• 제목/요약/키워드: Scanning width

검색결과 366건 처리시간 0.027초

Powder Blasting 에 의한 유리의 미세 홈 가공시 노즐 주사횟수의 영향 (Effect of Nozzle Scanning in Micro Grooving of Glass by Powder Blasting)

  • 김광현;최종순;박동삼
    • 대한기계학회논문집A
    • /
    • 제26권7호
    • /
    • pp.1280-1287
    • /
    • 2002
  • The old technique of sandblasting which has been used for decoration of glass surface has recently been developed into a powder blasting technique for brittle materials such as glass, silicon and ceramics, capable of producing micro structures larger than $100{\mu}$ m. This paper describes the performance of powder blasting technique in micro-line grooving of glass and the effect of the number of nozzle scanning on the depth and width of line groove. Experimental results showed that increasing the no. of nozzle scanning resulted in the increase of depth and width in grooves. Increase of width which may cause several problems in the precision machining results from wear of mask film. Therefore, well-controlled masking process is the most important factor for micro machining of glass with accuracy.

Powder Blasting을 이용한 유리의 미세 선형 홈 가공시 노즐 주사 횟수의 영향 (Effect of the Number of Nozzle Scanning in Micro-Line Grooving of Glass by Powder Blasting)

  • 박경호;김광현;최종순;박동삼
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 춘계학술대회 논문집(한국공작기계학회)
    • /
    • pp.294-299
    • /
    • 2001
  • The old technique of sandblasting which has been used for decoration of glass surface has recently been developed into a powder blasting technique for various materials, capable of producing micro structures larger than 100 m. This paper describes the performance of powder blasting technique in micro-line grooving of glass and the effect of the number of nozzle scanning on the depth and width of line groove. Experimental results showed that increasing the no. of nozzle scanning resulted in the increase of depth and width in grooves. Increase of width which may cause several problems in the precision machining results from wear of mask film.

  • PDF

Effect of Total Collimation Width on Relative Electron Density, Effective Atomic Number, and Stopping Power Ratio Acquired by Dual-Layer Dual-Energy Computed Tomography

  • Jung, Seongmoon;Kim, Bitbyeol;Yoon, Euntaek;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.165-171
    • /
    • 2021
  • Purpose: This study aimed to evaluate the effect of collimator width on effective atomic number (EAN), relative electron density (RED), and stopping power ratio (SPR) measured by dual-layer dual-energy computed tomography (DL-DECT). Methods: CIRS electron density calibration phantoms with two different arrangements of material plugs were scanned by DL-DECT with two different collimator widths. The first phantom included two dense bone plugs, while the second excluded dense bone plugs. The collimator widths selected were 64 mm×0.625 mm for wider collimators and 16 mm×0.625 mm for narrow collimators. The scanning parameters were 120 kVp, 0.33 second gantry rotation, 3 mm slice thickness, B reconstruction filter, and spectral level 4. An image analysis portal system provided by a computed tomography (CT) manufacturer was used to derive the EAN and RED of the phantoms from the combination of low energy and high energy CT images. The EAN and RED were compared between the images scanned using the two different collimation widths. Results: The CT images with the wider collimation width generated more severe artifacts, particularly with high-density material (i.e., dense bone). RED and EAN for tissues (excluding lung and bones) with the wider collimation width showed significant relative differences compared to the theoretical value (4.5% for RED and 20.6% for EAN), while those with the narrow collimation width were closer to the theoretical value of each material (2.2% for EAN and 2.3% for RED). Scanning with narrow collimation width increased the accuracy of SPR estimation even with high-density bone plugs in the phantom. Conclusions: The effect of CT collimation width on EAN, RED, and SPR measured by DL-DECT was evaluated. In order to improve the accuracy of the measured EAN, RED, and SPR by DL-DECT, CT scanning should be performed using narrow collimation widths.

전극 홈 형상에 따른 스캐닝 미러의 구동 특성 (Driving Characteristics of the Scanning Mirrors to the Different width and Number of the Grooves on the Electrodes)

  • 박근우;김용권
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권11호
    • /
    • pp.575-580
    • /
    • 2001
  • In this paper, using $500\mum-thickness\; (100)\; silicon\; wafer,\; flat\; 65\mum-thickness$ silicon mirror plates were fabricated through dry etching and wet etching, and $45\mum-depth$ grooved driving electrodes were fabricated through UV-LIGA process. Four shapes of the driving electrode were fabricated: twenty four grooves of the $50\mum-width$, twelve grooves of the $100\mum-width$, six grooves of the $200\mum-width$, and no grooves on the driving electrode. Fabricated mirror plate size and spring size are $2400\times2400\times65\mum3\; and \;500\times10\times65\mum3,$ respectively. Mirror plate parts and driving electrodes were assembled into the scanning mirrors. Measured natural resonance frequencies were about 600Hz which have error within $\pm 2%$ to calculated value. Due to the squeeze effect in the narrow gap between the mirror plate and the driving electrode, measured resonance frequencies were reduced as raising the amplitude of the mirror plate. In a case of driving electrode without grooves, the resonance frequency was reduced largely, compared with a case of driving electrode with grooves. According to the experimental results, squeeze effect was smaller in the driving electrode with smaller-width and many grooves. Therefore, the driving electrode with smaller-width and many grooves was effective in low voltage and high speed operation.

  • PDF

중국 성인여성의 직접계측과 3D Body scanning 치수 비교 연구 (Comparison of Size between direct-measurement and 3D body scanning)

  • 차수정
    • 패션비즈니스
    • /
    • 제16권1호
    • /
    • pp.150-159
    • /
    • 2012
  • This study intend to analyze differences between 3D body scanning sizes and direct measurement sizes of same subjects. The subjects of study are female students of university in China. 3D data analyze as a 3D Body Measurement Soft System. The conclusion found is as below: In case of circumferences, error between direct-measurement size and 3D body scanning size is from 4.9mm to 62.2mm. The neck circumference size of directmeasurement is bigger than 3D body scanning size. The height error range is from 0.6mm to 51mm. Height of underbust, waist and hip are that direct-measurement sizes are higher than 3D body scanning sizes. Gap of width is from 3.8mm to 21.9mm. The gap range is too narrow relatively to others. Only direct-measurement size of neck width is wider than 3D body scanning size. Error range of length is from 0.3mm to 41.8mm. 3D body scanning sizes of lateral neck to waistline, upperarm length, arm length, neck shoulder point to breast point, shoulder center point to breast point, lateral shoulder to breast point are longer than direct-measurement sizes. They have a negative margin of error. I intend to set up same measurement point between direct-measurement and 3D body scanning but they have some errors because direct-measurement point is applied by a person. 3D body scanning measurement point is settled by automatic system. A measurement point of direct-measurement and 3D body scanning isn't unite. So we need to make a standard of setting up measurement points.

3D 바디 스캐닝을 활용한 20~30대 남성의 자켓 맞음새 만족도 (Research on jacket-fit satisfaction among men in their 20s and 30s using 3D body scanning)

  • 이소정;손재민;김동은
    • 복식문화연구
    • /
    • 제26권1호
    • /
    • pp.30-44
    • /
    • 2018
  • The study purpose was to investigate the jacket-fit satisfaction level of men in their 20s and 30s, using body-scanning data and a questionnaire. Thirty-five men were scanned using a 3D body scanner. The participants were divided into three groups (Small, Medium, and Large) based on their chest-circumference measurement. Their levels of satisfaction with the fit of their tailored jacket were compared by group. Chest, waist, and hip circumferences increased substantially as group size increased. The M-group was mostly satisfied with all body-site views. The S-group was especially dissatisfied with height, back width, waist circumference, and upper-arm circumference. The L-group was especially dissatisfied with waist circumference and hip circumference. The majority of the participants preferred the jacket closely fitted to their body. More than half of the participants thought finding a jacket of suitable size was difficult. When purchasing ready-to-wear jackets, the S-group and the M-group considered shoulder width important, while the L-group considered chest circumference the most important area. When evaluating the fit of ready-to-wear jackets, the L-group evaluated chest circumference, back width, and waist circumference as poor fits. The M-group evaluated sleeve length and shoulder width as poor fits, and the S-group agreed with respect to sleeve length. Body-satisfaction levels and matching jacket-satisfaction levels differed by body-size group, as did areas that need improvement. The conclusion is that size-group analysis using 3D body scanning can be utilized effectively for jacket-fit analysis. The findings of the current study can be applied to improving jacket fit among young male consumers.

레이저 유도 열화학 습식에칭을 이용한 티타늄 미세구조물 제조 (Laser-induced Thermochemical Wet Etching of Titanium for Fabrication of Microstructures)

  • 신용산;손승우;정성호
    • 한국정밀공학회지
    • /
    • 제21권4호
    • /
    • pp.32-38
    • /
    • 2004
  • Laser-induced thermochemical wet etching of titanium in phosphoric acid has been investigated to examine the feasibility of this method fur fabrication of microstructures. Cutting, drilling, and milling of titanium foil were carried out while examining the influence of process parameters on etch width, etch depth, and edge straightness. Laser power, scanning speed of workpiece, and etchant concentration were chosen as major process parameters influencing on temperature distribution and reaction rate. Etch width increased almost linearly with laser power showing little dependence on scanning speed while etch depth showed wide variation with both laser power and scanning speed. A well-defined etch profile with good surface quality was obtained at high concentration condition. Fabrication of a hole, micro cantilever beam, and rectangular slot with dimension of tess than 100${\mu}{\textrm}{m}$ has been demonstrated.

Powder Blasting을 이용한 미세 포켓가공 (Micromachining of Pocket by Powder Blasting)

  • 박경호;최종순;김광현;박동삼
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.1060-1063
    • /
    • 2001
  • The mechanical etching technique has recently been developed to a powder blasting technique for various materials, capable of producing micro structures larger than 100$\mu$m. This paper describes the performance of powder blasting technique in micro-pocketing of stainless steel and the effect of the number of nozzle scanning and the nozzle height on the depth and width of pockets. Experimental results showed that increasing the no. of nozzle scanning and decreasing the nozzle height resulted in the increase of depth and width in pockets. Increase of width results from wear of mask film.

  • PDF

FE-tip을 이용한 Nano-Lithography 기술에 관한 연구 (A Study on the Nano-Lithography using FE-tip)

  • 최재혁;박선우;김철주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1160-1163
    • /
    • 1999
  • In this study, we developed FE-tip lithography system that could apply to multi-tip system and did lithography using FE-tip. The software that control FE-tip lithography system, was proposed for acquiring more adaptive data to compensate the effect of fluctuation. We found that the fluctuation effect was reduced. The minimum line width was related to applied voltage and we observed a movement of Z-axis piezo stage to correct the error of this system. When FE current was 5nA, scanning speed was $3{\mu}m/sec$ and applied voltage was 200V, we made a line pattern which had minimum line width of 614 nm. If we reduce applied voltage to several decades and increase scanning speed to $20{\mu}m/sec$, it is possible to set the minimum line width of 100 nm. The proposed system can be easily applied to multi FE-tip lithography system.

  • PDF

Powder Blasting에 의한 미세 포켓의 기계적 에칭 (Mechanical Etching of Micro Pocket by Powder Blasting)

  • 박경호;오영탁;박동삼
    • 한국정밀공학회지
    • /
    • 제19권1호
    • /
    • pp.219-226
    • /
    • 2002
  • The mechanical etching technique has recently been developed to a powder blasting technique for various materials, capable of producing micro structures larger than 100$\mu$ m. This paper describes the performance of powder blasting technique in micro-pocketing of stainless steel and the effect of the number of nozzle scanning and the nozzle height on the depth and width of pockets. Experimental results showed that increasing the no. of nozzle scanning and decreasing the nozzle height resulted in the increase of depth and width in pockets. Increase of width results from wear of mask film.