• Title/Summary/Keyword: Scanning Image

Search Result 1,090, Processing Time 0.033 seconds

Efficient Red-Color Emission of InGaN/GaN Double Hetero-Structure Formed on Nano-Pyramid Structure

  • Go, Yeong-Ho;Kim, Je-Hyeong;Gong, Su-Hyeon;Kim, Ju-Seong;Kim, Taek;Jo, Yong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.174-175
    • /
    • 2012
  • (In, Ga) N-based III-nitride semiconductor materials have been viewed as the most promising materials for the applications of blue and green light emitting devices such as light-emitting diodes (LEDs) and laser diodes. Although the InGaN alloy can have wide range of visible wavelength by changing the In composition, it is very hard to grow high quality epilayers of In-rich InGaN because of the thermal instability as well as the large lattice and thermal mismatches. In order to avoid phase separation of InGaN, various kinds of structures of InGaN have been studied. If high-quality In-rich InGaN/GaN multiple quantum well (MQW) structures are available, it is expected to achieve highly efficient phosphor-free white LEDs. In this study, we proposed a novel InGaN double hetero-structure grown on GaN nano-pyramids to generate broad-band red-color emission with high quantum efficiency. In this work, we systematically studied the optical properties of the InGaN pyramid structures. The nano-sized hexagonal pyramid structures were grown on the n-type GaN template by metalorganic chemical vapor deposition. SiNx mask was formed on the n-type GaN template with uniformly patterned circle pattern by laser holography. GaN pyramid structures were selectively grown on the opening area of mask by lateral over-growth followed by growth of InGaN/GaN double hetero-structure. The bird's eye-view scanning electron microscope (SEM) image shows that uniform hexagonal pyramid structures are well arranged. We showed that the pyramid structures have high crystal quality and the thickness of InGaN is varied along the height of pyramids via transmission electron microscope. Because the InGaN/GaN double hetero-structure was grown on the nano-pyramid GaN and on the planar GaN, simultaneously, we investigated the comparative study of the optical properties. Photoluminescence (PL) spectra of nano-pyramid sample and planar sample measured at 10 K. Although the growth condition were exactly the same for two samples, the nano-pyramid sample have much lower energy emission centered at 615 nm, compared to 438 nm for planar sample. Moreover, nano-pyramid sample shows broad-band spectrum, which is originate from structural properties of nano-pyramid structure. To study thermal activation energy and potential fluctuation, we measured PL with changing temperature from 10 K to 300 K. We also measured PL with changing the excitation power from 48 ${\mu}W$ to 48 mW. We can discriminate the origin of the broad-band spectra from the defect-related yellow luminescence of GaN by carrying out PL excitation experiments. The nano-pyramid structure provided highly efficient broad-band red-color emission for the future applications of phosphor-free white LEDs.

  • PDF

Ovarian and Endometrial $^{18}F$-FDG Uptake During the Menstrual Cycle in Normal Premenopausal Patients: Evaluation by PET/CT (월경주기에 따른 $^{18}F$-FDG PET/CT의 자궁 내 섭취에 관한 연구)

  • Bahn, Young-Kag;Park, Hoon-Hee;NamKoong, Hyuk;Kim, Sang-Kyoo;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.43-47
    • /
    • 2009
  • Purpose: The menstrual cycle of normal premenopausal patients was divide into menstrual flow phase, proliferative phase, ovulatory phase, secretory phase. The aim of this study was to ovarian and endometrial $^{18}F$-FDG uptake during the menstrual cycle in normal premenopausal patients. Materials and Methods: We identified 200 incidental $^{18}F$-FDG uptake in the ovary. The patient fasted at least 6 hours before receiving an intravenous injection of 370-592 MBq (10-16mCi) of $^{18}F$-FDG. Scanning from the base of the skull though the mid thigh was performed using the Discovery Ste PET/CT system (GE Healthcare, Milwaukee, WI, USA). Ovarian and endometrial $^{18}F$-FDG uptake (expressed as standardized uptake value) was measured on PET/CT image. Results: Two peaks of increased endometrial $^{18}F$-FDG uptake were identified during the menstrual cycle. The $SUV_{avg}$ and $SUV_{max}$ was $2.89{\pm}1.04$ and $3.17{\pm}1.59$ in menstruating patients, $2.4{\pm}0.88$ and $2.98{\pm}1.14$ in proliferative phase patients, $3.59{\pm}1.76$ and $3.17{\pm}1.67$ in ovulatory phase patients, $2.58{\pm}1.39$ and $3.1{\pm}1.8$ in secretory phase patients. Conclusions: Increased ovarian and endometrial $^{18}F$-FDG uptake could be found the time of menstrual flow and ovulatory phase of menstrual cycle. Increased uptake in endometrial adjacent to a cervical tumor does not necessarily reflect endometrial tumor invasion. Since increased uptake was dependent on the menstrual cycle, it can be avoided by scheduling PET/CT just after menstruation. Non-menstrual-related endometrial uptake may be instrumental in establishing a diagnosis in a premenopaual patient.

  • PDF

Physicochemical Characteristics and Varietal Improvement Related to Palatability of Cooked Rice or Suitability to Food Processing in Rice (쌀 식미 및 가공적성에 관련된 이화학적 특성)

  • 최해춘
    • Proceedings of the Korean Journal of Food and Nutrition Conference
    • /
    • 2001.12a
    • /
    • pp.39-74
    • /
    • 2001
  • The endeavors enhancing the grain quality of high-yielding japonica rice were steadily continued during 1980s∼1990s along with the self-sufficiency of rice production and the increasing demands of high-quality rices. During this time, considerably great, progress and success was obtained in development of high-quality japonica cultivars and qualify evaluation techniques including the elucidation of interrelationship between the physicochemical properties of rice grain and the physical or palatability components of cooked rice. In 1990s, some high-quality japonica rice caltivars and special rices adaptable for food processing such as large kernel, chalky endosperm aromatic and colored rices were developed and its objective preference and utility was also examined by a palatability meter, rapid-visco analyzer and texture analyzer. The water uptake rate and the maximum water absorption ratio showed significantly negative correlations with the K/Mg ratio and alkali digestion value(ADV) of milled rice. The rice materials showing the higher amount of hot water absorption exhibited the larger volume expansion of cooked rice. The harder rices with lower moisture content revealed the higher rate of water uptake at twenty minutes after soaking and the higher ratio of maximum water uptake under the room temperature condition. These water uptake characteristics were not associated with the protein and amylose contents of milled rice and the palatability of cooked rice. The water/rice ratio (in w/w basis) for optimum cooking was averaged to 1.52 in dry milled rices (12% wet basis) with varietal range from 1.45 to 1.61 and the expansion ratio of milled rice after proper boiling was average to 2.63(in v/v basis). The major physicochemical components of rice grain associated with the palatability of cooked rice were examined using japonica rice materials showing narrow varietal variation in grain size and shape, alkali digestibility, gel consistency, amylose and protein contents, but considerable difference in appearance and torture of cooked rice. The glossiness or gross palatability score of cooked rice were closely associated with the peak. hot paste and consistency viscosities of viscogram with year difference. The high-quality rice variety “Ilpumbyeo” showed less portion of amylose on the outer layer of milled rice grain and less and slower change in iodine blue value of extracted paste during twenty minutes of boiling. This highly palatable rice also exhibited very fine net structure in outer layer and fine-spongy and well-swollen shape of gelatinized starch granules in inner layer and core of cooked rice kernel compared with the poor palatable rice through image of scanning electronic mcroscope. Gross sensory score of cooked rice could be estimated by multiple linear regression formula, deduced from relationship between rice quality components mentioned above and eating quality of cooked rice, with high Probability of determination. The ${\alpha}$ -amylose-iodine method was adopted for checking the varietal difference in retrogradation of cooked rice. The rice cultivars revealing the relatively slow retrogradation in aged cooked rice were Ilpumbyeo, Chucheongbyeo, Sasanishiki, Jinbubyeo and Koshihikari. A Tongil-type rice, Taebaegbyeo, and a japonica cultivar, Seomjinbyeo, shelved the relatively fast deterioration of cooked rice. Generally, the better rice cultivars in eating quality of cooked rice showed less retrogiadation and much sponginess in cooled cooked rice. Also, the rice varieties exhibiting less retrogradation in cooled cooked rice revealed higher hot viscosity and lower cool viscosity of rice flour in amylogram. The sponginess of cooled cooked rice was closely associated with magnesium content and volume expansion of cooked rice. The hardness-changed ratio of cooked rice by cooling was negatively correlated with solids amount extracted during boiling and volume expansion of cooked rice. The major physicochemical properties of rice grain closely related to the palatability of cooked rice may be directly or indirectly associated with the retrogradation characteristics of cooked rice. The softer gel consistency and lower amylose content in milled rice revealed the higher ratio of popped rice and larger bulk density of popping. The stronger hardness of rice grain showed relatively higher ratio of popping and the more chalky or less translucent rice exhibited the lower ratio of intact popped brown rice. The potassium and magnesium contents of milled rice were negatively associated with gross score of noodle making mixed with wheat flour in half and the better rice for noodle making revealed relatively less amount of solid extraction during boiling. The more volume expansion of batters for making brown rice bread resulted the better loaf formation and more springiness in rice bread. The higher protein rices produced relatively the more moist white rice bread. The springiness of rice bread was also significantly correlated with high amylose content and hard gel consistency. The completely chalky and large gram rices showed better suitability for fermentation and brewing. Our breeding efforts on rice quality improvement for the future should focus on enhancement of palatability of cooked rice and marketing qualify as well as the diversification in morphological and physicochemical characteristics of rice grain for various value-added rice food processings.

  • PDF

Optical Property of Super-RENS Optical Recording Ge2Sb2Te5 Thin Films at High Temperature (초해상 광기록 Ge2Sb2Te5 박막의 고온광물성 연구)

  • Li, Xue-Zhe;Choi, Joong-Kyu;Lee, Jae-Heun;Byun, Young-Sup;Ryu, Jang-Wi;Kim, Sang-Youl;Kim, Soo-Kyung
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.5
    • /
    • pp.351-361
    • /
    • 2007
  • The samples composed of a GST thin film and the protective layers of $ZnS-SiO_2$ or $Al_2O_3$ coated on c-Si substrate were prepared by using the magnetron sputtering method. Samples of three different structures were prepared, that is, i) the GST single film on c-Si substrate, ii) the GST film sandwiched by the protective $ZnS-SiO_2$ layers on c-Si substrate, and iii) the GST film sandwiched by $Al_2O_3$ protective layers on c-Si substrate. The ellipsometric constants in the temperature range from room temperature to $700^{\circ}C$ were obtained by using the in-situ ellipsometer equipped with a conventional heating chamber. The measured ellipsometric constants show strong variations versus temperature. The variation of ellipsometric constants at the temperature region higher than $300^{\circ}C$ shows different behaviors as the ambient medium is changed from in air to in vacuum or the protective layers are changed from $ZnS-SiO_2$ to $Al_2O_3$. Since the long heating time of 1-2 hours is believed to be the origin of the high temperature variation of ellipsometric constants upon the heating environment and the protective layers, a PRAM (Phase-Change Random Access Memory) recorder is introduced to reduce the heating time drastically. By using the PRAM recorder, the GST samples are heated up to $700^{\circ}C$ decomposed preventing its partial evaporation or chemical reactions with adjacent protective layers. The surface image obtained by SEM and the surface micro-roughness verified by AFM also confirmed that samples prepared by the PRAM recorder have smoother surface than the samples prepared by using the conventional heater.

Comparison of Helical TomoTherapy with Linear Accelerator Base Intensity-modulated Radiotherapy for Head & Neck Cases (두경부암 환자에 대한 선량체적 히스토그램에 따른 토모치료외 선형가속기기반 세기변조방사선치료의 정량적 비교)

  • Kim, Dong-Wook;Yoon, Myong-Geun;Park, Sung-Yong;Lee, Se-Byeong;Shin, Dong-Ho;Lee, Doo-Hyeon;Kwak, Jung-Won;Park, So-Ah;Lim, Young-Kyung;Kim, Jin-Sung;Shin, Jung-Wook;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.89-94
    • /
    • 2008
  • TomoTherapy has a merit to treat cancer with Intensity modulated radiation and combines precise 3-D imaging from computerized tomography (CT scanning) with highly targeted radiation beams and rotating beamlets. In this paper, we comparing the dose distribution between TomoTherapy and linear accelerator based intensity modulated radiotherapy (IMRT) for 10 Head & Neck patients using TomoTherapy which is newly installed and operated at National Cancer Center since Sept. 2006. Furthermore, we estimate how the homogeneity and Normal Tissue Complication Probability (NTCP) are changed by motion of target. Inverse planning was carried out using CadPlan planning system (CadPlan R.6.4.7, Varian Medical System Inc. 3100 Hansen Way, Palo Alto, CA 94304-1129, USA). For each patient, an inverse IMRT plan was also made using TomoTherapy Hi-Art System (Hi-Art2_2_4 2.2.4.15, TomoTherapy Incorporated, 1240 Deming Way, Madson, WI 53717-1954, USA) and using the same targets and optimization goals. All TomoTherapy plans compared favorably with the IMRT plans regarding sparing of the organs at risk and keeping an equivalent target dose homogeneity. Our results suggest that TomoTherapy is able to reduce the normal tissue complication probability (NTCP) further, keeping a similar target dose homogeneity.

  • PDF

Measurements of Carotid Intima, Media, and Intima-media Thickness and Their Clinical Importance (경동맥의 내막, 중막, 내중막 두께 분리측정 및 임상적 중요성)

  • Kim Wuon-Shik;Jeong Hwan-Taek;No Ki-Yong;Bae Jang-Ho
    • Progress in Medical Physics
    • /
    • v.16 no.4
    • /
    • pp.207-213
    • /
    • 2005
  • The severity of carotid Intima-media thickness (IMT) is an Independent predictor of atherosclerosis which causes transient cerebral ischemia, stroke, and coronary events such as myocardial Infarction. The IMT consists of Intima thickness (IT) and media thickness (MT). However, the Individual clinical significance of IT and MT has not been well studied. We devised a method of measuring IT, MT, and IMT using B-mode ultrasound Image processing technique for the diagnosis of atherosclerosis. To inspect the clinical significance of IT, MT, and IMT, one hundred forty-four consecutive patients (mean age; 57 years old, 72 males) were underwent common carotid artery scanning using high-resolution ultrasound. Results showed that, the IT (p<0.05), MT (p<0.05) as well as IMT (p<0.01) of patients with atherosclerotic disease were significantly thicker than that of the patients without atherosclerotic disease. Patients with hyperiension showed significantly thicker IT (p<0.01), MT (p<0.001), and IMT (p<0.001). However, only IT was thicker in patients with smoking (p<0.01). The IT (r=0.374, p=0.001), MT (r=0.433, p=0.000), and IMT (r=0.479, p=0.000) showed positive correlation with age. The coefficients of determination ($r^2$) were estimated to be $92.4\%$ for IMT and MT, $49.1\%$ for IMT and IT, and $27.4\%$ for IT and MT. This result suggests that the Intima layer of the carotid artery has a different physiology with the media layer.

  • PDF

Intergrowth and Interlayering of Muscovite, Chlorite, and Biotite in a Garnet Zone Metamorphic Rock of the Ogcheon Belt, South Korea (옥천대의 석류석데 변성암에서 산출되는 백운모, 녹니석 및 흑운모의 Intergrowth와 Interlayering)

  • Yeong Boo Lee;Jung Hoo Lee;Chang Whan Oh
    • Journal of the Mineralogical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.122-131
    • /
    • 2002
  • Muscovite, chlorite and biotite in metapelites of the Ogcheon Hetamorphic Belt are studied using electron probe microanalysis (EPMA), backscattered electron images (BEI) of scanning electron microscopy (SEM) and lattice fringe images of transmission electron microscopy (TEM). These minerals are observed to be intergrown under a polarized light microscope and are apparently interlayered below EPMA resolution; EPMA data often indicate mixtures of phyllosilicates such as muscovite/chlorite (M/C), biotite/chlorite (B/C), muscovite/pyrophyllite/chlorite (M/P/C). biotite/pyrophyllite/chlorite (B/P/C) or biotite/muscovite/chlorite (B/M/C). BEI observations show that the three minerals (muscovite, chlorite and biotite) are mixed at various scales in a grain through the garnet zone, and the interlayering of the three minerals are observed from TEM lattice fringe images and selected area electron diffraction patterns. The result of TEM observations reveals that 7-$\AA$ layers (serpentine, precursor of chlorite) are interlayered within 10-$\AA$ layers (muscovite) at 100~200 $\AA$ scale as well as M/C in the chlorite zone. The 7-$\AA$ layers become smaller in size and less frequent in the biotite tone, and 10-$\AA$ layers are interlayered with chlorite (14 $\AA$) at an individual layer scale. The 7-$\AA$ layers are no longer observed in the garnet zone, and 10-$\AA$ layers (biotite) are interlayered with chlorite (B/C) at 50~100 $\AA$ scale. Relatively large scale (1000~2000 $\AA$) of intergrowth is also frequently observed from the garnet zone samples. However, rocks from all three metamorphic zones show interlayering of a few units of 7-, 10- and 14-$\AA$ layers with each other at TEM observations. The result of this study implies that metamorphic minerals such as muscovite, chlorite and biotite form through disequilibrum mineral reactions resulting in inhomogenious phases.

A QUALITATIVE AND QUANTITATIVE STUDY ON OCCLUSAL CONDITIONS IN HEALTH VOLUNTEERS AND ATHLETES WITH NORMAL OCCLUSION (정상인과 체육인의 교합상태에 대한 정상적.정량적 비교 연구)

  • Jang, Jung-Mi;Lee, Sung-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.302-322
    • /
    • 1998
  • This study was accompolished to analyze and compare the number and area of the occlusal contact points in healthy volunteers and athletes with normal occlusion. For this study, 15 athletes(13 amles and 2 females with average age 20) and 21 healthy volunteers(14 mles and 7 females with average age 20.09) were selected. The visual display acquired by scanning of occlusal record in maximal intercuspation was converted into 16 gray value image. Then, using computer program(J & Lee Occlusal Analyser), the pixel which was in definite range of the gray value was recognized, and the numbers of recognized pixel were calculated to area. The results were as follows ; 1. The average numbers of total occlusal contact feints were 31.05 in control group, and 34.67 in athlete group. The average area of total occlusal contacts was $100.25mm^2$ in control group, and $127.78mm^2$ in athlete group. 2. In control group, the average numbers of occlusal contact points were revealed in order as follows ; the first molar(8.48), the second molar(8.24), the second premolar(4.71), the lateral incisor(2.90), the first premor(2.43), the central incisor(2.19), and the canine(2.1). The least average in canine(2.1) was similar to the average(2.19) in central incisor and (2.09) in lateral incisor. In athlete group, the average numbers of occlusal contact points were revealed in order as follows ; the first molar(8.97), the second molar(8.47), the second premolar(5.60), the canine(3.80), the lateral incisor(3.33), the first premolar(2.67), and the central incisor(1.93). 3. In control group, the average areas of occlusal contact surface were revealed in order as follows ; the first molar($39.47mm^3$), the second molar($37.54mm^3$), the second premolar($9.54mm^3$) the first premolar($6.18mm^3$), canine($3.49mm^3$), the central incisor($2.76mm^3$), and the lateral incisor($1.28mm^3$). In athlete group, the average areas of occlusal contact surface were revealed in order as follows ; the first molar($44.11mm^3$), the second molar($40.69mm^3$), the second premolar($16.50mm^3$), the first premolar($9.39mm^3$), the canine($5.08mm^3$), the lateral incisor($3.7mm^3$), and the central incisor($2.25mm^3$). 4. With aging in both control and athlete group, there was a decreasing tendancy in average number of occlusal contact point, and was an increasing tendancy in average area of occlusal contact surface. In comparison at each age, both the numbers and area of occlusal contact were greater in athlete group than in control group. It was not significant in the numbers of occlusal contact points beween athlete and control group(p>0.1), but significant in the area of occlusal contact surface(p<0.03). 5. In comparision as to the kind of sports(Gymnastics : 2, Rugby : 3, Soccor : 5, Ice hocky : 5), the numbers of occlusal contact points were the most in ice hocky, and the area of occlusal contact surface was the greatest in gymnastics. With increasing a career in athlete group, there was a decreasing tendancy in average numbers of occlusal contact points and was an increasing tendancy in average area of occlusal contact surface. 6. By T-scan analyzing, the contact numbers on the anterior teeth were greater in control group than in athlete group, and on the posterior teeth were greater in athlete group than in control group. And the results acquired by T-scan were lesser than that caquired by the silicone bite records. It was not significant in the posterior teeth, but significant in the anterior teeth. In T-scan records, the numbers of occlusal contact points on second molar were the greatest, but in the silicone records, the numbers on first molar were the greatest.

  • PDF

Quantitative Evaluation of the Accuracy of 3D Imaging with Multi-Detector Computed Tomography Using Human Skull Phantom (두개골 팬텀을 이용한 다검출기 CT 3차원 영상에서의 거리측정을 통한 정량적 영상특성 평가)

  • 김동욱;정해조;김새롬;유영일;김기덕;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.131-140
    • /
    • 2003
  • As the importance of accuracy in measurings of 3-D anatomical structures continues to be stressed, an objective and quantitative of assessing image quality and accuracy of 3-D volume-rendered images is required. The purpose of this study was to evaluate the quantitative accuracy of 3-D rendered images obtained with MDCT, scanned at various scanning parameters (scan modes, slice thicknesses and reconstruction slice thickness). Twelve clinically significant points that play an important role for the craniofacial bone in plastic surgery and dentistry were marked on the surface of a dry human skull. The direct distances between the reference points were defined as gold standards to assess the measuring errors of 3-D images. Then, we scanned the specimen with acquisition parameters of 300 mA, In kVp, and 1.0 sec scan time in axial and helical scan modes (pitch 3:1 and 6:1) at 1,25 mm, 2.50 mm, 3.75 mm and 5.00 mm slice thicknesses. We performed 3-D visualizations and distance measurements with volumetric analysis software and statistically evaluated the quantitative accuracy of distance measurements. The accuracy of distance measurements on the 3-D images acquired with 1.25, 2.50, 3,75 and 5.00 mm slice thickness were 48%, 33%, 23%, 14%, respectively, and those of the reconstructed 1.25 mm were 53%, 41%, 43%, 36% respectively. Meanwhile, there were insignificant statistical differences (P-value<0.05) in the accuracy of the distance measurements of 3-D images reconstructed with 1.25 mm thickness. In conclusion, slice thickness, rather than scan mode, influenced the quantitative accuracy of distance measurements in 3-D rendered images with MDCT. The quantitative analysis of distance measurements may be a useful tool for evaluating the accuracy of 3-D rendered images used in diagnosis, surgical planning, and radiotherapeutic treatment.

  • PDF

Studies on changes in bulks of body per dose and in the positioning of duodenum by respiration when treating pancreatic cancer patients with radiation therapy (췌장암 환자의 방사선 치료 시 호흡에 따른 십이지장의 위치 변화 및 선량 당 체적 변화에 대한 연구)

  • Jang, Hyeong-Jun;Chun, Geum-Seong;Park, Yeong-Gyu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.51-57
    • /
    • 2014
  • Purpose : In the case of treating pancreatic cancer, the importance is put on the spread of dose. Changes take place in duodenum in accordance with respiration. Thus, in this paper, I am going to trace the positioning of duodenum and the changes in bulks of body per dose by scanning the patients' Kilovoltage Cone-Beam CT using the hospital equipped CT-on rail System. Materials and Methods : Seeing three patients, I have acquired KVCBCT by using CT-on rail System and spotted the change in positioning at duodenum after comparing with the preliminary image of treatment plan by using SYNGO Software. Then, I followed the change in the bulk of duodenum and analyzed the changes in bulks of body on the same dose by transmitting the acquired KVCBCT into Pinnacle, a treatment plan system. Results : The changes in the positioning shall be as set forth like this: 1.2cm, 1.0cm in Left-Right Direction, 0cm, 0.8cm in Craniocaudal Direction, 0.1cm, and 1.0cm in Anterior-Posterior Direction. Patient number one showed that his bulks in body had increased by maximum 460%, minimum 120%, the bulks in patient number two had increased bymaximum 490%, minimum 160%, and the bulks of patient number three had increased by maximum 150%. But Minimum volume decreased 30%. Patient number one showed only a little bit of change at first when compared with the preliminary treatment plan. However, the dose increased the bulks in the patient's body: $V_{10}$ 118%, $V_{20}$ 117%, $V_{30}$ 400%, and $V_{40}$ 480% Conclusion : In treating patients with radiation therapy using 3D-CRT, the dose amount penetrated into duodenum needs to be minimized by planning appropriate treatment beforehand. In order to establish an appropriate treatment plan it is required to comprehend the changes at positioning of the duodenum by respiration and predict the changes in the bulks of duodenum by setting precise Planning Target Volume.