• Title/Summary/Keyword: Scanning Image

Search Result 1,090, Processing Time 0.028 seconds

Factors Affecting the Intention to use the Favorite Channel Function: Focusing on Innate Innovativeness and Perceived Characteristics of Innovation, Viewing Behavior, and Social Influence (TV 북마킹으로서 TV 선호채널 설정기능 이용의도에 영향을 미치는 요인: 개혁성, 개혁의 특성, 시청행태 및 사회적 영향을 중심으로)

  • Lim, Hong-Gab;Chang, Byeng-Hee;Nam, Sang-Hyun;Baek, Sang-Ki
    • Korean journal of communication and information
    • /
    • v.58
    • /
    • pp.154-177
    • /
    • 2012
  • Considering the growing importance of TV favorite channel setting function due to the rapid increase of number of TV channels, this study tried to find factors which affect the attitude toward and intention to use the favorite channel setting function. As related theories, this study used theory of diffusion of innovation, channel repertoire, channel changing behaviors, and social influences and suggested research hypotheses and questions based on the theories. After collecting data through online survey of 192 general audience, this study empirically analyzed the data by using multiple regression analysis. The result showed that innate innovativeness, relative advantage and social critical mass affected attitude toward using the favorite channel setting function and that compatibility, visibility, social critical mass influenced intention to use the function.

  • PDF

Cell attachment and proliferation of bone marrow-derived osteoblast on zirconia of various surface treatment

  • Pae, Ahran;Lee, Heesu;Noh, Kwantae;Woo, Yi-Hyung
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.96-102
    • /
    • 2014
  • PURPOSE. This study was performed to characterize the effects of zirconia coated with calcium phosphate and hydroxyapatite compared to smooth zirconia after bone marrow-derived osteoblast culture. MATERIALS AND METHODS. Bone marrow-derived osteoblasts were cultured on (1) smooth zirconia, (2) zirconia coated with calcium phosphate (CaP), and (3) zirconia coated with hydroxyapatite (HA). The tetrazolium-based colorimetric assay (MTT test) was used for cell proliferation evaluation. Scanning electron microscopy (SEM) and alkaline phosphatase (ALP) activity was measured to evaluate the cellular morphology and differentiation rate. X-ray photoelectron spectroscopy (XPS) was employed for the analysis of surface chemistry. The genetic expression of the osteoblasts and dissolution behavior of the coatings were observed. Assessment of the significance level of the differences between the groups was done with analysis of variance (ANOVA). RESULTS. From the MTT assay, no significant difference between smooth and surface coated zirconia was found (P>.05). From the SEM image, cells on all three groups of discs were sporadically triangular or spread out in shape with formation of filopodia. From the ALP activity assay, the optical density of osteoblasts on smooth zirconia discs was higher than that on surface treated zirconia discs (P>.05). Most of the genes related to cell adhesion showed similar expression level between smooth and surface treated zirconia. The dissolution rate was higher with CaP than HA coating. CONCLUSION. The attachment and growth behavior of bone-marrow-derived osteoblasts cultured on smooth surface coated zirconia showed comparable results. However, the HA coating showed more time-dependent stability compared to the CaP coating.

Current Status of KMTNet/DEEP-South Collaboration Research for Comets and Asteroids Research between SNU and KASI

  • BACH, Yoonsoo P.;YANG, Hongu;KWON, Yuna G.;LEE, Subin;KIM, Myung-Jin;CHOI, Young-Jun;Park, Jintae;ISHIGURO, Masateru;Moon, Hong-Kyu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.82.2-82.2
    • /
    • 2017
  • Korea Microlensing Telescope Network (KMTNet) is one of powerful tools for investigating primordial objects in the inner solar system in that it covers a large area of the sky ($2{\times}2$ degree2) with a high observational cadence. The Deep Ecliptic Patrol of the Southern sky (DEEP-South) survey has been scanning the southern sky using KMTNet for non-bulge time (45 full nights per year) [1] since 2015 for examining color, albedo, rotation, and shape of the solar system bodies. Since 2017 January, we have launched a new collaborative group between Korea Astronomy and Space Science Institute (KASI) and Seoul National University (SNU) with support from KASI to reinforce mutual collaboration among these institutes and further to enhance human resources development by utilizing the KMTNet/DEEP-South data. In particular, we focus on the detection of comets and asteroids spontaneously scanned in the DEEP-South for (1) investigating the secular changes in comet's activities and (2) analyzing precovery and recovery images of objects in the NASA's NEOWISE survey region. In this presentation, we will describe our scientific objectives and current status on using KMTNet data, which includes updating the accuracy of the world coordinate system (WCS) information, finding algorithm of solar system bodies in the image, and doing non-sidereal photometry.

  • PDF

The Difference of Cortical Activation Pattern According to Motor Learning in Dominant and Non.dominant Hand: An fMRI Case Study (우성과 비우성 손에서의 운동학습으로 나타나는 뇌 활성도 차이: fMRI 사례 연구)

  • Park, Ji-Won;Jang, Sung-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.1
    • /
    • pp.81-87
    • /
    • 2009
  • Purpose: Human brain was lateralized to dominant or non-dominant hemisphere, and could be reorganized by the processing of the motor learning. We reported four cases which showed the changes of the cortical activation patterns resulting from two weeks of training with the serial reaction time task. Methods: Four right-handed healthy subjects were recruited, who was equally divided to two training conditions (right hand training or left hand training). They were assigned to train the serial reaction time task for two weeks, which should press the corresponding four colored buttons as fast as accurately as possible when visual stimulus was presented. Before and after two weeks of training, reaction time and function magnetic resonance image (fMRI) was acquired during the performance of the same serial reaction time task as the training. Results: The reaction time was significantly decreased in all of subjects after training. Our fMRI result showed that widespread bilateral activation at the pre scanning was shifted toward the focused activation on the contralateral hemisphere with progressive motor learning. However, the bilateral activation was still remained during the performance of the non-dominant hand. Conclusion: These findings showed that the repetitive practice of the serial reaction time task led to increase the movement speed and accuracy, as described by motor learning. Such motor learning induced to change the cortical activation pattern. And, the changed pattern of the cortical activation resulting from motor learning was different each other in accordance with the hand dominance.

  • PDF

Determination of an Test Condition for IR Thermography to Inspect a Wall-Thinning Defect in Nuclear Piping Components (원전 배관 감육 결함 검사를 위한 IR 열화상시험 조건 결정)

  • Kim, Jin-Weon;Yun, Won-Kyung;Jung, Hyun-Chul;Kim, Kyeong-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.1
    • /
    • pp.12-19
    • /
    • 2012
  • This study conducted infrared (IR) thermography tests using pipe and plate specimens with artificial wall-thinning defects to find an optimal condition for IR thermography test on the wall-thinned nuclear piping components. In the experiment halogen lamp was used to heat the specimens. The distance between the specimen and the lamp and the intensity of halogen lamp were regarded as experimental parameter. When the distance was set to 1~2 m and the lamp intensity was above 60 % of full power, a single scanning of IR thermography detected all artificial wall-thinning defects, whose minimum dimension was $2{\Theta}=90^{\circ}$, d/t=0.5, and $L/D_o=0.25$, within the pipe of 500 mm in length. Regardless of the distance between the specimen and the lamp, the image of wall-thinning defect in IR thermography became distinctive as the intensity of halogen lamp increased. The detectability of IR thermography was similar for both plate and pipe specimens, but the optimal test condition for IR thermography depended on the type of specimen.

Adsorption of methylene blue from an aqueous dyeing solution by use of santa barbara amorphous-15 nanostructure: Kinetic and isotherm studies

  • Alizadeh, Reza;Zeidi, Amir
    • Advances in environmental research
    • /
    • v.6 no.2
    • /
    • pp.113-125
    • /
    • 2017
  • Santa Barbara Amorphous-15(SBA-15) nanoparticles were utilized as the inexpensive and effective adsorbents to remove methylene blue dye from the aqueous solution.SBA-15 was created by Zhao et al method. Infrared spectroscopy, X-ray diffraction and scanning electron microscopy (SEM) were used for the evaluated physical properties of SBA-15. The results of diffraction X-ray indicated that was the crystalline structure for it. Also IR spectroscopy indicated was a silica the whole structure of the groups and SEM image verify the structure of relatively identical particles size of SBA-15. Factors affecting adsorption including the amounts of adsorbent, pH and contact time were investigated by a SBA-15 nanomaterial design. The extent of dye removal enhanced with increasing initial dye concentration and pH from 4 to 10. The higher percentage adsorption were obtained under optimum conditions of variables (sorbent dose of 200 mg/liter, initial MB concentration 10 mg/liter, initial pH of 10 and temperature of $25^{\circ}C$). Maximum adsorption happened after the 2 hour and the kinetic processes of the dyes adsorption were described by applying the pseudo-first-order and the pseudo-second-order and the relatively High correlation with the kinetic Ellovich models. It was found that the pseudo-second-order models kinetic equation described the data of dye adsorption with a good correlation (R2>0.999) which indicated chemisorption mechanism. Freundlich and Langmuir adsorption models were investigated in conditions of variables (adsorbent dose 0.01 gr/liter, MB concentration 10, 20, 30 mg/liter, pH of 4, 7, 10, contact time 90 min and temperature of $27^{\circ}C$). The adsorption data were represented by Langmuir isotherm model. These values are higher than the adsorption capacities of some other adsorbents that have recently been published in the literature.

A Study on Feasibility of the Phosphoric Paste Doping for Solar Cell using Newly Atmospheric Pressure Plasma Source (새로운 대기압 플라즈마 소스를 이용한 결정질 실리콘 태양전지 인(P) 페이스트 도핑에 관한 연구)

  • Cho, I-Hyun;Yun, Myoung-Soo;Jo, Tae-Hoon;Rho, Junh-Young;Jeon, BuII;Kim, In-Tae;Choi, Eun-Ha;Cho, Guang-Sup;Kwon, Gi-Chung
    • New & Renewable Energy
    • /
    • v.9 no.2
    • /
    • pp.23-29
    • /
    • 2013
  • Furnace and laser is currently the most important doping process. However furnace is typically difficult appling for selective emitters. Laser requires an expensive equipment and induces a structural damage due to high temperature using laser. This study has developed a new atmospheric pressure plasma source and research atmospheric pressure plasma doping. Atmospheric pressure plasma source injected Ar gas is applied a low frequency (a few 10 kHz) and discharged the plasma. We used P type silicon wafers of solar cell. We set the doping parameter that plasma treatment time was 6s and 30s, and the current of making the plasma is 70 mA and 120 mA. As result of experiment, prolonged plasma process time and highly plasma current occur deeper doping depth and improve sheet resistance. We investigated doping profile of phosphorus paste by SIMS (Secondary Ion Mass Spectroscopy) and obtained the sheet resistance using generally formula. Additionally, grasped the wafer surface image with SEM (Scanning Electron Microscopy) to investigate surface damage of doped wafer. Therefore we confirm the possibility making the selective emitter of solar cell applied atmospheric pressure plasma doping with phosphorus paste.

The Clinical Usefulness of Halo Sign on CT Image of Trauma Patients (2세 미만 소아의 경도 두부 외상 후 두개골 골절 및 두개내 병변의 위험 인자)

  • Jeong, Jong Il;Kim, Ah Jin;Shin, Dong Wun;Rho, Jun Young;Kim, Kyung Hwan;Kim, Hong Yong;Park, Jun Seok
    • Journal of Trauma and Injury
    • /
    • v.20 no.2
    • /
    • pp.83-89
    • /
    • 2007
  • Purpose: This research was performed to determine which clinical signs and symptoms of brain injury are sensitive indicators of skull fracture (SF) and intracranial injury (ICI) in head injured children. Methods: We conducted a prospective study of minor head trauma in children younger than 2 years of age for a 1-year period. Skull radiographs, brain computed tomography (CT), and data forms, including mechanism of injury, symptoms, physical findings, and hospital course, were completed for each child. Results: Of 137 study subjects, 17 (12.4%) had SF/ICI. Falls were the most common mechanism of injury, and heights of fall above 1 meter were associated with incidence of SF/ICI (p<0.05). Scalp abnormalities were not associated with incidence of SF/ICI. As for clinical symptoms, lethargy and a grouping of features (irritability & vomiting) were associated with incidence of SF/ICI (p<0.05). The incidence of seizure, loss of consciousness, vomiting, irritability, and scalp abnormality did not differ significantly between those with normal radiologic findings and those with SF/ICI. Among asymptomatic patients, 11 (14.5%) patients had SF/ICI, and among patients with normal scalp findings, 9 (12.7%) patients had SF/ICI. Conclusion: Clinical signs and symptoms, except for lethargy and a grouping of features (irritability & vomiting), were not sensitive predictors of SF/ICI. Nevertheless, SF/ICI occurred among normal children. In such a case, a liberal policy of CT scanning is warranted.

Influence of Atherosclerosis Risk Factors on Carotid Intima, Media, and Intima-Media thickness

  • Kim, Wuon-Shik;Bae, Jang-Ho;Jin, Seung-Hyun;Park, Yong-Ki;Noh, Gi-Yong;Hwang, Jae-Ho
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.4 no.2
    • /
    • pp.25-30
    • /
    • 2006
  • We intended to measure the IT, MT, and the IMT of carotid artery separately and tried to analyze the clinical significance. Two hundred and fifty consecutive patients (125 males, 125 females) underwent carotid artery scanning using high-resolution ultrasound. The images were off-line analyzed using B-mode ultrasound image processing, devised in our research. We measured the IT, MT, and IMT semi-automatically at the far wall of designated 1cm length of the right common carotid and calculated the average values over the 200 points. The IT (p < 0.05), MT (p < 0.05) as well as IMT (p < 0.01) of patients with atherosclerotic disease were significantly thicker than that of the patients without atherosclerotic disease. Patients with hypertension showed significantly thicker IT (p < 0.05), MT (p < 0.01), and IMT (p < 0.01) than that of the patients without hypertension. However, only IT was thicker in patients with smoking (p < 0.05) than that of the patients without smoking. Smoking was associated only with intima while hypertension was associated with the all three layer's thickness. This result suggests the atherosclerotic process can be different by cardiovascular risk factors.

  • PDF

Optimal Design and Implementation of 3D Shape Restoration System for Femto-second Laser Micromachining (펨토초 레이저 미세가공을 위한 3차원 형상 복원 시스템의 최적설계 및 구현)

  • Park, Jeong-Hong;Lee, Ji-Hong;Ko, Yun-Ho;Park, Young-Woo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.6 s.312
    • /
    • pp.16-26
    • /
    • 2006
  • In this paper, we propose a 3D shape restoration system which measures height and surface shape of transparent ITO glass and delivers errors in focal length and incident angle of laser beam to femto-second laser micromachining. The proposed system is composed of a line scan laser, a high resolution camera, a linear motion guide synchronized to image capturing, and a control station. Also, we define the sensitivity indices that represent a relation between measurement error and a position of a camera and scan laser, and utilize it for optimum design. The results of the proposed system are compared with results of SPM(Scanning Probe Microscope) and prove the usefulness of the system.