• 제목/요약/키워드: Scanning system

검색결과 2,482건 처리시간 0.029초

치과용 스캐닝 시스템의 개발과 가변형 상악용 트레이의 재현성 (Development of Dental Scanning System and Reproduction of Adjustable Upper Dental Impression Tray)

  • 차영엽;엄상호
    • 제어로봇시스템학회논문지
    • /
    • 제16권3호
    • /
    • pp.300-304
    • /
    • 2010
  • This study was performed to development a dental three-dimensional laser scanning system and measure the accuracy of new adjustable upper dental impression tray. The metal stock, individual, and new adjustable stock trays were used for 30 stone casts(10 casts each) duplicated a resin master model of maxilla. The dental stone was poured in a vinyl polysiloxane impressions and allowed to set for on hour. The master model and the duplicated casts were digitized using an dental scanning system. The distance between the reference points were measured and analyzed on the graphic image of 3D graphic software of CATIA. The statistical significance of the differences between the groups was determined by a two-way ANOVA. There were no significant differences between the accuracies of the adjustable stock tray and the master model except only anterior arch width on the upper arch. The adjustable upper stock tray showed clinically acceptable accuracies of the study cast produced by them.

A Study on the 3D Scanning of Fashionable Textile Materials - Ripple-finished Cotton Fabric and Shrink-proof Finished/Felted Wool Fabric -

  • Kim, Jong-Jun
    • 패션비즈니스
    • /
    • 제15권6호
    • /
    • pp.101-112
    • /
    • 2011
  • Three-dimensional(3D) virtual clothing simulation system may require the use of physical, mechanical, and configurational data in order to mimic the actual clothing with high degree of realism. Therefore the 3-dimensional scanning system based on optical methods was adopted to extract the 3-dimensional data of the fabric surface. In this study, the appearances of the 3-dimensionally transformed textile fabrics via several finishing procedures were investigated using a 3D scanning system. The wool gauze fabrics treated with the shrink-proof finishing and the felting process showed height changes up to 4.5mm. The 3-dimensional configuration may be objectively described by the use of mesh generation from the scanned output. The generated mesh information may further be utilized in the 3D virtual clothing simulation system for accurate description of the fashionable textile materials used in the simulation system.

VCM을 이용한 나노 정밀도 스캐닝 용 초정밀 이중 스테이지 (Ultra high precision Dual stage system Using Air bearing and VCM for Nano level Scanning)

  • 김기현;권대갑;최영만;김동민;남병욱;이석원;이문구
    • 한국정밀공학회지
    • /
    • 제22권5호
    • /
    • pp.103-112
    • /
    • 2005
  • This paper presents one-axis high precision scanning system and illustrates the design of modified $X-Y-{\theta}$ stage as a tracker using VCM and commercialized air bearings for it. The scanning system for 100nm resolution is composed of the 3-axis stage and one axis long stroke linear motor stage as a follower. In this study a previous proposed and presented structure of VCM for the fine stage is modified. The tracker has 3 DOF($X-Y-{\theta}$ motions by four VCM actuators which are located on the same plane. So 4 actuating forces are suggested and designed to create least pitch and roll motions. This article will show about the design especially about optimal design. The design focus of this fine stage is to have high acceleration to accomplish high throughput. The optimal design of maximizing acceleration is performed in restrained size. The most sensitive constraint of this optimal design is heat dissipation of coil. There are 5 design variables. Because the relationship between design variables and system parameters are quite complicated, it is very difficult to set design variables manually. Due to it, computer based optimal design procedure using MATLAB is used. Then, this paper also describes the procedures of selecting design variables for the optimal design and a mathematical formulation of the optimization problem. Based on the solution of the optimization problem, the final design of the stage is also presented. The results can be verified by MAXWELL. The designed stage has the acceleration of about 5 $m/s^{2}$ with 40kg total mass including wafer chuck and interferometer mirror. And the temperature of coil is increased $50^{\circ}C$. In addition, the tracker is controlled by high precision controller system with HP interferometer for it and linear scaler for the follower. At that time, the scanning system has high precision resolution about 5nm and scanning resolution about 40nm in 25mm/s constant speed

Three-Dimensional Television using Optical Scanning Holography

  • Poon, Ting-Chung
    • Journal of Information Display
    • /
    • 제3권3호
    • /
    • pp.12-16
    • /
    • 2002
  • We first review a real-time three-dimensional (3-D) holographic recording technique called optical scanning holography (OSH) and discuss holographic reconstruction using spatial light modulators (SLMs). We then present how the overall system can be used for 3-D holographic television (TV) display with a wide-angle view of a 3-D image, and address some of the issues encountered. Finally, we suggest some techniques to alleviate the issues encountered in such a 3-D holographic TV system.

Monte Carlo 방법을 이용한 공초점 주사 현미경의 오차 분석과 정렬 공차 할당에 관한 연구 (Error Analysis and Alignment Tolerancing for Confocal Scanning Microscope using Monte Carlo Method)

  • 유홍기;강동균;이승우;권대갑
    • 한국정밀공학회지
    • /
    • 제21권2호
    • /
    • pp.92-99
    • /
    • 2004
  • The errors can cause the serious loss of the performance of a precision machine system. In this paper, we proposed the method of allocating the alignment tolerances of the parts and applied this method to get the optimal tolerances of a Confocal Scanning Microscope. In general, tight tolerances are required to maintain the performance of a system, but a high cost of manufacturing and assembling is required to preserve the tight tolerances. The purpose of allocating the optimal tolerances is minimizing the cost while keeping the high performance of the system. In the optimal problem, we maximized the tolerances while maintaining the performance requirements. The Monte Carlo Method, a statistical simulation method, is used in tolerance analysis. Alignment tolerances of optical components of the confocal scanning microscope are optimized to minimize the cost and to maintain the observation performance of the microscope. We can also apply this method to the other precision machine system.

리얼 타임 리눅스 시스템 설계 (Real Time Linux System Design)

  • 이아리;홍선학
    • 디지털산업정보학회논문지
    • /
    • 제10권2호
    • /
    • pp.13-20
    • /
    • 2014
  • In this paper, we implemented the object scanning with nxtOSEK which is an open source platform. nxtOSEK consists of device driver of leJOS NXJ C/Assembly source code, TOPPERS/ATK(Automotive real time Kernel) and TOPPERS/JSP Real-Time Operating System source code that includes ARM7 specific porting part, and glue code make them work together. nxtOSEK can provide ANSI C by using GCC tool chain and C API and apply for real-time multi tasking features. We experimented the 3D scanning with ultra sonic and laser sensor which are made directly by laser module diode and experimented the measurement of scanning the object by knowing x, y, and z coordinates for every points that it scans. In this paper, the laser module is the dimension of $6{\times}10[mm]$ requiring 5volts/5[mW], and used the laser light of wavelength in the 650[nm] range. For detecting the object, we used the beacon detection algorithm and as the laser light swept the objects, the photodiode monitored the ambient light at interval of 10[ms] which is called a real time. We communicated the 3D scanning platform via bluetooth protocol with host platform and the results are displayed via DPlot graphic tool. And therefore we enhanced the functionality of the 3D scanner for identifying the image scanning with laser sensor modules compared to ultra sonic sensor.

라인레이저를 이용한 3D 모델 추출 방법 (3D Extraction Method Using a Low Cost Line Laser)

  • 윤춘호;김태기;조용욱;남기원;임충혁
    • 한국생산제조학회지
    • /
    • 제26권1호
    • /
    • pp.108-113
    • /
    • 2017
  • In this paper, we proposed a three-dimensional(3D) scanning system based on laser vision technique for 3D model reconstruction. The proposed scanning system consists of line laser, camera, and turntable. We implemented the 3D scanning system using low quality elements. Although these are low quality elements, we reduced the 3D data reconstruction errors greatly using two methods. First, we developed a maximum brightness detection algorithm. This algorithm extracts the maximum brightness of the line laser to obtain the shape of the object. Second, we designed a new laser control device. This device helps to adjust the relative position of the turntable and line laser. These two methods greatly reduce the measuring noise. As a result, point cloud data can be obtained without complicated calculations.

원샷 파노라믹 스캐닝 기반 실시간 다수 얼굴 인식 시스템 (Real-time multiple face recognition system based on one-shot panoramic scanning)

  • 김대환
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 추계학술대회
    • /
    • pp.553-555
    • /
    • 2022
  • 본 논문은 원샷 파노라믹 스캐닝을 기반으로 하는 실시간 자동 얼굴 인식 시스템에 대한 것이다. 한 번의 파노라믹 스캐닝 프로세스를 통하여 실시간으로 다수의 얼굴을 검출하고 사전에 등록된 얼굴을 인식하는 것이다. 한 장의 파노라마 영상 내에서 다수 얼굴 인식을 하는 것이 아닌, 스캐닝 과정에서 얻어진 다수의 영상을 이용하여 얼굴을 인식하도록 한다. 이는 파노라마 영상 생성 시간과 스티칭(Stitching) 오류를 줄임과 동시에 다수 영상의 누적 정보를 활용하여 얼굴 인식 성능을 향상할 수 있다. 이는 간단한 영상 획득 장치만으로 다수 인원의 스마트 출결 시스템과 같은 다양한 응용 프로그램에 사용될 수 있을 것으로 예상한다.

  • PDF

배관 검사용 Radiometric Scanning System 제작 및 시험 (Development of Radiometric Scanning System for the Evaluation of the Pipeline)

  • 김용균;홍석붕;정종은;이윤호;정용하;이정기
    • 비파괴검사학회지
    • /
    • 제22권5호
    • /
    • pp.474-482
    • /
    • 2002
  • 필름을 사용하지 않는 방사선투과검사 시스템인 1차원 Radiometric scanning system을 개발하여 부식 및 침적물이 있는 배관의 두께평가에 적용해 보았다. 개발된 시스템은 단일 방사성 동위원소에서 나오는 방사선을 선형으로 접속하여 시험체를 투과시킨 방사선을 한개의 섬광형 검출기언 BGO를 사용하여 검출하는 single source-single detector alignment system을 제어하는 기계주사 시스템과 제어 프로그램을 개발하였다. 개발된 시스템의 성능을 GEMANT4 프로그램을 사용하여 예측하여 보았다. 그리고, 인공결함을 제작하여 넣은 시편과 두께 변화를 준 시편에 적용하여 실제 성능을 평가하였다. 이 시스템은 방사성 동위원소를 이용하여 배관의 부식과 침적물에 의한 두께 변화에 대하여 실시간으로 필름을 사용하지 않고 평가할 수 있는 가능성을 알 수 있었다.

포트 스캐닝 기법 기반의 공격을 탐지하기 위한 실시간 스캔 탐지 시스템 구현 (A Real Time Scan Detection System against Attacks based on Port Scanning Techniques)

  • 송중석;권용진
    • 한국정보과학회논문지:정보통신
    • /
    • 제31권2호
    • /
    • pp.171-178
    • /
    • 2004
  • 포트 스캐닝 탐지 시스템은 “False Positive”(실제 공격이 아닌데 공격이라고 탐지, 오탐지)와 “False Negative”(실제 공격인데 공격이 아니라고 탐지, 미탐지)가 낮아야 하는 등의 시스템 성능에 관한 요구사항과, 해당 탐지 시스템을 활용한 보안관리가 용이해야 하는 등의 사용자 친화적인 요구사항을 만족할 필요가 있다. 그러나 공개되어 있는 실시간 스캔 탐지 시스템은 False Positive가 높고 다양한 스캔 기법에 대한 탐지가 잘 이루어지지 않고 있다. 또한 실시간 스캔 탐지 시스템의 대부분이 명령어 기반으로 이루어져 있기 때문에 이률 활용하여 시스템 보안 관리를 수행하는데 많은 어려움이 있다. 따라서 본 논문에서는 새로운 필터 룰 집합의 적용에 의해 포트 스캐닝 기법 기반의 다양한 공격을 탐지 할 수 있고, 공격자의 행동 패턴으로부터 유도된 ABP-Rule의 적용에 의해 False Positive를 최소화할 수 있는 실시간 스캔 탐지 시스템(TkRTSD)을 제안한다. 또한 Tcl/Tk를 이용하여 GUI환경을 구축함으로써 사용자가 쉽게 보안관리를 할 수 있는 사용자 친화적인 탐지 시스템을 제안한다.