• Title/Summary/Keyword: Scan data

Search Result 1,230, Processing Time 0.042 seconds

A COMPARISON OF THE SHAPING ABILITY OF FOUR ROTARY NICKEL-TITANIUM FILES IN SIMULATED ROOT CANALS (엔진구동형 NiTi 파일의 근관성형효과 비교)

  • Kim, Bo-Hye;Choi, Kyoung-Kyu;Park, Sang-Hyuk;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.88-95
    • /
    • 2010
  • The purpose of this study was to compare the root canal shaping ability of 4 rotary NiTi instruments in simulated root canals. For the preparation of thirty two curved root canals, Mtwo instruments using "single length"technique, and Profile, ProTaper Universal, and K3 using crown-down technique (N = 8) were used. All canal samples were prepared by reaching an apical canal size of #30. Pre- and post-instrumentation digital images were recorded and an assessment of canal shape was determined using a computer image analysis program SigmaScan Pro (Systat Software Inc., San Jose, CA, USA). The changes of the dimension of inner walls of canals, (2) the changes of the dimension of outer walls of canals, and (3) the centering ratio were measured at 7 measuring points, and then data were statistically analyzed using one-way ANOVA and Duncan's test. The results were as below; 1. The root canal shaping ability of Profile was significantly faster than that of other rotary NiTi instruments (p < 0.05). 2. The deformation and fracture of all instruments used for this study were not experienced. 3. In the degree of changes of the dimension of inner walls of canals, Profile demonstrated the lowest changes of the dimension of inner walls of canals except at the measuring points of the 1 and 2 mm (p < 0.05). However, the ProTaper Universal showed the highest changes of the dimension of inner walls of canals at all measuring points (p < 0.05). 4. In the degree of changes of the dimension of outer walls of canals, Mtwo demonstrated the lowest changse of the dimension of outer walls of canals except at the measuring point of the 1 mm (p < 0.05). However, Profile exhibited the highest changes of the dimension of outer walls of canals at the measuring points of 3 and 4 mm and ProTaper Universal and K3 showed the largest changes of the dimension of outer walls of canals at the measuring points of 1, 2, 6, and 7 mm (p < 0.05). 5. In degree of centering ratio, Profile demonstrated the least centering ratio comparing with the centering ratio shown by other NiTi instruments at the measuring points of 1, 4, 5, and 6 mm. Results suggest that in the coronal part of canal preparation, active cutting files such as ProTaper Universal may efficiently flare the canal orifice and form a better taper, and in the apical part of the canal, files which have a better centering ability such as Profile may maintain the original canal curvature and reduce the shaping time.

Biodistribution of $^{99m}Tc$-Lactosylated Serum Albumin in Mice with Diethylnitrosamine or Thiacetamide Induced Liver Injury (Diethylnitrosamine 및 Thioacetamide 유발 간손상 생쥐에서의 $^{99m}Tc$-Lactosylated Serum Albumin의 체내 분포상)

  • Whang, Jae-Seok;Ahn, Byeong-Cheol;Sung, Young-Ok;Seo, Ji-Hyoung;Bae, Jin-Ho;Jeong, Shin-Young;Yoo, Jung-Soo;Jeong, Jae-Min;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.200-208
    • /
    • 2005
  • Purpose: Tc-99m labeled diethylenetriaminepentaacctic acid (DTPA)-coupled galactosylated human serum albumin (GSA) is a currently used imaging agent for asialoglycoprotein receptor (ASGPR) of the liver, but, it has several shortcomings. Recently a new ASGPR imaging agent, $^{99m}Tc$-lactosylated human serum albumin (LSA), with simple labeling procedure, high labeling efficiency, high stability was developed. In order to assess the feasibility of the $^{99m}Tc$-LSA as a ASGPR imaging radiopharmaceuticals, we performed biodistribution study of the tracer in liver injured mice model and the results were compared with histolgic data. Materals and Methods: To induce hepatic damage in ICR mice, diethylnitrosamine (DEN) ($60mg/kg/week{\times}5time$, low dose or $180mg/kg/week{\times}2times$, high dose) and thioacetamide (TAA) ($50mg/kg{\times}1time$) were administrated intraperitoneally. Degree of liver damage was evaluated by tissue hematoxilin-eosin stain, and expression of asialoglycoprotein receptor (ASGPR) was assessed by immunohistochemistry using ASGPR antibody. $^{99m}Tc$-LSA was intravenously administrated via tail vein in DEN or TAA treated mice, and biodistribution study of the tracer was also performed. Results: DEN treated mice showed ballooning of hepatocyte and inflammatory cell infiltration in low dose group and severe hapatocyte necrosis in high dose group, and low dose group showed higher ASGPR staining than control mice in immunohistochemical staining. TAA treated mice showed severe hepatic necrosis. $^{99m}Tc$-LSA Biodistribution study showed that mice with hepatic necrosis induced by high dose DEN or TAA revealed higher blood activity and lower liver activity than control mice, due to slow clearance of the tracer by the liver. The degree of liver uptake was inversely correlated with the degree of histologic liver damage. But low dose DEN treated mice with mild hepatic injury showed normal blood clearance and hepatic activity, partly due to overexpression of ASGPR in mice with mild degree hepatic injury. Conclusion: Liver uptake of $^{99m}Tc$-LSA was inversely correlated with degree of histologic hepatic injury in DEN and TAA treated mice. These results support that $^{99m}Tc$-LSA can be used to evaluate the liver status in liver disease patients.

A Comparative Analysis According to a Presence or Absence of Metal Artifacts when a Dose Change and QAC Technique are Applied in PET/CT Tests (PET/CT 검사에서 선량변화와 QAC기법 적용 시 Metal Artifact 유무에 따른 SUV 비교분석)

  • Yun, Sun-Hee;Kim, Yang-Jung;Kang, Young-Jik;Park, Su-Young;Kim, Ho-Sin;Ryu, Hyoung-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.51-56
    • /
    • 2015
  • Purpose As medical radiation exposures on patients are being social issues an interest in a relief of radiation exposures on patients is increasing. Further, there are many cases where some patients among who are getting PET/CT tests choose to get implanted with metal artifacts in their bodies. This study is to find out effects of presence or absence of metal artifacts when dose change or CT attenuation correction for the relief of radiation exposures are applied using phantoms through changes in standard uptake value (SUV). Materials and Methods GE company's Discovery 710 machine was used for PET/CT test equipments. We used NEMA IEC body phantoms. We also used screw and mesh cage made of titanium which are used in real clinical processes for the metal artifacts. Two experiments were conducted: One is to test and measure repeatedly about SUV about differences in CT attenuation corrections according to dose changes and another is to do the same procedure for SUV about the presence and absence of the metal artifacts. We injected $^{18}F-FDG$ into NEMA IEC body phantoms with a TBR ratio of 4:1 and then put the metal material into the transformation phantoms. Once a scanning for the metal artifacts was done we eliminated the metal artifacts and went on non-metal artifacts. For the each two experiments, we scanned repeatedly with CT kVp (140, 120, 100, 80) and mA (120, 80, 40, 20, 10) for an experimental condition. For PET, we reconstructed each with standard AC (STD) technique and quantitation achieved cnsistently QAC) technique among CT attenuation correction methods. We conducted a comparative analysis on measured average values and variations which were measured through repeated measure of SUV of region 1, 2, 3 spheres for each conditions of non-metal /metal scan. Results For each kVp, 120, 80, 40 (mA) of non/metal (screw, mesh cage) showed low frequency of fluctuation rates of above 2%. In 20, 10 mA above 2% of fluctuation rates appeared in high frequency. Also, when we compared the fluctuation rates of STD and QAC techniques in non/metal (screw, mesh cage) tests QAC technique showed about 1-10% of differences for each conditions compared to STD technique. In addition, metal types did not have significant effects on fluctuation rates. Conclusion We confirmed that SUV fluctuation rates for both STD and QAC techniques increase as dosage is lower. We also found that the SUV of PET data was maintained steadily in a low dosage for QAC technique when compared with STD technique. Hence, when the low dosage is used for the relief of radiation exposures on patients QAC technique may be exploited helpfully and this could be applied in the same way for patients with metal artifacts implanted in their bodies.

  • PDF

Comparative evaluation of marginal and internal fit of metal copings fabricated by various CAD/CAM methods (다양한 CAD/CAM 방식으로 제작한 금속하부구조물 간의 변연 및 내면 적합도 비교 연구)

  • Jeong, Seung-Jin;Cho, Hye-Won;Jung, Ji-Hye;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.211-218
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the accuracy of four different metal copings fabricated by CAD/CAM technology and to evaluate clinical effectiveness. Materials and methods: Composite resin tooth of the maxillary central incisor was prepared for a metal ceramic crown and duplicated metal die was fabricated. Then scan the metal die for 12 times to obtain STL files using a confocal microscopy type oral scanner. Metal copings with a thickness of 0.5 mm and a cement space of $50{\mu}m$ were designed on a CAD program. The Co-Cr metal copings were fabricated by the following four methods: Wax pattern milling & Casting (WM), Resin pattern 3D Printing & casting (RP), Milling & Sintering (MS), Selective laser melting (SLM). Silicone replica technique was used to measure marginal and internal discrepancies. The data was statistically analyzed with One-way analysis of variance and appropriate post hoc test (Scheffe test) (${\alpha}=.05$). Results: Mean marginal discrepancy was significantly smaller in the Group WM ($27.66{\pm}9.85{\mu}m$) and Group MS ($28.88{\pm}10.13{\mu}m$) than in the Group RP ($38.09{\pm}11.14{\mu}m$). Mean cervical discrepancy was significantly smaller in the Group MS than in the Group RP. Mean axial discrepancy was significantly smaller in the Group WM and Group MS then in the Group RP and Group SLM. Mean incisal discrepancies was significantly smaller in the Group RP than in all other groups. Conclusion: The marginal and axial discrepancies of the Co-Cr coping fabricated by the Wax pattern milling and Milling/Sintering method were better than those of the other groups. The marginal, cervical and axial fit of Co-Cr copings in all groups are within a clinically acceptable range.

Truncation Artifact Reduction Using Weighted Normalization Method in Prototype R/F Chest Digital Tomosynthesis (CDT) System (프로토타입 R/F 흉부 디지털 단층영상합성장치 시스템에서 잘림 아티팩트 감소를 위한 가중 정규화 접근법에 대한 연구)

  • Son, Junyoung;Choi, Sunghoon;Lee, Donghoon;Kim, Hee-Joung
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.111-118
    • /
    • 2019
  • Chest digital tomosynthesis has become a practical imaging modality because it can solve the problem of anatomy overlapping in conventional chest radiography. However, because of both limited scan angle and finite-size detector, a portion of chest cannot be represented in some or all of the projection. These bring a discontinuity in intensity across the field of view boundaries in the reconstructed slices, which we refer to as the truncation artifacts. The purpose of this study was to reduce truncation artifacts using a weighted normalization approach and to investigate the performance of this approach for our prototype chest digital tomosynthesis system. The system source-to-image distance was 1100 mm, and the center of rotation of X-ray source was located on 100 mm above the detector surface. After obtaining 41 projection views with ${\pm}20^{\circ}$ degrees, tomosynthesis slices were reconstructed with the filtered back projection algorithm. For quantitative evaluation, peak signal to noise ratio and structure similarity index values were evaluated after reconstructing reference image using simulation, and mean value of specific direction values was evaluated using real data. Simulation results showed that the peak signal to noise ratio and structure similarity index was improved respectively. In the case of the experimental results showed that the effect of artifact in the mean value of specific direction of the reconstructed image was reduced. In conclusion, the weighted normalization method improves the quality of image by reducing truncation artifacts. These results suggested that weighted normalization method could improve the image quality of chest digital tomosynthesis.

Radiotherapy in Small Cell Carcinoma of the Uterine Cervix (자궁경부 소세포암종의 방사선치료)

  • Chung Eun Ji;Lee Yong Hee;Kim Gwi Eon;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.369-377
    • /
    • 1997
  • Purpose : This study was Performed to identify the histopathologic feature by the reevaluation of the Pathologic specimen of the cervical tumors and to evaluate the clinical findings and the treatment results of the patients with small cell carcinoma of the cervix treated by radiotherapy. Materials and Methods : 2890 patients with cervical carcinoma received radiotherapy at the Department of Radiation Oncology. Yonsei Cancer Center, Yonsei University College of Medicine between October 1981 and April 1995. Of the 2890 patients in this data base, sixty were found to have small cell carcinomas $(2.08\%)$. Among them thirty six patients were transferred from other hospitals. the biopsy specimens of those Patients were not available. So we could review the slides of the other twenty four patients who were diagnosed at our hospital. Twenty four patients with small cell carcinoma of the cervix were analyzed retrospectively based on the assessment of H & E staining and other four immunohistochemical stains for neuroendocrine differentiation (neuron specific enolase, chromogranin. synaptophysin and Grimelius stain). And we also evaluate the Patients and tumor characteristics. response to radiation. patterns of failures, 5 year overall and disease free survival rates. Results : Thirteen tumors were neuroendocrine carcinomas(13/24 = $54.2\%$) and eleven tumors were squamous carcinomas, small cell type (11/24 = $47.8\%$) based on the assessment of H & E staining and other four neuroendocrine marker studies. So we classified the Patients two groups as neuroendocrine carcinoma and small cell type of squamous carcinoma, Among the 13 neuroendocrine carcinomas, five were well to moderately differentiated tumors and the other eight were Poorly differentiated or undifferentiated ones. The median age was 54 years old (range 23-79 years). Eight Patients had FIGO stage IB disease, 12 had stage 11, 3 had stage III and one had stage IV disease, Pelvic lymph node metastases were found in five Patients $(20.8\%)$. three of them were diagnosed by surgical histologic examination and the other two were diagnosed by CT scan. There was no difference between two histopathologic groups in terms of patients and tumor characteristics. response to radiation. 5 year overall and disease free survival rates. However the distant metastases rate was higher in neuroendocrine carcinoma Patients (6/13:$46.2\%$) than in small cell type of squamous carcinoma Patients (2/11:$18.2\%$), but there was no statistically significant difference because of the small number of patients (P>0.05). Conclusion : More than half of the small cell carcinoma of the cervix patients were neuroendocrine carcinoma (13/24 : $54.1\%$) by reevaluation of the biopsy specimen of the cervical tumors. The tendency of distant metastases of the neurolndocrine carcinoma was greater than those of the small cell type of squamous carcinoma $(46.2\%\;vs.\;18.2\%)$. But there were no differences in the patients and tumor characteristics and other clinical treatment results in both groups. These data suggest that radical local treatment such as radiotherapy or radical surgery combined with combination systemic cytotoxic chemotherapy might provide these patients with the best chance for cure.

  • PDF

Preliminary Report of the $1998{\sim}1999$ Patterns of Care Study of Radiation Therapy for Esophageal Cancer in Korea (식도암 방사선 치료에 대한 Patterns of Care Study ($1998{\sim}1999$)의 예비적 결과 분석)

  • Hur, Won-Joo;Choi, Young-Min;Lee, Hyung-Sik;Kim, Jeung-Kee;Kim, Il-Han;Lee, Ho-Jun;Lee, Kyu-Chan;Kim, Jung-Soo;Chun, Mi-Son;Kim, Jin-Hee;Ahn, Yong-Chan;Kim, Sang-Gi;Kim, Bo-Kyung
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.79-92
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: For the first time, a nationwide survey in the Republic of Korea was conducted to determine the basic parameters for the treatment of esophageal cancer and to offer a solid cooperative system for the Korean Pattern of Care Study database. $\underline{Materials\;and\;Methods}$: During $1998{\sim}1999$, biopsy-confirmed 246 esophageal cancer patients that received radiotherapy were enrolled from 23 different institutions in South Korea. Random sampling was based on power allocation method. Patient parameters and specific information regarding tumor characteristics and treatment methods were collected and registered through the web based PCS system. The data was analyzed by the use of the Chi-squared test. $\underline{Results}$: The median age of the collected patients was 62 years. The male to female ratio was about 91 to 9 with an absolute male predominance. The performance status ranged from ECOG 0 to 1 in 82.5% of the patients. Diagnostic procedures included an esophagogram (228 patients, 92.7%), endoscopy (226 patients, 91.9%), and a chest CT scan (238 patients, 96.7%). Squamous cell carcinoma was diagnosed in 96.3% of the patients; mid-thoracic esophageal cancer was most prevalent (110 patients, 44.7%) and 135 patients presented with clinical stage III disease. Fifty seven patients received radiotherapy alone and 37 patients received surgery with adjuvant postoperative radiotherapy. Half of the patients (123 patients) received chemotherapy together with RT and 70 patients (56.9%) received it as concurrent chemoradiotherapy. The most frequently used chemotherapeutic agent was a combination of cisplatin and 5-FU. Most patients received radiotherapy either with 6 MV (116 patients, 47.2%) or with 10 MV photons (87 patients, 35.4%). Radiotherapy was delivered through a conventional AP-PA field for 206 patients (83.7%) without using a CT plan and the median delivered dose was 3,600 cGy. The median total dose of postoperative radiotherapy was 5,040 cGy while for the non-operative patients the median total dose was 5,970 cGy. Thirty-four patients received intraluminal brachytherapy with high dose rate Iridium-192. Brachytherapy was delivered with a median dose of 300 cGy in each fraction and was typically delivered $3{\sim}4\;times$. The most frequently encountered complication during the radiotherapy treatment was esophagitis in 155 patients (63.0%). $\underline{Conclusion}$: For the evaluation and treatment of esophageal cancer patients at radiation facilities in Korea, this study will provide guidelines and benchmark data for the solid cooperative systems of the Korean PCS. Although some differences were noted between institutions, there was no major difference in the treatment modalities and RT techniques.

National Survey of Sarcoidosis in Korea (유육종증 전국실태조사)

  • 대한결핵 및 호흡기학회 학술위원회
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.6
    • /
    • pp.453-473
    • /
    • 1992
  • Background: National survey was performed to estimate the incidence of sarcoidosis in Korea. The clinical data of confirmed cases were analysed for the practice of primary care physicians and pulmonary specialists. Methods: The period of study was from January 1991 to December 1992. Data were retrospectively collected by correspondence with physicians in departments of internal medicine, dermatology, ophthalmology and neurology of the hospitals having more than 100 beds using returning postcards. In confirmed and suspicious cases of sardoidosis, case record chart for clinical and laboratory findings were obtained in detail. Results: 1) Postcards were sent to 523 departments in 213 hospitals. Internal medicine composed 41%, dermatology 20%, ophthalmology 20% and neurology 19%. 2) Postcards were returned from 241 departments (replying rates was 48%). 3) There were 113 confirmed cases from 50 departments and 10 cases. The cases were composed from internal medicine (81%), dermatology (13%), ophthalmology (3%) and neurology (3%). 78 confirmed cases were analysed, which were composed from department of internal medicine (92%), dermatology (5%), and neurology (3%). 4) The time span for analysed cases was 1980 to 1992. one case was analysed in 1980 and the number gradually increased to 18 cases in 1991. 5) The majority of patients (84.4%) were in the age group of 20 to 49 years. 6) The ratio of male to female was 1 : 1.5. 7) The most common chief complains were respiratory symptoms, dermatologic symptoms, generalized discomforts, visual changes, arthralgia, abdominal pains, and swallowing difficulties in order. 16% of the patients were asymptomatic. 8) Mean duration between symptom onset and diagnosis was 2 months. 9) The most common symptoms were respiratory, general, dermatologic, ophthalmologic, neurologic and cardiac origin in order. 10) Hemoglobin, hematocrits and platelet were in normal range. 58% of the patients had lymphopenia measuring less than 30% of white cell count. The ratio of CD4 to CD8 lymphocytes was $1.73{\pm}1.16$ with range of 0.43 to 4.62. ESR was elevated in 43% of the cases. 11) Blood chemistry was normal in most cases. Serum angiotensin converting enzyme (S-ACE) was $66.8{\pm}58.6\;U/L$ with the range of 8.79 to 265 U /L. Proteinuria of more than 150 mg was found in 42. 9% of the patients. 12) Serum IgG was elevated in 43.5%, IgA in 45.5%, IgM in 59.1% and IgE in 46.7%. The levels of complement C3 and C4 were in the normal range. Anti-nuclear antibody was detected in 11% of the cases. Kweim test was performed in 3 cases, and in all cases the result was positive. 13) FVC was decreased in 17.3%, FEV1 in 11.5%, FEV1/FVC in 10%, TLC in 15.2%, and DLco in 64.7%. 14) PaO2 was decreased below 90 mmHg in 48.6% and PaCO2 was increased above 45 mmHg in 5.7%. 15) The percentage of macrophages in BAL fluid was $51.4{\pm}19.2%$, lymphocytes $44.4{\pm}21.1%$, and the ratio of CD4 to CD8 lymphocytes was $3.41{\pm}2.07$. 16) There was no difference in laboratory findings between male and female. 17) Hilar enlargement on chest PA was present in 87.9% (bilaterally in 78.8% and unilaterally in 9.1%). 18) According to Siltzbach's classification, stage 0 was 5%, stage 158.3%, stage 228.3%, and stage 38.3%. 19) Hilart enlargement on chest CT was present in 92.6% (bilaterally 76.4% and unilaterally in 16.2%). 20) HRCT was done in 16 cases. The most common findings were nodules, interlobular thickening, focal patchy infiltrations in order. Two cases was normal finding. 21) Other radiologic examinations showed bone change in one case and splenomegaly in two cases. 22) Gallium scan was done in 12 cases. Radioactivity was increased in hilar and mediastinal lymph nodes in 8 cases and in parenchyme in 2 cases. 23) The pathologic diagnosis was commonly performed by transbrochial lung biopsy (TBLB, 47.3%), skin and mediastinal lymph nodes biopsy (34.5%), peripheral lymph nodes biopsy (23.6%), open lung biopsy (18.2%) and bronchial biopsy in order. 24) The most common findings in pathology were non·caseating granuloma (100%), multi-nucleated giant cell (47.3%), hyalinized acellular scar (34.5%), reticulin fibrin network (20%), inclusion body (10.9%), necrosis (9.1%), and lymphangitic distribution of granuloma (1.8%) in order. Conclusion: Clinical, laboratory, radiologic and pathologic findings were summarized. This collected data will assist in finding a test for detection and staging of sarcoidosis in Korea in near future.

  • PDF

Smoking-Induced Dopamine Release Studied with $[^{11}C]Raclopride$ PET ($[^{11}C]Raclopride$ PET을 이용한 흡연에 의한 도파민 유리 영상 연구)

  • Kim, Yu-Kyeong;Cho, Sang-Soo;Lee, Do-Hoon;Ryu, Hye-Jung;Lee, Eun-Ju;Ryu, Chang-Hung;Jeong, In-Soon;Hong, Soo-Kyung;Lee, Jae-Sung;Seo, Hong-Gwan;Jeong, Jae-Min;Lee, Won-Woo;Kim, Sang-Eun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.421-429
    • /
    • 2005
  • Purpose: It has been postulated that dopamine release in the striatum underlies the reinforcing properties of nicotine. Substantial evidence in the animal studies demonstrates that nicotine interacts with dopaminergic neuron and regulates the activation of the dopaminergic system. The aim of this study was to visualize the dopamine release by smoking in human brain using PET scan with $[^{11}C]raclopride$. Materials and Methods: Five male non-smokers or ex-smokers with an abstinence period longer than 1 year (mean age of $24.4{\pm}1.7$ years) were enrolled in this study $[^{11}C]raclopride$, a dopamine D2 receptor radioligand, was administrated with bolus-plus-constant infusion. Dynamic PET was performed during 120 minutes ($3{\times}20s,\;2{\times}60s,\;2{\times}120s,\;1{\times}180s\;and\;22{\times}300s$). following the 50 minute-scanning, subjects smoked a cigarette containing 1 mg of nicotine while in the scanner. Blood samples for the measurement of plasma nicotine level were collected at 0, 5, 10, 15, 20, 25, 30, 45, 60, and 90 minute after smoking. Regions for striatal structures were drawn on the coronal summed PET images guided with co-registered MRI. Binding potential, calculated as (striatal-cerebellar)/cerebellar activity, was measured under equilibrium condition at baseline and smoking session. Results: The mean decrease in binding potential of $[^{11}C]raclopride$ between the baseline and smoking in caudate head, anterior putamen and ventral striatum was 4.7%, 4.0% and 7.8%, respectively. This indicated the striatal dopamine release by smoking. Of these, the reduction in binding potential in the ventral striatum was significantly correlated with the cumulated plasma level of the nicotine (Spearman's rho=0.9, p=0.04). Conclusion: These data demonstrate that in vivo imaging with $[^{11}C]raclopride$ PET could measure nicotine-induced dopamine release in the human brain, which has a significant positive correlation with the amount or nicotine administered bt smoking.

Development of Conformal Radiotherapy with Respiratory Gate Device (호흡주기에 따른 방사선입체조형치료법의 개발)

  • Chu Sung Sil;Cho Kwang Hwan;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.41-52
    • /
    • 2002
  • Purpose : 3D conformal radiotherapy, the optimum dose delivered to the tumor and provided the risk of normal tissue unless marginal miss, was restricted by organ motion. For tumors in the thorax and abdomen, the planning target volume (PTV) is decided including the margin for movement of tumor volumes during treatment due to patients breathing. We designed the respiratory gating radiotherapy device (RGRD) for using during CT simulation, dose planning and beam delivery at identical breathing period conditions. Using RGRD, reducing the treatment margin for organ (thorax or abdomen) motion due to breathing and improve dose distribution for 3D conformal radiotherapy. Materials and Methods : The internal organ motion data for lung cancer patients were obtained by examining the diaphragm in the supine position to find the position dependency. We made a respiratory gating radiotherapy device (RGRD) that is composed of a strip band, drug sensor, micro switch, and a connected on-off switch in a LINAC control box. During same breathing period by RGRD, spiral CT scan, virtual simulation, and 3D dose planing for lung cancer patients were peformed, without an extended PTV margin for free breathing, and then the dose was delivered at the same positions. We calculated effective volumes and normal tissue complication probabilities (NTCP) using dose volume histograms for normal lung, and analyzed changes in doses associated with selected NTCP levels and tumor control probabilities (TCP) at these new dose levels. The effects of 3D conformal radiotherapy by RGRD were evaluated with DVH (Dose Volume Histogram), TCP, NTCP and dose statistics. Results : The average movement of a diaphragm was 1.5 cm in the supine position when patients breathed freely. Depending on the location of the tumor, the magnitude of the PTV margin needs to be extended from 1 cm to 3 cm, which can greatly increase normal tissue irradiation, and hence, results in increase of the normal tissue complications probabiliy. Simple and precise RGRD is very easy to setup on patients and is sensitive to length variation (+2 mm), it also delivers on-off information to patients and the LINAC machine. We evaluated the treatment plans of patients who had received conformal partial organ lung irradiation for the treatment of thorax malignancies. Using RGRD, the PTV margin by free breathing can be reduced about 2 cm for moving organs by breathing. TCP values are almost the same values $(4\~5\%\;increased)$ for lung cancer regardless of increasing the PTV margin to 2.0 cm but NTCP values are rapidly increased $(50\~70\%\;increased)$ for upon extending PTV margins by 2.0 cm. Conclusion : Internal organ motion due to breathing can be reduced effectively using our simple RGRD. This method can be used in clinical treatments to reduce organ motion induced margin, thereby reducing normal tissue irradiation. Using treatment planning software, the dose to normal tissues was analyzed by comparing dose statistics with and without RGRD. Potential benefits of radiotherapy derived from reduction or elimination of planning target volume (PTV) margins associated with patient breathing through the evaluation of the lung cancer patients treated with 3D conformal radiotherapy.