• Title/Summary/Keyword: Scanning treatment

Search Result 1,682, Processing Time 0.029 seconds

Use of an Optical Scanning Device to Monitor the Progress of Noninvasive Treatments for Chest Wall Deformity: A Pilot Study

  • Kelly, Robert E. Jr.;Obermeyer, Robert J.;Kuhn, M. Ann;Frantz, Frazier W.;Obeid, Mohammad F.;Kidane, Nahom;McKenzie, Frederic D.
    • Journal of Chest Surgery
    • /
    • v.51 no.6
    • /
    • pp.390-394
    • /
    • 2018
  • Background: The nonsurgical treatment of chest wall deformity by a vacuum bell or external brace is gradual, with correction taking place over months. Monitoring the progress of nonsurgical treatment of chest wall deformity has relied on the ancient methods of measuring the depth of the excavatum and the protrusion of the carinatum. Patients, who are often adolescent, may become discouraged and abandon treatment. Methods: Optical scanning was utilized before and after the intervention to assess the effectiveness of treatment. The device measured the change in chest shape at each visit. In this pilot study, patients were included if they were willing to undergo scanning before and after treatment. Both surgical and nonsurgical treatment results were assessed. Results: Scanning was successful in 7 patients. Optical scanning allowed a visually clear, precise assessment of treatment, whether by operation, vacuum bell (for pectus excavatum), or external compression brace (for pectus carinatum). Millimeter-scale differences were identified and presented graphically to patients and families. Conclusion: Optical scanning with the digital subtraction of images obtained months apart allows a comparison of chest shape before and after treatment. For nonsurgical, gradual methods, this allows the patient to more easily appreciate progress. We speculate that this will increase adherence to these methods in adolescent patients.

Nondestructive Evaluation for Long-term Heat Treatment Effects on Microstructure of Co-base Superalloy by Scanning Acoustic Microscope (주사음향현미경을 이용한 코발트기 초내열합금 미세조직에 관한 장시간 열영향에 대한 비파괴평가)

  • lEE, JoonHee;Kim, ChungSeok
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.32 no.3
    • /
    • pp.118-123
    • /
    • 2019
  • The aim of this study investigates the feasibility of scanning acoustic microscope (SAM) with high frequency transducer for material degradation. The test specimen was prepared by artificial heat treatment of Co-base superalloy. The high frequency 200 MHz acoustic lens was used to generate the leaky surface acoustic wave (LSAW) on the test specimens. The matrix precipitates coarsened with thermal aging time, and then grow up to several tens of micrometers. The velocity of LSAW decreased with increasing aging time. Also, it has a good correlation between LSAW and hardness. Consequently, V(z) curve methods of SAM using high frequency transducer is useful tool to evaluate the heat treatment effects on microstructure.

Analysis of Treatment and Delay Times by Disease Site and Delivery Technique at Samsung Medical Center - Proton Therapy Center

  • Jo, Kwanghyun;Ahn, Sung Hwan;Chung, Kwangzoo;Cho, Sungkoo;Shin, Eunhyuk;Hong, Chae-Seon;Park, Seyjoon;Kim, Dae-Hyun;Lee, Boram;Lee, Woo-Jin;Seo, Se-Kwang;Jang, Jun-Young;Choi, Doo Ho;Lim, Do Hoon;Han, Youngyih
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.258-266
    • /
    • 2016
  • We have treated various disease sites using wobbling and scanning proton therapy techniques since December 2015 at the Samsung Medical Center. In this study, we analyze the treatment time for each disease site in 65 wobbling and 50 scanning patient treatments. Treatment times are longest for liver and lung patients using the respiratory gating technique in the wobbling treatment and for cranio-spinal irradiation in pediatric patients with anesthesia in the scanning treatment. Moreover, we analyze the number of incidents causing treatment delays and the corresponding treatment delay time. The X-ray panel was the main reason for delays in the wobbling treatment; this decreased continually from January to June 2016, related closely to the proficiency of the human operators involved. The main reason for delays in the scanning treatment was interlocks during scanning pattern delivery; this was resolved by proton machine engineers. Through this work, we hope to provide other institutes with useful insight for initial operation of their proton therapy machines.

QUANTITATIVE ANALYSIS OF MINERAL CHANCE IN THE INITIAL CAR10US LESION USING CONFORMAL LASER SCANNING MICROSCOPY (공초점 레이저 주사 현미경을 이용한 법랑질 초기 우식 재광화의 정량적 분석)

  • 차승우;윤태철;박성호;이찬영;금기연
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • Dental Caries which has high prevalence rate, accounts for majority of dental diseases. Many treatment and preventive treatment has been developed, thereby reducing the prevalence rate, but in our country, fluoridization has not spread widely yet, so prevention has not been done satisfactorily. When dental caries progresses, irreversible damage of tooth structure occurs. In initial dental caries, demineralizing tooth structure can be remineralized, so restorative treatment is unnecessary. In this study, 20 teeth restored with composite resin without fluoride release were used and divided into two groups. Incipient dental caries were artificially made and demineralization procedure was done for 1 and 2 weeks, for each group. Changes in mineral contents around the margins were analysed with confocal laser scanning microscope. The results were as follow. 1. Both total fluorescence of the lesion and average fluorescence of the lesion of remineralized samples decreased compared to demineralizing state. (p<0.01) 2. Confocal laser scanning microscopy can be used in quantitative analysis of mineral change. In result, confocal laser scanning microscopy can be used in quantitative analysis of mineral change and it could be used in many different fields of dentistry in the future.

  • PDF

A Pilot Study of the Scanning Beam Quality Assurance Using Machine Log Files in Proton Beam Therapy

  • Chung, Kwangzoo
    • Progress in Medical Physics
    • /
    • v.28 no.3
    • /
    • pp.129-133
    • /
    • 2017
  • The machine log files recorded by a scanning control unit in proton beam therapy system have been studied to be used as a quality assurance method of scanning beam deliveries. The accuracy of the data in the log files have been evaluated with a standard calibration beam scan pattern. The proton beam scan pattern has been delivered on a gafchromic film located at the isocenter plane of the proton beam treatment nozzle and found to agree within ${\pm}1.0mm$. The machine data accumulated for the scanning beam proton therapy of five different cases have been analyzed using a statistical method to estimate any systematic error in the data. The high-precision scanning beam log files in line scanning proton therapy system have been validated to be used for off-line scanning beam monitoring and thus as a patient-specific quality assurance method. The use of the machine log files for patient-specific quality assurance would simplify the quality assurance procedure with accurate scanning beam data.

Commissioning and Validation of a Dedicated Scanning Nozzle at Samsung Proton Therapy Center

  • Chung, Kwangzoo;Han, Younyih;Ahn, Sung Hwan;Kim, Jin Sung;Nonaka, Hideki
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.267-271
    • /
    • 2016
  • In this study, we present the commissioning and validation results of a dedicated scanning nozzle. The dedicated scanning nozzle is installed in one of the two gantry treatment rooms at Samsung Proton Therapy Center. Following a successful completion of the acceptance test, the commissioning process including the beam data measurement for treatment planning system has been conducted. Extended measurements have been conducted as a validation of the clinical performance of the nozzle and various quality assurance protocols have been prepared.

Effect of Seed Treatment and Observation of Seeds Infested with Fusarium moniforme by Scanning Electron Microscope (Fusarium moniliforme 감염벼종자의 소독과 주사전자현미경적 조직관찰)

  • Sung Jae Mo;Lee Soon Hyung;Yu Seung Hun;Shin Gwan Chull
    • Korean Journal Plant Pathology
    • /
    • v.1 no.1
    • /
    • pp.51-55
    • /
    • 1985
  • This study was carried out to observe the propagule of Fusarium moniliforme on the surface of rice seed and in the vascular bundle of rice stem by scanning electron microscope. Spore and mycelium of F. moniliforme were observed on the surface of rice seed and in the vascular bundle of rice stem. After seed treatment with Benlate T and Busan 3D, F. moniliforme was not isolated from chaffs, but frequently from brown rice, irrespective of disinfection period.

  • PDF

Scanning Electron Microscopy Studies of Saccharomyces cerevisiae Structural Changes by High Hydrostatic Pressure Treatment

  • Bang, Woo-Suk;Swanson, Barry G.
    • Food Science and Biotechnology
    • /
    • v.17 no.5
    • /
    • pp.1102-1105
    • /
    • 2008
  • The structural change and leakage of cellular substances of Saccharomyces cerevisiae attributed by high hydrostatic pressure (HHP) treatment were observed with scanning electron microscopy (SEM). S. cerevisiae (ATCC16664) was inoculated in apple juice for 10 min at $23^{\circ}C$ and the apple juice treated at 138, 207, 276, 345, and 414 MPa pressure for 30 sec at $23^{\circ}C$. Increased of roughness, elongation, wrinkling, and pores on yeast cell surfaces, the yeast cell walls were severely damaged by HHP treatment from 276 to 414 MPa. Inactivation of S. cerevisiae by HHP is dependent on structural changes on the cell walls observed with SEM.

Usefulness of 3-Dimensional Body Surface Scanning in the Evaluation of Patients with Pectus Carinatum

  • Song, Seung Hwan;Kim, Chong Hoon;Moon, Duk Hwan;Lee, Sungsoo
    • Journal of Chest Surgery
    • /
    • v.53 no.5
    • /
    • pp.301-305
    • /
    • 2020
  • Background: Radiographic modalities have been commonly used to evaluate pectus carinatum (PC), and compressive orthotic bracing is the most widely accepted treatment method. The aim of this study was to determine the efficacy of 3-dimensional (3D) body surface scanning as an alternative modality for the evaluation of PC. Methods: The medical records of 63 patients with PC who were treated with compressive orthotic bracing therapy between July 2017 and February 2019 were retrospectively analyzed. Using both 2-view chest radiography (posteroanterior and lateral view) and 3D body scanning, the height of maximal protrusion of the chest wall was measured both before and after 2 weeks of bracing therapy. The difference between the pre- and post-treatment measurements was calculated for both modalities, and these differences were compared and analyzed. Results: Based on the comparison between the pre- and post-treatment radiographs, bracing therapy produced favorable outcomes in all patients (p<0.001). The measurements obtained via 3D scanning were strongly correlated with those obtained via chest radiography (r=0.60). Conclusion: Based on the findings of this study, 3D body surface scanning appears to be an effective, radiation-free, and simple method for the post-treatment follow-up evaluation of PC, and thus can be considered an alternative to radiography.

Study of Carbon Nanotubes Properties by Post-treatment Conditions (후처리 조건에 따른 탄소나노튜브 특성의 변화)

  • Choi Sung-Hun;Lee Jae-Hyeong;Yang Jong-Seok;Park Dae-Hee;Heo Jeong-Ku
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.10
    • /
    • pp.930-934
    • /
    • 2006
  • This paper reports a change of carbon nanotubes(CNTs) properties by post-treatment process after growth of CNTs. CNTs were treated by thermal method and solution method, and then investigated in detail using field emission scanning electron microscopy(FE-SEM), high resolution transmission scanning electron microscopy(HR-TEM), RAMAN spectroscopy, and Fourier Transform Infrared Spectrometer (FT-IR). FT-IR spectra showed that the amount of hydroxyl generated on surface of CNTs were changed with post-treatment condition. FE-SEM and TEM images were shown CNTs diameter and density variations were dependent with their treatment conditions. RAMAN spectroscopy was shown that carbon nanotubes structure vary with treatment conditions.