• Title/Summary/Keyword: Scan method

Search Result 1,528, Processing Time 0.032 seconds

A study on the Interpolation method of Digital scan image (디지털 스캔 이미지의 보간방법에 관한 연구)

  • 이성형;조가람;구철희
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.16 no.3
    • /
    • pp.81-95
    • /
    • 1998
  • If a image doesn't include sufficient data of output size and resolution, we will scan again the image. Interpolation generates a new pixel by methematical average of processing. In the interpolation method, there are nearest neighbor interpolation, bilinear interpolation and bicubic interpolation etc. This study was carried out for the purpose of researching compatible method to digital scan image caused by only different interpolation methods. Nearest neighbor interpolation show superior effect in the drawing image. Bilinear interpolation show reduction in detail and contrast. Bicubic interpolation show superior effect in the digital photo image USM(Unsharp Mask) application after extension by interpolation show better than extension by interpolation after USM(unsharp mask) application.

  • PDF

Evaluation of Mechanical Properties of Structural Ceramics ($Al_{2}O_{3}$) Using the High Frequency Ultrasonic C - Scan (초음파 C-Scan을 이용한 구조용 세라믹스의 기계적 특성평가)

  • Chang, Y.K.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.9 no.2
    • /
    • pp.18-24
    • /
    • 1989
  • Computer-aided high frequency ultrasonic is applied to aluminum oxide(85w%, 94w%, 96w%, and 99w%) MOR(modulus of rupture) samples to evaluate mechanical properties such as density variation, pore content, elastic modulus, shear modulus, and poisson's ratio. Ultrasonic wave velocity and attenuation measurement techniques were used as an evaluator of such properties. Pulse-echo C-Scan images with different fate setting method using 50MHz center frequency 1 inch focal length transducer allows evaluation of density variation and pore content. Elastic modulus calculated with the relation of density and ultrasonic velocity. It shows good reliability as compared with resonance method. Sintered density variation of $0.025g/cm^{3}$, that is 0.6% of theoretical density in $Al_{2}O_{3}$ samples can be observed by ultrasonic velocity measurement. Attenuation measurement method qualitatively agree with 4-point fracture testing result concerning of porosity content.

  • PDF

A study on the recognition to road traffic sign and traffic signal for autonomous navigation (자율주행을 위한 교통신호 인식에 관한 연구)

  • 고현민;이호순;노도환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1375-1378
    • /
    • 1997
  • In this paper, we presents the algorithm which is to recognize the traffic sign on the road the traffic signal in a video image for autonomous navigation. First, the rocognition of traffic sign on the road can be detected using boundary point estimation form some scan-lines within the lane deducted. For this algorithm, index matrix method is used to detemine what sign is. Then, the traffic signal recognition is performed by usign the window minified by several scan-lines which position may be expected. For this algoritm, line profile concept is adopted.

  • PDF

Enhancement of Image Contrast in Linacgram through Image Processing (전산처리를 통한 Linacgram의 화질개선)

  • Suh, Hyun-Suk;Shin, Hyun-Kyo;Lee, Re-Na
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.345-354
    • /
    • 2000
  • Purpose : Conventional radiation therapy Portal images gives low contrast images. The purpose of this study was to enhance image contrast of a linacgram by developing a low-cost image processing method. Materials and Methods : Chest linacgram was obtained by irradiating humanoid Phantom and scanned using Diagnostic-Pro scanner for image processing. Several types of scan method were used in scanning. These include optical density scan, histogram equalized scan, linear histogram based scan, linear histogram independent scan, linear optical density scan, logarithmic scan, and power square root scan. The histogram distribution of the scanned images were plotted and the ranges of the gray scale were compared among various scan types. The scanned images were then transformed to the gray window by pallette fitting method and the contrast of the reprocessed portal images were evaluated for image improvement. Portal images of patients were also taken at various anatomic sites and the images were processed by Gray Scale Expansion (GSE) method. The patient images were analyzed to examine the feasibility of using the GSE technique in clinic. Results :The histogram distribution showed that minimum and maximum gray scale ranges of 3192 and 21940 were obtained when the image was scanned using logarithmic method and square root method, respectively. Out of 256 gray scale, only 7 to 30$\%$ of the steps were used. After expanding the gray scale to full range, contrast of the portal images were improved. Experiment peformed with patient image showed that improved identification of organs were achieved by GSE in portal images of knee joint, head and neck, lung, and pelvis. Conclusion :Phantom study demonstrated that the GSE technique improved image contrast of a linacgram. This indicates that the decrease in image quality resulting from the dual exposure, could be improved by expanding the gray scale. As a result, the improved technique will make it possible to compare the digitally reconstructed radiographs (DRR) and simulation image for evaluating the patient positioning error.

  • PDF

Searching Methods of Corresponding Points Robust to Rotational Error for LRF-based Scan-matching (LRF 기반의 스캔매칭을 위한 회전오차에 강인한 대응점 탐색 기법)

  • Jang, Eunseok;Cho, Hyunhak;Kim, Eun Kyeong;Kim, Sungshin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.6
    • /
    • pp.505-510
    • /
    • 2016
  • This paper presents a searching method of corresponding points robust to rotational error for scan-matching used for SLAM(Simultaneous Localization and Mapping) in mobile robot. A differential driving mechanism is one of the most popular type for mobile robot. For driving curved path, this type controls the velocities of each two wheels independently. This case increases a wheel slip of the mobile robot more than the case of straight path driving. And this is the reason of a drifting problem. To handle this problem and improves the performance of scan-matching, this paper proposes a searching method of corresponding points using extraction of a closest point based on rotational radius of the mobile robot. To verify the proposed method, the experiment was conducted using LRF(Laser Range Finder). Then the proposed method is compared with an existing method, which is an existing method based on euclidian closest point. The result of our study reflects that the proposed method can improve the performance of searching corresponding points.

The Change of Total Scan Time in Accordance with the Time of the Decision of Scan Time (스캔 시간의 결정시기에 따른 총 스캔 시간 변화에 관한 연구)

  • Lee, Jong-Hun;Ryu, Jae-Kwang;Chung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.81-85
    • /
    • 2009
  • Purpose: The examination of nuclear medicine observes the change in accordance with the time elapsed in the same region purposed and there are many examinations to acquire the image during the same term. At this time, the same parameter should be applied. The hepatobiliary scan, lung scan etc, are the acquired examination in the divided time with a regular term. Pre-set time that is applied in continued next image is set in order to acquire the fixed counts. The same scan time should be applied for each image. This study will look for the rational plan and analyze the change of scan time in accordance with the time of the decision of scan time at examination that pre-set time is applied. Methods: The hapatobiliary scan that use the radio pharmaceutical $^{99m}Tc$-mebrofenin is choosed as compensation from Jan. 2009 to Mar. 2009 in the department of nuclear medicine in ASAN MEDICAL CENTER. Scan is started after 5 minutes from when 222 MBq (6 mCi) is injected to patient. We let patient stand up between both detectors, and possibly close to the front of detector. When scan time reach 10%, 25%, 50%, 75% of total scan time, we measured the expected total scan time. After finishing all of scan, we compared the total scan time and the expected total scan time, while image is acquiring. and we observed the change of scan time in accordance with radio activity by using phantom. Results: After starting scan, a difference of when scan time reach 10%, 25%, 50%, 75% of total scan time is that the biggest difference is 5 seconds on 10%. There statistically is difference between 25% (t:2.88, p<0.01) and 50% (t:2.05, p<0.01). Conclusions: When the same the scan time is applied in the examination that acquire the many frame, concluding the same scan time has a important effect on a quantitative analysis. Although method that decide the scan time after finish all of the examinations, there is a few problem to apply practical affairs. This may cause an inaccurate result on the examination that need a quantitative analysis. We think that operator should try to improve it. At least, after reach 50% of total scan time, deciding the total scan time mean that you can minimize error of a quantitative analysis caused by unmatched scan time from a gap of image.

  • PDF

3D Reconstruction of 3D Printed Medical Metal Implants (3D 출력 의료용 금속 임플란트에 대한 3D 복원)

  • Byounghun Ye;Ku-Jin Kim
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.12 no.5
    • /
    • pp.229-236
    • /
    • 2023
  • Since 3D printed medical implant parts usually have surface defects, it is necessary to inspect the surface after manufacturing. In order to automate the surface inspection, it is effective to 3D scan the implant and reconstruct it as a scan model such as a point cloud. When constructing a scan model, the characteristics of the shape and material of the implant must be considered because it has characteristics different from those of general 3D printed parts. In this paper, we present a method to reconstruct the 3D scan model of a 3D printed metal bone-plate that is one kind of medical implant parts. Multiple partial scan data are produced by multi-view 3D scan, and then, we reconstruct a scan model by alignment and merging of partial data. We also present the process of the scan model reconstruction through experiments.

Method of 3D Body Surface Segmentation and 2D Pattern Development Using Triangle Simplification and Triangle Patch Arrangement (Triangle Simplification에 의한 3D 인체형상분할과 삼각조합방법에 의한 2D 패턴구성)

  • Jeong, Yeon-Hee;Hong, Kyung-Hi;Kim, See-Jo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.9_10 s.146
    • /
    • pp.1359-1368
    • /
    • 2005
  • When we develop the tight-fit 2D pattern from the 3D scan data, segmentation of the 3D scan data into several parts is necessary to make a curved surface into a flat plane. In this study, Garland's method of triangle simplification was adopted to reduce the number of data point without distorting the original shape. The Runge-Kutta method was applied to make triangular patch from the 3D surface in a 2D plane. We also explored the detailed arrangement method of small 2D patches to make a tight-fit pattern for a male body. As results, minimum triangle numbers in the simplification process and efficient arrangement methods of many pieces were suggested for the optimal 2D pattern development. Among four arrangement methods, a block method is faster and easier when dealing with the triangle patches of male's upper body. Anchoring neighboring vertices of blocks to make 2D pattern was observed to be a reasonable arrangement method to get even distribution of stress in a 2D plane.

Development of Men Slacks Pattern Using 3D Scan Data (3차원 인체형상 스캔데이터를 이용한 남자 바지패턴 설계)

  • Sohn, Boo-Hyun
    • Journal of the Korean Home Economics Association
    • /
    • v.46 no.9
    • /
    • pp.137-146
    • /
    • 2008
  • This study was conducted in order to spread out lower body 3D scan data of men in their twenties. The aim was to achieve slacks pattern with ease allowance through comparison with existing flat patterns. For conversion of 3D scan data into 20 pattern, reference lines were established by using Rapid Foam in 3D shape analysis software. 2C-AN program and Yuka CAD were used to convert 20 pattern earned with straight posture of 3D scan data into slacks pattern by using Triangle Simplification & Runge-Kutta Method. In order to achieve this we needed to set a line 9cm below the hip line, to array vertex of each block to crease line while maintaining the horizontal line. And then we needed to set ease allowance in back crotch and to set waist circumference or hip circumference ease allowance in side seam of slacks. Results showed that long front crotch length can be achieved if 3D scan data is compared with 20 existing flat pattern. Slacks pattern that raise front crotch by about 1.5cm compared to back crotch and also possess ease allowance in back crotch area are great in appearance evaluation.

Nonlinear refractive index measurement for amorphous $As_2S_3$ thin film by Z-scan method (Z-scan 방법에 의한 비정질 $As_2S_3$ 박막의 비선형 굴절률 측정)

  • 김성규;이영락;곽종훈;최옥식;이윤우;송재봉;서호형;이일항
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.5
    • /
    • pp.342-347
    • /
    • 1998
  • We present a theoretical analysis of Gaussian beam propagation in nonlinear Kerr media by using aberration-free approximation and Huygens-Fresnel diffraction integral and obtain a simple analytic formular for Z-scan characteristics. Z-scan experiments are carried out on amorphous $As_2S_3$ thin film and compared with the theory developed, showing good agreement. The sign and the value of ${\gamma}$ have been measured at 633 nm to be $+8.65{\times}10^{-6}\textrm{cm}^2/W$. We also measured the far-field intensity profiles, which confirm again self-focusing effect.

  • PDF