• Title/Summary/Keyword: Scan technique

Search Result 594, Processing Time 0.024 seconds

Evaluation of Internal Defect of Composite Laminates Using A Novel Hybrid Laser Generation/Air-Coupled Detection Ultrasonic System (레이저 발생 초음파와 공기 정합 수신 탐촉자를 이용한 복합재료 적층판의 내부 박리 결함 평가)

  • Lee, Joon-Hyun;Lee, Seung-Joon;Byun, Joon-Hyung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.1
    • /
    • pp.46-53
    • /
    • 2008
  • Ultrasonic C-scan technique is one of very popular techniques being used for detection of flaws in polymer matrix composite(PMC). However, the application of this technique is very limited for evaluation of defects in PMC fabricated by the automated fiber placement process. The purpose of this study is to develop a novel ultrasonic hybrid system based on nondestructive and non-contact ultrasonic techniques for evaluation of delamination in carbon/epoxy and carbon/PPS composite laminates. It was shown that the newly developed ultrasonic hybrid system based on dual air-coupled pitch-catch technique with ultrasonic scattering reflection concept could provide excellent image with higher resolution of delamination in PMC compared with the conventional pitch-catch method. It is expected that this ultrasonic hybrid technique can be applied for on-line inspection of flaws in PMC during the fabrication process.

Comparative Analysis of Cervical Lateral Mass Screw Insertion among Three Techniques in the Korean Population by Quantitative Measurements with Reformatted 2D CT Scan Images : Clinical Research

  • Cho, Jae-Ik;Kim, Dae-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.3
    • /
    • pp.124-130
    • /
    • 2008
  • Objective : Our purpose of this study is to compare insertion angles and screw lengths from Roy-Camille, Magerl, and our designed method for cervical lateral mass screw fixation in the Korean population by quantitative measurement of reformatted two dimensional (2D) computed tomography (CT) images. Methods : We selected thirty Korean patients who were evaluated with thin section CT scans and reconstruction program to obtain reformatted 2D-CT images of the transversal plane passing the cranio-caudal angle using three different techniques. We measured the minimum angle to avoid vertebral artery (VA) injury, the ideal angle and depth for bicortical screwing of cervical lateral mass. Morphometric measurements of the lateral masses from C3-C7 were also taken. Results : In all three techniques, the mean safety angles from the VA were less than 8 degrees and the necessary depth of the screw was about 14 mm for safety to the VA and for the bicortical purchase. In our designed technique, the mean $\beta$ angles of each level from C3 to C7 were 29.0. 29.8. 29.5. 26.3. and 23.9 degrees, respectively. Conclusion : Results of this study and data from the literature indicate that differences may exist between the Korean and Western people in the length and angle for ideal lateral mass screw fixation. In addition, our technique needs further cadaveric and clinical study for safety and efficacy for being performed as alternative method for cervical lateral mass fixation.

A Study on the Radiation Exposure Dose of Brain Perfusion CT Examination a Phantom (Phantom을 이용한 뇌 관류 CT검사에서 방사선 피폭선량에 관한 연구)

  • Jung, Hong-Rynag;Kim, Ki-Jeong;Mo, Eun-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.5
    • /
    • pp.287-294
    • /
    • 2015
  • The purpose of this study, was Let's examine the exposure dose at the time of cerebral blood flow CT scan of acute ischemic stroke patients. In particular, long-term high doses of radiation sensitive organs and we Measured using phantom and a glass dosimeter. Apply the existing protocol suggested by the manufacturer (fixed time delay technique) and the proposed new convergence protocol (bolus tracking technique), reporting to measure the dose, dose reduction was to prepare the way. Results up to 39.8% as compared to the existing protocols in a new suggested convergence protocol, a minimum of 5.8% was long-term dose is reduced. Test dose of $CDTI_{vol}$ and DLP values decreased 25%, respectively, were measured at less than recommended dose. Try checking the protocol set out in the existing based on the analysis result of the above, by applying the proposed new convergence protocol by reducing the dose would have to contribute to improved public health. It is believed to be research continues to find the optimum protocol in the other tests.

Implementation of the Feed and Swaddle Technique as a Non-Pharmacological Strategy to Conduct Brain Magnetic Resonance Imaging in Very Low Birth Weight Infants

  • Yoo, Yeong Myong;Park, Ji Eun;Park, Moon Sung;Lee, Jang Hoon
    • Neonatal Medicine
    • /
    • v.28 no.3
    • /
    • pp.108-115
    • /
    • 2021
  • Purpose: Magnetic resonance imaging (MRI) is a useful tool for evaluating brain injury and maturation in preterm infants and often requires sedation to acquire images of sufficient quality. Infant sedation is often associated with adverse events, despite extreme precautions. In this study, the swaddling technique was investigated as an alternative non-pharmacological strategy to obtain brain MRIs of sufficient quality. Methods: We applied the feed and swaddle technique during routine brain MRI as a quality improvement project and compared its morbidity with that of sedation in a historic age-matched group. Seventy-nine very low birth weight infants in the neonatal intensive care unit of Ajou University Hospital (Suwon, Korea) were enrolled. Thirty-two (40.5%) infants were in the feed and swaddling group, and 47 (59.5%) were in the sedation group. Results: The morbidity associated with the cardiopulmonary system (swaddling group vs. sedation group: 53.13% [n=17] vs. 63.83% [n=30], P=0.723) and central nervous system (40.63% [n=13] vs. 29.79% [n=14], P=0.217) were not significantly different between groups. The MRI failure rate was not significantly different (swaddling group vs. sedation group: 12.5% [n=4] vs. 4.3% [n=2], P=0.174). The MRI scanning time was longer in the swaddling group than in the sedation group (76.5±20.3 minutes vs. 61.5±13.6 minutes, P=0.001). Cardiopulmonary adverse events were significantly less common in the swaddling group than in the sedation group (3.13% [n=1] vs. 34.04% [n=16], P=0.002). Conclusion: The success rate of MRI was comparable between the swaddling technique and sedation. Furthermore, despite the drawback of prolonged scan time, cardiopulmonary adverse events are fewer with swaddling than with sedative agents. Therefore, swaddling can be an alternative to sedation or anesthesia when performing neonatal MRI scans.

New Fabrication Method of the Electron Beam Microcolumn and Its Performance Evaluation (초소형 전자칼럼의 제작 및 특성 연구)

  • Ahn S;Kim D. W;Kim Y. C;Ahn S. J;Kim Y. J;Kim H. S
    • Korean Journal of Materials Research
    • /
    • v.14 no.3
    • /
    • pp.186-190
    • /
    • 2004
  • An electron beam microcolumn composed of an electron emitter, micro lenses, scan deflector, and focus lenses have been fabricated and tested in the STEM mode. In this paper, we report a technique of precisely aligning the electron lenses by the laser diffraction patterns instead of the conventional alignment method based on aligner and STM. STEM images of a standard Cu-grid were observed using a fabricated microcolumn under both the retarding and accelerating modes.

Growth and properties of LCMO/YBCO heterostructure

  • Kumar, Manish;Lee, Hyun Hwi
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.151.1-151.1
    • /
    • 2016
  • Complex oxide heterointerfaces have been extensively explored in the past due to the novel phenomenon emerging at such interfaces that differ from their individual bulk counterparts. The integration of a ferromagnetic (FM) material with the superconducting (SC) material leading to proximity effect is one of the commonly studied phenomenon in these heterostructures. In continuation, we have stabilized the FM layer La0.7Ca0.3MnO3 (LCMO) on SC material YBa2Cu3O7-${\delta}$ (YBCO) using pulsed laser deposition technique and explored the structural, magnetic, electrical and magneto-transport properties of this heterostructure. ${\Phi}$-scan measurements confirm the epitaxial nature of LCMO/YBCO heterostructure grown on single crystalline SrTiO3 substrate. The FM transition of LCMO and SC transition of YBCO are observed in the magnetization measurements of the bilayer structure. Through electrical measurements, we understood that the proximity effect leads to lowering of the SC transition of YBCO. The role of interface in the bilayer structure is also realized through electrical transport measurements.

  • PDF

A method of extracting edge line from range image using recognition features (거리 영상에서 인식 특정을 이용한 경계선 검출 기법)

  • 이강호
    • Journal of the Korea Society of Computer and Information
    • /
    • v.6 no.2
    • /
    • pp.14-19
    • /
    • 2001
  • This paper presents a new method of 3-D surface feature extraction using a quadratic pol expression. With a range image, we get an edge map through the modified scan line technique this edge map, we label a 3-dimensional object to divide object's region and extract cent corner points from it's region. Then we determine whether the segmented region is a planar or a curved from the quadric surface equation. we calculate the coefficients of the planar su the curved surface to represent regions. In this article. we prove performance of the metho synthetic and real (Odetics) range images.

An Effective De-Interlacing Technique Using Bi-directional Motion (양방향 움직임을 사용한 효과적인 디인터레이싱 기법)

  • 정유영;고성제
    • Proceedings of the IEEK Conference
    • /
    • 2000.09a
    • /
    • pp.873-876
    • /
    • 2000
  • 본 논문에서는 양방향 움직임 보상에 의한 필드 보간(bi-directional motion-compensated field interpolation) 방법을 사용한 효과적인 디인터레이싱(de-interlacing) 기법을 제안한다. 움직임 추정(motion estimation)을 이용한 일반적인 디인터레이싱 기법은 서로 다른 샘플링 격자(sampling grid) 관계인 연속한 두 필드(field)들간의 움직임 추정을 위해 line average 같은 비교적 간단한 형태의 디인터레이싱 기법이 선행된다. 그러나, 제안한 방법은 보간할 필드(the interpolated field)의 전후 필드들의 같은 샘플링 관계인 존재하는 스캔 라인(the existing scan line)들 사이에서만 움직임 추정이 이루어지므로 구현이 용이하다. 이때 구해진 움직임 벡터는 양방향 움직임 추정을 위한 초기 값으로 사용되어 진다. 제안한 알고리듬은 기존의 움직임 정보를 이용한 기법에 비해 구현이 용이하며, 카메라 움직임이 있는 panning, zooming 영상에 특히 효율적이다.

  • PDF

High-Velocity Impact Damage Detection of Gr/Ep Composite Laminates Using Piezoelectric Thin Film Sensor Signals (압전필름센서 신호를 이용한 Gr/Ep 복합재 적층판의 고속충격 손상탐지)

  • Kim, Jin-Won;Kim, In-Gul
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.13-16
    • /
    • 2005
  • The mechanical properties of composite materials may degrade severely in the presence of damage. Especially, the high-velocity impact such as bird strike, a hailstorm, and a small piece of tire or stone during high taxing, can cause sever damage to the structures and sub-system in spite of a very small mass. However, it is not easy to detect the damage in composite plates using a single technique or any conventional methods. In this paper, the PYDF(polyvinylidene fluoride) film sensors and strain gages were used for monitoring impact damage initiation and propagation in composite laminates. The WT(wavelet transform) and STFT(short time Fourier transform) are used to decompose the sensor signals. A ultrasonic C-scan and a digital microscope are also used to examine the extent of the damage in each case. This research demonstrate how various sensing techniques, PVDF sensor in particular, can be used to characterize high-velocity impact damage in advanced composites.

  • PDF

System Development for Automatic Form Inspecion by Digital Image Processing (디지탈 이미지프로세싱을 이용한 자동외관검사장치 개발)

  • 유봉환
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.5 no.2
    • /
    • pp.57-62
    • /
    • 1996
  • Basically, the idea underlying most edge-detection technique is the computation of a local derivative operator used for edge detection in gray level image. This concept can be easily illustrated with the aid of object which shows an image of a simple lilght on a dark background, Using the gray level profile along a horizontal scan line of the image. the first and second derivatives of it were acquired. This study is to develop an automatic measuring system based on the digital image processing which can be applied to the real time measurement of the characteristics of the ultra-thin thickness. The experimental results indicate that the developed automatic inspection can be applied in real situation.

  • PDF