• Title/Summary/Keyword: Scannable stone

Search Result 8, Processing Time 0.025 seconds

Comparative Study of the Surface Roughness of Working Models Fabricated by Dental CAD/CAM Scannable Stone and Type IV Gypsum Products (치과용 캐드캠 스캔전용 석고와 Type IV 석고로 제작된 작업모형의 표면조도 비교 연구)

  • Kim, Sa-Hak;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.14 no.4
    • /
    • pp.455-460
    • /
    • 2014
  • This study compared the surface roughness and surface characteristics between a type IV stone and scannable stone. Materials used were a type IV stone, two different kind of scannable stone. Ten specimens per experimental group were prepared according to manufacturer's direction. Surface roughness of specimen was measured using profilometer. The measurement was based on the standard of Japanese Industrial Standards 1994. The mean and standard deviations of each reference point were analyzed using one-way ANOVA and Scheff$\acute{e}$ post hoc test. The program used to handle statistical analysis was SPSS 20.0 and the significance level was set at 0.05. The difference of surface roughness was statistically significant in order of Scannable Stone $10.07{\pm}0.02{\mu}m$, Scannable Stone $20.08{\pm}0.03{\mu}m$, Type IV $0.10{\pm}0.04{\mu}m$. These results will have to be confirmed in further clinical application researches.

An evaluation of validity of three dimensional digital model fabricated by dental scannable stone (치과용 스캐너 전용 석고를 이용하여 제작된 3차원 디지털 모형의 정확도 평가)

  • Kim, Ki-Baek;Kim, Su-Jin;Kim, Jae-Hong;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.35 no.1
    • /
    • pp.29-35
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the validity of digital models fabricated by dental scannable stone. Methods: Twenty same cases of stone models(maxillary full arch) were manufactured. Intercanine distance, intermolar distance, two dental arch lengths(right, left), two diagonal of dental arch lengths(right, left) were measured for comparison. Each of ten stone models were measured by digital vernier calipers and scanned by dental scanner. Ten digital models were measured by CAD program. The mean(SDs) values were compared by a Mann-Whitney U test(${\alpha}$=0.05). Results: No statistically significant differences between the two groups were found at intermolar distance, dental arch length(right)(p>0.05). However, intercanine distance, dental arch length(left) and two diagonal of dental arch lengths(right, left) were statistically significant(p<0.05). Conclusion: Stone models fabricated by dental scannable stone showed larger than digital models.

Three-dimensional evaluation of stone models made of various gypsum products (다양한 석고제품으로 제작한 석고 모형의 정확성의 평가: 3차원 이미지의 컴퓨터 지원 분석)

  • Kim, Wook Tae
    • Journal of Technologic Dentistry
    • /
    • v.42 no.4
    • /
    • pp.321-325
    • /
    • 2020
  • Purpose: This study is to evaluate the accuracy of gypsum replica models made from various gypsum products. Methods: One main model was made of stainless steel by CNC milling process. Molds were formed from the main model, and the gypsum replica models were made using 8 types of type IV gypsum, 10 pieces each. The main model was digitized by a contact scanner (Incise; Renishaw) and the gypsum replicas were digitized by an optical scanner (E4; 3Shape A/S). The difference between the main model and the gypsum replicas were measured by inspection software (3D Systems). One-way ANOVA was performed to evaluate the statistical significance of differences between groups. In addition, the independent sample T test was performed to determine the difference between the conventional and scannable stone group (n=10, α=0.05). Results: The root mean square of the stone models were 7.24 ㎛ to 10.78 ㎛, and statistical significance was found between the two groups (SR, FR) and the other 6 groups (IS, SG, CA, CS, ER, EBG) (p<0.05). The accuracy of the gypsum replicas was 9.04 ㎛ and 7.62 ㎛ in the conventional and scannable stone group, respectively. There was statistical significance between the two groups (p<0.01). Conclusion: In the limited results of this study, the product with low setting expansion and the scannable showed high accuracy. Therefore, in order to obtain a stable and accurate scan model, it is more effective in terms of accuracy to use a scannable stone with a low setting expansion.

The Influence of Different Gypsum Materials on the Accuracy from Complete Arch Digital Impression (전악의 디지털 인상 채득 시 치과용 모형재가 디지털 모형 정확성에 미치는 영향)

  • Kim, Ki-Baek;Lee, Gyeong-Tak;Kim, Hae-Young;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.12 no.6
    • /
    • pp.617-623
    • /
    • 2012
  • This study was performed to measure the accuracy of different gypsum materials by a white light dental scanner. A master model with the prepared lower full arch tooth was used. The type IV and scannable stone were used for 20 stone casts (10 casts each) duplicated a master model of mandible. The distance between the reference points were measured and analyzed by the Delcam $Copycad^{(R)}$ (Delcam Plc, UK) 3D graphic software. The t-student test for paired samples were used for statistical analysis. The mean differences to master model for type IV stone and scannable stone model were 0.29~0.56 mm, and 0.17~0.35 mm, respectively. There were statistical differences in dimensional accuracy for full arch impression between the master model and type IV/scannable stone (p<0.05). Two different gypsum materials showed clinically acceptable accuracies of full arch digital impression produced by them. Besides, in both gypsum materials, the differences to the master model detected appear to provide enough accuracy for clinical application.

Impact of surface roughness of gypsum materials on adaptation of zirconia cores

  • Kim, Ki-Baek;Kim, Jae-Hong;Kim, Sa-Hak
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.199-206
    • /
    • 2015
  • PURPOSE. The present study investigated the influences of various gypsum materials on the precision of fit of CAD/CAM-fabricated prostheses and analyzed their correlation with surface roughness. MATERIALS AND METHODS. The master model of the mandibular right first molar was replicated, and four experimental groups based on two types of Type IV stone (GC Fujirock EP, Die keen) and two types of scannable stone (Aesthetic-Basegold, Everest Rock) were created to include a total of 40 specimens, 10 in each group. The surface roughness of the working models for the respective experimental groups was measured. Once the zirconia cores had been fabricated, the marginal and internal fits were measured with a digital microscope using the silicone replica technique. The mean and standard deviation of the respective points of measurement were computed and analyzed through the one-way ANOVA and Tukey's HSD test. The correlation between surface roughness and the precision of fit of the zirconia core was analyzed using the Pearson correlation analysis (${\alpha}$=.05). RESULTS. The zirconia cores fabricated from the scannable stone working models exhibited a superior precision of fit as compared to those fabricated from the Type IV stone working models. The correlation analysis results showed a clear positive correlation between surface roughness and the precision of fit of zirconia cores in all of the experimental groups (P<.05). CONCLUSION. The results confirmed that the surface roughness of dental working models has a decisive influence on the precision of fit of zirconia cores.

Evaluation of marginal and internal gap of three-unit metal framework according to subtractive manufacturing and additive manufacturing of CAD/CAM systems

  • Kim, Dong-Yeon;Kim, Eo-Bin;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.6
    • /
    • pp.463-469
    • /
    • 2017
  • PURPOSE. To evaluate the fit of a three-unit metal framework of fixed dental prostheses made by subtractive and additive manufacturing. MATERIALS AND METHODS. One master model of metal was fabricated. Twenty silicone impressions were made on the master die, working die of 10 poured with Type 4 stone, and working die of 10 made of scannable stone. Ten three-unit wax frameworks were fabricated by wax-up from Type IV working die. Stereolithography files of 10 three-unit frameworks were obtained using a model scanner and three-dimensional design software on a scannable working die. The three-unit wax framework was fabricated using subtractive manufacturing (SM) by applying the prepared stereolithography file, and the resin framework was fabricated by additive manufacturing (AM); both used metal alloy castings for metal frameworks. Marginal and internal gap were measured using silicone replica technique and digital microscope. Measurement data were analyzed by Kruskal-Wallis H test and Mann-Whitney U-test (${\alpha}=.05$). RESULTS. The lowest and highest gaps between premolar and molar margins were in the SM group and the AM group, respectively. There was a statistically significant difference in the marginal gap among the 3 groups (P<.001). In the marginal area where pontic was present, the largest gap was $149.39{\pm}42.30{\mu}m$ in the AM group, and the lowest gap was $24.40{\pm}11.92{\mu}m$ in the SM group. CONCLUSION. Three-unit metal frameworks made by subtractive manufacturing are clinically applicable. However, additive manufacturing requires more research to be applied clinically.

Analysis of quality for fixed prostheses fabricated by dental CAD-CAM system (치과용 캐드캠 시스템으로 제작된 고정성 보철물의 품질 분석)

  • Kim, Won-Soo;Han, Man-So;Jung, Jae-Kwan;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.36 no.3
    • /
    • pp.159-164
    • /
    • 2014
  • Purpose: The purpose of this study was analysis of quality of fixed prostheses fabricated by dental CAD/CAM system. Methods: The ten same cases of stone models were manufactured by dental scannable model, and stone models were scanned using the dental scanner for changing digital model. Ten digital models were completed. The design of zirconia core for zirconia based all-ceramic crown was conducted by the dental CAD program. The samples were fabricated using the pre-sintered zirconia block by dental milling machine. Marginal gaps were analyzed using by silicone replica technique at the eight parts for quality analysis of samples. One-way ANOVA was used for statistical analysis(${\alpha}=0.05$). Results: The mean for marginal gaps were $93.2{\sim}99.1{\mu}m$ at the eight parts. One-was ANOVA didn't show significant differences(p=0.089). Conclusion: The fixed dental prostheses fabricated by dental CAD/CAM were within clinically acceptable range.

Evaluation of the Model Accuracy according to Three Types of Dental Scanner (세 가지 방식의 스캐너 종류에 따른 모형 정확도 평가)

  • Lee, Jae-Jun;Park, Jin-Young;Bae, So-Yeon;Jeon, Jin-Hun;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of dental hygiene science
    • /
    • v.15 no.2
    • /
    • pp.226-231
    • /
    • 2015
  • The purpose of this study was to evaluate the accuracy of model according to three types of dental scanner. A maxillary acrylic model was prepared and duplicated 10 times by silicone impression materials. Corresponding working casts were formed from scannable stone and got a 3-dimensional digital models using three different scanners. The distance of each measurement region was measured using vernier calipers and the respective program. One-way ANOVA and the Tukey honestly significant difference post hoc test (${\alpha}=0.05$) was performed using IBM SPSS Statistics 21.0. Overall, the stone cast is smaller than the digital models in measurement distance. And measuring point value of laser scanner showed the most similar values and measurement points value of digital vernier calipers. Digital model of white light scanner showed similar values in the measurement points value of the blue light scanner. In conclusion, the laser scanner showed the best accuracy among the three types of dental scanner. However, the difference between the digital models and the stone cast can be accommodated in making prostheses. Thereby, three types of dental scanner are available in a clinically acceptable range.