Science)
Lee, Jin-Soo (Department of Radiology, Inje University Heaundae Paik Hospital)
Publication Information
Journal of radiological science and technology / v.39, no.3, 2016 , pp. 297-303 More about this Journal
Abstract
This study was conducted to evaluate the dose of the space to the controller located within the mammography room conducted a research on ways to the reduction exposure to the radiation workers. Results, the dose of 6.18 mGy/year was measured when there is no difference in the hilar area of the controller position, the dose of 2.35E-11 mGy/year was measured when installing the Shielding door. In addition, when the direction of the X-ray tube anode be heading this direction controller, low average level measured was 0.30 mGy/year. Based on this study, the mammography should be considered when installing the anode and cathod directions. And, by installing the shielding door, it must be able to completely separate shooting space and control room. This is the best way radiation protection method in radiation workers.
Keywords
Mammograpy; Radiation worker; Heel-effect; Shielding-door;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 BC Centre for Disease Control : Guideline for Determining the X-ray Shielding Requirements for a Mammographic Facility, 2014
2 Inja Lee, Kyeyeon Park, Sungsoo Kim : Research on the Actual Condition of Mammography and Space Scattered Dose in Mammography Room, Korean Society of Radiological Science, Vol. 29, No. 1, 21-28, 2006
3 Seyoung Jang, Wanggyun Oh, Jongbae Park, Gyehwan Jin : The energy spectrum and phantom image quality according to mammography target-filter combinations, Journal of the Korean Society of Radiology, Vol. 7, No. 1, 51-55, 2013   DOI
4 Noriah Jamal, Siti Selina Abdul Hamid, Humairah Samad Cheung et al. : A survey on mean grandular dose from full-field digital mommography system, operate using Mo/Mo and W/Rh target/filter combination, IAEA, INIS, Vol. 45, Issue 43, 2013
5 M.B. Tavakoli, N. Kolghi, Z. Shahi, Z. Shaneh : Evaluation of the relation between breast grandular absorbed dose and radiographic quality in mammography, Iran. J. Radiant. Vol. 6, No. 2, 77-82, 2008
6 Su Jeong Yu, Sang Wook Lim, Sun Young Ma, et al. : Invivo dosimetry for mammography with and without lead apron using the glass dosimeters, Progress in Medical Physics, Vol. 26, No. 2, 93-98, 2015   DOI
7 Los Alamos National Laboratory : User's manual version 2.5.0, LANL, 2005
8 Korea Food and Drug Administration : A study on guidance for test and method of radiation protection, 2012
9 Jin Young Park, Sung Min Baek : A study on the actual conditions and characteristic of mammographic units in some area, Journal of the Korean Society of Radiology, Vol. 6, No. 2, 121-127, 2012   DOI
10 A.A. Mowlavi : X-ray spectra calculation for different target-filter of mammograms using MCNP code, Iran. J. Radiant. Vol. 3, No. 3, 129-133, 2005
11 Seong Kwan Choi : Relationship between the distribution of space doses in the X-ray rooms and the inverse square law of distance, The Korea Contents Association, Vol. 13, No. 8, 301-307, 20