• 제목/요약/키워드: Scan range

검색결과 474건 처리시간 0.028초

스플라인 보간법을 이용한 스캔 변환기 설계 (DESIGN OF A SCAN CONVERTER SUING SPLINE INTERPOLATION)

  • 이범근
    • 한국시뮬레이션학회:학술대회논문집
    • /
    • 한국시뮬레이션학회 2000년도 춘계학술대회 논문집
    • /
    • pp.91-95
    • /
    • 2000
  • The purpose of format conversion is to convert a wide range of personal computer video formats to a target format. Circuits for the conversion has been developed by means of interpolation techniques, such as zero-order interpolation, bilinear interpolation, and bisigmoidal interpolation. This paper proposes a scan converter using cubic splines. The converter was modeled in VHDL on Max+Plus II and implemented with an FPGA cpip. The circuit gives much better conversion performance than a scan converter with zero-order or linear interpolation.

  • PDF

초음파 현미경 시스템에 의한 B-스캔 영상처리 기술 (B-Scan Image Processing Technique by Using Ultrasonic Microscope System)

  • 고대식;전계석
    • 대한전자공학회논문지
    • /
    • 제27권12호
    • /
    • pp.1889-1893
    • /
    • 1990
  • In this paper, ultrasonic microscope system has been constructed with the small aperturre acoustic lens and the angle controller, and the new type of B-scanultransonic imaging has been analyzed. The system with small aperture lens was used to detect flaw existing within the thick specimen and its resolution was in the range of one wavelength at interior plane of sample. The anle controller was used to excited surface acoustic wave or shear wave. In order to obtain B-scan image of the flaw existig at interior of solids, shear wave has been excited and backscattering signals from the flaw have been processed. In experimental results, B-scan ultransonic images have been obtain from the flaws of varable shape and measured flaw size from the images has been in good agreement with practical size in the range of 10% error.

  • PDF

2차원 격자 오차 데이터 기반의 선형 보정 함수들을 이용한 적외선 레인지 파인더 PBS-03JN의 보정 (alibration of Infra-red Range Finder PBS-03JN Using Piecewise Linear Function Based on 2-D Grid Error)

  • 김진백;김병국
    • 제어로봇시스템학회논문지
    • /
    • 제17권9호
    • /
    • pp.922-931
    • /
    • 2011
  • An efficient calibration algorithm for mobile robot localization using infrared range finder is proposed. A calibration is important to guarantee the performance of other algorithms which use sensor data because it is pre-process. We experimentally found that the infrared range finder PBS-03JN has error characteristics depending on both distance and scan angle. After obtaining 2-D grid error characteristic data on distance and scan angle, we proposed a simple and efficient calibration algorithm with a 2-D piecewise linear function set. The performance of our proposed calibration algorithm is verified by experiments and simulation.

개방형 도파관 배열안테나의 조향소자 특성 (Scan Element Characteristics of Open-Ended Waveguide Array Antenna)

  • 김동석;김태현;박동철;김찬홍
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2005년도 종합학술발표회 논문집 Vol.15 No.1
    • /
    • pp.347-352
    • /
    • 2005
  • Scan Element Pattern(SEP) and Scan Impedance(SI) concepts are used to analyze the characteristics of open-ended waveguide array, which is the representative phased array antenna element in C-band and X-band. Transmit SEP's are calculated for 15$\sim$15 subarray and SI's are obtained by applying periodic boundary conditions for a unit cell of the given array condition. CST's MWS and Ansoft's HFSS are utilized for each analysis. Some relations are reviewed between the two results, which are based on mutual coupling effects. For validation purpose, an 8$\sim$8 subarray is constructed and tested. Transmit SEP measured in MTG's far-field range shows good agreement with the calculated transmit SEP.

  • PDF

감염성 골질환의 핵의학 영상진단 (Nuclear Medicine Imaging Diagnosis in Infectious Bone Diseases)

  • 최윤영
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제40권4호
    • /
    • pp.193-199
    • /
    • 2006
  • Infectious and inflammatory bone diseases include a wide range of disease process, depending on the patient's age, location of infection, various causative organisms, duration from symtom onset, accompanied fracture or prior surgery, prosthesis insertion, and underlying systemic disease such as diabetes, etc. Bone infection may induce massive destruction of bones and joints, results in functional reduction and disability. The key to successful management is early diagnosis and proper treatment. Various radionuclide imaging methods including three phase bone scan, Ga-67 scan, WBC scan, and combined imaging techniques such as bone/Ga-67 scan, WBC/bone marrow scan add complementary role to the radiologic imaging modalities including plain radiography, CT and MRI. F-18 FDG PET imaging also has recently been introduced in diagnosis of infected prosthesis and chronic active osteomyelitis. Selection of proper nuclear medicine imaging method will improve the diagnostic accuracy of infections and inflammatory bone diseases, based on understading of pathogenesis and radiologic imaging findings.

2차원 레이저 거리계를 이용한 수직/수평 다각평면 기반의 위치인식 및 3차원 지도제작 (3D Simultaneous Localization and Map Building (SLAM) using a 2D Laser Range Finder based on Vertical/Horizontal Planar Polygons)

  • 이승은;김병국
    • 제어로봇시스템학회논문지
    • /
    • 제20권11호
    • /
    • pp.1153-1163
    • /
    • 2014
  • An efficient 3D SLAM (Simultaneous Localization and Map Building) method is developed for urban building environments using a tilted 2D LRF (Laser Range Finder), in which a 3D map is composed of perpendicular/horizontal planar polygons. While the mobile robot is moving, from the LRF scan distance data in each scan period, line segments on the scan plane are successively extracted. We propose an "expected line segment" concept for matching: to add each of these scan line segments to the most suitable line segment group for each perpendicular/horizontal planar polygon in the 3D map. After performing 2D localization to determine the pose of the mobile robot, we construct updated perpendicular/horizontal infinite planes and then determine their boundaries to obtain the perpendicular/horizontal planar polygons which constitute our 3D map. Finally, the proposed SLAM algorithm is validated via extensive simulations and experiments.

뇌전산화단층검사에서 방사선량 저감을 위한 최적화 프로토콜 연구 (Optimization of Brain Computed Tomography Protocols to Radiation Dose Reduction)

  • 이재승;권대철
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권3호
    • /
    • pp.116-123
    • /
    • 2018
  • This study is a model experimental study using a phantom to propose an optimized brain CT scan protocol that can reduce the radiation dose of a patient and remain quality of image. We investigate the CT scan parameters of brain CT in clinical medical institutions and to measure the important parameters that determine the quality of CT images. We used 52 multislice spiral CT (SOMATOM Definition AS+, Siemens Healthcare, Germany). The scan parameters were tube voltage (kVp), tube current (mAs), scan time, slice thickness, pitch, and scan field of view (SFOV) directly related to the patient's exposure dose. The CT dose indicators were CTDIvol and DLP. The CT images were obtained while increasing the imaging conditions constantly from the phantom limit value (Q1) to the maximum value (Q4) for AAPM CT performance evaluation. And statistics analyzed with Pearson's correlation coefficients. The result of tube voltage that the increase in tube voltage proportionally increases the variation range of the CT number. And similar results were obtained in the qualitative evaluation of the CT image compared to the tube voltage of 120 kVp, which was applied clinically at 100 kVp. Also, the scan conditions were appropriate in the tube current range of 250 mAs to 350 mAs when the tube voltage was 100 kVp. Therefore, by applying the proposed brain CT scanning parameters can be reduced the radiation dose of the patient while maintaining quality of image.

CareDose 4D 사용 시 동일한 스캔조건에서 조직기반설정을 다르게 적용함에 따른 선량 비교: 성인과 소아팬텀 연구 (Radiation Dose Comparison according to Different Organ Characteristics at Same Scan Parameters Using CareDose 4D: An Adult and Pediatric Phantom Evaluation)

  • 공효금;이기백
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권4호
    • /
    • pp.271-277
    • /
    • 2019
  • CareDose 4D which is the Siemens's Automatic Exposure Control (AEC) can adjust the level of radiation dose distribution which is based on organ characteristic unlike other manufacturer's AEC. Currently, a wide scan range containing different organs is sometimes examined at once (defined as one scan). The purpose of this study was to figure out which organ characteristic option is suitable when one scan method is utilized. Two types of anthropomorphic phantoms were scanned in the same range which were from frontal bone to carina level according to three different organ characteristics such as Thorax, Abdomen, and Neck. All scans and image reconstruction parameters were equally applied and radiation dose were compared. Radiation dose with Thorax organ characteristic was lower than that with Neck. Also, that with Abdomen oran characteristic was lower than Thorax. There were significant differences in radiation dose according to different organ characteristics at the same parameters (P<0.05). Usage of Neck organ characteristic had a result of the highest radiation dose to all phantom. On the other hand, utilization of Abdomen organ characteristic showed the lowest radiation dose. As a result, it is desirable to set appropriate organ characteristic according to examined body part when you checkup patients. Also, when you implement one scan method, selection of Abdomen-based organ characteristic has reduced more radiation dose compared with two different organ characteristic.

Dosimetric Characteristics of Flexible Radiochromic Film Based on LiPCDA

  • Jung, Seongmoon;Cho, Jin Dong;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.179-184
    • /
    • 2021
  • This study aimed to determine the optimal thickness of the active layer and scan mode for a flexible radiochromic film (F-RCF) based on the active lithium salt of pentacosa-10,12-diynoic acid (LiPCDA). F-RCFs of 90, 120, 140, and 170-㎛ thickness were fabricated using LiPCDA. Several pieces of the F-RCFs were exposed to doses ranging from 0 to 3 Gy. Transmission and reflection modes were used to scan the irradiated F-RCFs. Their dose-response curves were obtained using a second-order polynomial equation. Their sensitivity was evaluated for both scanning modes, and the uniformity of the batch was also examined. For both the transmission and reflection modes, the sensitivity increased as the film thickness increased. For the reflection mode, the dose response increased dramatically under 1 Gy. The value of the net optical density varied rapidly as the thickness of the film increased. However, the dose-response curves showed a supralinear-curve relationship at doses greater than 2 Gy. The sensitivity of the reflection scan at doses greater than 2 Gy was higher than that of the reflection scan within 0-2 Gy. The sensitivity steadily decreased with increasing doses, and the sensitivity of the two modes was within 0.1 to 0.2 at 2 Gy and was saturated beyond that. For the transmission scan, the sensitivity was approximately 0.2 at 3 Gy. For the intra-batch test result, the maximum net optical density difference of the intra-batch was 5.5% at 2 Gy and 7.4% at 0.2 Gy in the transmission and reflection scans, respectively. In the low-dose range, film thickness of more than 120-㎛ was proper in the transmission mode. In contrast, the transmission mode showed a better result compared to the reflection mode. Therefore, the proper scan mode should be selected according to the dose range.

액정 표시기의 화질 향상을 위한 중첩구동방식의 최적화에 관한 연구 (A Study on the optimization of overlap scanning method for the enhancement of display quality in LC Displays)

  • 최선정;김용득
    • 전자공학회논문지B
    • /
    • 제32B권10호
    • /
    • pp.1280-1285
    • /
    • 1995
  • In this paper the optimized overlap driving scheme for improving the reduction problem of the operating voltage range occured by the overlap driving scheme proposed precedently and increasing the contrast ratio of screen image in the simple matrix LCDs is proposed. The characteristic estimation of the proposed method was performed in a condition that the number of scan electrodes was 120 and the threshold voltage of LC pixel was 2V and the overlap rate of scan signal was varied from 0% to 40% . As a result of estimation compared with the overlap driving scheme proposed precedently, this new method was certified as a method which it could increase the operating voltage range of the LC pixel by 16% in 20% overlap condition and it's operating voltage range was also increased very much with the increase of the overlap rate. Consequently this newly proposed method was certified as a method which it could maintain the improvement effect of the operating characteristics obtained by the overlap driving scheme proposed precedently with the big improvement in the contrast ratio of screen image.

  • PDF