• Title/Summary/Keyword: Scan body

Search Result 574, Processing Time 0.022 seconds

A Comprehensive Approach to Pattern Drafting for Women with Large Bust Cup Sizes through Advanced 3D Virtual Clothing Systems

  • Kaihui Fang;Seiyoung Park;Dong-Eun Kim
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.48 no.4
    • /
    • pp.632-656
    • /
    • 2024
  • This study presents a pattern drafting method for designing a slim-fit blouse for women in their twenties with a D cup bra size and various bust sizes within the standard body type range using the 3D virtual clothing system. Three participants were scanned using a body scanner, and three similar princess blouse patterns were selected. A total of nine virtual blouses were produced, with three sets made for each participant. In the initial evaluations, Pattern C received the highest score. The second pattern was designed by mending the flaws in Pattern C. However, in the eases of the front and back busts, back width and back waist were still insufficient and sleeve length was short. In the similarity evaluation between virtual and real blouses, the overall appearance was similar. Most of the corrected elements received significantly higher ratings in the third real blouse. However, the ease of the rear bust area was slightly large. In general, when drafting blouse patterns for women with large bust sizes, it is essential to increase the ease in the front bust, reduce the ease in the back bust, enlarge the waist dart, and decrease the armhole depth.

An Elimination of False-Positive I-131 Sites in Esophagus for Thyroid Carcinoma; Using Water with Vitamin C Dissolved (갑상선암의 방사성옥소 치료 후 전신 스캔에서 비타민C 용액을 이용한 식도의 위양성 병소 제거에 대한 고찰)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sa-Ron;Cho, Seok-Won;Choi, Young-Sook;Cho, Arther;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.49-56
    • /
    • 2008
  • Purpose: Whole body imaging with radioiodine can detect functioning metastases. Non-physiologic I-131 uptake detected on images usually is interpreted as suggesting functioning thyroid metastases. However, extra-thyroidal I-131 accumulation does not always imply thyroid cancer metastases and has been reported in many circumstances. In order to avoid unnecessary therapeutic interventions it is important to distinguish false-positive sites of I-131 localization. We study here to remove false-positive sites around esophagus region on I-131 whole body imaging in patients who were administrated thyroidectomy. Materials and Methods: From April to August in 2007, we had the patients who had visited our department after they received thyroidectomy due to thyroid cancer. They were given I-131, and performed radioiodine body scan after 41 to 50 hours. Patients were whole-body-scanned for the speed of 8 cm per minute. After that, we took anterior and posterior static images around the patients' neck measured by 300 thousand counts per image. We selected 44 patients who had hot spots around neck region, we divided the patients into two groups. One group was given 0.5 L of water and the other group was given 0.5 L of water with 1 g of Vitamin C dissolved. The patients were asked to drink the fluid for one minute in sitting position and after that, we measured 300 kilo counts per image again. We compared prior anterior, posterior static images with anterior, posterior images after the patients had water or water that Vitamin C resolved. Results: In using water, both observer 1 and 2 interpreted 6 patients were washed out. In the water with Vitamin C resolved, observer 1 and 2 interpreted 9 and 8 patients were washed out. Observer 1 and 2 interpreted 6 and 5 patients had 'indeterminate' when they used water. Both observer 1 and 2 interpreted 6 patients had 'indeterminate' when they used water with Vitamin C resolved. When they used water, observer 1 interpreted 10 patients had 'unchanged' and observer 2 interpreted 11 patients had 'unchanged'. Differently, when they used water with vitamin C resolved, observer1 had 8 patients having 'unchanged'and observer 2 had 9. Conclusion: As a result, by making patients drink 0.5 liter of water which has vitamin C resolved helped getting rid of false-positive sites in esophagus. Therefore, based on this study, we believe that drinking water with vitamin C dissolved is very in terms of reducing false-positive hot spot around the esophagus for the iodine-131 whole body scan.

  • PDF

Evaluation of the Usefulness of Virtual Reality Equipment for Relieving Patients' Anxiety during Whole-Body Bone Scan (전신 뼈 검사 환자의 불안감 해소를 위한 가상현실 장비의 유용성 평가)

  • Kim, Hae-Rin;Kim, Jung-Yul;Lee, Seung-Jae;Baek, Song-Ee;Kim, Jin-Gu;Kim, Ga-Yoon;Nam-Koong, Hyuk;Kang, Chun-Goo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.1
    • /
    • pp.27-32
    • /
    • 2022
  • Purpose When performing a whole-body bone scan, many patients are experiencing psychological difficulties due to the close distance to the detector. Recently, in the medical field, there is a report that using virtual reality (VR) equipment can give pain relief to pediatric patients with weak concentration or patients receiving severe treatment through a distraction method. Therefore, in this paper, VR equipment was used to provide psychological stability to patients during nuclear medicine tests, and it is intended to evaluate whether it can be used in clinical practice. Materials and Methods As VR equipment, ALLIP Z6 VR (ALLIP, Korea) was used and the experiment was conducted after connecting to a mobile phone. The subjects were 30 patients who underwent whole-body bone examination from September 1, 2021 to September 30, 2021. After intravenous injection of 99mTc-HDP, 3 to 6 hours later, VR equipment was put on and whole body images were obtained. After the test, a survey was conducted, and a Likert scale of 5 points was used for psychological anxiety and satisfaction with VR equipment. Hypothesis verification and reliability of the survey were analyzed using SPSS Statistics 25 (IBM, Corp., Armonk, NY, USA). Results Anxiety about the existing whole-body bone test was 3.03±1.53, whereas that of anxiety after wearing VR equipment was 2.0±1.21, indicating that anxiety decreased to 34%. When regression analysis of the effect of the patient's concentration on VR equipment on anxiety about the test, the B value was 0.750 (P<0.01) and the t value was 6.181 (P<0.01). decreased and showed an influence of 75%. In addition, overall satisfaction with VR equipment was 3.76±1.28, and the intention to reuse was 66%. The Cronbach α value of the reliability coefficient of the questionnaire was 0.901. Conclusion When using VR equipment, patients' attention was dispersed, anxiety was reduced, and psychological stability was found. In the future, as VR equipment technology develops, it is thought that if the equipment can be miniaturized and the resolution of VR content images is increased, it can be used in various clinical settings if it provides more realistic stability to the patient.

Clinical Usefulness of PET-MRI in Lymph Node Metastasis Evaluation of Head and Neck Cancer (두경부암 림프절 전이 평가에서 PET-MRI의 임상적 유용성)

  • Kim, Jung-Soo;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.26-32
    • /
    • 2014
  • Purpose: As PET-MRI which has excellent soft tissue contrast is developed as integration system, many researches about clinical application are being conducted by comparing with existing display equipments. Because PET-MRI is actively used for head and neck cancer diagnosis in our hospital, lymph node metastasis before the patient's surgery was diagnosed and clinical usefulness of head and neck cancer PET-MRI scan was evaluated using pathological opinions and idiopathy surrounding tissue metastasis evaluation method. Materials and Methods: Targeting 100 head and neck cancer patients in SNUH from January to August in 2013. $^{18}F-FDG$ (5.18 MBq/kg) was intravenous injected and after 60 min of rest, torso (body TIM coil, Vibe-Dixon) and dedication (head-neck TIM coil, UTE, Dotarem injection) scans were conducted using $Bio-graph^{TM}$ mMR 3T (SIEMENS, Munich). Data were reorganized using iterative reconstruction and lymph node metastasis was read with Syngo.Via workstation. Subsequently, pathological observations and diagnosis before-and-after surgery were examined with integrated medical information system (EMR, best-care) in SNUH. Patient's diagnostic information was entered in each category of $2{\times}2$ decision matrix and was classified into true positive (TP), true negative (TN), false positive (FP) and false negative (FN). Based on these classified test results, sensitivity, specificity, accuracy, false negative and false positive rate were calculated. Results: In PET-MRI scan results of head and neck cancer patients, positive and negative cases of lymph node metastasis were 49 and 51 cases respectively and positive and negative lymph node metastasis through before-and-after surgery pathological results were 46 and 54 cases respectively. In both tests, TP which received positive lymph node metastasis were analyzed as 34 cases, FP which received positive lymph node metastasis in PET-MRI scan but received negative lymph node metastasis in pathological test were 4 cases, FN which received negative lymph node metastasis but received positive lymph node metastasis in pathological test was 1 case, and TN which received negative lymph node metastasis in both two tests were 50 cases. Based on these data, sensitivity in PET-MRI scan of head and neck cancer patient was identified to be 97.8%, specificity was 92.5%, accuracy was 95%, FN rate was 2.1% and FP rate was 7.00% respectively. Conclusion: PET-MRI which can apply the acquired functional information using high tissue contrast and various sequences was considered to be useful in determining the weapons before-and-after surgery in head and neck cancer diagnosis or in the evaluation of recurrence and remote detection of metastasis and uncertain idiopathy cervical lymph node metastasis. Additionally, clinical usefulness of PET-MRI through pathological test and integrated diagnosis and follow-up scan was considered to be sufficient as a standard diagnosis scan of head and neck cancer, and additional researches about the development of optimum MR sequence and clinical application are required.

  • PDF

Bodice Pattern Development of the Slim-fit Dress Shirt for Middle-aged Males Using 3D Body Scanning Data (3D Body Scanning Data를 활용한 중년 남성용 슬림 핏(Slim-fit) 드레스 셔츠 바디스 패턴개발연구)

  • Suh, Chuyeon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.1
    • /
    • pp.171-187
    • /
    • 2016
  • The study performed a comparison analysis of market brand patterns for slim-fit dress shirts and analyzed the body surface development figure of men in their 40s using 3D body scan data and developed slim-fit dress shirt patterns suitable for middle-aged men. The sizes of slim-fit dress shirt patterns showed a slight difference depending on brand. The overlap map of slim-fit dress shirt patterns for brands demonstrates how difference of one-dimensional sizes reflect on two-dimensional patterns. This map provides useful information for pattern design and allows and easy recognition of pattern size differences. A try-on system evaluation through 3D-Simulation allows a grasp of the fitness of neckline and size tolerance of under the arms in front, the silhouette of side lines, and overall fitness in front that also allows analysis of the front/back balance of a shirt in side, the size tolerance proportion in front/back, and the fitness of the arm-hole line. Thus, we obtained try-on results that were equivalent to wearing actual clothing. According to the drafting size suggested in the developed final pattern, the total width was 'C/2+5.5cm', and the front was set at 1cm bigger in the size difference of the front and back. The width of the front neck and the back neck was set identically at 'C/12', while the width of the front neck was set to 'C/12+1.5cm'. For the armhole depth, we added 'C/4+2cm', and '0.5cm and 1.5cm' for the width of the front and back to anthropometry. The results of the try-on evaluation through 3D-Simulation indicated that the fitness of the final slim-fit dress shirt pattern was superior to available slim-fit dress shirt patterns on the market and evaluated as superior to the types for middle-aged men.

Dose Measurements using Phantoms for Tube Voltage, Tube Current, Slice Thickness in MDCT (MDCT의 관전압, 관전류, 슬라이스 두께 변화에 따른 팬텀의 선량 분포 측정)

  • Lee, Chang-Lae;Jeon, Seong-Su;Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.139-143
    • /
    • 2007
  • The purpose of this study was to measure and evaluate radiation dose for MDCT parameters. Patient dose for various combination of MDCT parameters were experimentally measured, using MDCT (GE light speed plus 4 slice, USA), model 2026C electrometer (RADICAL 2026C, USA), standard Polymethylmethacrylate (PMMA) head and body CT dosimetry phantoms. In clinical situations, for a typical abdominal scan performed with MDCT at 120 kVp, 180 mAs, 20 mm collimation, and a pitch of 0.75 $CTDI_w,\;CTDI_{vol}$ were measured as 20.2 mGy, 26.9 mGy, respectively. When scan length is assumed as 271.3 mm, DLP and measured effective dose of the abdominal would be calculated as $729.1\;mGy{\cdot}cm$, 10.9 mSv, respectively.

  • PDF

Selection of mAs with Using Table Strap in Computed Tomography Scan (전산화단층촬영 시 환자 고정 밴드를 이용한 선량의 선택)

  • Lee, Young-Hyen;An, Hyeong-Theck
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.63-69
    • /
    • 2011
  • Table strapis patient fixture for securing the patient movements and falls. if it designed to measure the abdominal circumference and used as an indicator of dose selection at CT scan. it will prevent the overexposure of dose without degradation of image quality and efficiently manage dose of each type of body to technician to deal with CT. First, in order to compare the dose used in CT image and qualitative characteristics. reference image is obtained by examining the abdominal phantom in same conditions with the hospital 120 kVp, 200 mAs, D-Dom (Dynamic Dose Of Modulation). SNR, PSNR, RMSE, MAE, CTDIvol of CT images are compared with reference image. for comparing with reference image, the image that Umbilicus level image of Abdomen CT is stored in the PACS were used. For comparison, the top 12 o'clock portion of the air drawn from the same ROI was measured. CTDIvol, mAs, etc. In order to analyze the characteristics of the image, by measuring the length of the umbilicus circumference, pattern of the dose was analyzed. by using the analyzed perimeter and dose information, To be identified visually, fixed band that scale marked were produced. Use them, If the length of circumference of less than 60 cm 100 mAs, Case of 61~80 cm 120 mAs, Case of 80~100 cm 150 mAs, more than 100 cm 200 mAs, dose selection based on the perimeter, the image was applied. by compare analyzed with the Reference Image, image quality was assessed. by compare with existing tests that equally 200 mAs applied, How much was confirmed that the dose reduction. 1. Depending on the Abdominal circumference, the average PSNR(dB) of the image that differently dose applied was 45.794. 2. Comparing with existing test. the dose of scan that adjusted the mAs depending on the circumference was decreased about 40%. SNR and PSNR of the image that obtained by adjusting the standard mAs based on dose modulation were not much different. Therefore, By choosing a low mAs. dose reduction can be obtained. and the dose selection method that measured Abdominal circumference using a fixed band can protect the overexposure and uniformly apply dose of each type of body to technician to deal with CT.

  • PDF

F-18 FDG PET Scan findings in Patients with Pulmonary Involvement in the Hypereosinophilic Syndrome (원발성 과호산구증가 증후군 환자들 중 폐침범을 보이는 환자군의 F-18 FDG PET 소견)

  • Lee, Jae-Hoon;Kim, Tae-Hoon;Yun, Mi-Jin;Hur, Jin;Kim, Tae-Sung;Kim, Sang-Jin;Kim, Hyung-Joong;Pai, Moon-Sun;Ryu, Young-Hoon;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.239-245
    • /
    • 2005
  • Purpose: Hypereosinophilic syndrome (HES) is an infiltrative disease of eosinophils affecting multiple organs including the iung. F-18 2-fluoro-2-deoxyglucose (F-18 FDG) may accumulate at sites of inflammation or injection, making interpretation of whole body PET scan difficult in patients with cancer. This study was to evaluate the PET findings of HES with lung involvement and to find out differential PET features between lung malignancy and HES with lung involvement. Material and Methods: F-18 FDG PET and low dose chest CT scan was performed for screening of lung cancer. light patients who showed ground-glass attenuation (GGA) and consolidation on chest CT scan with peripheral blood eosinophilia werr included in this study. The patients with history of parasite infection, allergy and collagen vascular disease were excluded. CT features and FDG PET findings were meticulously evaluated for the distribution of GGA and consolidation and nodules on CT scan and mean and maximal SUV of abnormalities depicted on F-18 FDG PET scan. In eight patients, follow-up chest CT scan and FDG PET scan were done one or two weeks after initial study. Results: F-18 FDG PET scan identified metabolically active lesions in seven out of eight patients. Maximal SUV was ranged from 2.8 to 10.6 and mean SUV was ranged from 2.2 to 7.2. Remaining one patient had maximal SUV of 1.3. On follow-up FDG PET scan taken on from one to four weeks later showed decreased degree of initially noted FDG uptakes or migration of previously noted abnormal FDG uptakes. Conclusions: Lung involvement in the HES might be identified as abnormal uptake foci on FDG PET scan mimicking lung cancer. Follow-up FDG PET and CT scan for the identification of migration or resolution of abnormalities and decrement of SUV would be of help for the differentiation between lung cancer and HES with lung involvement.

IgG4 Related Disease Misdiagnosed to Carotid Body Tumor (경동맥소체종양으로 오인된 IgG4 연관 질환)

  • Lee, Gun Hyuk;Song, Ji-Sun;Yoon, So Yeon;Cho, Youn Jin;Hong, Hyun Jun
    • Korean Journal of Head & Neck Oncology
    • /
    • v.36 no.2
    • /
    • pp.27-31
    • /
    • 2020
  • Neck mass has various etiologies, including inflammatory, congenital, neoplastic causes. The IgG4-related disease can cause symptoms in the head and neck areas with an inflammatory neck mass. It also shows clinical and pathological findings from inflammation caused by immune reactions, such as lymphocyte and plasma cell infiltration, storiform fibrosis, obliteration phlebitis, and invigorated serum IgG4 levels. The treatment guideline has not been established and still under debate, but systemic glucocorticoid seems to be effective in the most cases. In this brief report, a 48-year-old male patient presented with voice change for 3 weeks. Left side paramedian vocal fold palsy was observed in the flexible laryngoscopy. About 2.5×2.0×1.2cm size, heterogeneously enhanced neck mass with irregular margin encasing left carotid artery was noted on preoperative contrast enhanced neck CT scan, and it was suspicious of left carotid body tumor. The pathology shows IgG4-related disease rather than carotid body tumors. We report this case of IgG4-related disease, which can be misdiagnosed to carotid body tumors.

Development of 2D Patterns for Cycling Pants using 3D Data of Human Movement and Stretch Fabric (동작시 3D 정보를 이용한 2D 패턴 전개 및 신축성 원단의 신장률을 고려한 사이클 팬츠 개발)

  • Jeong, Yeon-Hee;Hong, Kyung-Hi
    • Korean Journal of Human Ecology
    • /
    • v.19 no.3
    • /
    • pp.555-563
    • /
    • 2010
  • With recent advances in 3D scanning technology, three-dimensional (3D) patternmaking is becoming a powerful way to develop garments pattern. This technology is now applicable to the made to measure (MTM) system of both ordinary and tightly fitting garments. Although the pattern of fitted clothing has been developed using 3D human data, it is still interesting to develop cycling pants by considering while-cycling body posture and fabric elasticity. This study adopted the Garland's triangle simplification method in order to simplify data without distorting the original 3D scan. Next, the Runge-Kutta method (2C-AN program) was used to develop a 2D pattern from the triangular pixels in the 3D scanned data. The 3D scanned data of four male, university students aged from 21 to 25, was obtained using Whole body scanner (Model WB4, Cyberware, Inc., USA). Results showed the average error of measurement was $4.58cm^2$ (0.19%) for area and 0~0.61cm for the length between the 3D body scanned data and the 2D developed pattern data. This is an acceptable range of error for garment manufacture. Additionally, the 2D pattern developed, based on the 3D body scanned data, did not need ease for comfort or ease of movement when cycling. This study thus provides insights into how garment patterns may be developed for ergonomic comfort in certain special environments.