• Title/Summary/Keyword: Scan technique

Search Result 594, Processing Time 0.022 seconds

A Study on Quality Assurance for Rotational Molding Products (회전성형 제품의 품질 개선을 위한 연구)

  • Lee, Jung-Ki;Han, Hui-Duck;Kim, Hyun-Joo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.6
    • /
    • pp.826-837
    • /
    • 2004
  • Rotational molding is a plastics processing technique that is ideally suited to producing relatively large, hollow, seamless parts which are partially or totally enclosed. Designers of plastic parts turn to rotational molding to produce small or large parts of unusual shape that cannot be produced as one piece by other processes, e.g., blow molding and thermoforming. In this paper, in order to enhance the quality of rotational molding plastic products, 1) surface features for the plastic products are characterized by using an image analysis system, 2) maximum tensile strength for the plastic products that are made of materials that consist of Samsung-Atofina R90lU, pigments and two different kinds of calcium carbonate (OMYA CaCO$_3$) is measured and compared with each other by using an Instron universal testing machine, 3) thickness for the plastic products is non-destructively measured to investigate the quality of the plastic products by using an A-scan ultrasonic tester.

Detection of Second-Layer Corrosion in Aging Aircraft

  • Kim, Noh-Yu;Yang, Seun-Yong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.6
    • /
    • pp.591-602
    • /
    • 2009
  • The Compton backscatter technique has been applied to lap-joint in aircraft structure in order to determine mass loss due to exfoliative corrosion of the aluminum alloy sheet skin. The mass loss of each layer has been estimated from Compton backscatter A-scan including the aluminum sheet, the corrosion layer, and the sealant. A Compton backscattering imaging system has been also developed to obtain a cross-sectional profile of corroded lap-splices of aging aircraft using a specially designed slit-type camera. The camera is to focus on a small scattering volume inside the material from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the layered structure is scanned by moving the scattering volume through the thickness direction of the specimen. The theoretical model of the Compton scattering based on Boltzmann transport theory is presented for quantitative characterization of exfoliative corrosion through deconvolution procedure using a nonlinear least-square error minimization method. It produces practical information such as location and width of planar corrosion in layered structures of aircraft, which generally cannot be detected by conventional NDE techniques such as the ultrasonic method.

Research and Development of High Performance 42-inch XGA Plasma Display Panel

  • Choi, Kwang-Yeol;Min, Byoung-Kuk;Kim, Tae-Hyung;Song, Byung-Soo;Yoo, Eun-Ho;Kim, Jin-Young;Jung, Yun-Kwon;Kim, Won-Tae;Yang, Hee-Chan;Ryu, Jae-Hwa
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.231-235
    • /
    • 2004
  • High performance 42 inch XGA PDP with high luminance of 1,000 cd/$m^2$ has been developed using high efficient electrode structure, discharge gas and closed barrier ribs. For high speed addressing with single scan technique, address discharge time lag was reduced over 40% with FAST driving scheme and new materials. High dark room contrast ratio of 5,000 : 1 was achieved and picture quality was improved using new algorithm for eliminating false contour and improving gray level linearity.

  • PDF

Creating a digitized database of maxillofacial prostheses (obturators): A pilot study

  • Elbashti, Mahmoud;Hattori, Mariko;Sumita, Yuka;Aswehlee, Amel;Yoshi, Shigen;Taniguchi, Hisashi
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.3
    • /
    • pp.219-223
    • /
    • 2016
  • PURPOSE. This study aimed to create a digitized database of fabricated obturators to be kept for patients' potential emergency needs. MATERIALS AND METHODS. A chairside intraoral scanner was used to scan the surfaces of an acrylic resin obturator. The scanned data was recorded and saved as a single standard tessellation language file using a three-dimensional modeling software. A simulated obturator model was manufactured using fused deposition modeling technique in a three-dimensional printer. RESULTS. The entire obturator was successfully scanned regardless of its structural complexity, modeled as three-dimensional data, and stored in the digital system of our clinic at a relatively small size (19.6 MB). A simulated obturator model was then accurately manufactured from these data. CONCLUSION. This study provides a proof-of-concept for the use of digital technology to create a digitized database of obturators for edentulous maxillectomy patients.

A Case of Traumatic Ventral Hernia Repair with a Porcine Dermal Collagen Graft (Permacol) (외상성 복벽 탈장 환자에서 biologic mesh를 이용한 치료)

  • Yu, Byung Chul;Chung, Min
    • Journal of Trauma and Injury
    • /
    • v.25 no.2
    • /
    • pp.63-66
    • /
    • 2012
  • Resection of the bowel is necessary for the repair of a ventral hernia after recovery from trauma in some cases. In such instances, polyester or polypropylene meshcannot be used due to the possibility of infection; we had to use biological mesh instead. We report a case in which a traumatic hernia was repaired with Permacol (Covidien, Norwalk, CT, USA). A 42-year-old male patient had been injured by a factory machine seven months prior to admission. At that time, he had abdominal wall injury and small bowel perforation. His abdominal wall had been a defect after operation. A CT scan of the abdomen showed that the left abdominal wall, which is lateral to left rectus abdominis muscle had only one muscle layer, an external oblique muscle, and that a previous abdominal incision had a defect along the entire incision. During the exploration, 10 cm of small bowel was removed due to firm adhesion to the previous surgical scar. Permacol mesh was applied and fixed with transfascial fixations and tacks by using the intraperitoneal onlay mesh technique. There were no complications after the surgery and the patient was discharged without any problems.

Image Technique of Surface Defects by Using Photoacoustic Signal Processing (광음향 신호처리를 이용한 표면결함의 영상 기술)

  • Yi, Chong-Ho;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.6
    • /
    • pp.45-49
    • /
    • 1994
  • In this paper, photoacoustic image processing system was constructed by using 2W CW $CO_{2}$ laser of $10.6{\mu}m$ wavelength and PZT 5A acoustic transducer. Stainless steel of 5mm thickness was used as a sample in experiment. Three line cracks of $50{\mu}m$ in each width and depth were made by using plasma on the surface of the sample. Also, each gap among their lines was $200{\mu}m$ and $300{\mu}m$ in width. In the scan range of $2.2mm\times2mm$ including surface defects, a good image of $50{\mu}m$ resolution had been shown when modulation frequency of CW laser was 100Hz.

  • PDF

A Parallel Test Structure for eDRAM-based Tightly Coupled Memory in SoCs (시스템 온 칩 내 eDRAM을 사용한 Tightly Coupled Memory의 병렬 테스트 구조)

  • Kook, In-Sung;Lee, Jae-Min
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.3
    • /
    • pp.209-216
    • /
    • 2011
  • Recently the design of SoCs(System-on-Chips) in which TCM is embedded for high speed operation increases rapidly. In this paper, a parallel test structure for eDRAM-based TCM embedded in SoCs is proposed. In the presented technique, the MUT (Memory Under Test) is changed to parallel structure and it increases testability of MUT with boundary scan chains. The eDRAM is designed in structure for parallel test so that it can be tested for each modules. Dynamic test can be performed based on input-output data. The proposed techniques are verified their performance by circuits simulation.

A Study on Graylevel Image Scanning System Realization Using CIS (CIS를 이용한 그레이레벨 이미지 스케닝시스템 구현에 관한 연구)

  • 김영빈;김윤호;류광렬
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.3
    • /
    • pp.470-474
    • /
    • 2002
  • The graylevel image scanning system realization and design using CIS(Contact image Scanning)be amenable to recognize a papers, OMR and OCR sheet is proposed. The design technique is used CIS scanning sensor in fixing step motor and is optimized with DSP processor for inage processing, and transfer input image data par line in feeding a step unit to PC on the USB interfacer. This system is portable ad A4 size scanning. and keeps image scan processing speed 300mm/sec. The recognition percentage has 98% on the OCR and bar codes.

Using a high-resolution LED display Dual Scanning Image Control System Design (듀얼 스캐닝을 이용한 고해상 LED 전광판 영상제어장치설계)

  • Ha, Young-Jea;Kim, In-Jea;Kim, Sun-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.7
    • /
    • pp.1415-1422
    • /
    • 2011
  • In this paper, full color billboards for the efficient expression of the resolution to offer dual-scanning control method, using the LED display it on a fixed pixel video signal to the pixel dot pattern was changed. And DICT(Dynamic Image Correction Technology) using the main controller in accordance with video information, histogram equalization of image gray scale values to be uniformly distributed, and dynamically improves image quality by converting the area, and a dual auto-scan input video switching controller board as the pixels in the LED Module by controlling the physical manifestation of the existing board LED pixel dots than 4 times the resolution proposes a technique that can be expressed and made it through testing verified the performance.

Bilateral Alternating Bell's Palsy Treated with Stellate Ganglion Block -A case report- (양측 교대형 안면신경 마비의 치험 -증례 보고-)

  • Woo, Young-Cheol;Koo, Gill-Hoi
    • The Korean Journal of Pain
    • /
    • v.11 no.2
    • /
    • pp.326-331
    • /
    • 1998
  • Facial nerve paralysis is a common pain clinical diagnosis. But ipsilateral or contralateral recurrent facial paralysis is found in about 2.6~19.5% of facial paralysis and especially bilateral facial paralysis is rare. While idiopathic facial paralysis is the most common diagnosis, a comprehensive evaluation must be completed prior to this diagnosis in patients with bilateral facial paralysis. A representative case of bilateral alternating facial paralysis treated with stellate ganglion block (SGB) is presented. A 57 years old male patient who had the onset of a right facial paralysis 7 months ago visited pain clinic. Five months after the onset of right facial paralysis, as it was improving, he developed a left facial paralysis. He had history of hypertension, diabetus mellitus and pain episode on mastoid process before facial paralysis developed. Electrical test showed incomplete neuropathy on both side and computed tomography (CT) scan was normal. He was treated with SGB, physical theraphy and aspirin medication. After 25 times SGB, he was recovered almost completely.

  • PDF