• 제목/요약/키워드: Scanning speed

검색결과 675건 처리시간 0.043초

The Structural Characterization of Pristine and Ground Graphenes with Different Grinding Speed in Planetary Ball Mill

  • Lee, Tae-Jin;Munkhshur, Myekhlai;Tanshen, Md. Riyad;Lee, Dae-Chul;Chung, Han-Shik;Jeong, Hyo-Min
    • 동력기계공학회지
    • /
    • 제17권5호
    • /
    • pp.23-29
    • /
    • 2013
  • The activation process is the key to graphene's practical application. In this study, the effect of grinding speed in planetary ball mill on structural integrity of graphene has been studied at various grinding speed such as 100 rpm, 200 rpm, 300 rpm, 400 rpm and 500 rpm. The morphology and structure of pristine graphene and ground graphenes were studied using scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray diffraction (XRD) and Raman spectroscopy respectively. According to these results, structural properties of graphene were improved when grinding speed was increased.

리니어모터를 이용한 고속 저중심 스테이지의 개발과 정밀도 향상 (Development for Scanning Type Stage Driven by Linear Motors)

  • 송창규;김정식;김경호;박천홍
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 춘계학술대회 논문집
    • /
    • pp.445-448
    • /
    • 2004
  • Linear motor is very rapidly substituted for rotary motor and ball screw for precision positioning applications because of its characteristics such as high speed, no backlash and simplicities. A precision positioning system which is composed of linear motion(LM) guide and linear motor is widely used since it has easy controllable property but this system has low accuracy problem caused by friction of the LM guide. In this study, a scanning type XY stage is manufactured and some experiments is performed to improve the accuracy of the stage.

  • PDF

In Situ Fluorescence Optical Detection Using a Digital Micromirror Device (DMD) for 3D Cell-based Assays

  • Choi, Jong-Ryul;Kim, Kyujung;Kim, Donghyun
    • Journal of the Optical Society of Korea
    • /
    • 제16권1호
    • /
    • pp.42-46
    • /
    • 2012
  • We have developed a fluorescence optical detection system using a digital micromirror device (DMD) for monitoring 3D cell culture matrices in situ. Full 3D imaging with fast scanning speed was implemented by the combined action of a DMD and a motorized stage. Imaging results with fluorescent microbeads measure the minimum axial resolution of the system as $6.3{\mu}m$, while full 1-mm scanning through 3D alginate-based matrix was demonstrated. For cell imaging, improved images were obtained by removing background fluorescence although the scanning distance was reduced because of low intracellular fluorescence efficiency. The system is expected to be useful to study various dynamics and behaviors of 3-dimensionally cultured cells in microfluidic systems.

금속재료를 이용한 직접식 3차원 형상제조공정의 실험적 연구 (Experimental Study of Direct Metal Prototyping Prcess)

  • 신민철;손현기;양동열
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1994년도 추계학술대회 논문집
    • /
    • pp.169-175
    • /
    • 1994
  • This study attempts to develop a process which can produce three-dimensional shapes of metals directly from CAD data. Prototypes made from metals, can not only be used to test the mecchanical properties of the product, but also potentially become the actual die or product itself. The test-device of the process has been designed and manufactured. The laser scanning method using a scanning path schedule composed of circle and arc elements, scanning speed variation method and dwell method have been developed, which resist warping phenomenon and increase the adhesiveness between the layers. For the production of prototypes with pure iron powder, the optimal values of the principal process parameters have been determined, through which cross-shaped and twisted clover-shaped prototypes have been fabricated. In order to improve the strength of the prototype, the experimental studies of solid-phase sintering, and copper infiltration have been done.

  • PDF

Finishing 용 전자빔 집속 장치의 성능 실험 (Performance Experiment of Electron Beam Convergence Instrument)

  • 임선종
    • 한국레이저가공학회지
    • /
    • 제18권3호
    • /
    • pp.6-8
    • /
    • 2015
  • Finishing process includes deburring, polishing and edge radiusing. It improves the surface profile of specimen and eliminates the alien substance on surface. Deburring is the elimination process for debris of edges. Polishing lubricates surfaces by rubbing or chemical treatment. There are two types for electron finishing. The one is using pulse beam. The other is using the convergent and scanning electron beam. Pulse type device appropriates the large area process. But it does not control the beam dosage. Scanning type device has advantages for dosage control and edge deburring. We design the convergence and scan type. It has magnetic lenses for convergence and scan device for scanning beam. Magnetic lenses consist of convergent and objective lens. The lenses are designed by the specification(beam size and working distance). In this paper, we evaluate the convergence performance by pattern process. Also, we analysis the results and important factors for process. The important factors for process are beam size, pressure, stage speed and vacuum. These results will be utilized into systematizing pattern shape and the factors.

스텝모터를 활용한 정밀 스케닝 구현에 관한 고찰 (Implementation of the laser scanning using the step motor)

  • 전삼석;박찬원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.967-968
    • /
    • 2007
  • This report is the study for laser scanning. Scanning control of $CO_2$ laser, He-Ne laser, used for the treatment of body skin, has relatively low band about hundered Hz. It could be used as a substitiute for expensive galvanometer that is the established scan method, which operates the number of KHz movement by using step motor when it operates low speed. To increase the accuracy of step motor's the angle of rotation, We could materialize 100Hz low band by using open loop, closed loop method with microprocessor. This causes it to be stable even direction by attaching electric capacity sensor. Therefore, We could expect to reduce the cost by manufacturing low band scanner rather than costly feedback galvanometer.

  • PDF

Automatic Building Extraction Using LIDAR Data

  • Cho, Woo-Sug;Jwa, Yoon-Seok
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.1137-1139
    • /
    • 2003
  • This paper proposed a practical method for building detection and extraction using airborne laser scanning data. The proposed method consists mainly of two processes: low and high level processes. The major distinction from the previous approaches is that we introduce a concept of pseudogrid (or binning) into raw laser scanning data to avoid the loss of information and accuracy due to interpolation as well as to define the adjacency of neighboring laser point data and to speed up the processing time. The approach begins with pseudo-grid generation, noise removal, segmentation, grouping for building detection, linearization and simplification of building boundary , and building extraction in 3D vector format. To achieve the efficient processing, each step changes the domain of input data such as point and pseudo-grid accordingly. The experimental results shows that the proposed method is promising.

  • PDF

Development of confocal scanning microscopy using acousto-optica1 deflector

  • J.W. Seo;D.K. Kang;H.G. Yun;Kim, K.H.;D.G. Gweon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.161.6-161
    • /
    • 2001
  • Confocal scanning microscopy (CSM) has an important role as the three-dimensional profiler. An image distribution can be reconstructed by a correlation analysis of spots with the bandwidth of radio frequency. But it is a serious problem for the high performance to align the optical components. Especially, the parasitic motion of focus on the detector gives rise to the fatal distortion of an image profile named the extinction effect while using acousto-optical(AO) deflector. An image profile can be regenerated in CSM with many advantages of non-contact, high speed and high resolution comparatively. In addition to the axial response of the primary focus, the lateral movement of it gives a necessity of the unitary lens to the scanning system. While using the beam deflector, the pupil of beam may be fixed at the nominal position. Furthermore, the use of a deflector may result in ...

  • PDF

다구찌 방법을 이용한 레이저 포토리소그라피 미세패턴가공 기술의 최적화 (Optimization of Laser Photolithography Micromachining Technique based on Taguchi Method)

  • 백남국;김대은
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.871-875
    • /
    • 2001
  • Laser photolithography technique is useful for fabricating micro-patterns of silicon wafers. In this work, the laser photolithography micromachining technique is optimized based on Taguchi method. Sensitivity analysis was performed using laser scanning speed and laser power level as the parameters. The results show that for the photoresist used in this work, a laser scan speed of $70{\mu}m/s$ at 50mW laser power gives the best result.

  • PDF

갈바노미터 스캐너를 이용한 레이저 마킹 시스템 설계 제작에 관한 연구 (A study on the design of the laser marking system using galvanometer scanner)

  • 조태익;이건이
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1986년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 17-18 Oct. 1986
    • /
    • pp.145-148
    • /
    • 1986
  • To perform the marking on metal with high speed and non-contact using the laser beam of high energy, laser marking system is designed and fabricated applying the galvanometer scanner capable of high speed-precise beam positioning controlled by microprocessor. Laser is a Q-switched Nd:YAG producing multi-mode, wavelength, 1060nm. Optical system is composed of beam expander, scanning mirror and flat field lens. Consequently, the laser marking is satisfactorily achieved regardless of kinds of metal.

  • PDF