• 제목/요약/키워드: Scanned data

검색결과 480건 처리시간 0.024초

대출업무 자동화를 위한 시스팀설계에 관한 연구 (System Analysis for the Automated Circulation)

  • 김광영
    • 한국비블리아학회지
    • /
    • 제4권1호
    • /
    • pp.85-102
    • /
    • 1980
  • Accepting the necessity for maintaining the objectives of the existing circulation system, the computer-based system could be designed by the system analyst and librarians to gain a variety of improvements in the maintenance, accessibility of circulation records and more meaningful statistical records. If the terminal can be operated on-line, then this circulation data is transmitted directly to the computer, where it may update to the circulation file immediately or alternatively be kept in direct access file for updating in batch mode. on-line system in the circulation operations is "data-collection system" and "Bar-coded label system" Bar-coded label system is simple, quick, and error-free input of data. Attached to CRT terminal is a "light pen" which is hand held and will read a bar-coded label as the pen is passed over the labels (one affixed to the book itself, other carried on the borrower cards). Instantaneously the data concerning transaction is stored in the central mini-computer. It is useful, economical for us to co-operate many libraries in Korea and design borrower's ID code, book no., classification code in the Bar-coded label system by the members of the computer center and the library staff at every stage. As for book loan, the borrowers ID code, book number and classification code are scanned by the bar-code scanner or light pen and the computer decides whether to loan and store the data. The visual display unit shows the present status of a borrowers borrowing and decides whether borrower can borrow.

  • PDF

알고리즘 분해를 이용한 2-D DCT (An efficient VLSI Implementation of the 2-D DCT with the Algorithm Decomposition)

  • 정재길
    • 자연과학논문집
    • /
    • 제7권
    • /
    • pp.27-35
    • /
    • 1995
  • 정지영상이나 동영상 코딩에 적용되는 2-D DCT의 효율적인 VLSI 구현을 위한 방법을 제시하였다. 2차원 상태공간식에 근거한 알고리즘 및 데이타 분할기법을 활용하여 다중프로세서 구조에서 문제가 되는 프로세서간의 통신량을 크게 감축시켰으며, 모든 통신을 국부적(local)이 되도록 하였다. 순차 주사 방식의 영상데이타를 입력할 수 있도록 설계하여 입력장치에 소요되는 하드웨어를 최소화하였으며, 계산의 순서를 조정함으로써 일반적인 행.열 분할 방법을 사용하는 2-D DCT에서 필요로 하는 Transposition RAM을 제거하였다. 제안된 VLSI 구조는 실시간 one-chip 2-D DCT 및 보다 큰 2-D DCT로 확장될 수 있다.

  • PDF

광중합용 DLP 프린터로 제작한 전악 인공치아의 UV-C 초음파 세척에 따른 체적 안정성 평가 (Evaluation of dimension stability according to UV-C ultrasonic cleaning of full arch artificial teeth made with DLP printer for photopolymerization)

  • 김동연;이광영
    • 대한치과기공학회지
    • /
    • 제43권3호
    • /
    • pp.84-92
    • /
    • 2021
  • Purpose: The purpose of this study was to compare the dimension safety evaluation between a general ultrasonic cleaner and an ultrasonic cleaner equipped with UV-C (ultraviolet-C). Methods: An edentulous model was prepared. A denture base and an occlusal rim were fabricated, and scanning was performed. After scanning, a denture base and full arch artificial teeth were designed. The full arch artificial teeth were printed using a three-dimensional printer (n=10). The residual resin was washed with alcohol and then scanned (reference data). The printed specimens were classified and cleaned using a general ultrasonic cleaner (GU group) and an ultrasonic cleaner equipped with UV-C (UC group). After each washing, a rescan was performed (scan data). Reference data and scan data were superimposed using overlapping software. Data were statistically analyzed using the Mann-Whitney test (α=0.05). Results: In the deviation values of full arch artificial teeth, the GU group showed a high deviation of 18.02 ㎛ and the UC group showed a low deviation of 15.02 ㎛. The two groups demonstrated a statistically significant difference (p<0.05). Conclusion: Full arch artificial teeth prepared using photopolymerized resin were deformed according to the temperature of water generated in the ultrasonic cleaner. It is judged that there is no deformation according to the UV-C ultrasonic cleaner.

건축물 실시간 원격 스캔을 위한 SLAM 시스템 개발 시 고려사항 (Considerations for Developing a SLAM System for Real-time Remote Scanning of Building Facilities)

  • 강태욱
    • 한국BIM학회 논문집
    • /
    • 제10권1호
    • /
    • pp.1-8
    • /
    • 2020
  • In managing building facilities, spatial information is the basic data for decision making. However, the method of acquiring spatial information is not easy. In many cases, the site and drawings are often different due to changes in facilities and time after construction. In this case, the site data should be scanned to obtain spatial information. The scan data actually contains spatial information, which is a great help in making space related decisions. However, to obtain scan data, an expensive LiDAR (Light Detection and Ranging) device must be purchased, and special software for processing data obtained from the device must be available.Recently, SLAM (Simultaneous localization and mapping), an advanced map generation technology, has been spreading in the field of robotics. Using SLAM, 3D spatial information can be obtained quickly in real time without a separate matching process. This study develops and tests whether SLAM technology can be used to obtain spatial information for facility management. This draws considerations for developing a SLAM device for real-time remote scanning for facility management. However, this study focuses on the system development method that acquires spatial information necessary for facility management through SLAM technology. To this end, we develop a prototype, analyze the pros and cons, and then suggest considerations for developing a SLAM system.

무치악 환자에서 구강 스캔과 지대주 중첩을 이용한 임플란트 보철수복 증례 (Implant prosthesis for fully edentulous patients using intra-oral scanning and abutment merging technique: A case report)

  • 황찬현;정승미;김용준;김경희;방정환;김대환;최병호
    • 대한치과보철학회지
    • /
    • 제55권1호
    • /
    • pp.61-70
    • /
    • 2017
  • 본 증례에서는 기존의 총의치 사용 환자에서 의치의 이장된 인상면을 스캔하고 이를 삼차원적으로 반전하여 잔존 치조제의 형태를 재현하고, 의치에 방사선 불투과성 마커를 부착한 상태로 스캔 및 CT 촬영을 진행하여 스캔 이미지와 CT 영상이 중첩된 데이터 상에서 임플란트 식립을 계획하였다. 수술 당일에는 치은 형태에 맞게 제작된 맞춤형 지대주와 임시 수복물을 장착하였다. 임플란트 고정체의 골유착이 완료된 이후 최종 보철물을 제작하는 과정에서는 임플란트 식립 전 미리 스캔하여 저장된 임플란트 지대주 이미지 파일과 구강 내 지대주 상태에서 채득된 구강 스캔 이미지를 중첩하였다. 중첩을 통해 얻어진 정확한 지대주 형태 상에서 최종 보철물을 제작함으로써 최종 보철물의 변연 적합도를 높이고 임상 과정을 간소화 할 수 있었다.

Radiopacity of contemporary luting cements using conventional and digital radiography

  • An, Seo-Young;An, Chang-Hyeon;Choi, Karp-Sik;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제48권2호
    • /
    • pp.97-101
    • /
    • 2018
  • Purpose: This study evaluated the radiopacity of contemporary luting cements using conventional and digital radiography. Materials and Methods: Disc specimens (N=24, n=6 per group, ø$7mm{\times}1mm$) were prepared using 4 resin-based luting cements (Duolink, Multilink N, Panavia F 2.0, and U-cem). The specimens were radiographed using films, a complementary metal oxide semiconductor (CMOS) sensor, and a photostimulable phosphor plate (PSP) with a 10-step aluminum step wedge (1 mm incremental steps) and a 1-mm-thick tooth cut. The settings were 70 kVp, 4 mA, and 30 cm, with an exposure time of 0.2 s for the films and 0.1 s for the CMOS sensor and PSP. The films were scanned using a scanner. The radiopacity of the luting cements and tooth was measured using a densitometer for the film and NIH ImageJ software for the images obtained from the CMOS sensor, PSP, and scanned films. The data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests. Results: Multilink (3.44-4.33) showed the highest radiopacity, followed by U-cem (1.81-2.88), Panavia F 2.0 (1.51-2.69), and Duolink (1.48-2.59). The $R^2$ values of the optical density of the aluminum step wedge were 0.9923 for the films, 0.9989 for the PSP, 0.9986 for the scanned films, and 0.9266 for the CMOS sensor in the linear regression models. Conclusion: The radiopacities of the luting materials were greater than those of aluminum or dentin at the same thickness. PSP is recommended as a detector for radiopacity measurements because of its accuracy and convenience.

Application of Side Scan Sonar to Disposed Material Analysis at the Bottom of Coastal Water and River

  • Lee, Joong-Woo;An, Do-Gyoung
    • 한국항해항만학회지
    • /
    • 제27권3호
    • /
    • pp.259-266
    • /
    • 2003
  • Due to the growth of population and industrial development at the coastal cities, there has been much increase in necessity to effective control of the wastes into the coastal water and river. The amount of disposal at those waters has been increased rapidly ana it is necessary for us to track of it in order to keep the waterway safe and the water clean. The investigation and research in terms of water quality in these regions have been conducted frequently but the systematic survey of the disposed wastes at the bottom was neglected and/or minor. In this study we surveyed the status of disposed waste distribution at the bottom of coastal water and river from the scanned images. The intensity of sound received by the side scan sonar tow fish from the sea floor provides information as to the general distribution and characteristics of the superficial wastes. The port and starboard side scanned images produced from two arrays of transducers borne on a tow fish connected by tow cable to a tug boat have the area with width of 22m~112m and band of 44m~224m. All data are displayed in real-time on a high-resolution color display ($1280{\times}1024$ pixels) together with position information by DGPS. From the field measurement and analysis of the recorded images, we could draw the location and distribution of bottom disposals. Furthermore, we could make a database system which might be useful for navigation and fundamental for planning the waste reception and process control system.

Real-time Image Scanning System for Detecting Tunnel Cracks Using Linescan Cameras

  • Jeong, Dong-Hyun;Kim, Young-Rin;Cho, I-Sac;Kim, Eun-Ju;Lee, Kang-Moon;Jin, Kwang-Won;Song, Chang-Geun
    • 한국멀티미디어학회논문지
    • /
    • 제10권6호
    • /
    • pp.726-736
    • /
    • 2007
  • In this paper, real-time image scanning system using linescan cameras is designed. The system is specially designed to diagnose and analyse the conditions of tunnels such as crack widths through the captured images. The system consists of two major parts, the image acquisition system and the image merging system. To save scanned image data into storage media in real-time, the image acquisition system has been designed with two different control and management modules. The control modules are in charge of controlling the hardware device and the management modules handle system resources so that the scanned images are safely saved to the magnetic storage devices. The system can be mounted to various kinds of vehicles. After taking images, the image merging system generates extended images by combining saved images. Several tests are conducted in laboratory as well as in the field. In the laboratory simulation, both systems are tested several times and upgraded. In the field-testing, the image acquisition system is mounted to a specially designed vehicle and images of the interior surface of the tunnel are captured. The system is successfully tested in a real tunnel with a vehicle at the speed of 20 km/h. The captured images of the tunnel condition including cracks are vivid enough for an expert to diagnose the state of the tunnel using images instead of seeing through his/her eyes.

  • PDF

인공고관절 전치환술에 있어서 비구 재건 술에 관한 3차원 유한요소해석 (3-D Finite Element Analysis of Acetabular Reconstruction of THR)

  • 류제청;문무성;김규석;유명철
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.34-38
    • /
    • 1995
  • Using a 3-D finite element method (FEM), the biomechanical characteristics of a threaded truncated acetabular component and a porous coated hemispherical acetabular component were studied. The Von-Mises stress/strain patterns in the acetabulum reconstructed with these two different types of cementless acetabular cups were investigated. The geometry and dimensions of human hemi-pelvis used in the present shape modeling for finite element analysis were scanned with a 3-D laser scanner(TDS-9000, Cyberware, USA). The scanned data was numerically handled with a shape modelling software 'Pro-Engineer'. Using 19836, 16853 tetrahedral elements, respectively, the stress and displacement field of the acetabulum reconstructed with the two different types of the acetabular components were computed. While the hemi-sphere component was found to show a relatively similar stress/strain patterns to those in the normal hip, the results with the threaded cup showed a considerably different patterns from those in the normal condition. Several regions in cancellous bone near the threads and the edge of the truncated cup was found to be overstressed, especially in the superior-lateral part of the acetabulum. It was postulated that the excessive reaming-out of subchondral bone layer when the truncated cup was used can cause the presence of these overstressed regions of cancellous bone. This theoretical prediction for the implanted acetabulum appeared to consistent with the pathological observation of proximal/medial migration of the threaded truncated acetabular prostheses in the previous publications.

  • PDF

Prediction of the Chemical Composition and Fermentation Parameters of Winter Rye Silages by Near Infrared Spectroscopy

  • Park, Hyung Soo;Lee, Sang Hoon;Choi, Ki Choon;Lim, Young Cheol;Kim, Ji Hea;Lee, Ki Won;Choi, Gi Jun
    • 한국초지조사료학회지
    • /
    • 제34권3호
    • /
    • pp.209-213
    • /
    • 2014
  • This study was carried out to explore the accuracy of near infrared spectroscopy (NIRS) for the prediction of chemical and fermentation parameters of whole crop winter rye silages. A representative population of 216 fresh winter rye silages was used as database for studying the possibilities of NIRS to predict chemical composition and fermentation parameters. Samples of silage were scanned at 1 nm intervals over the wavelength range 680~2,500 nm and the optical data recorded as log 1/Reflectance (log 1/R) and scanned in fresh condition. NIRS calibrations were developed by means of partial least-squares (PLS) regression. NIRS analysis of fresh winter rye silages provided accurate predictions of moisture, acid detergent fiber (ADF), neutral detergent fiber (NDF), crude protein (CP) and pH as well as lactic acid content with correlation coefficients of cross-validation ($R^2cv$) of 0.96, 0.86, 0.79, 0.85, 0.82 and 0.78 respectively and standard error of cross-validation (SECV) of 1.89, 2.02, 2.79, 1.14, 1.47 and 0.46 % DM respectively. Results of this experiment showed the possibility of NIRS method to predict the chemical parameters of winter rye silages as routine analysis method in feeding value evaluation and for farmer advice.