• 제목/요약/키워드: Scanning probe

검색결과 588건 처리시간 0.021초

A Multi-Step Digitizing Method and Reverse Model Generation for Improvement of Reverse Engineering Accuracy (역공학의 정밀도 향상을 위한 점 데이터의 다단계 획득 및 역모델 형성)

  • 김권흡;장경열;유우식;박정환;고태조;배석형
    • Korean Journal of Computational Design and Engineering
    • /
    • 제8권3호
    • /
    • pp.133-140
    • /
    • 2003
  • This paper describes a Multi-step Digitizing Method and Reverse Model generation algorithm for improvement of reverse engineering accuracy. Reverse engineering is the process of reproducing computational model by directly extracting geometric information on the physical objects. For the improvement of measuring data accuracy, we propose a multi-step digitizing method. First, measuring cloud-of-point by use of a laser scanning system. Second, gathering digitizing data by a scanning touch probe. Fine digitizing plan generated from coarse surface model directly from the cloud-of-point and it allows CMM more accurate scanning data. Finally in this paper we propose the algorithm of generating NURB surface from more accurate measuring points.

Theoretical Study of Scanning Probe Microscope Images of VTe2

  • Park, Sung-Soo;Lee, Jee-Young;Lee, Wang-Ro;Lee, Kee-Hag
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권1호
    • /
    • pp.81-84
    • /
    • 2007
  • Ab initio periodic Hartree-Fock calculations with the full potential and minimum basis set are applied to interpretation of scanning tunneling microscope (STM) and atomic force microscope (AFM) images on 1TVTe2. Our results show that the simulated STM image shows asymmetry while the simulated AFM image shows the circular electron densities at the bright spots without asymmetry of electron density to agree with the experimental AFM image. The bright spots of both the STM and AFM images of VTe2 are associated with the surface Te atoms, while the patterns of bright spots of STM and AFM images are different.

Nano-Scale Surface Observation of Cyclically Deformed Copper and Cu-Al Single Crystals (반복변형된 Cu 및 Cu-Al 단결정 표면형상의 나노-스케일 관찰)

  • 최성종;이권용
    • Tribology and Lubricants
    • /
    • 제16권5호
    • /
    • pp.389-394
    • /
    • 2000
  • Scanning Probe Microscope (SPM) such as Scanning Tunneling Microscope (STM) and Atomic Force Microscope (AEM) was shown to be the powerful tool for nano-scale characterization of material surfaces. Using this technique, surface morphology of the cyclically deformed Cu or Cu-Al single crystal was observed. The surface became proportionately rough as the number of cycles increased, but after some number of cycles no further change was observed. Slip steps with the heights of 100 to 200 nm and the widths of 1000 to 2000 nm were prevailing at the stage. The slipped distance of one slip system at the surface was not uniform, and formation of the extrusions or intrusions was assumed to occur such place. By comparing the morphological change caused by crystallographic orientation, strain amplitude, number of cycles or stacking fault energy, some interesting results which help to clarify the basic mechanism of fatigue damage were obtained. Furthermore, applicability of the scanning tunneling microscopy to fatigue damage is discussed.

A Study on the Current-voltage Properties of Dipyridinium Molecule using Scanning Tunneling Microscopy (STM에 의한 Dipyridinium 유기분자의 전압-전류 특성 연구)

  • Lee, Nam-Suk;Shin, Hoon-Kyu;Chang, Jeong-Soo;Kwon, Young-Soo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제18권7호
    • /
    • pp.622-627
    • /
    • 2005
  • In this study, electrical properties of self-assembled dipyridinium dithioacetate molecule onto the Au(111) substrate is observed using Scanning Tunneling Microscopy(STM) by vortical structure of STM probe. At first, the Au(111) substrate is cleaned by piranha solution$(H_2SO_4:H_2O_2\;=\;3:1)$. Subsequently, 1 mM/ml of dipyridinium dithioacetate molecule is self-assembled onto the Au(111) surface. Using STM, the images of dipyridinium dithioacetate molecule which is self-assembled onto the Au(111) substrate, can be observed. In addition, the electrical properties(I-V) of dipyridinium dithioacetate can also be examined by using Scanning Tunneling Spectroscopy(STS). From the results of the measurement of the current-voltage(I-V), the property of Negative Differential Resistance(NDR) that shows the decreases of current according to the increases of voltage is observed. We found the NDR voltage of the dipyridinium dithioacetate is -1.42 V(negative region) and 1.30 V(positive region), respectively.

Assessment of Uterine Internal Temperature according to the Time of Convex Probe Injection using a Self-made Uterine Model Phantom (자체 제작한 자궁모형팬텀을 이용한 Convex probe 주사시간에 따른 자궁내부온도 평가)

  • Lee, Hyun-Kyung;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • 제13권6호
    • /
    • pp.895-900
    • /
    • 2019
  • Ultrasound is known to be harmless to the human body and is widely used in obstetrics and gynecology to confirm the diagnosis and development status of fetus. Diagnosis Although long - term use of ultrasound may cause changes in body temperature, studies on the uterine temperature changes due to ultrasound have been lacking. The purpose of this study was to investigate the change of temperature according to ultrasonic scanning time using a self - produced uterine model phantom. Ultrasound equipment and a 4MHz convex probe were used to construct the uterine model phantom similar to the human uterus using acrylic and pig uterus, which are tissue equivalents. Three probe type thermometers were installed to measure the inside of the acrylic water tank, the uterus, and the atmospheric temperature. The temperature of the uterine phantom was ascertained by measuring the temperature of the subject for 6 hours, 361 times. In this study, the possibility of human body temperature elevation due to ultrasound could be confirmed and this study will be used as the basic data of ultrasonic heat absorption study.

Optimal Electron Beam Characteristics by Lenses Analysis Using Scanning Electron Microscopy (주사전자현미경 렌즈의 해석을 통한 최적의 빔 특성 연구)

  • Bae, Jinho;Kim, Dong Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제39권1호
    • /
    • pp.1-9
    • /
    • 2015
  • This paper presents a design method for optimizing the focused beam characteristics, which are mainly determined by the condenser lenses in a scanning electron microscopy (SEM) design. Sharply reducing the probe diameter of electron beams by focusing the condenser lens (i.e., the rate of condensation) is important because a small probe diameter results in high-performance demagnification. This study explored design parameters that contribute to increasing the SEM resolution efficiently using lens analysis and the ray tracing method. A sensitivity analysis was conducted based on those results to compare the effects of these parameters on beam focusing. The results of this analysis on the design parameters for the beam characteristics can be employed as basic key information for designing a column in SEM.

Analysis of the local superconducting properties in YBCO coated conductors with striations

  • Kim, Muyong;Park, Sangkook;Park, Heeyeon;Ri, Hyeong-Cheol
    • Progress in Superconductivity and Cryogenics
    • /
    • 제17권2호
    • /
    • pp.25-30
    • /
    • 2015
  • In order to realize economical applications, it is important to reduce the ac loss of 2G high-temperature superconductor coated conductors. It seems to be reasonable that a multi-filamentary wire can decrease the magnetization loss. In this study, we prepared two samples of YBCO coated conductors with striations. We measured local superconducting properties of both samples by using Low Temperature Scanning Laser and Hall Probe Microscopy (LTSLHPM). The distribution of the local critical temperature of samples was analyzed from experimental results of Low Temperature Scanning Laser Microscopy (LTSLM) near the superconducting transition temperature. According to LTSLM results, spatial distributions of the local critical temperature of both samples are homogeneous. The local current density and the local magnetization in samples were explored from measuring stray fields by using Scanning Hall Probe Microscopy (SHPM). From SHPM results, the remanent field pattern of the one bridge sample in an external magnetic field confirms the Bean's critical state model and the three bridge sample has similar remanent field pattern of the one bridge sample. The local magnetization curve in the three bridge sample was measured from external fields from -500 Oe to 500 Oe. We visualized that the distribution of local hysteresis loss are related in the distribution of the remanent field of the three bridge sample. Although the field dependence of the critical current density must be taken into account, the relation of the local hysteresis loss and the remanent field from Bean's model was useful.

A STUDY OF CO2 LASER IRRADIATED DENTAL HARD TISSUES USING ELECTRON PROBE MICROANALYZER AND SCANNING ELECTRON MICROSCOPE (CO2레이저 조사가 치아경조직에 미치는 영향에 관한 EPMA분석 및 주사전자현미경적 연구)

  • Chang, Gye-Bong;Lee, Chung-Suck;Lee, Chan-Young;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • 제12권1호
    • /
    • pp.51-64
    • /
    • 1986
  • The purpose of this study is to obtain the data of prestep in cavity preparation by observing changed conditions of laser irradiated dental hard tissues. The forty five extracted caries free human molars were divided into three groups and each group into five subgroups. A $CO_2$ laser irradiation was performed each subgroup of group I for one second with output power of 5 W, 10 Wand 20 W. On group II, laser irradiation was done ten times for 0.1 second duration using same power ratings as group I. On group III, laser irradiation was done 0.1 second, 0.2 second and 0.4 second with output power of 50 W. We investigated mineral contents and crater wall of obtained specimens, i.e., laser irradiated teeth, using computer controlled electron probe microanalyzer and scanning electron microscope. The following results were obtained: 1. Both calcium and phosphorus contents in laser irradiated enamel crater wall were increased, and magnesium content was decreased, but these trends were not statistically significant. 2. In laser irradiated dentin, change of mineral content was more significant. 3. In laser irradiated enamel and dentin, there were no significant differences on mineral content change due to irradiation condition and energy density. 4. In scanning electron microscopic study, enamel rods of the crater wall were fused and clefts were observed in parallel with the direction of enamel rod for all groups. 5. In laser irradiated dentin, irregular fusion and clefts were observed. In irradiated teeth with high power and short duration, the locally formed narrow crater wall was observed.

  • PDF

Microstructure Evolution and Properties of Silicides Prepared by dc-sputtering (스퍼터링으로 제조된 니켈실리사이드의 미세구조 및 물성 연구)

  • An, Yeong-Suk;Song, O-Seong;Lee, Jin-U
    • Korean Journal of Materials Research
    • /
    • 제10권9호
    • /
    • pp.601-606
    • /
    • 2000
  • Nickel mono-silicide(NiSi) shows no increase of resistivity as the line width decreases below 0.15$\mu\textrm{m}$. Furthermore, thin silicide can be made easily and restrain the redistribution of dopants, because NiSi in created through the reaction of one nickel atom and one silicon atom. Therefore, we investigated the deposition condition of Ni films, heat treatment condition and basic properties of NiSi films which are expected to be employed for sub-0.15$\mu\textrm{m}$ class devices. The nickel silicide film was deposited on the Si wafer by using a dc-magnetron sputter, then annealed at the temperature range of $150~1000^{\circ}C$. Surface roughness of each specimen was measured by using a SPM (scanning probe microscope). Microstructure and qualitative composition analysis were executed by a TEM-EDS(transmission electron microscope-energy dispersive x-ray spectroscope). Electrical properties of the materials at each annealing temperature were measured by a four-point probe. As the results of our study, we may conclude that; 1. SPM can be employed as a non-destructive process to monitor NiSi/NiSi$_2$ transformation. 2. For annealing temperature over $800^{\circ}C$, oxygen pressure $Po_2$ should be kept below $1.5{\times}10^{-11}torr$ to avoid oxidation of residual Ni. 3. NiSi to $NiSi_2$ transformation temperature in our study was $700^{\circ}C$ from the four-point probe measurement.

  • PDF

Study on Characteristics of Eddy Current Array Coil Operated in Transmit-Receive Mode and Surface Inspection Using This Probe (송수신 모드 배열 코일 와전류 탐촉자의 특성 연구 및 이를 이용한 표면검사)

  • Lee, Tae-Hun;Jee, Dong-Hyun;Cho, Chan-Hee;Kim, In-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • 제37권1호
    • /
    • pp.21-28
    • /
    • 2017
  • Eddy current array (ECA) technology provides the ability to electronically scan without mechanical scanning for a footprint of probe that consists of several eddy current coils arranged side-by-side and two dimensionally. Compared to single-coil eddy current technology, the ECA technology has a higher inspection speed and reliability because a large area can be covered in a single-probe pass and the obtained images can facilitate data interpretation. In this study, we developed an eddy current array probe with $2{\times}16$ coil arrays and a multiplexer that can select transmit-receive coils sequentially and operate in transmit-receive mode. Surface inspection was performed using this probe for specimens that had various flaws and the characteristics of transmit-receive mode ECA technology was studied through an analysis of the obtained eddy current signals and C-scan images.