• Title/Summary/Keyword: Scan body

Search Result 574, Processing Time 0.027 seconds

The Relationship Between Asymmetrical Weight Bearing and Bone Mineral Density in Chronic Hemiplegic Limbs

  • Shin, Hwa-Kyung;Kim, Tae-Ho
    • Physical Therapy Korea
    • /
    • v.16 no.4
    • /
    • pp.31-36
    • /
    • 2009
  • Hemiplegia-induced immobilizatoin and reduction of mechanical loading in chronic stroke limbs are common cause of disuse osteoporosis. The purpose of this study was to investigate the effects of asymmetrical weight bearing on the loss of bone mineral in the individual with chronic stroke. Sixteen hemiplegic patients with strokes were evaluated. The measurements of bone mineral density (BMD) were evaluated with the quantitative ultrasound system on the calcaneus region of the paretic and non-paretic side. Plantar pressure was measured using the Mat-Scan system. The paretic side showed significantly smaller values in the T-score of BMD, and peak value of plantar pressure, which included forefoot, midfoot, and hindfoot, than the non-paretic side (p<.05). Results from the pearson correlation analysis showed statistically significant correlation between the BMD difference and the peak-pressure difference of midfoot pressure (p<.05). This finding indicated that BMD loss depended on decrease of body weight born on the paretic leg.

  • PDF

Ultrasonic Phased Array Techniques for Detection of Flaws of Stud Bolts in Nuclear Power Plants

  • Lee, Joon-Hyun;Choi, Sang-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.6
    • /
    • pp.440-446
    • /
    • 2006
  • The reactor vessel body and closure head are fastened with the stud bolt that is one of crucial parts for safety of the reactor vessels in nuclear power plants. It is reported that the stud bolt is often experienced by fatigue cracks initiated at threads. Stud bolts are inspected by the ultrasonic technique during the overhaul periodically for the prevention of failure which leads to radioactive leakage from the nuclear reactor. The conventional ultrasonic inspection for stud bolts was mainly conducted by reflected echo method based on shadow effect. However, in this technique, there were numerous spurious signals reflected from every oblique surfaces of the thread. In this study, ultrasonic phased array technique was applied to investigate detectability of flaws in stud bolts and characteristics of ultrasonic images corresponding to different scanning methods, that is, sector and linear scan. For this purpose, simplified stud bolt specimens with artificial defects of various depths were prepared.

PROTOTYPE ALGORITHM OF RADIOMETRIC CALIBRATION FOR IR CHANNELS ON GOES-12

  • Chang Ki-Ho;Oh Tae-Hyung;Ahn Myung-Hwan
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.691-693
    • /
    • 2005
  • The prototype of the radiometric calibration algorithm, including the correction of scan mirror's angle, has been developed for the stationary meteorological sensor, firstly in Korea. We use this system on GOES-12 to evaluate two coefficients, slope and intercept. The evaluated coefficients show good agreement with the NESDIS's results for the five-case data. The calculated coefficients have been applied to the conversion from the measured counts to the radiance and the converting methods according to the scanning are investigated to enhance the radiometric accuracy.

  • PDF

Successful Treatment of Infantile Fibrosarcoma Spinal Metastasis by Chemotherapy and Stereotactic Hypofractionated Radiotherapy

  • Lo, Cheng-Hsiang;Cheng, Shin-Nan;Lin, Kuen-Tze;Jen, Yee-Min
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.6
    • /
    • pp.528-531
    • /
    • 2013
  • We report a case of infantile fibrosarcoma in an 8-month-old boy manifested as a right-sided lower leg mass. Repeated local recurrence and distant metastasis were noted during the following three-year period. Whole body fluoro-deoxyglucose positron emission tomography scan revealed an asymptomatic metastasis involving the fourth lumbar vertebrae. The patient received chemotherapy (VAC regimen) with Cyberknife$^{(R)}$ stereotactic hypofractionated radiotherapy (26 Gy; 4 fractions). This treatment reduced tumor size by 23% without acute radiation toxicity even after 33 months. This case suggests that combining chemotherapy and this form of radiotherapy may be safe and effective against childhood spinal metastasis.

Lipoma with Extraoral Swelling in the Labial Vestibule: Report of a Case

  • Cho, Ju-Yeon;Nam, Ki-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.4
    • /
    • pp.267-270
    • /
    • 2012
  • Lipoma is the most common benign neoplasm of the body with rare occurrence in the oral cavity. It represents 1~4% of benign neoplasms of the mouth, which affect the buccal mucosa, floor of the mouth, tongue and lips. We report a case of lipoma in the labial vestibule with extraoral swelling, which could easily be misdiagnosed as an odontogenic abscess. Excisional biopsy in this case revealed well-circumscribed masses, surrounded by a thin fibrous capsule and composed of sheets of mature adipocytes, arranged in a "chicken wire" configuration. After a computed tomography scan, excisoinal biopsy was done, and there were no recurrence after 5-month follow-up period.

Octree Generation and Clipping Algorithm using Section Curves for Three Dimensional Cartesian Grid Generation (삼차원 직교 격자 생성을 위한 단면 커브를 이용한 옥트리 생성과 셀 절단 알고리듬)

  • Kim, Dong-Hun;Shin, Ha-Yong;Park, Se-Youn;Yi, Il-Lang;Kwon, Jang-Hyuk;Kwon, Oh-Joon
    • Korean Journal of Computational Design and Engineering
    • /
    • v.13 no.6
    • /
    • pp.450-458
    • /
    • 2008
  • Recently, Cartesian grid approach has been popular to generate grid meshes for complex geometries in CFD (Computational Fluid Dynamics) because it is based on the non-body-fitted technique. This paper presents a method of an octree generation and boundary cell clipping using section curves for fast octree generation and elimination of redundant intersections between boundary cells and triangles from 3D triangular mesh. The proposed octree generation method uses 2D Scan-Converting line algorithm, and the clipping is done by parameterization of vertices from section curves. Experimental results provide octree generation time as well as Cut-cell clipping time of several models. The result shows that the proposed octree generation is fast and has linear relationship between grid generation time and the number of cut-cells.

A 3-D Position Compensation Method of Industrial Robot Using Block Interpolation (블록 보간법을 이용한 산업용 로봇의 3차원 위치 보정기법)

  • Ryu, Hang-Ki;Woo, Kyung-Hang;Choi, Won-Ho;Lee, Jae-Kook
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.3
    • /
    • pp.235-241
    • /
    • 2007
  • This paper proposes a self-calibration method of robots those are used in industrial assembly lines. The proposed method is a position compensation using laser sensor and vision camera. Because the laser sensor is cross type laser sensor which can scan a horizontal and vertical line, it is efficient way to detect a feature of vehicle and winding shape of vehicle's body. For position compensation of 3-Dimensional axis, we applied block interpolation method. For selecting feature point, pattern matching method is used and 3-D position is selected by Euclidean distance mapping between 462 feature values and evaluated feature point. In order to evaluate the proposed algorithm, experiments are performed in real industrial vehicle assembly line. In results, robot's working point can be displayed 3-D points. These points are used to diagnosis error of position and reselecting working point.

Pet Registration and Information Providing System Utilizing QR Code (QR 코드를 이용한 애완동물 등록 및 정보제공 시스템)

  • Shin, Dong-Eun;Heo, Jun-Mu;Son, Yeong-Bin;Kim, Yong-Seok
    • Journal of Industrial Technology
    • /
    • v.34
    • /
    • pp.33-37
    • /
    • 2014
  • The current companion animal registration system is based on implanting microchip into animal body. Thus, the maintenance cost is high, and it may cause dangerous effect on the animal health. Moreover, it is very inconvenient in utilizing the information. This paper presents a pet registration and information providing system based on QR code for low cost and convenience in field application. The owner can simply register pet information on the web server, print the QR code and attach it to the pet. Any person can scan the QR code by smart phone, identify the information, and call the owner directly.

  • PDF

Treatment of Differentiated Thyroid Cancer (분화된 갑상선암의 치료)

  • Shong, Young-Kee
    • 대한핵의학회:학술대회논문집
    • /
    • 2002.05b
    • /
    • pp.77-95
    • /
    • 2002
  • During the last several decades, prognosis of differentiated thvroid cancers improved markedly, mainly due to refinement of surgical techniques and routine use of radioactive iodine. Total or neat-total thyroidectomy is to be performed as the first line of treatment. Routine remnant ablation just after surgery decreases recurrence and increases survival. After then patients are maintained on suppressive dose of thyroid hormone to keep endogenous TSH below normal. Regular follow-up of the patients with serum thyroglobulin measurement and iodine whole body scan after thyroid hormone withdrawal or under recombinant human thyrotropin stimulation select high risk patients with recurrence or metastatic disease and treatment with therapeutic dose of radioactive iodine prolongs survival and sometimes leads cure. Currently recommended diagnostic and therapeutic strategies, present controversies and future directions are discussed.

  • PDF

Fine Needle Aspiration Cytological Findings of Burkitt lymphoma -A Brief Case Report- (버킷 림프종의 세침흡인 세포소견 -짧은 증례 보고-)

  • Jo, Hyang-Jeong;Oh, Jung-Taek;Kim, Gang-Deuk;Kim, Hun-Soo
    • The Korean Journal of Cytopathology
    • /
    • v.18 no.2
    • /
    • pp.175-177
    • /
    • 2007
  • A case of Burkitt lymphoma diagnosed through fine needle aspiration cytology is described, A 66-year-old man presented with lymphadenopathy on the right cervical neck and axillary area. An ultrasonogram and CT scan for the cervical neck showed a multiple variable sized lymphadenopathy with pericapsular invasion and necrotic foci, Fine needle aspiration cytology (FNAC) of the cervical lymph nodes revealed very cellular and necrotic smears consisting of diffusely scattered intermediate monotonous round cells, tingible body macrophages and many mitotic figures. Histological features of the excised lymph nodes showed the classic morphological features of Burkitt lymphoma. Recognition of the characteristic cytological features can suggest the possibility of Burkitt lymphoma.