• Title/Summary/Keyword: Scan body

Search Result 574, Processing Time 0.024 seconds

Lomustine Plus Hydroxyurea Chemotherapy for Primary Intramedullary Spinal Cord Tumor in a Maltese Dog

  • Song, Joong-Hyun;Yu, Do-Hyeon;Hwang, Tae-Sung;Lee, Hee-Chun;An, Su-Jin;Sur, Jung-Hyang;Kim, Young Joo;Jung, Dong-In
    • Journal of Veterinary Clinics
    • /
    • v.36 no.3
    • /
    • pp.180-183
    • /
    • 2019
  • A 7-year-old, male Maltese dog with a body weight of 2.8 kg was presented with a history of hind limbs ataxia that progressed to tetraparesis over a one-month period. Based on physical and neurological examinations, tetraparesis with concomitant UMN signs, kyphosis and severe neck pain were identified. On MRI scan, we tentatively diagnosed this patient as a primary intramedullary spinal cord tumor. Therapy with lomustine plus hydroxyurea and prednisolone was initiated and the clinical signs rapidly improved. The patient was regularly checked by MRI scan and the range of the mass was gradually reduced to complete remission for 11 months. About 19 months after treatment, the patient showed anemia and hematochezia which suspected as adverse effects of chemotherapy. The condition was getting worse over 2 months and the patient suddenly expired 657 days after initial presentation. On histopathological examination, the spinal cord sample was identified as a neuronal atrophy without evidence of tumor cell.

320-Channel Multi-Frequency Trans-Admittance Scanner(TAS) for Anomaly Detection (도전율 및 유전율이 다른 병소의 검출을 위한 320-채널 다주파수 Trans-Admittance Scanner(TAS))

  • Oh, Tong-In;Lee, Min-Hyoung;Kim, Hee-Jin;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.84-94
    • /
    • 2007
  • In order to collect information on local distribution of conductivity and permittivity underneath a scan probe, we developed a multi-frequency trans-admittance scanner (TAS). Applying a sinusoidal voltage with variable frequency on a chosen distal part of a human body, we measure exit currents from 320 grounded electrodes placed on a chosen surface of the subject. The electrodes are packaged inside a small and light scan probe. The system includes one voltage source and 17 digital ammeters. Front-end of each ammeter is a current-to-voltage converter with virtual grounding of a chosen electrode. The rest of the ammeter is a voltmeter performing digital phase-sensitive demodulation. Using resistor loads, we calibrate the system including the scan probe to compensate frequency-dependent variability of current measurements and also inter-channel variability among multiple. We found that SNR of each ammeter is about 85dB and the minimal measurable current is 5nA. Using saline phantoms with objects made from TX-151, we verified the performance of the lesion estimation algorithm. The error rate of the depth estimation was about 19.7%. For the size estimate, the error rate was about 15.3%. The results suggest improvement in lesion estimation algorithm based on multi-frequency trans-admittance data.

The Availability of Diagnostic and Treatment Planning Computer in 700 Cancer Patients and Magnification Devices for CT (암환자 700예의 진단 및 치료 CT 이용율과 CT 확대장치)

  • Lee, Gui-Won;Park, Joo-Sun;Han, Yong-Moon;Yoon, Sei-Chul;Shinn, Kyung-Sub
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.2 no.1
    • /
    • pp.81-85
    • /
    • 1987
  • It has been evident since 1972 that computed tomography(CT) can play an important role in treatment and managment of the cancer patients as four steps; diagnosis, satging Treatment and follow-up. In this paper, we intended to investigate the availability of CT scan and treatment planning computer in 700 cancer patients who have undergone radiation therapy at the division of radiation therapy, Kangnam St. Mary's Hospital, Catholic Medical College between Mar. 1983 and Dec. 1985. The result were as follow; 1. Of 700 irradiated cancer patients, 342 patients ($48.9\%$) were performed CT scan prior to radiation therapy. 2. The distribution of lesions in 342 patients having CT scans was like this; CNS (83 of 104 patients, $79.8\%$), abdomen (44 of 76 patients, $57.9\%$), pelvis (100 of 188 patients, $53.2\%$) etc. in order. 3. The treatment planning computer were used in 280 cancer patients ($40\%$). 4. Of the 280 cancer patients using treatment planning computer, 167 patients ($59.6\%$) applied diagnostic CT scan and remaining 113 patients ($40.4\%$) were made body contour to be used for radiation therapy planning by the treatment planning computer. Authors also made some magnification devices used for small multiformat CT images to magnify into life size, consisting of overhead projector (3M) I.V. stand and mirror. These enabled us to make less errors in tracing the small-sized CT images during input of the anatomical data into the treatment planning computer.

  • PDF

Analysis of Foot Shape and Size System of Male High School Students Using 3D Scan Data (3D 스캔 데이터를 활용한 남자 고등학생의 발 형태 및 치수체계 분석)

  • Shin, Yu Jin;Park, Soonjee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.1
    • /
    • pp.53-67
    • /
    • 2020
  • The purpose of this study is to analyze the foot shape and size specification of male high school students. 3D modeling programs such as 'Artec Studio', 'CATIA', and 'Auto CAD' measured the 3D scan data of 361 male high school students provided by KATS. Through principal factor analysis, 10 factors were extracted, including foot length, medial-lateral ratio, and foot length ratio. As the result of the cluster and ANOVA with post-hoc test (Duncan method), the differences among types were clarified. Type 1 (24.7%) represented outward medial-lateral ratio (M-L ratio) with the lowest instep, ankle and little deformed first toe. Type 2 (41.8%) was characterized by the shortest, even M-L ratio, thin ankle and heel, the highest instep and ankle. Type 3 (33.5%) showed the longest, inward M-L ratio, thick ankle and heel, and deformed first toe. As the cross-tabulation of foot length and ball circumference, 17.2 percent was not covered by KS standard; in addition, the foot length was longer than the KS standard. The correlation analysis of key dimensions showed that foot length and ball circumference were highly correlated with other items; therefore, regression equations were derived to estimate other foot measurements using these two items as independent variables.

Measurement of Patient Dose from Computed Tomography Using Physical Anthropomorphic Phantom (물리적 팬텀을 이용한 CT 촬영 환자의 피폭 선량 측정 및 평가)

  • Jang, Ki-Won;Lee, Choon-Sik;Kwon, Jung-Wan;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.3
    • /
    • pp.113-119
    • /
    • 2005
  • The computed tomogrpahy(CT) provides a high quality in images of human body but contributes to the relatively high patient dose. The frequency of CT examination is increasing and, therefore, the concerns about the patient dose are also increasing. In this study the experimental determination of patient dose was performed by using a physical anthropomorphic phantom and thermoluminescent dosimeter(TLD). The measurements were done for the both axial and spiral scan mode. As a result the effective doses for each scan mode were 17.78mSv and 10.01 mSv respectively and the fact that the degree of the reduction in the patient dose depends on the pitch scan parameter was confirmed. The measurement methods suggested in this study can be applied for the reassessment of the patient dose when the technique in CT equipment is developed or the protocol for CT scanning is changed.

An Iterative Image Reconstruction Method for the Region-of-Interest CT Assisted from Exterior Projection Data (Exterior 투영데이터를 이용한 Region-of-Interest CT의 반복적 영상재구성 방법)

  • Jin, Seung Oh;Kwon, Oh-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.132-141
    • /
    • 2014
  • In an ordinary CT scan, a large number of projections with full field-of-view (FFOV) are necessary to reconstruct high resolution images. However, excessive x-ray dosage is a great concern in FFOV scan. Region-of-interest (ROI) CT or sparse-view CT is considered to be a solution to reduce x-ray dosage in CT scanning, but it suffers from bright-band artifacts or streak artifacts giving contrast anomaly in the reconstructed image. In this study, we propose an image reconstruction method to eliminate the bright-band artifacts and the streak artifacts simultaneously. In addition to the ROI scan for the interior projection data with relatively high sampling rate in the view direction, we get sparse-view exterior projection data with much lower sampling rate. Then, we reconstruct images by solving a constrained total variation (TV) minimization problem for the interior projection data, which is assisted by the exterior projection data in the compressed sensing (CS) framework. For the interior image reconstruction assisted by the exterior projection data, we implemented the proposed method which enforces dual data fidelity terms and a TV term. The proposed method has effectively suppressed the bright-band artifacts around the ROI boundary and the streak artifacts in the ROI image. We expect the proposed method can be used for low-dose CT scans based on limited x-ray exposure to a small ROI in the human body.

Primary Hepatosplenic B-cell Lymphoma: linitial Diagnosis and Assessment of Therapeutic Response with F-18 FDG PET/CT (원발성 간비장 B세포성 림프종에서 치료전과 치료 후 F-18 FDG PET/CT 소견)

  • Kang, Sung-Min;Lee, Hong-Je;Seo, Ji-Hyoung;Lee, Sang-Woo;Ahn, Byeong-Cheol;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.333-336
    • /
    • 2008
  • A 52-year-old woman with a history of general weakness, fatigue, weight loss, elevated serum levels of liver transaminase enzyme for three months underwent an F-18 FDG PET/CT scan to evaluate a cause of the hepatosplenomegaly found on abdominal ultrasonography. Initial PET/CT revealed markedly enlarged liver and spleen with intense FDG uptake. Otherwise, there were no areas of abnormal FDG uptake in whole body image. Histological evaluation by a hepatic needle biopsy demonstrated diffuse large B cell type lymphoma and final diagnosis for this patient was hepatosplenic B-cell lymphoma. She received five cycles of CHOP chemotherapy, and second PET/CT scan was followed after then. Follow-up PET-CT revealed normal sized liver with disappearance of abnormal FDG uptake. Hepatosplenic B-cell lymphoma is relatively rare and mostly presents as single or multiple nodules.1,2 Diffuse type hepatosplenic lymphoma is extremely rare and poorly recognized entity.3 The diagnosis is very difficult and complicated by the presence of misleading symptoms.4 In this rare hepatosplenic B-cell lymphoma case, F-18 FDG PET/CT scan provided a initial diagnostic clue of hepatosplenic lymphoma and an accurate chemotherapy response.

Discrimination Energy Range Analysis of Contrast Agents and Calcification using by VNC Application of DECT (DECT의 VNC 적용으로 조영제와 석회화의 식별 에너지 영역 분석)

  • Hyeon-Ju Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.179-185
    • /
    • 2024
  • By applying the various energy spectrum imaging functions of DECT, To quantitatively distinguish between contrast agent and calcification, changes in image quality are analyzed by comparing CNR and SNR. We investigated the level of dose reduction during two scans and one VNC scan. As a result, contrast agent and calcification were best distinguished in the 70 keV area, CNR and SNR were excellent, and scan dose was reduced by about 26.5%. Therefore, by applying DECT, meaningful results were obtained that could visually and quantitatively distinguish between the intravascular contrast agent and the shade of calcification. If clinical research is conducted in the future considering the patient's age, gender, and body type, quantitative analysis of calcification will be possible even with intravascular contrast agent flowing in, which will have a significant effect in reducing the patient's scan dose and the burden of multiple scans.

Study of the Efficacy and Safety of "adenophorae radix extract" in the Obese Patients or Overweight (비만 및 과체중 환자에 대한 사삼추출물의 유효성 및 안전성 평가)

  • Kim, Gi-Tae;Go, Heung;Shin, Seon-Mi;Kim, Hyung-Jun
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.25 no.2
    • /
    • pp.131-141
    • /
    • 2012
  • Objectives: The purpose of this study is to evaluate the efficacy and biosafety of Adenophorae Radix(AR) extract in obesity or overweight patient. Methods: This study is double-blind, randomized, placebo-controlled intervention Study. 30 patients with BMI $25{\leq}$ and 30> were allotted into two groups at random. In 0, $6^{th}$, $12^{th}$ week, we had checked body weight, waist line, hip line, body fat and abdominal CT scan. In 0, $12^{th}$ week, we also had checked lipid metabolism and biosafety with blood test. Results: AR treatment had a significant effect on suppressing body wight gain (p<0.01) and BMI index(p<0.01). AR treatment reduced plasma TG level but we couldn't find statistical significance. AR treatment had produced no adverse reactions. Conclusions: This study shows that Adenophorae Radix(AR) extract can reduce the weight, BMI. Adenophorae Radix(AR) extract can be used in obesity or overweight patient.

A Study on the Breast Shape Analysis of Big-breasted Women (볼륨 유방 여성의 흉부체형 분석에 관한 연구)

  • Han, ChoHee;Yi, Kyong-Hwa
    • Journal of Fashion Business
    • /
    • v.22 no.5
    • /
    • pp.32-40
    • /
    • 2018
  • Big breasted women often experience dissatisfaction with ready-made brassieres, that do not account for individual breast types nor provide adequate cup sizes. This study was conducted to provide basic information on common breast shape and measurements of Korean big-breasted women, and to facilitate development of big-breasted women's bras with excellent fit and comfort. The study analyzed direct upper body measurements of 178 women in their 20's whith cup size C or bigger in the 5th, 6th and 7th Size Korea. In addition, 3D body scan data of women with bra size 75 and cup size C were re-collected and their breast types were examined. Average under-bust circumference of big-breasted women was 75 size in brassiere size. The average stature was 159.78 cm and the body weight was 60.33kg, indicating "overweight". Also, it was revealed that common breast types of big-breasted women, were hemispheric and cone types. The study can facilitate better understanding of breast shapes and sizes of standard big-breasted women, and will be useful as reference in selection of subjects in future studies.