• Title/Summary/Keyword: Scan order

Search Result 587, Processing Time 0.029 seconds

Development of Thermal Imaging Observation System (관측용 열상장비의 개발)

  • Hong, S.M.;Song, I.S.;Kim, C.W.;Kim, H.S.;Kim, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.543-545
    • /
    • 1993
  • This paper decribed the development of Thermal Imaging Oservation System(TIOS) using the serial-parallel scan method. The detectors scan five lines at a tine. These are put into serial order by electronic scan converter. Digital memory and high speed multiplexer are used for the serial conversion instead of charge coupled devices. As a result, thermal imaging system be presented with exellent performance which MRTD value is less than $0.5^{\circ}K$ at 7.5 cycles/mm.

  • PDF

COMPARISON OF IMAGE REFORMATION USING PERSONAL COMPUTER WITH CT SCAN RECONSTRUCTION (CT 스캔 영상재구성과 개인용 컴퓨터를 이용한 영상 재형성과의 비교에 관한 연구)

  • Jung Gi-Hun;Kim Eun-Kyung;Kim Sang-Joon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.361-368
    • /
    • 1994
  • Radiographic planning is needed for implant placement in order to determine implant length, jaw bone volume, anatomical stucture and so on. Radiographic examination includes conventional radiography, conventional tomography and CT scan. The most accurate mesurement can be obtained from CT scan. For the cross-sectional view of mandible, CT scan reconstruction is generally needed. But the cross-sectional view of mandible can be reformed by personal computer. This study was performed to examine the clinical usefulness of reformed image using personal computer in comparison with CT scan reconstructed image. CT axial slices of 4 mandibles of 4 volunteers were used. Digital imaging system was composed of Macintosh Ⅱ ci computer, high resolution Sony XC-77 CCD camera, Quick Capture frame grabber board and 'NIH Image' program. Seven reconstructed cross-sectional images within CT machine(CT group) were obtained. And seven reformed cross-sectional images(PC group) after digitization of CT axial slices into the personal computer were obtained. PC group was compared with CT group in the objective and subjective aspects. The results were as follow: 1. Measurement of mandibular height & width in both group showed insignificant difference(P>0.05). 2. Subjective assessment of the mandibular canal in both group showed insignificant difference(P>0.05). 3. Image reformation using personal computer could provide panoramic view, which could not be obtained in CT scan reconstruction.

  • PDF

Usefulness of Audio-visual Methods that is used to Customer to Help Smooth Public Prosecutor at CT Examination (CT Scan Positioning시 고객의 검사진행의 이해를 돕기 위한 시청각 자료의 유용성)

  • Ahn, Hyeong-Taek;Jeon, Jung-Keun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.2
    • /
    • pp.17-22
    • /
    • 2008
  • It is to improve customer satisfaction measurement and CT Scan process without delay of examination time when is using Scan positioning time(Planning time) that time is happened always between research reactor CT examination to increase fear and examination satisfaction by the customer's comprehension tribe which get the latest contrast enhancement CT examination. Needs and interests that customer wants to compose visual and auditory Contents to be played to Scan positioning time did questionnaire about curiosity later before CT examination to 600 people for October - November 2 months of 2006 to customer whole that get CT examination on source. Data getting through questionnaire investigated examination comprehension and satisfaction through questionnaire after experiment Scan Positioning to 500 coming to help customers to be source CT examination for 3 months February December - 2007 year in 2006 manufacturing Voice and Visual announce media for reference. To customer who interest degree appeared, and answers preparatory audit from preparatory audit about curiosity of CT examination customer to order of examination time required(43%), contrast media side effect(26%), examination region(20%), breath(10%), etc..(1.5%) audio-visual materials in questionnaire that attain after do reclamation among examination age, sex, reception type of irrelatively in 91% of target increase of hailing degree and examination satisfaction appear. Searched that customer hailing and satisfaction are increased greatly when use of audio-visual materials in satisfaction result that use CT Positioning delay time. In experiment process, It took lacking part by method that use hearing in case of do not use sight as is unavoidable in subject position or old age. Through this, audio-visual materials could analogize that it is more useful method that use sight and hearing at the same time.

  • PDF

Study on Tensile Properties of AlSi10Mg produced by Selective Laser Melting (SLM 공정 기법으로 제작한 AlSi10Mg 인장특성에 관한 연구)

  • Kim, Moosun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.25-31
    • /
    • 2018
  • Selective Laser Melting is one of the representative 3D printing techniques for handling metal materials. The main factors influencing the characteristics of structures fabricated by the SLM method include the build-up angle of structures, laser power, laser scan speed, and scan spacing. In this study, the tensile properties of AlSi10Mg alloys were investigated by considering the build-up angle of tensile test specimens, laser scanning speed and scan spacing as variables. The yield stress, tensile strength, and elongation were considered as tensile properties. From the test results, it was confirmed that the yield stress values were lowered in the order of 0, 45, and 90 based on the manufacturing direction of the tensile specimen. The maximum yield stress value was obtained at 1870 mm / min based on the laser scan speed. The yield stress size decreased with decreasing scan speed. Based on the laser scan spacing, as the value increases, the yield stress increases, but the variation is smaller than the other test criteria. The tendency of the tensile strength and elongation variation depending on the test conditions was difficult to understand.

Dosimetric Characteristics of Flexible Radiochromic Film Based on LiPCDA

  • Jung, Seongmoon;Cho, Jin Dong;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.179-184
    • /
    • 2021
  • This study aimed to determine the optimal thickness of the active layer and scan mode for a flexible radiochromic film (F-RCF) based on the active lithium salt of pentacosa-10,12-diynoic acid (LiPCDA). F-RCFs of 90, 120, 140, and 170-㎛ thickness were fabricated using LiPCDA. Several pieces of the F-RCFs were exposed to doses ranging from 0 to 3 Gy. Transmission and reflection modes were used to scan the irradiated F-RCFs. Their dose-response curves were obtained using a second-order polynomial equation. Their sensitivity was evaluated for both scanning modes, and the uniformity of the batch was also examined. For both the transmission and reflection modes, the sensitivity increased as the film thickness increased. For the reflection mode, the dose response increased dramatically under 1 Gy. The value of the net optical density varied rapidly as the thickness of the film increased. However, the dose-response curves showed a supralinear-curve relationship at doses greater than 2 Gy. The sensitivity of the reflection scan at doses greater than 2 Gy was higher than that of the reflection scan within 0-2 Gy. The sensitivity steadily decreased with increasing doses, and the sensitivity of the two modes was within 0.1 to 0.2 at 2 Gy and was saturated beyond that. For the transmission scan, the sensitivity was approximately 0.2 at 3 Gy. For the intra-batch test result, the maximum net optical density difference of the intra-batch was 5.5% at 2 Gy and 7.4% at 0.2 Gy in the transmission and reflection scans, respectively. In the low-dose range, film thickness of more than 120-㎛ was proper in the transmission mode. In contrast, the transmission mode showed a better result compared to the reflection mode. Therefore, the proper scan mode should be selected according to the dose range.

Need of Two Planes of CT Scan for Evaluation of Orbital Blowout Fracture Reconstruction (안와파열골절의 수술결과 평가에서 두 단면의 CT영상 필요성)

  • Lee, Soo Hyang;Burm, Jin Sik;Kim, Yang Woo
    • Archives of Plastic Surgery
    • /
    • v.32 no.2
    • /
    • pp.194-198
    • /
    • 2005
  • In many reports on the reconstruction of an orbital blowout fracture, CT(computed tomography) imaging has been used for postoperative evaluation. However, in most cases, only one plane of the CT scan was presented, which may not be sufficient for accurate evaluation. This study reviewed the CT scans presented in the related 49 articles (56 cases), and investigated our patients (150 cases) to investigate where were the most frequent unfavorable reconstructions, and to determine which planes should be presented for accurate evaluation. One plane of the CT scan was presented in 70% of the cases. On the other hand, 30% of the cases presented two planes of the CT scans. In our cases, the most prevalent sites for an unfavorable reconstruction were the posterior portion of the inferior wall, and the posterior and the inferior portion of the medial wall. In order to accurately evaluate an orbital wall reconstruction, at least two planes of a CT scan are needed. For an inferior wall evaluation, both the middle and the posterior planes of the coronal section or both the coronal and the sagittal sections are necessary. In addition, for the medial wall evaluation, both the axial and the coronal sections or both the middle and the posterior planes of the coronal section are required.

Approximation of Frequent Itemsets with Maximum Size by One-scan for Association Rule Mining Application (연관 규칙 탐사 응용을 위한 한 번 읽기에 의한 최대 크기 빈발항목 추정기법)

  • Han, Gab-Soo
    • The KIPS Transactions:PartD
    • /
    • v.15D no.4
    • /
    • pp.475-484
    • /
    • 2008
  • Nowadays, lots of data mining applications based on continuous and online real time are increasing by the rapid growth of the data processing technique. In order to do association rule mining in that application, we have to use new techniques to find the frequent itemsets. Most of the existing techniques to find the frequent itemsets should scan the total database repeatedly. But in the application based on the continuous and online real time, it is impossible to scan the total database repeatedly. We have to find the frequent itemsets with only one scan of the data interval for that kind of application. So in this paper we propose an approximation technique which finds the maximum size of the frequent itemsets and items included in the maximum size of the frequent itemsets for the processing of association rule mining.

Study on the FPCS for Photoresist Coating of Semiconductor Manufacturing Process (반도체 생산공정의 감광액 도포를 위한 FPCS에 관한 연구)

  • Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4467-4471
    • /
    • 2013
  • In this research, developed full-scan photoresist coating system(FPCS) can improve the efficiency of the photoresist coating system essential for spinner equipment in nano semiconductor manufacturing process. The devices developed in this research, which can be swiftly replaced in case abnormal state element changes or wafer manufacturing defect occurs, are anticipated to improve module yield as well as real-time monitoring on the state element in order to prevent the complex process defect due to the photoresist miss coating.

A study on Computer-controlled Ultrasonic Scanning Device (컴퓨터제어에 의한 자동초음파 탐상장치에 관한 연구)

  • Huh, H.;Park, C.S.;Hong, S.S.;Park, J.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.9 no.1
    • /
    • pp.30-38
    • /
    • 1989
  • Since the nuclear power plants in Korea have been operated in 1979, the nondestructive testing (NDT) of pressure vessels and/or piping welds plays an important role for maintaining the safety and integrity of the plants. Ultrasonic method is superior to the other NDT method in the viewpoint of the detectability of small flaw and accuracy to determine the locations, sizes, orientations, and shapes. As the service time of the nuclear power plants is increased, the radiation level from the components is getting higher. In order to get more quantitative and reliable results and secure the inspector from the exposure to high radiation level, automation of the ultrasonic equipments has been one of the important research and development(R & D) subject. In this research, it was attempted to visualize the shape of flaws presented inside the specimen using a Modified C-Scan technique. In order to develope Modified C-Scan technique, an automatic ultrasonic scanner and a module to control the scanner were designed and fabricated. IBM-PC/XT was interfaced to the module to control the scanner. Analog signals from the SONIC MARK II were digitized by Analog-Digital Converter(ADC 0800) for Modified C-Scan display. A computer program has been developed and has capability of automatic data acquisition and processing from the digital data, which consist of maximum amplitudes in each gate range and locations. The data from Modified C-Scan results was compared with shape from artificial defects using the developed system. Focal length of focused transducer was measured. The automatic ultrasonic equipment developed through this study is essential for more accurate, reliable, and repeatable ultrasonic experiments. If the scanner are modified to meet to appropriate purposes, it can be applied to automation of ultrasonic examination of nuclear power plants and helpful to the research on ultrasonic characterization of the materials.

  • PDF

The Effects of Surface Energy and Roughness on Adhesion Force (표면에너지와 거칠기가 응착력에 미치는 영향)

  • Rha, Jong-Joo;Kwon, Sik-Cheol;Jeong, Yong-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.11 s.254
    • /
    • pp.1335-1347
    • /
    • 2006
  • Surface energies calculated from measured contact angles between several solutions and test samples, such as Si wafer, $Al_2O_3$, $SiO_2$, PTFE(Polytertrafluoroethylene), and DLC(Diamond Like Carbon) films, based on geometric mean method and Lewis acid base method. In order to relate roughness to adhesion force, surface roughness of test samples were scanned large area and small by AFM(Atomic Force Microscopy). Roughness was representative of test samples in large scan area and comparable with AFM tip radius in small scan area. Adhesion forces between AFM tip and test samples were matched well with order of roughness rather then surface energy. When AFM tips having different radius were used to measure adhesion force on DLCI film, sharper AFM tip was, smaller adhesion force was measured. Therefore contact area was more important factor to determine adhesion force.