• Title/Summary/Keyword: Scan technique

Search Result 594, Processing Time 0.024 seconds

Development of Green-Sheet Measurement Algorithm by Image Processing Technique (영상처리기법을 이용한 그린시트 측정알고리즘 개발)

  • Pyo, C.R.;Yang, S.M.;Kang, S.H.;Yoon, S.M.
    • Transactions of Materials Processing
    • /
    • v.16 no.4 s.94
    • /
    • pp.313-316
    • /
    • 2007
  • The purpose of this paper is the development of measurement algorithm for green-sheet based on the digital image processing technique. The Low Temperature Co-fired Ceramic(LTCC) technology can be employed to produce multilayer circuits with the help of single tapes, which are used to apply conductive, dielectric and/or resistive pastes on. These single green-sheets must be laminated together and fired at the same time. Main function of the green-sheet film measurement algorithm is to measure the position and size of the punching hole in each single layer. The line scan camera coupled with motorized X-Y stage is used. In order to measure the entire film area using several scanning steps, an overlapping method is used.

Higher Order Shimming for Ultra-fast Spiral-Scan Imaging at 3 Tesla MRI System (3 Tesla MRI 시스템에서 초고속 나선주사영상을 위한 고차 shimming)

  • Kim, P.K.;Lim, J.W.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.2
    • /
    • pp.95-102
    • /
    • 2007
  • Purpose: To acquire high-resolution spiral-scan images at higher magnetic field, high homogeneous magnetic field is needed. Field inhomogeneity mapping and in-vivo shimming are important for rapid imaging such as spiral-scan imaging. The rapid scanning sequences are very susceptible to inhomogeneity. In this paper, we proposed a higher-order shimming method to obtain homogeneous magnetic field. Materials and Methods: To reduce measurement time for field inhomogeneity mapping, simultaneous axial/ sagittal, and coronal acquisitions are done using multi-slice based Fast Spin echo sequence. Acquired field inhomogeneity map is analyzed using the spherical harmonic functions, and shim currents are obtained by the multiplication of the pseudo-inverse of the field pattern with the inhomogeneity map. Results: Since the field inhomogeneity is increasing in proportion to the magnetic field, higher order shimming to reduce the inhomogeneity becomes more important in high field imaging. The shimming technique in which axial, sagittal, and coronal section inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the imhomogenity map is applied. The proposed technique is applicable to a localized shimming as well. High resolution spiral-scan imaging was successfully obtained with the proposed higher order shimming. Conclusion: Proposed pulse sequence for rapid measurement of inhomogeneity map and higher order shimming based on the inhomogeneity map work very well at 3 Tesla MRI system. With the proposed higher order shimming and localized higher order shimming techniques, high resolution spiral-scan images are successfully obtained at 3 T MRI system.

  • PDF

A study on Computer-controlled Ultrasonic Scanning Device (컴퓨터제어에 의한 자동초음파 탐상장치에 관한 연구)

  • Huh, H.;Park, C.S.;Hong, S.S.;Park, J.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.9 no.1
    • /
    • pp.30-38
    • /
    • 1989
  • Since the nuclear power plants in Korea have been operated in 1979, the nondestructive testing (NDT) of pressure vessels and/or piping welds plays an important role for maintaining the safety and integrity of the plants. Ultrasonic method is superior to the other NDT method in the viewpoint of the detectability of small flaw and accuracy to determine the locations, sizes, orientations, and shapes. As the service time of the nuclear power plants is increased, the radiation level from the components is getting higher. In order to get more quantitative and reliable results and secure the inspector from the exposure to high radiation level, automation of the ultrasonic equipments has been one of the important research and development(R & D) subject. In this research, it was attempted to visualize the shape of flaws presented inside the specimen using a Modified C-Scan technique. In order to develope Modified C-Scan technique, an automatic ultrasonic scanner and a module to control the scanner were designed and fabricated. IBM-PC/XT was interfaced to the module to control the scanner. Analog signals from the SONIC MARK II were digitized by Analog-Digital Converter(ADC 0800) for Modified C-Scan display. A computer program has been developed and has capability of automatic data acquisition and processing from the digital data, which consist of maximum amplitudes in each gate range and locations. The data from Modified C-Scan results was compared with shape from artificial defects using the developed system. Focal length of focused transducer was measured. The automatic ultrasonic equipment developed through this study is essential for more accurate, reliable, and repeatable ultrasonic experiments. If the scanner are modified to meet to appropriate purposes, it can be applied to automation of ultrasonic examination of nuclear power plants and helpful to the research on ultrasonic characterization of the materials.

  • PDF

A Clustered Reconfigurable Interconnection Network BIST Based on Signal Probabilities of Deterministic Test Sets (결정론적 테스트 세트의 신호확률에 기반을 둔 clustered reconfigurable interconnection network 내장된 자체 테스트 기법)

  • Song Dong-Sup;Kang Sungho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.12
    • /
    • pp.79-90
    • /
    • 2005
  • In this paper, we propose a new clustered reconfigurable interconnect network (CRIN) BIST to improve the embedding probabilities of random-pattern-resistant-patterns. The proposed method uses a scan-cell reordering technique based on the signal probabilities of given test cubes and specific hardware blocks that increases the embedding probabilities of care bit clustered scan chain test cubes. We have developed a simulated annealing based algorithm that maximizes the embedding probabilities of scan chain test cubes to reorder scan cells, and an iterative algorithm for synthesizing the CRIN hardware. Experimental results demonstrate that the proposed CRIN BIST technique achieves complete fault coverage with lower storage requirement and shorter testing time in comparison with the conventional methods.

Optimization of Laser Photolithography Micromachining Technique based on Taguchi Method (다구찌 방법을 이용한 레이저 포토리소그라피 미세패턴가공 기술의 최적화)

  • Baek, Nam-Kook;Kim, Dae-Eun
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.871-875
    • /
    • 2001
  • Laser photolithography technique is useful for fabricating micro-patterns of silicon wafers. In this work, the laser photolithography micromachining technique is optimized based on Taguchi method. Sensitivity analysis was performed using laser scanning speed and laser power level as the parameters. The results show that for the photoresist used in this work, a laser scan speed of $70{\mu}m/s$ at 50mW laser power gives the best result.

  • PDF

B-Scan Image Processing Technique by Using Ultrasonic Microscope System (초음파 현미경 시스템에 의한 B-스캔 영상처리 기술)

  • 고대식;전계석
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.12
    • /
    • pp.1889-1893
    • /
    • 1990
  • In this paper, ultrasonic microscope system has been constructed with the small aperturre acoustic lens and the angle controller, and the new type of B-scanultransonic imaging has been analyzed. The system with small aperture lens was used to detect flaw existing within the thick specimen and its resolution was in the range of one wavelength at interior plane of sample. The anle controller was used to excited surface acoustic wave or shear wave. In order to obtain B-scan image of the flaw existig at interior of solids, shear wave has been excited and backscattering signals from the flaw have been processed. In experimental results, B-scan ultransonic images have been obtain from the flaws of varable shape and measured flaw size from the images has been in good agreement with practical size in the range of 10% error.

  • PDF

Compensation for Spectral Variance in Scan-Based Planar Acoustical Holography (스캐닝 평면 음향 홀로그래피에서의 스펙트럴 분산 보정)

  • ;;J. S. Bolton
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.520-524
    • /
    • 2002
  • Multi-reference, scan-based Acoustical Holography is a useful measurement technique when insufficient microphones are available to measure a complete hologram at once. When the sound sources are stationary, the whole hologram can be constructed by joining together sub-holograms captured using a relatively small scan array. Here that approach is extended by the development of a formulation that explicitly includes the acoustical transfer functions between the reference microphones and the scanning microphones. Based on those expressions, a compensation procedure of spectral variance due to source-non-stationarity is proposed. It has been verified both numerically and experimentally that this procedure can help suppress spatially distributed noise caused by the source level non-stationarity that is always present in a measurement.

  • PDF

Developement of Ultrasonic Handy Scanner for Welding Inspection (초음파를 이용한 용접부 핸디 스캔 검사기 개발)

  • Kang, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.14-18
    • /
    • 2005
  • The ultrasonic handy scanner to be developed in this research is a nondestructive inspection equipment with various facility. The ultrasonic inspection is the technique area which apply range is increasing greatly with IT. The purpose of this research is development of a ultrasonic handy scan inspection device with the utility in a work spot. The ultrasonic handy scanner to be developed with portability in this research is able to carry out the spot inspection. It can contribute to the quality improvement, cost reduction and safety design.

A Content-Based Motion Adaptive DeInterlacing Technique (콘텐츠 기반 움직임 적응형 디인터레이싱 기법)

  • Kim, Min-Hwan;Lee, Chang-Woo;Lee, Seong-Won
    • Journal of Broadcast Engineering
    • /
    • v.15 no.6
    • /
    • pp.791-802
    • /
    • 2010
  • Recent prevalence of progressive scan display such as LCD TV demands the quality improvement of existing deinterlacing techniques that convert interlaced scan images including HDTV broadcasting to progressive scan images. In this paper, we proposea motion adaptive deinterlacing technique which can be used for spatial methods, temporal methods, and the spatial-temporal methods can be used for the deinterlacing techniques selectively based on the threshold values calculated by the statistics of motion in the video contents. We also propose an improved spatial deinterlacing technique that adaptively use M-ELA and DOI based on the slant of edges that are obtained by Sobel operation. The improved picture quality of the proposed algorithm is confirmed by objective and subjective quality tests on many test image sequences.

CT Guided Cervical Transforaminal Steroid Injection: 2 Months Follow-up (CT 유도하 경추부위 경추간공 경막외 스테로이드주입술: 2개월 경과관찰)

  • Kim, Hoondo;Lee, Sang Ho;Kim, Myung-Ho
    • The Korean Journal of Pain
    • /
    • v.19 no.1
    • /
    • pp.51-55
    • /
    • 2006
  • Background: A cervical transforaminal steroid injection is an effective therapeutic modality for radiculopathy of a herniated cervical disc or a cervical foraminal stenosis. However, there is some debate regarding the safety of the transforaminal approach under C-arm guidance compared with the posterior interlaminar approach. We report a new technique for cervical transforaminal steroid injection guided by MDCT. Methods: Patients presenting with radiating pain on their shoulder or arm were diagnosed using CT or MRI of a cervical herniated disc or a foraminal stenosis. Each patient whose symptoms were compatible with the image scan was enrolled in this study. They received a cervical transforaminal steroid injection under CT guidance, and the effectiveness and complications of this technique were evaluated over a 2-month period. Results: According to the CT scan, none of the participants had an internal jugular vein or a carotid artery invasion during the procedure. No vertebral artery injection was noted, and no patient developed a hematoma after the injection. The VAS score had improved significantly by 2, 4 and 8 weeks after the injection. Conclusions: While a conventional C-arm guided cervical transforaminal steroid injection does not appear to differentiate between the major vessels and structures in images, a CT guided approach is a more useful and safer technique for the precise placement of a needle.