• 제목/요약/키워드: Scanned data

검색결과 479건 처리시간 0.03초

3차원 인체스캐너를 이용한 거들 착용에 따른 인체 형상 단면도와 실루엣 변화 분석 (Analysis of cross sections and silhouette in body shape according to girdle worn using 3D body scanner)

  • 임호선;천종숙
    • 복식문화연구
    • /
    • 제23권2호
    • /
    • pp.242-253
    • /
    • 2015
  • The aim of this study was to use a 3D human body scanner to analyze the cross section of different body parts when a girdle is worn. Two types of girdles were selected as experimental garments: a standard type girdle (Garment A) and a high-waist type girdle (Garment B). Their sizes were 88 (S) and 94 (M). Ten female subjects in their twenties who wear girdles sizes 88 (S) and 94 (M) participated the experiment. Their bodies were scanned three times with the 3D human body scanner, before and after wearing experimental girdles. The data were collected by overlapping the cross sections of the 3D scanned body shape data. The space length was measured from the overlapped cross sections. The results show that human body silhouette are changed after wearing the compression type garments and the amount and place of the body change is different by style of garments. First, the waist girth shape became rounder. Second, there was a definite difference in space amount at abdomen girth between two types of girdle. The abdomen area was pushed toward the front after wearing the standard type girdle (A). The high-waist type girdle (B) pushed abdomen area toward the back. Third, there was clear difference at the hip area after wearing two types of girdle. The hip area pushed toward the front with the standard type girdle (A) and pushed toward the back with the high-waist type girdle (B).

Surface flatness and distortion inspection of precast concrete elements using laser scanning technology

  • Wang, Qian;Kim, Min-Koo;Sohn, Hoon;Cheng, Jack C.P.
    • Smart Structures and Systems
    • /
    • 제18권3호
    • /
    • pp.601-623
    • /
    • 2016
  • Precast concrete elements are widely used in the construction of buildings and civil infrastructures as they provide higher construction quality and requires less construction time. However, any abnormalities in precast concrete surfaces such as non-flatness or distortion, can influence the erection of the elements as well as the functional performance of the connections between elements. Thus, it is important to undertake surface flatness and distortion inspection (SFDI) on precast concrete elements before their delivery to the construction sites. The traditional methods of SFDI which are conducted manually or by contact-type devices are, however, time-consuming, labor-intensive and error-prone. To tackle these problems, this study proposes techniques for SFDI of precast concrete elements using laser scanning technology. The proposed techniques estimate the $F_F$ number to evaluate the surface flatness, and estimate three different measurements, warping, bowing, and differential elevation between adjacent elements, to evaluate the surface distortion. The proposed techniques were validated by experiments on four small scale test specimens manufactured by a 3D printer. The measured surface flatness and distortion from the laser scanned data were compared to the actual ones, which were obtained from the designed surface geometries of the specimens. The validation experiments show that the proposed techniques can evaluate the surface flatness and distortion effectively and accurately. Furthermore, scanning experiments on two actual precast concrete bridge deck panels were conducted and the proposed techniques were successfully applied to the scanned data of the panels.

Comparing volumetric and biological aspects of 3D-printed interim restorations under various post-curing modes

  • Song, Gun;Son, Ji-Won;Jang, Ji-Hyun;Choi, Sung-Hyeon;Jang, Woo-Hyung;Lee, Bin-Na;Park, Chan
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권2호
    • /
    • pp.71-78
    • /
    • 2021
  • Purpose. This study aims to compare the volumetric change, degree of conversion (DOC), and cytotoxicity of 3D-printed restorations post-cured under three different conditions. Materials and Methods. 3D-printed interim restorations were post-cured under three different conditions and systems: 5 min, 30 min, and 24 h. Three-unit and six-unit fixed dental prostheses (n = 30 for each case) were printed; ten specimens from each group were post-cured and then scanned to compare their volumetric changes. Root-mean-squared (RMS) values of the data were acquired by superimposing the scanned files with original files. Thirty disk-shaped specimens were printed to evaluate the DOC ratio. Fourier transform infrared spectroscopy was used to compare the DOCs of 10 specimens from each group. Human gingival fibroblasts were used to measure the cell viability of every specimen (n = 7). The data from this experiment were employed for one-way analysis of variance and Tukey's post-hoc comparisons. Results. Differences between the three-unit restorations were statistically insignificant, regardless of the post-curing conditions. However, for the six-unit restorations, a high RMS value was acquired when the post-curing duration was 30 min. The average DOC was approximately 56 - 62%; the difference between each group was statistically insignificant. All the groups exhibited cell viability greater than 70%, rendering them clinically acceptable. Conclusion. The post-curing conditions influenced the volume when the length of the restoration was increased. However, this deviation was found to be clinically acceptable. Additionally, post-curing did not significantly influence the DOC and cytotoxicity of the restorations.

In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies

  • Ozal, Cise;Ulusoy, Mutahhar
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권6호
    • /
    • pp.373-384
    • /
    • 2021
  • PURPOSE. This study aimed to compare the marginal and internal fit of 3-unit monolithic zirconia restorations that were designed by using the data obtained with the aid of intraoral and laboratory scanners. MATERIALS AND METHODS. For the fabrication of 3-unit monolithic zirconia restorations using impressions taken from the maxillary master cast, plaster cast was created and scanned in laboratory scanners (InEos X5 and D900L). The main cast was also scanned with different intraoral scanners (Omnicam [OMNI], Primescan [PS], Trios 3 [T3], Trios 4 [T4]) (n = 12 per group). Zirconia fixed partial dentures were virtually designed, produced from presintered block, and subsequently sintered. Marginal and internal discrepancy values (in ㎛) were measured by using silicone replica method under stereomicroscope. Data were statistically analyzed by using 1-way ANOVA and Kruskal Wallis tests (P<.05). RESULTS. In terms of marginal adaptation, the measurements on the canine tooth indicated better performance with intraoral scanners than those in laboratory scanners, but there was no difference among intraoral scanners (P<.05). In the premolar tooth, PS had the lowest marginal (86.9 ± 19.2 ㎛) and axial (92.4 ± 14.8 ㎛), and T4 had the lowest axio-occlusal (89.4 ± 15.6 ㎛) and occlusal (89.1 ± 13.9 ㎛) discrepancy value. In both canine and premolar teeth, the D900L was found to be the most marginally and internally inconsistent scanner. CONCLUSION. Within the limits of the study, marginal and internal discrepancy values were generally lower in intraoral scanners than in laboratory scanners. Marginal discrepancy values of scanners were clinically acceptable (< 120 ㎛), except D900L.

ETRI-모아레 스캐너를 이용한 3차원 모델의 자동생성 (Automatic Generation of 3D Models using ETRI- Moire Scanner)

  • 권대현;최이배;이의택
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 1999년도 학술대회
    • /
    • pp.47-52
    • /
    • 1999
  • 복잡한 모델이나 사실적인 모델을 짧은시간에 생성하기 위해서 기존 자유곡면(NURBS)이나 다각형(Polygon) 모델러를 사용하여 제작하는데 한계가 있다. 또한, 최근디지털 컨텐츠 산업의 급격한 발전과 컴퓨터 그래픽스 기술의 발전과 함께 삼차원 스캐너를 이용한 모델생성이 중요한 연구분야로 자리잡고 있다. 이 논문에서는 국내 최초로 한국 전자통신연구원이 개발에 성공한 모아레 방식의 삼차원 스캐너 시스템(RTRI Moire Scanner)의 삼차원 입체정보 처리 소프트웨어인Moireware의 설계 및 구현에 대해 설명하려고 한다. 본 시스템은 스캐너에서 얻어진다면 데이터 및 텍스췌 정보의 효율적인 정합, 가공, 편집 및 다양한 3차원 그래픽 파일 포맷을 제공한다.

  • PDF

SGML을 활용한 PDM에서의 설계변경문서관리 (The Engineering Change Document Management using SGML in PDM)

  • 김준오;김선호
    • 산업공학
    • /
    • 제10권2호
    • /
    • pp.79-90
    • /
    • 1997
  • Documents in a traditional PDM(Product Data Management) system have been managed in a form of scanned document files or electronic documents developed by specific tools. Though each tool manages documents with its own systematical methods, it has drawbacks in data search, data integration and interchange, etc. For this reason, in this research we propose an efficient document management system for PDM by using the SGML(Standard Generalized Markup Language), one of CALS and ISO standards for document interchanges. Among documents to be managed in PDM, the engineering change notification (ECN) is taken into account. The DTD (Document Type Definition) has been constucted based on the logical analysis of the documents format, In addition, based on the DTD, DB classes have been designed by object-oriented paradigms and a prototype for document input/output and search has been developed using UniSQL ORDBMS (Object-Relational DBMS) and PowerBuilder under the client/server environment.

  • PDF

A System for Rapid Design and Manufacturing of Custom-Tailored Shoes

  • Park, Sang-Kun;Lee, Kun-Woo;Kim, Jong-Won;Park, Jong-Woo
    • Journal of Mechanical Science and Technology
    • /
    • 제14권6호
    • /
    • pp.675-689
    • /
    • 2000
  • Rapid design and production techniques are indispensable for the custom-made production systems. For manufacturing custom-made shoes, the shoelast should be designed rapidly from the individual foot model. In this paper, we develop an integrated system for rapid design and manufacturing of custom-tailored shoes. The foot shape measurement sub-system allows scanning a standard shoelast and an individual foot and then extracts the three-dimensional crosssectional data of the shoelast and the human foot shape from the captured image data. The shoelast design sub-system uses the scanned data to design new customized shoelast curves or surfaces with the heeling and mixing algorithms built in this system. The pattern design subsystem provides a method, which transforms a shoe-upper surface designed by a stylist into a flat-pattern that can be manufactured. We also export the surface model to an NC machine to manufacture the physical shoelast model.

  • PDF

원격측정 토양수분자료, (C-band 측정치 vs. L-band 측정치)의 공간변화도 비교 (Comparison of the Spatial Variability of C- and L-Band Remotely Sensed Soil Moisture)

  • 김광섭;임태경
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2004년도 학술발표회
    • /
    • pp.705-708
    • /
    • 2004
  • The spatial variability of the L- and C- band large scale remotely sensed soil moisture data, obtained during tire Southern Great Plain 1999 (SGP'99), was characterized. The results demonstrate that soil moisture data using L-band show the break in statistical symmetry (multiscaling behavior) with the variation of scale of observation, which is similar to that of the soil property such as sand content. Also, soil moisture data using C-band show single scaling behavior with the variation of scale of observation, which Is similar to that of the vegetation condition.

  • PDF

평면 구조 진동 측정을 위한 자동화된 스캐닝 레이저 도플러 진동측정기의 개발 및 연구 (Development of An Automated Scanning Laser Doppler Vibrometer For Measurements of In-Plane Structural Vibration)

  • 길현권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1996년도 추계학술대회논문집; 한국과학기술회관, 8 Nov. 1996
    • /
    • pp.422-430
    • /
    • 1996
  • The automated scanning laser Doppler vibrometer (LDV) has been designed, and built to measure in-plane displacements associated with waves propagating on vibrating structures. Use of optical fibers allows the compact design of a laser probe head which can be scanned over the vibrating structures. An algorithm for automated self-alignment of the laser probe is developed. The system is completely automated for scanning over the structures, focusing two laser beams at each data point until the detected vibration signal is stable, and for recording and transferring the data to a system computer. The automated system allows one to get extensive data of the vibration field over the structures. The system is tested by scanning a piezoelectric cylindrical shell and a plate excited by a continuous signal and by a pulse signal, respectively. Results show that the automated scanning LDV system can be a useful tool to measure the in-plane vibration field and to detect the elastic waves propagating on the vibrating structures.

  • PDF

로봇을 이용한 치과 보철용 아치와이어 제작을 위한 굽힘각 계산 방법 (A Method to Compute Bending Angle for Robotic Shaping of Orthodontic Archwire)

  • 정성엽;송일재;황면중
    • 융복합기술연구소 논문집
    • /
    • 제7권2호
    • /
    • pp.17-20
    • /
    • 2017
  • Orthodontic treatment is accomplished by attaching an archwire to a bracket on tooth. The shape of the archwire is usually planned from 3-D scanned data of patient's teeth. It is manufactured by bending a metal wire and there have been some researches in progress to automate it. In this paper, we propose a method to obtain the bending angle at the bending point from the shape data of the archwire and verify it by simulation using actual archwire data.