• 제목/요약/키워드: Scan technique

검색결과 594건 처리시간 0.028초

영상처리기법을 이용한 그린시트 측정알고리즘 개발 (Development of Green-Sheet Measurement Algorithm by Image Processing Technique)

  • 표창률;양상모;강성훈;윤성만
    • 소성∙가공
    • /
    • 제16권4호
    • /
    • pp.313-316
    • /
    • 2007
  • The purpose of this paper is the development of measurement algorithm for green-sheet based on the digital image processing technique. The Low Temperature Co-fired Ceramic(LTCC) technology can be employed to produce multilayer circuits with the help of single tapes, which are used to apply conductive, dielectric and/or resistive pastes on. These single green-sheets must be laminated together and fired at the same time. Main function of the green-sheet film measurement algorithm is to measure the position and size of the punching hole in each single layer. The line scan camera coupled with motorized X-Y stage is used. In order to measure the entire film area using several scanning steps, an overlapping method is used.

3 Tesla MRI 시스템에서 초고속 나선주사영상을 위한 고차 shimming (Higher Order Shimming for Ultra-fast Spiral-Scan Imaging at 3 Tesla MRI System)

  • 김판기;임종우;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • 제11권2호
    • /
    • pp.95-102
    • /
    • 2007
  • 목적: 3.0 Tesla와 같은 고 자장에서 고해상도의 나선주사영상을 얻기 위해서는 주자장을 균일하게 만들어야 한다. 특히, 나선주사영상인 경우 스핀-에코펄스 시퀀스(SE)나 경사자계 에코 펄스 시퀀스(GE)에 비하여 측정 시간이 길기 때문에 주자장이 균일하지 못하다면, off-resonance 현상으로 영상의 blur가 심해진다. 본 연구에서는 빠른 시간 안에 주자장을 균일하게 할 수 있는 고차(Higher-order) shimming방법을 모색했다. 대상 및 방법: 3 Tesla 자기 공명 영상시스템에서 고해상도의 나선주사영상을 얻기에 적합할 정도의 균일한 주자장을 빠른 시간 안에 만들기 위해, 한번의 스캔으로 axial, sagittal, coronal 방향의 불균일도 map을 구할 수 있는 펄스 시퀀스를 제안하였고, 불균일도 map으로부터 spherical harmonics 분석를 통해 shim 코일에 적절한 전류를 인가하여 주자장을 균일하게 만들었다. 결과: 3 Tesla 자기 공명 영상 시스템에서 주자장의 불균일도는 주자장의 크기에 비례하게 된다. 제안한 펄스 시퀀스로 얻은 영상을 이용하여 불균일도 Map을 만들 수 있었고, 이를 spherical harmonics 분석을 하여 2-3회의 고차 shimming으로 불균일한 자장을 균일하게 만들 수 있었다. 제안된 고차 shimming 방법은 전체 영상 영역 뿐만 아니라 선택한 영역에 대해서만 적용도 가능하기 때문에 국부 영역에 대한 고차 shimming이 가능하다. 고차 shimming이 적용되어 주자장이 균일하게 개선된 상태에서 고해상도의 나선주사영상을 얻을 수 있었다. 결론: 3 Tesla 고자장 자기 공명 영상 시스템에서 주자장의 불균일도를 개선하기 위한 펄스 시퀀스와 알고리즘을 통해 주자장의 불균일도를 빠른 시간 안에 개선할 수 있었다. 주자장의 불균일도를 효과적으로 개선함으로써, 고해상도의 나선주사 영상을 얻을 수 있었다.

  • PDF

컴퓨터제어에 의한 자동초음파 탐상장치에 관한 연구 (A study on Computer-controlled Ultrasonic Scanning Device)

  • 허형;박치승;홍순신;박종현
    • 비파괴검사학회지
    • /
    • 제9권1호
    • /
    • pp.30-38
    • /
    • 1989
  • Since the nuclear power plants in Korea have been operated in 1979, the nondestructive testing (NDT) of pressure vessels and/or piping welds plays an important role for maintaining the safety and integrity of the plants. Ultrasonic method is superior to the other NDT method in the viewpoint of the detectability of small flaw and accuracy to determine the locations, sizes, orientations, and shapes. As the service time of the nuclear power plants is increased, the radiation level from the components is getting higher. In order to get more quantitative and reliable results and secure the inspector from the exposure to high radiation level, automation of the ultrasonic equipments has been one of the important research and development(R & D) subject. In this research, it was attempted to visualize the shape of flaws presented inside the specimen using a Modified C-Scan technique. In order to develope Modified C-Scan technique, an automatic ultrasonic scanner and a module to control the scanner were designed and fabricated. IBM-PC/XT was interfaced to the module to control the scanner. Analog signals from the SONIC MARK II were digitized by Analog-Digital Converter(ADC 0800) for Modified C-Scan display. A computer program has been developed and has capability of automatic data acquisition and processing from the digital data, which consist of maximum amplitudes in each gate range and locations. The data from Modified C-Scan results was compared with shape from artificial defects using the developed system. Focal length of focused transducer was measured. The automatic ultrasonic equipment developed through this study is essential for more accurate, reliable, and repeatable ultrasonic experiments. If the scanner are modified to meet to appropriate purposes, it can be applied to automation of ultrasonic examination of nuclear power plants and helpful to the research on ultrasonic characterization of the materials.

  • PDF

결정론적 테스트 세트의 신호확률에 기반을 둔 clustered reconfigurable interconnection network 내장된 자체 테스트 기법 (A Clustered Reconfigurable Interconnection Network BIST Based on Signal Probabilities of Deterministic Test Sets)

  • 송동섭;강성호
    • 대한전자공학회논문지SD
    • /
    • 제42권12호
    • /
    • pp.79-90
    • /
    • 2005
  • 본 논문에서는 의사무작위패턴만으로는 생산하기 힘든 결정론적 테스트 큐브의 생산확률을 높일 수 있는 새로운 clustered reconfigurable interconnect network (CRIN) 내장된 자체 테스트 기법을 제안한다. 제안된 방법은 주어진 테스트 큐브들의 신호확률에 기반을 둔 스캔 셀 재배치 기술과 규정 비트(care-bit: 0 또는 1)가 집중된 스캔 체인 테스트 큐브의 생산확률을 높이기 위한 전용의 하드웨어 블록을 사용한다. 테스트 큐브의 생산확률을 최대로 할 수 있는 시뮬레이티드 어닐링(simulated annealing) 기반 알고리듬이 스캔 셀 재배치를 위해 개발되었으며, CRIN 하드웨어 합성을 위한 반복 알고리듬 또한 개발되었다. 실험을 통하여 제안된 CRIN 내장된 자체 테스트 기법은 기존의 연구 결과보다 훨씬 적은 저장 공간과 짧은 테스트 시간으로 $100\%$의 고장검출율을 달성할 수 있음을 증명한다.

다구찌 방법을 이용한 레이저 포토리소그라피 미세패턴가공 기술의 최적화 (Optimization of Laser Photolithography Micromachining Technique based on Taguchi Method)

  • 백남국;김대은
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.871-875
    • /
    • 2001
  • Laser photolithography technique is useful for fabricating micro-patterns of silicon wafers. In this work, the laser photolithography micromachining technique is optimized based on Taguchi method. Sensitivity analysis was performed using laser scanning speed and laser power level as the parameters. The results show that for the photoresist used in this work, a laser scan speed of $70{\mu}m/s$ at 50mW laser power gives the best result.

  • PDF

초음파 현미경 시스템에 의한 B-스캔 영상처리 기술 (B-Scan Image Processing Technique by Using Ultrasonic Microscope System)

  • 고대식;전계석
    • 대한전자공학회논문지
    • /
    • 제27권12호
    • /
    • pp.1889-1893
    • /
    • 1990
  • In this paper, ultrasonic microscope system has been constructed with the small aperturre acoustic lens and the angle controller, and the new type of B-scanultransonic imaging has been analyzed. The system with small aperture lens was used to detect flaw existing within the thick specimen and its resolution was in the range of one wavelength at interior plane of sample. The anle controller was used to excited surface acoustic wave or shear wave. In order to obtain B-scan image of the flaw existig at interior of solids, shear wave has been excited and backscattering signals from the flaw have been processed. In experimental results, B-scan ultransonic images have been obtain from the flaws of varable shape and measured flaw size from the images has been in good agreement with practical size in the range of 10% error.

  • PDF

스캐닝 평면 음향 홀로그래피에서의 스펙트럴 분산 보정 (Compensation for Spectral Variance in Scan-Based Planar Acoustical Holography)

  • 권휴상;김용조;;서재갑;박준홍;서상준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.520-524
    • /
    • 2002
  • Multi-reference, scan-based Acoustical Holography is a useful measurement technique when insufficient microphones are available to measure a complete hologram at once. When the sound sources are stationary, the whole hologram can be constructed by joining together sub-holograms captured using a relatively small scan array. Here that approach is extended by the development of a formulation that explicitly includes the acoustical transfer functions between the reference microphones and the scanning microphones. Based on those expressions, a compensation procedure of spectral variance due to source-non-stationarity is proposed. It has been verified both numerically and experimentally that this procedure can help suppress spatially distributed noise caused by the source level non-stationarity that is always present in a measurement.

  • PDF

초음파를 이용한 용접부 핸디 스캔 검사기 개발 (Developement of Ultrasonic Handy Scanner for Welding Inspection)

  • 강동명
    • 한국안전학회지
    • /
    • 제20권3호
    • /
    • pp.14-18
    • /
    • 2005
  • The ultrasonic handy scanner to be developed in this research is a nondestructive inspection equipment with various facility. The ultrasonic inspection is the technique area which apply range is increasing greatly with IT. The purpose of this research is development of a ultrasonic handy scan inspection device with the utility in a work spot. The ultrasonic handy scanner to be developed with portability in this research is able to carry out the spot inspection. It can contribute to the quality improvement, cost reduction and safety design.

콘텐츠 기반 움직임 적응형 디인터레이싱 기법 (A Content-Based Motion Adaptive DeInterlacing Technique)

  • 김민환;이창우;이성원
    • 방송공학회논문지
    • /
    • 제15권6호
    • /
    • pp.791-802
    • /
    • 2010
  • 최근 LCD TV와 같은 순차 주사형 디스플레이의 보급에 따라 HDTV등의 전송에 사용된 비월 주사 영상을 순차 주사 영상으로 변환하는 기존의 디인터레이싱 기술에 대한 화질 개선 요구가 커지고 있다. 본 논문에서는 영상 콘텐츠에 따른 움직임 정보의 통계값을 계산하여 영상 콘텐츠의 종류별로 미리 설정된 임계값에 따라 공간적, 시간적 디인터레이싱 방법을 선택적으로 적용하는 움직임 적응형 디인터레이싱 기법을 제안한다. 또한 공간적 디인터레이싱의 화질을 개선하기 위하여 소벨 연산을 이용하여 수직 에지와 수평 에지의 비율에 따라 M-ELA 방법과 DOI 방법을 선택적으로 사용하는 개선된 공간적 디인터레이싱 방법을 제안한다. 다양한 실험 영상에 대한 객관적, 주관적 평가를 통하여 제안한 방법이 기존의 디인터레이싱 방법에 비해 우수한 화질을 보임을 확인하였다.

CT 유도하 경추부위 경추간공 경막외 스테로이드주입술: 2개월 경과관찰 (CT Guided Cervical Transforaminal Steroid Injection: 2 Months Follow-up)

  • 김훈도;이상호;김명호
    • The Korean Journal of Pain
    • /
    • 제19권1호
    • /
    • pp.51-55
    • /
    • 2006
  • Background: A cervical transforaminal steroid injection is an effective therapeutic modality for radiculopathy of a herniated cervical disc or a cervical foraminal stenosis. However, there is some debate regarding the safety of the transforaminal approach under C-arm guidance compared with the posterior interlaminar approach. We report a new technique for cervical transforaminal steroid injection guided by MDCT. Methods: Patients presenting with radiating pain on their shoulder or arm were diagnosed using CT or MRI of a cervical herniated disc or a foraminal stenosis. Each patient whose symptoms were compatible with the image scan was enrolled in this study. They received a cervical transforaminal steroid injection under CT guidance, and the effectiveness and complications of this technique were evaluated over a 2-month period. Results: According to the CT scan, none of the participants had an internal jugular vein or a carotid artery invasion during the procedure. No vertebral artery injection was noted, and no patient developed a hematoma after the injection. The VAS score had improved significantly by 2, 4 and 8 weeks after the injection. Conclusions: While a conventional C-arm guided cervical transforaminal steroid injection does not appear to differentiate between the major vessels and structures in images, a CT guided approach is a more useful and safer technique for the precise placement of a needle.