• 제목/요약/키워드: Scattered Radiation Dose

검색결과 133건 처리시간 0.022초

이동용 치과 X선 발생장치의 누설 및 산란 선량에 관한 연구 (Leakage and scattered radiation from hand-held dental x-ray unit)

  • 김은경
    • Imaging Science in Dentistry
    • /
    • 제37권2호
    • /
    • pp.65-68
    • /
    • 2007
  • Purpose: To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. Materials and Methods: For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR III was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of handheld dental X-ray unit were 70 kVp, 3 mA, 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. Results: The mean dose at the hand level when human skull DXTTR III was exposed with portable X-ray unit $6.39{\mu}Gy$, and the mean dose with fixed X-ray unit $3.03{\mu}Gy$ (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was $2.97{\mu}Gy$ and with fixed X-ray unit the mean dose was $0.68{\mu}Gy$ (p<0.01). Conclusions: The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography.

  • PDF

두꺼운 피사체 X선 촬영 시 보호앞치마 착용의 유용성 (Utility of Wearing Protective Apron for X-ray of Thick Subject)

  • 최성관;동경래
    • 방사선산업학회지
    • /
    • 제11권3호
    • /
    • pp.167-171
    • /
    • 2017
  • This study examined the effectiveness degree of a protective apron that is taken not to be exposed to the first ray or scattered rays, for X-ray of thick subject like lateral lumbar, and the results are as follows; First, spatial dose by scattered rays is shielded by 3 mmPb protective apron, 86.8% at a distance of 50 cm, 92.7% at 100 cm, and 95.6% at 200 cm, when minimizing the field size, while 89% at a distance of 50 cm, 92.3% at 100 cm, and 95.2% at 200 cm, when maximizing the field size. Second, 1st exposure dose is shielded by 3 mmPb protective apron, 93.7% at a distance of 50 cm, 94.4% at 100 cm, and 93.6% at 200 cm, when minimizing the field size, while 93.7% at a distance of 50 cm, 93.6% at 100 cm, and 94.2% at 200 cm, when maximizing the field size.

MCNPX 시뮬레이션을 이용한 무납 방사선 차폐 시트 기반의 공간산란 저감화 평가 (Evaluating the Reduction of Spatial Scattering based on Lead-free Radiation Shielding Sheet using MCNPX Simulation)

  • 양승우;박금별;허예지;박지군
    • 한국방사선학회논문지
    • /
    • 제14권4호
    • /
    • pp.367-373
    • /
    • 2020
  • 물체와 X선의 상호작용로 발생하는 산란선으로 야기되는 공간 산란선량은 대부분이 저에너지 영역의 전자기파로 인체에 비교적 쉽게 흡수되어 방사선 피폭정도가 증가하게 된다. 이러한 공간 산란 선량은 방사선작업 종사자 및 환자의 방사선 피폭 정도 지표로도 사용되고 있으며 간접적으로 발생하는 공간 산란 선량을 줄여 피폭을 저감화하기 위한 방안의 필요성이 마련될 필요성이 있다. 이에 본 연구에서는 공간산란 선량을 저감화 방안으로 무납 방사선 차폐 시트를 제시하였고 가슴 X선 촬영검사를 기준으로 몬테카를로(MC; Monte Carlo) 시뮬레이션을 수행하여 거리 변화에 따른 갑상샘과 생식선 위치에서 흡수되는 산란선의 흡수선량을 산출하였고 실측치와 차폐율을 비교 평가하였다.

흉부X선촬영시(胸部X線撮影時) 산란선(散亂線)이 화질(畵質)과 피폭선량(被曝線量)에 미치는 영향(影響) (Effects of the Scattered Radiation on Image Quality and Exposure Dose in Chest Radiography)

  • 반야유;임태랑;석전유치;전전미향;앵정달야;이만구;안봉선;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제16권2호
    • /
    • pp.27-38
    • /
    • 1993
  • To investigate relationships between image guality and exposure dose, Chest X-ray films were evaluated for the following points:how much scattered radiation can affect reduction in image quality and can be permissible diagnostically? For this purpose using a test charts and Burger's phantoms. The visual evaluation of their X-ray films and the measurements of scattered radiation were carried out. The dose of scattered radiation ranging from 20 to 25% was found to be for nothing in any diagnostic obstacle. In this range, surface doses were low of 17, 21, and $25{\mu}Gy$ for The thickness of the chest of 15, 20 and 25 cm respectively. Comparison of these high voltage X-ray films with low voltage ones showed a surface dose rate of 1:11.7. Therefore, X-ray quality, photosensitive materials(film and screen) and grid should be selected very carefully for the purpose of reduction in exposure dose.

  • PDF

이동형 X선 발생장치의 2차 방사선 차폐를 위한 선속조절기 개발 연구 (Development of Radiation Restrictor for Secondary Radiation Shielding of Mobile X-ray Generator)

  • 구본열;김가중
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권5호
    • /
    • pp.397-403
    • /
    • 2018
  • Mobile X-ray generators are used not in the radiation area but in open space, which causes the exposure of secondary radiation to the healthcare professionals, patients, guardians, etc., regardless of their intentions. This study aimed to investigate the shielding effect of the developed radiation restrictor to block the secondary radiation scattered during the use of mobile X-ray generator. Upon setting the condition of mobile X-ray generator with chest AP, spatial doses were measured by the existence of human equivalent phantom and radiation restrictor, and measured by the existences of phantom and radiation restrictor at the same length of 100 cm. Measurements were taken at intervals of 10 cm every $30^{\circ}$ from $-90^{\circ}$ (head direction) to $+90^{\circ}$ (body direction). Upon the study results, spatial doses in all direction were increased by 45% on average when using phantom in the same condition, however, they were decreased by 64% on average when using the developed radiation restrictor. The dose at 100 cm from the center of X-ray was $3.0{\pm}0.08{\mu}Gy$ without phantom and was increased by 40% with $4.2{\pm}0.08{\mu}Gy$ after phantom usage. The dose when using phantom and the developed radiation restrictor was $1.4{\pm}0.08{\mu}Gy$, which was decreased by 66% compared to the case without using them. Therefore, it is considered the scattered radiation can be shielded at 100-150 cm, the regulation of the distance between beds, effectively with the developed radiation restrictor when using mobile X-ray generators, which can lower the radiation exposure to the people nearby including healthcare professionals and patients.

방사선 치료실 벽면 거리에 따른 심부선량과 표층선량 평가 (Evaluation of Depth Dose and Surface Dose According to Treatment Room Wall Distance)

  • 제재용
    • 한국방사선학회논문지
    • /
    • 제5권3호
    • /
    • pp.121-125
    • /
    • 2011
  • 본 연구는 방사선 치료실 벽면 거리에 따른 표층선량과 심부선량에 관하여 알아보고자 한다. 선형가속기에서 발생하는 고에너지 광자선은 치료기 헤드, 콜리메이터, 환자, 치료실내의 모든 벽과 물질들에 의하여 많은 산란선이 발생된다. 산란선의 측정은 열형광선량계(TLD)를 사용하였다. 선형가속기의 회전중심으로부터 벽까지의 거리는 236, 272, 303과 337 cm로 측정되었다. 6 MV 광자선을 100 cGy와 200 cGy를 조사한 결과 벽까지의 거리가 짧은 236 cm에서 표층선량은 0.49, 0.83 mSv이고, 272 cm에서는 0.41, 0.53 mSv, 303 cm에서는 0.28, 0.57 mSv, 337 cm에서는 0.33, 0.76 mSv로 각각 나타났다. 치료실 벽의 거리에 따라 표층선량은 현저한 차이를 나타내었다. 이러한 결과는 방사선 치료환자의 확률적영향과 관련하여 유용한 자료로 활용될 것이다.

수술실 내 C-arm 장치의 산란선 분포에 대한 연구 (The Study on Scattered Ray by C-arm in Operation Room)

  • 박성현;박주미;김현수
    • 대한디지털의료영상학회논문지
    • /
    • 제13권1호
    • /
    • pp.21-26
    • /
    • 2011
  • A radiation imaging system used in a surgery room is mainly using C-arm which is purposed to fluoroscope. C-arm is often use to watch an operation's accuracy and progress, but not only being bombed to this first beam but also affected to this scattered beam, so now we are look for the way to reduce bombed amount of doctor, nurses and radiological technologists. We measured the exposure dose in $0^{\circ}$ spot according to the distance to find out frequency distribution of scattered ray in an operation room and found the spot which has the same exposure dose from $30^{\circ}$ distance of all directions and wrote isodose curve. We analyzed the data and found out the sudden reduction of scattered ray according to the long direction also found out that scattered ray was not related to the directions. Operators must recognize the reduction of exposure dose. Because reducing scattered ray from all directions in an operation room is really difficult. So every operators must use shelters to reduce the exposure dose and notice the safety.

  • PDF

조사야 외부의 산란선량 감소 방법에 관한 연구 (A Study on the Reduction of Scattered Ray in Outside Radiation Field)

  • 제재용;장호원
    • 한국방사선학회논문지
    • /
    • 제10권7호
    • /
    • pp.539-543
    • /
    • 2016
  • 본 연구는 진단용 X선 발생장치에서 조사야 외부의 산란선량을 감소시켜 환자의 피폭 선량을 감소시키기 위한 방법이다. 자체 제작한 $150{\times}190mm^2$ 납판을 콜리메이터 하단에 부착함으로써 조사야 이외의 부위에 도달하는 산란선량을 감소시키고자 하였다. 납판을 추가로 삽입 후 X선 관축방향인 X-축의 산란선량을 측정한 결과 26 ~ 36% 감소하는 것으로 나타났으며, 관축의 수직 방향인 Y-축 방향에서는 납판의 사용 유무에 따른 산란선량은 큰 변화를 나타내지 않았다. 이러한 결과는 콜리메이터 Shutter에 의해서 발생하는 산란선 보다는 초점 근방에서 발생하는 초점외 X선에 의한 산란선 영향이 크다는 것을 의미한다. 따라서 기존의 콜리메이터 하단에 추가로 납판을 설치하는 것이 조사야 외부의 X-축 산란선량을 감소시키는 방법으로 판단되어진다.

몬테카를로 방법을 이용한 슬릿형태 구조물의 차폐능력 평가 (Shielding Capability Evaluation of Slit-shaped Structure for Scattered X-ray using Monte Carlo Method)

  • 김상록;허재승
    • 한국방사선학회논문지
    • /
    • 제14권6호
    • /
    • pp.733-740
    • /
    • 2020
  • 의료종사자의 피폭선량을 줄이기 위한 최근 연구에서, 방사선이 산란될 때 발생하는 광전효과를 이용하여 방사선치료실 입구에서의 선량을 줄이는 방법이 제안되었다. 이 방법은 특히 저에너지 광자에 효과적이기 때문에 본 연구에서는 몬테카를로 시뮬레이션을 이용하여 슬릿형태 구조물의 일반촬영실 산란 엑스선에 대한 차폐성능을 평가하였다. 두께 2 mm, 폭 50 mm, 길이 900 mm인 판을 2 mm 간격으로 수평 적재하는 형태의 슬릿형태 구조물은 알루미늄에 비해 철 또는 납으로 만드는 경우 차폐효과가 뛰어났다. 재질을 철로 한정한 경우 선원과 관심구역 사이에서 결정된 구조물의 설치위치는 차폐효과와 무관했으며, 판의 폭은 차폐효과에 비례했다. 폭 50 mm 철판을 사용한 경우 산란선이 직접 발생하는 바닥 및 환자의 높이를 제외하면 약 99.9% 또는 그 이상의 차폐효과가 있었다.

6 MeV 전자선 치료 시 차폐물질로서 알루미늄, 구리, 납 (Aluminum, Copper and Lead as Shielding Materials in 6 MeV Electron Therapy)

  • 이승훈;차석용;이선영
    • 한국콘텐츠학회논문지
    • /
    • 제14권2호
    • /
    • pp.457-466
    • /
    • 2014
  • 고 에너지 전자선 치료에 있어서 차폐물질은 종양조직 외 정상조직이나 주요장기를 보호하기 위해 사용된다. 하지만 이러한 물질에서 발생되어지는 산란선은 심부선량에 영향을 줄 수 있으며, 물질원자번호에 따라 다르게 나타난다. 이에 차폐물질로써 사용가능한 알루미늄, 구리, 납 등의 다양한 원자번호 물질을 전하 감약율 95% 되는 두께로 하여 측정과 MCNPX 모의계산으로 산란율을 비교분석하였다. 산란선 영향을 많이 받는 표면의 선량변화율은 최대 물질두께에서 +0.88%, 원자번호에서 +0.43%의 영향을 받으며, 전하 감약율 95% 되는 두께의 알루미늄, 구리, 납 물질은 측정에서 +19.70%, +15.20%, +12.40% 계산에서 +25.00%, +15.10%, +13.70%를 보였다. 이로 인해 산란율은 물질두께가 원자번호보다 많은 영향을 주며, 산란전자가 광자보다 많은 기여를 하고 있음을 알 수 있었다. 이에 임상에서의 적절한 차폐물질은 두께영향 산란선이 적게 방출되는 고 원자번호물질이 적당하다고 사료된다.