• 제목/요약/키워드: Scan technique

검색결과 594건 처리시간 0.026초

연속 스캐닝 레이저 진동계 신호의 Hilbert 변환을 이용한 실험적 모드 해석 (Experimental Modal Analysis by Using Hilbert Transform of Signal from Continuous Scanning Laser Vibrometer)

  • 강민식;장태규;김호성
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권6호
    • /
    • pp.272-277
    • /
    • 2002
  • This paper deals with the vibration deflection shape measurement technique for a sinusoidally excited structure using a continuously scanning laser Doppler vibrometer (CSLV). The CSLV output signal is an amplitude-modulated vibration in which the excitation signal is modulated by the deflection shapes, and thus the deflection shapes of vibration defined along a scan line can be derived by the envelop and the phase information of the CSLV output signal. In this work, a Hilbert transform based approach has been proposed for measurement of deflection shapes. This technique is as simple as the demodulation technique and allows more convenient experimental settings than the Fourier transform approach. The feasibility of the proposed technique is illustrated along with results of experiment.

Digital Authentication Technique using Content-based Watermarking in DCT Domain

  • Hyun Lim;Lee, Myung-Eun;Park, Soon-Young;Cho, Wan-Hyun
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(4)
    • /
    • pp.319-322
    • /
    • 2002
  • In this paper, we present a digital authentication technique using content-based watermarking in digital images. To digest the image contents, Hopfield network is employed on the block-based edge image. The Hopfield function extracts the same tit fur similarly looking blocks so that the values are unlikely to change to the innocuous manipulations while being changed far malicious manipulations. By inputting the extracted bit sequence with secret key to the cryptographic hash function, we generate a watermark for each block by seeding a pseudo random number generator with a hash output Therefore, the proposed authentication technique can distinguish between malicious attacks and innocuous attacks. Watermark embedding is based on the block-based spread spectrum method in DCT domain and the strength of watermark is adjusted according to the local statistics of DCT coefficients in a zig-zag scan line in AC subband. The numerical experiments show that the proposed technique is very efficient in the performance of robust authentication.

  • PDF

Improved Waveform during the Addressing Period for the Improvement of the Addressing Time for AC PDPs

  • Lim, Jong-Sik;Kim, Hyun-Seok;Kim, Joon-Yub
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.511-514
    • /
    • 2004
  • ADS(Address Display period Separation) driving method has been considered to be the most appropriate driving technique for AC PDPs. However when the ADS driving method is applied to the high-resolution AC PDP, the required long addressing time often becomes a problem. In this paper, we present a new waveform for reducing the addressing time and for the stable addressing discharge. In this new waveform, a wall charge acceleration pulse is applied to the common electrode right after 80us scan time. In this way, the charge generated by the addressing discharge is accelerated to the electrodes. Experiments using the wall charge acceleration pulse showed that we could stably address an AC PDP with the scan pulses having pulse width of 1 us

  • PDF

골(骨)스캔에 의한 거골(距骨)의 비패혈성(非敗血性) 괴사진단(壞死診斷) 예(例) (Diagnosis of Aseptic Necrosis of the Talus by Bone Scan; Case Report)

  • 박형근;이명철;고창순;양영식;박원창
    • 대한핵의학회지
    • /
    • 제18권1호
    • /
    • pp.63-65
    • /
    • 1984
  • Bone scan is a very useful technique for detection of aseptic necrosis and frequently used in the detection of aseptic necrosis of the femoral head. We have used this diagnostic tool in a patient to detect aseptic necrosis of the talus, a common complication resulting from foot injuries.

  • PDF

Tc-99m DISIDA SCAN에서 deconvolution 방법을 이용한 간암 환자의 잔여 간 기능의 정량적 평가 (Quantitative evaluation of hepatic function for hepatic cancer patients using deconvolution technique in Tc-99m DISIDA SCAN)

  • 김덕원;김수찬;이종두;한광협
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 추계학술대회
    • /
    • pp.117-120
    • /
    • 1994
  • 수술 전 간 기능이 저하되어 있는 간암환자의 경우 너무 많은 간 조직을 절제하면 남아있는 조직의 기능만으로는 생존하기 어려울 때가 있다 그러므로 수술전 간 기능의 평가를 정확히 할 수 있고 간절제 후에 잔여세포의 기능을 정확히 측정하는 것은 매우 중요한 의미를 갖게 된다. 현재의 일반적인 간 기능 검사나 Indocyanine 등을 이용하는 방법으로는 수술 후 잔여 간세포의 기능을 예측할 수 없다. 그리하여 본 연구에서는 수학적 deconvolution 방법을 이용하여 Hepatic extraction fraction(HEF)를 구하여 수술 후 잔여 간세포의 기능을 정량적으로 예측할 수 있는 software를 개발하고자 한다. 그리하여 간암 환자의 수술여부 및 절제부위의 크기를 결정할 수 있으며 또한 HEF로 신생아 황달의 원인인 간염과 간담도 폐쇄를 식별할 수 있다.

  • PDF

Embedded System One-Hot 시그널의 위치 추적 알고리즘 (Tracking Algorithm about Location of One-Hot Signal in Embedded System)

  • 전유성;김인수;민형복
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1957-1958
    • /
    • 2008
  • The Logic Built In Self Test (LBIST) technique is substantially applied in chip design in most many semiconductor company in despite of unavoidable overhead like an increase in dimension and time delay occurred as it used. Currently common LBIST software uses the MISR (Multiple Input Shift Register) However, it has many considerations like defining the X-value (Unknown Value), length and number of Scan Chain, Scan Chain and so on for analysis of result occurred in the process. So, to solve these problems, common LBIST software provides the solution method automated. Nevertheless, these problems haven't been solved automatically by Tri-state Bus in logic circuit yet. This paper studies the simulator and algorithm that judges whether Tri-state Bus lines is the circuit which have X-value or One-hot Value after presuming the control signal of the lines which output X-value in the logic circuit to solve the most serious problems.

  • PDF

Endodontic treatment of a C-shaped mandibular second premolar with four root canals and three apical foramina: a case report

  • Bertrand, Thikamphaa;Kim, Sahng Gyoon
    • Restorative Dentistry and Endodontics
    • /
    • 제41권1호
    • /
    • pp.68-73
    • /
    • 2016
  • This case report describes a unique C-shaped mandibular second premolar with four canals and three apical foramina and its endodontic management with the aid of cone-beam computer tomography (CBCT). C-shaped root canal morphology with four canals was identified under a dental operating microscope. A CBCT scan was taken to evaluate the aberrant root canal anatomy and devise a better instrumentation strategy based on the anatomy. All canals were instrumented to have a 0.05 taper using 1.0 mm step-back filing with appropriate apical sizes determined from the CBCT scan images and filled using a warm vertical compaction technique. A C-shaped mandibular second premolar with multiple canals is an anatomically rare case for clinicians, yet its endodontic treatment may require a careful instrumentation strategy due to the difficulty in disinfecting the canals in the thin root area without compromising the root structure.

Tc-99m DISIDA SCAN에서 deconvolution 방법을 이용한 외과적 수술 전후의 간의 정량적 평가 (Quantitative evaluation of hepatic function for pre- and post-surgery patients using deconvolution technique in Tc-99m DISIDA SCAN)

  • 김수찬;김덕원
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.366-369
    • /
    • 1997
  • In this study, we measured upper right, lower right, upper left region to find the optimal region which represent liver function. We found that the upper right region is optimal because of high accuracy and low standard deviation. For normal subjects all the calculated HEFs were greater than 100% and all those of abnormal ones were less than 80%. Thus HEF can be assumed to discriminate abnormal livers from normal ones. It was found that the patients with surgical operation would survive if both the pre-and the post-operative HEFs are greater than 50%. Therefore HEF method can be a good estimator for surgeon to determine the surgical operation and to evaluate remaining hepatic function after surgery as well as it is reliable and simple.

  • PDF

임플란트 디지털 인상용 코핑의 정확성 비교 (Comparison of the accuracy of implant digital impression coping)

  • 안교진;이준석
    • 구강회복응용과학지
    • /
    • 제36권1호
    • /
    • pp.29-40
    • /
    • 2020
  • 목적: Encoded healing abutment와 scan body를 이용한 디지털 인상과 pick-up 인상용 코핑을 이용한 인상 채득법의 정확도를 다른 임플란트 식립 각도에서 비교 연구하고자 하였다. 연구 재료 및 방법: 3D 프린터를 이용해 주모형을 제작하고 0°, 10° 및 20°의 근심경사로 3개의 임플란트를 위치 시켰다. 각각의 임플란트에 지대주를 체결하고 주모형을 스캔하여 참조 모델을 만들었다. P군 모델은 pick-up 인상용 코핑을 사용하여 15개의 석고 모형을 만들고 지대주를 장착 후 스캔하여 제작하였다. E군과 S군의 모델은 각각 encoded healing abutment와 scan body를 주모형에 체결하고 구내 스캐너를 이용해 15회씩 인상채득을 하여 제작하였다. 각각의 실험군 STL 파일은 best fit alignment를 이용해 참조 모델과 중첩하였고 root mean square (RMS) 값을 분석하였다. 결과: RMS 값은 P군에서 가장 작았고(25.56 ± 2.53 ㎛), 그다음 S군(35.27 ± 2.56 ㎛), E군(38.29 ± 4.12 ㎛) 순 이었다. S군과 E군 사이에는 유의차가 없었고, P군은 S군과 E군 보다 작았다(P < 0.05). 임플란트 각도와 RMS 값의 상관관계는 E군에서 유의하였다(P < 0.05). 결론:Pick-up 인상용 코핑 방법은 encoded healing abutment와 scan body 인상 채득 방법에 비해 더 높은 정확도를 보였고 encoded healing abutment와 scan body 인상 방법은 정확도에서 유의한 차이가 없었다. Encoded healing abutment의 임상적 사용은 가능하나 경사진 임플란트의 인상의 경우 주의하여 사용해야 할 것으로 사료된다.

영상유도 방사선 치료를 위한 디지털 단층영상합성법의 촬영조건 최적화에 관한 연구 (Optimizing Imaging Conditions in Digital Tomosynthesis for Image-Guided Radiation Therapy)

  • 윤한빈;김진성;조민국;장선영;송영재;김호경
    • 한국의학물리학회지:의학물리
    • /
    • 제21권3호
    • /
    • pp.281-290
    • /
    • 2010
  • 최근 디지털 단층영상합성법을 영상유도 방사선 치료에 활용하기 위한 연구가 활발히 시도되고 있다. 적은 수의 투사영상으로 삼차원 영상재구성이 가능하기 때문에 환자에 대한 피폭선량을 줄일 수 있으며, 환자의 움직임을 최소화할 수 있는 장점이 있기 때문이다. 그러나 단층영상의 화질이 스캔 각도(${\beta}_{scan}$) 및 사용한 투사영상의 수 등 촬영조건에 크게 의존하는 단점이 있다. 본 연구에서는 필터링 후 역투사법을 이용한 디지털 단층영상합성의 구현에 대해 자세히 논하였으며, 이에 대한 최적 촬영조건에 대해 살펴 보았다. 이를 위해 시스템 성능을 신호 대 잡음비, 잔상퍼짐함수, 연산횟수를 조합한 이득함수로 정의하였으며, 다양한 촬영조건에 대해 실험을 통해 각 지표를 구한 후 평가하였다. 평가 결과 및 분석으로부터 큰 단위 스캔 각도(${\Delta}{\beta}$)로 60도 이상의 넓은 범위에 걸쳐 스캔을 할수록 높은 화질의 단층영상을 얻을 수 있다는 결론을 얻었다. 대략적으로 시스템 성능이 $\sqrt{{\Delta}{\beta}}{\times}{\beta}^{2.5}_{scan}$에 비례하였다. 만약 각 평가지표에 명확한 가중치를 부여할 수 있다면 보다 엄밀하고 구체적인 촬영조건을 구할 수 있을 것이다.