• Title/Summary/Keyword: Scanning Path

Search Result 154, Processing Time 0.032 seconds

Morphological Study on the Soot Transition in a Propane/Air Laminar Diffusion Flame (프로판 층류확산화염의 그을음 천이에 대한 형태학적 연구)

  • Shim, Sung-Hoon;Yoo, Chang-Jong;Shin, Hyun-Dong
    • Journal of the Korean Society of Combustion
    • /
    • v.7 no.2
    • /
    • pp.24-33
    • /
    • 2002
  • The morphology of deposits on $15-{\mu}m$ thin SiC filaments has been investigated with SEM in a co-flowing, propane/air laminar diffusion flame. The average size of mature soot particles deposited in the luminous flame edge is strongly dependent on their axial position in a typical heavily sooting flame. The surface growth of liquid-phase PAHs molecules and the transition to soots from fully-developed precursors could be observed in the radial deposition of the flame. Two sooting regimes were found: one is the transition from the condensed-phase precursors; the other is the aggregation of smaller soot particles (or chains of them) to be carried along particle path lines. In the high temperature flame edge outside the soot luminous flame surface, the very thin fiber-like structures, which are about 10 nm thick, were found.

  • PDF

Thermal Characteristics Analysis of Pre-Treated Rayon Fibers for Preparing Activated Carbon Fibers (활성탄소섬유 제조시 전처리된 레이온 섬유의 열특성 분석)

  • Choi, Sang Seun;Lee, Soon Hong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.61-72
    • /
    • 2014
  • The aim of this study is to define the condition of optimal pre-treatment for preferable activated carbon fibers (ACFs), which are based on rayon fibers. This paper shows the ideal path of ACFs preparation process; implies that rayon fibers are pre-treated by various solvents with different times before the heating process. The pre-treated rayon fibers finally turned into desirable rayon fiber-based ACFs through optimal pre-treatment condition by heating processes. The thermal analysis method of pre-treated rayon fibers by thermo-gravimetry analyser (TGA) is an idealized tool, which analyzes the best thermal condition of pre-treatment process. Surface morphologies of resulting rayon fibers based ACFs were examined by scanning electron microscope(SEM). The results of TGA and SEM analyses show that the optimal pre-treatment condition for preparing ACFs was clearly defined, in terms of thermal stability and surface morphology.

Object Classification Method using Hilbert Scanning Distance (힐버트 스캔 거리값을 이용한 물체식별 알고리즘)

  • Choi, Jeong-Hwan;Baek, Young-Min;Choi, Jin-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.4
    • /
    • pp.700-705
    • /
    • 2008
  • In this paper, we propose object classification algorithm for real-time surveillance system. We have approached this problem using silhouette-based template matching. The silhouette of the object is extracted, and then it is compared with representative template models. Template models are previously stored in the database. Our algorithm is similar to previous pixel-based template matching scheme like Hausdorff Distance, but we use 1D image array rather than 2D regions inspired by Hilbert Path. Transformation of images could reduce computational burden to compute similarity between the detected image and the template images. Experimental results show robustness and real-time performance in object classification, even in low resolution images.

Electrochemical Studies on the Mechanism of the Fabrication of Ceramic Films by Hydrothermal-Electrochemical Technique

  • Zhibin Wu;Masahiro Yoshimura
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.8
    • /
    • pp.869-874
    • /
    • 1999
  • In this paper, electrochemical techniques are used to investigate hydrothermal-electrochemically formation of barium titanate (BT) ceramic films. For comparison, the electrochemical behaviors of anodic titanium oxide films formed in alkaline solution were also investigated both at room temperature and in hydrothermal condition at 150.0 ℃. Film structure and morphology were identified by scanning electron microscopy (SEM) and atomic force microscopy (AFM). Titanium oxide films produced at different potentials exhibit different film morphology. The breakdown of titanium oxide films anodic growth on Ti electrode plays an important roles in the formation of BT films. BT films can grow on anodic oxide/metal substrate interface by short-circuit path, and the dissolution-precipitation processes on the ceramic film/solution interface control the film structure and morphology. Based upon the current experimental results and our previous work, extensively schematic proce-dures are proposed to model the mechanism of ceramic film formation by hydrothermal-electrochemical method.

Holographic tomography: hardware and software solutions for 3D quantitative biomedical imaging (Invited paper)

  • Kus, Arkadiusz;Krauze, Wojciech;Makowski, Piotr L.;Kujawinska, Malgorzata
    • ETRI Journal
    • /
    • v.41 no.1
    • /
    • pp.61-72
    • /
    • 2019
  • In this paper, we demonstrate the current concepts in holographic tomography (HT) realized within limited angular range with illumination scanning. The presented solutions are based on the work performed at Warsaw University of Technology in Poland and put in context with the state of the art in HT. Along with the theoretical framework for HT, the optimum reconstruction process and data visualization are described in detail. The paper is concluded with the description of hardware configuration and the visualization of tomographic reconstruction, which is calculated using a provided processing path.

3D Ground Terrain Processing Platform for Automated Excavation System

  • Kim, Seok;Kim, Tae-yeong;Park, Jae-Woo
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.669-670
    • /
    • 2015
  • Efficient management of the construction heavy equipment is required to reduce the rate of carbon emissions and on-site accidents. The intelligent excavation system (IES) will improve the construction quality and productivity through information technologies and efficient equipment operation, especially in large earthwork projects. Three-dimensional digitized ground data should be required for identifying the path of heavy equipment and work-site environment. Rapid development of terrain laser scanners (TLS) is more readily to acquire the digital data. This study suggests the '3D ground terrain processing platform (3DGTPP)' including data manipulating module and analyzing module of the scanned data for intelligent earthmoving equipment operation. The processing platform consists of six modules, including scanning, registering, manipulating, analyzing, transmitting, and storing. 3D ground terrain processing platform presented in this study will provide fundamental information for intelligent excavation system (IES), which will increase the efficiency of earthworks and safety of workers in significant.

  • PDF

A Monte Carlo Simulation Study of a Therapeutic Proton Beam Delivery System Using the Geant4 Code (Geant4 몬테카를로 코드를 이용한 양성자 치료기 노즐의 전산모사)

  • Shin, Jungwook;Shim, Hyunha;Kwak, Jungwon;Kim, Dongwook;Park, Sungyong;Cho, Kwan Ho;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.18 no.4
    • /
    • pp.226-232
    • /
    • 2007
  • We studied a Monte Carlo simulation of the proton beam delivery system at the National Cancer Center (NCC) using the Geant4 Monte Carlo toolkit and tested its feasibility as a dose verification framework. The Monte Carlo technique for dose calculation methodology has been recognized as the most accurate way for understanding the dose distribution in given materials. In order to take advantage of this methodology for application to external-beam radiotherapy, a precise modeling of the nozzle elements along with the beam delivery path and correct initial beam characteristics are mandatory. Among three different treatment modes, double/single-scattering, uniform scanning and pencil beam scanning, we have modeled and simulated the double-scattering mode for the nozzle elements, including all components and varying the time and space with the Geant4.8.2 Monte Carlo code. We have obtained simulation data that showed an excellent correlation to the measured dose distributions at a specific treatment depth. We successfully set up the Monte Carlo simulation platform for the NCC proton therapy facility. It can be adapted to the precise dosimetry for therapeutic proton beam use at the NCC. Additional Monte Carlo work for the full proton beam energy range can be performed.

  • PDF

Volumetrical changes of liver associated with breathing and its impact to normal tissue complication probability (호흡에 따른 간장용적의 변화와 정상조직손상확율에 미치는 영향에 관한 연구)

  • Cho Jung Hee;Kim Joo Ho;Lee Suk;Park Je Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.13 no.1
    • /
    • pp.14-22
    • /
    • 2001
  • Purpose: The aim of this study is to investigate geometrical and volumetrical changes of liver due to breathing and its impact to NTCP. In order to attain better treatment results it should be considered deliberately during planning session. Mehtods and Materials : Seven patients were examined in this study who have done TACE for accurate tumor margin drawing. After contrast media injection, C-T scan data were obtained in supine position during breathing free, inhalation and exhalation, respectively. For all patients C-T scan were done with same scanning parameters- 5 mm index, 5 mm thickness and pitch 1. Based on C-T data we have measured differences of each variables between breathing status such as changes of total and remained liver volumes, GTV, beam path length and superior to inferior shift. NTCP were calculated using Lyman's effective volume DVH reduction scheme and for this NTCP calculation, the V50 was computed from DVH and each m, n value were referred from Burmans data. Results : The measured total tilter volume and the remained liver volume changed between inspiration and expiration about $1.2-7.7\%(mean+2.7\%)$ and $2.5-13.23\%(mean=5.8\%)$ respectively, and these results were statistically significant(p>0.1). The GTV difference in each patient varied widely from $1.17\%\;to\;30.69\%$, but this result was not statistically significant. Depending on the breathing status, the beam path length was changed from 0.5 cm to 1.1 cm with the average of 0.7 cm, and it was statistically significant(p=0.006). The measured superior to inferior shifts were ranged from 0.5 cm to 3.74 cm. The NTCPs were changed relatively small in each patient, but the variation was large between the patients. The mean NTCP difference was $10.5\%$, with the variation ranged from $7\%\;to\;23.5\%$. Conclusion : Variations of liver volume and of beam path length were changed significantly depending on the breathing statues and the range of variation itself was very different between the patients. Since this variance could seriously affect the clinical outcomes of radiation treatments, the breathing of patients need to be accounted when a final treatment planning is derided.

  • PDF

Enzymatic Synthesis of Diacylglycerol Oil from Glyceryl Mono-oleate and Conjugated Linoleic Acid Using a Stirred-Batch Type Reactor (회분식 반응기를 이용한 Glyceryl Monooleate와 Conjugated Linoleic Acid로부터 효소적 반응을 통한 디글리세롤 유지의 합성)

  • Jeon, Mi-Sun;Lee, Ki-Teak
    • Food Science and Preservation
    • /
    • v.16 no.2
    • /
    • pp.246-252
    • /
    • 2009
  • Diacylglycerol(DAG) was produced by enzymatic esterification of glyceryl mono-oleate(GMO) and conjugated linoleic acid(CLA) in a stirred-batch type reactor. The reaction was catalyzed by lipozyme RMIM(an immobilized lipase from Rizomucor miehei). DAG was isolated by a short-path distillation process and decolorized. DAG oil was composed of 87.3% DAG, 11.4% triacylglycerol(TAG), and 1.5% monoacylglycerol(MAG)(all w/w). Major fatty acids in DAG oil were oleic acid(54%), CLA(31.1%), and linoleic acid(7%). DAG oil iodine,and acid values were 108.8, 2.57, and 1, respectively. The DAG oil solid fat index(SFI) and thermograms were obtained using differential scanning calorimetry.

Simulation of lesion-to-liver contrast difference curves in Dynamic Hepatic CT with Pharmacokinetic Compartment Modeling (Pharmacokinetic Compartment Modeling을 이용한 나선식 CT 에서의 간암-간 대조 곡선의 Simulation)

  • Kim, S.J.;Lee, K.H.;Kim, J.H.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.271-272
    • /
    • 1998
  • Contrast-enhanced CT has an important role in the assessment of liver lesions. However, the optimal protocol to get most effective result is not clear. The main principle for deciding injection protocol is to optimize lesion detectability by rapid scanning when lesion-to-liver contrast is maximum. For this purpose, we developed a physiological model of contrast medium enhancement based on the compartment modeling and pharmacokinetics. Blood supply to liver was modeled in two paths. This dual supply character distinguishes the CT enhancement of liver from that of the other organs. The first path is by hepatic artery and the second is by portal vein. It is assumed that only hepatic artery can supply blood to hepatocellular carcinoma (HCC) compartment. It is known that this causes the difference of contrast enhancement between normal liver tissue and hepatic tumor. By solving differential equations for each compartment simultaneously using computer program Matlab, CT contrast-enhancement curves were simulated. Simulated enhancement curves for aortic, hepatic, portal vein, and HCC compartments were compared with mean enhancement curves from 24 patients exposed to the same protocols as simulation. These enhancement curves were in a good agreement. Furthermore, we simulated lesion-to-liver curves for various injection protocols, and analyzed the effects. These may help to optimize the scanning protocols for good diagnosis.

  • PDF