• Title/Summary/Keyword: Scan body

Search Result 574, Processing Time 0.026 seconds

Segmental Artery Injury Following Percutaneous Vertebroplasty Using Extrapedicular Approach

  • Heo, Dong-Hwa;Cho, Yong-Jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.2
    • /
    • pp.131-133
    • /
    • 2011
  • We performed a percutaneous vertebroplasty at the compressed L2 vertebral body of a 73-year-old female using a left-sided unilateral extrapedicular approach. She complained severe radiating pain and a tingling sensation in her left leg two hours after the vertebroplasty. Spinal computed tomographic scan showed a large retroperitoneal hematoma, and a subsequent spinal angiography revealed a left L2 segmental artery injury. Bleeding was successfully controlled by endovascular embolization. Recently, extrapedicular approaches have been attempted, allowing for the avoidance of facet and pedicle injury with only a unilateral approach. With this approach, however, the needle punctures the vertebral body directly. Therefore, this procedure carries the potential risk of a spinal segmental artery.

Visualization of Acupoint by Image Overlapping of Skin Current (피부전류량의 화상중첩에 의한 경혈의 시각화)

  • 이용흠;김용진;고수복;정동명
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.563-566
    • /
    • 1999
  • The functional diagnosis instrument should be preceded first to both the accurate selection of exact acupoint and discrimination. so the measuring and stimulating method are improved to SPAC pattern to evaluate impedance existed in the body. As a result, the resistance factor between skin and probe, the dipolization of cell was reduced so that the judgement of acupoint is advanced. After extraction of optimization parameter of SPAC pattern which the high discrimination efficiency and the lowest affection on the human body is controlled by using microprocessor to enhance conviction. The discrimination efficiency was confirmed by meridian visualization system. Also mechanism of probe was improved to increase efficiency of image recognition processing. The image of discriminated acupoint with probe is obtained by using a camera, the location on the tip of probe is recognized and processed. And then these are converted to virtual color by proportional to measuring current level of scan point on skin.

  • PDF

Emerging Trends in 3D Technology Adopted in Apparel Design Research and Product Development (의류학 연구 및 패션산업 현장에 도입되고 있는 3D 기술동향 및 적용사례 고찰)

  • Park, Huiju;Koo, Helen
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.42 no.1
    • /
    • pp.195-209
    • /
    • 2018
  • This study reviewed emerging trends in 3D technology adopted in apparel design research and product development for rapid prototyping and effective evaluation of product performance. Based on a literature review, the authors discussed technical advantages, practical merits and limitations, applications, and on-going developmental efforts of the following methodologies focusing on 3D body scanning and 3D motion capture, and 3D virtual fit simulation technologies. Such data-driven technical approaches observed in recent apparel design research and industry practice are expected to increasingly be adopted in the field to improve consumers' satisfaction with functionality, aesthetics, and comfort of a wide range of apparel products that include daily wear, sport apparel and protective clothing.

Evaluation of Usefulness of Radio-iodine SPECT/CT in Differentiated Thyroid Cancer (분화성갑상선암에서 방사성요오드 SPECT/CT의 유용성 평가)

  • Lee, Jeong-Won;Lee, Ho-Young;Oh, So-Won;Kim, Seok-Ki;Jeong, Ki-Wook;Kim, Seon-Wook;Kang, Keon-Wook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.5
    • /
    • pp.350-358
    • /
    • 2007
  • Purpose: Localizing and differentiating a metastatic lesion of differentiated thyroid cancer (DTC) by using radio iodine whole body scan could be difficult because a whole body scan (WBS) lacks anatomic information. This study was performed to evaluate the usefulness of radio-iodine SPECT/CT for differentiating equivocal lesions. Materials & Methods: Among 253 patients with DTC who had undergone radio-iodine scan between February and July 2006, 26 patients were enrolled (M:F = 8:18, Age $50.7{\pm}12.5$ years) in this study. The patients had abnormal uptakes in the WBSs that necessitated precise anatomical localization for differentiating between a metastatic lesion and a false-positive lesion. SPECT/CT was performed for the region with abnormal uptake in the WBS. WBS and SPECT/CT were evaluated visually. Metastases were diagnosed based on the results of the radio-iodine scan along with the results of other radiological examinations and serological tests. Results: Based on the WBS images, 13 were suspected with cervical lymph node (LN) metastases in 16 patients with abnormal neck uptake, and in the 11 patients with abnormal extra-cervical uptakes, extra-cervical metastases were doubtful in all. After SPECT/CT was performed, the diagnostic results were altered for 16 patients (62%). SPECT/CT revealed that only 5 patients had cervical LN metastases, while 3 patients had extra-cervical (mediastinal) LN metastases. Overall, there was a 58% (15/26) change in diagnoses and plans for treatment due to SPECT/CT. Among 8 patients suspected with metastases on SPECT/CT, 6 patients underwent another radio-iodine therapy. In 96% (24/25) of the patients, the results of SPECT/CT corresponded with those of further radiological examinations and with other clinical information. Conclusion: Radio-iodine SPECT/CT images permitted the differentiation of abnormal radio-iodine uptake and improved anatomical interpretation in DTC.

Effective Dose Evaluation using Clinical PET/CT Acquisition Protocols (전신 PET/CT 영상 획득 프로토콜을 이용한 유효선량 평가)

  • Nam, So-Ra;Son, Hye-Kyung;Lee, Sang-Hoon;Lee, Chang-Lae;Cho, Hyo-Min;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.173-178
    • /
    • 2006
  • The purpose of this study was to evaluate the radiation dose for clinical PET/CT protocols in clinical environments using Alderson phantom and TLDs. Radiation doses were evaluated for both Philips GEMINI 16 slice PET/CT system and GE DSTe 16 slice PET/CT system. Specific organ doses with $^{137}Cs$ transmission scan, high quality CT scan and topogram in philips GEMINI PET/CT system were measured. Specific organ doses with CT scan for attenuation map, CT scan for diagnosis and topogram in GE DSTe PET/CT system were also measured. The organs were selected based on ICRP60 recommendation. The TLDs used for measurements were selected for within an accuracy of ${\pm}5%$ and calibrated in 10 MV X-ray radiation field. The effective doses for $^{137}Cs$ transmission scan, high qualify scan, and topogram in Philips GEMINI PET/CT system were $0.14{\pm}0.950,\;29.49{\pm}1.508\;and\;0.72{\pm}0.032mSv$ respectively. The effective doses for CT scan to make attenuation map, CT scan to diagnose and topogram in GE DSTe PET/CT system were $20.06{\pm}1.003,\;24.83{\pm}0.805\;and\;0.27{\pm}0.008mSv$ respectively. We evaluated the total effective dose by adding effective dose for PET Image. The total PET/CT doses for Philips GEMINI PET/CT (Topogram+$^{137}Cs$ transmission scan+PET, Topogram+high qualify CT+PET) and GE DSTe PET/CT (Topogram +CT for attenuation map+ PET, Topogram+diagnostic CT+ PET) are $7.65{\pm}0.951,\;37.00{\pm}1.508,\;27.12{\pm}1.003\;and\;31.89{\pm}0.805mSv$ respectively. Further study may be needed to be peformed to find optimal PET/CT acquisition protocols for reducing the patient exposure with good image qualify.

  • PDF

Comparison of Diagnostic and Post-therapy Radioiodine Scan in Well-Differentiated Thyroid Cancer and the Clinical Outcome (갑상선암 환자에서 방사성옥소 진단스캔과 치료 후 스캔의 비교 및 임상경과)

  • Lee, Seok-Mo;Bae, Sang-Kyun;Yum, Ha-Yong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.22-29
    • /
    • 2000
  • Purpose: We compared the first postoperative diagnostic and post-therapy scans of patients who received therapeutic doses of I-131, to investigate the difference in clinical outcomes between patients with concordant findings of diagnostic and post-therapy scans and patients with discrepant (more lesions in post-therapy scan) findings. Materials and Methods: The first postoperative diagnostic and post-therapy radioiodine scans of one hundred forty three patients with well differentiated thyroid carcinoma were reviewed. Diagnostic scans were obtained following ingestion of 185 MBq of I-131 and post-therapy scans were obtained after therapeutic dose of $3.7{\sim}9.3$ GBq of I-131. Successful ablation was defined as no radioiodine uptake on diagnostic radioiodine scan and normal range of serum thyroglobulin level (<10 ng/ml) during serum TSH elevation. Results: Discrepant scan findings were noted in 25 (17.5%) patients. Twenty-two patients (15.4%) showed more lesions in post-therapy scan and 3 patients (2.1%) showed stunning effect. Nine (64.3%) of 14 patients with distant metastasis revealed metastatic lesion(s) only on post-therapy scan. Stunning effect was considered as sublethal damage in 1 patient and treatment by a diagnostic dose in 2 patients. Ablation was achieved in 52.4% (75/143) of all patients. Ablation rate and mean cumulative radioiodine dose were not different statistically between concordant and discrepant groups. Conclusion: There were 17.5% difference between diagnostic and post-therapy scan findings when using 185 MBq of I-131 as a diagnostic dose. However, 64.3% of distant metastases were revealed only on post-therapy scan. Ablation rate and mean cumulative radioiodine dose were not different statistically between concordant and discrepant groups. The stunning effect was considered as not only sublethal damage but also treatment by a small diagnostic dose of radioiodine.

  • PDF

Bone Marrow Scintigraphy with Antigranulocyte Antibody in Multiple Myeloma: Comparison with Simple Radiography and Bone Scintigraphy (항과립구 항체 골수스캔을 이용한 다발성 골수종 병변의 평가: 단순골X-선점사 및 골스캔과의 비교)

  • Kim, Dong-Hwan;Lee, Jae-Tae;Baek, Jin-Ho;Jung, Jin-Tae;Hyun, Dong-Woo;Chun, Kyung-Ah;Lee, Young-Hak;Sohn, Sang-Kyun;Song, Hong-Seok;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.354-364
    • /
    • 1998
  • Purpose: Simple X-ray study and bone scan have limitations for early diagnosis of bone or bone marrow lesions in multiple myeloma. The purpose of this study was to evaluate the diagnostic usefulness of bone marrow immunoscintigraphy using anti-granulocyte monoclonal antibody for the evaluation of bone involvement in multiple myeloma. Materials and Methods: In 22 patients (Male: 15, Female: 7) with multiple myeloma, we performed whole-body immunoscintigraphy using $^{99m}Tc$-labelled antigranulocyte antibody (BW 250/183, Scintimum $Granulozyt^{(R)}$ CIS, France) and compared the findings with those of simple bone radiography and $^{99m}Tc$-MDP bone scan. Abnormal findings in bone marrow scintigraphy were, considered to be present in case of expansion of peripheral bone marrow or focal photon defect in axial bones. Results: Marrow expansion was noted in 15 of 22 patients (68%). Focal photon defects were found in 18 patients (82%). While one (33%) of 3 patients with Stage II disease showed focal defects in bone marrow scan, abnormal focal defects were observed in 17 of 19 (90%) patients with Stage III. Among 124 focal abnormal sites which were observed in bone marrow scan, bone scan or simple bone radiography, bone marrow scan detected 92 sites (74%), whereas 82 sites (66%) were observed in simple bone radiography(58 sites, 47%) or bone scan(40 sites, 32%). Fifty-one (41%) out of 124 bone lesions were detected by bone marrow scan only, and located mostly in thoracolumbar spine. Conclusion: Bone marrow scan using $^{99m}Tc$-labelled antigranulocyte antibody seems to be a more sensitive procedure for the detection of pathologic bone lesions than simple bone X-ray or bone scan in patients with multiple myeloma.

  • PDF

Evaluation of 18F-FDG PET/CT Image Distortion by NEMA IEC Body Phantom (NEMA IEC Body Phantom을 이용한 18F-FDG PET/CT 영상의 왜곡 평가)

  • Park, jooncheol;Yang, hanjoon
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.4
    • /
    • pp.427-433
    • /
    • 2013
  • Recently, 18F-FDG PET based CT scan was a critical examination that the after, before plan diagnosis and treatment of tumors. But, due to the distortion of SUV that should be proportional to the metabolic rate of glucose in the tumor, the other measurement methods are being on study. In this study, compared the degree of distortion of SUV that according to the volume of the tumor analysis ROI and VOI using the NEMA IEC Phantom. The results, the SUVmax, mean value are rapidly decreased with threshold value 500 mm2 interval of the ROI analysis, 1500 mm3 interval of the VOI analysis. When compared SUVmax value SUVmean, ROI and VOI analysis VOI measurements was 1.077 times higher SUVmax was 0.981 times highe compared to the value of the ROI measurement. Compare MTV, SUV 2.0 as measured by the volume of the VOI to Volume showed a slightly higher results(Volume / MTV = $93.4 %{\pm}14.8 %$). Considering the above results, Tumor evaluation by 18F-FDG PET / CT scan Consider each threshold value should be analyzed due to larger SUV's Distortion depending on the size of the tumor. VOI analysis is recommended. because it showed the VOI analysis is higher than the ROI analysis SUVmax and lower SUVmean due to VOI analysis than once as a measure of the wider area as measured ROI analysis. MTV (R2 = 0.999), a result close to the actual size of the tumor. but, more research is needed in this regard, because SUV according to the standards of value are affected.

Determination of Adequate Entry Angle of Lumbar Sympathetic Ganglion Block in Korean

  • Kim, Won-Ho;Kim, Sang-Kwon;Lee, Chul-Joong;Kim, Tae-Hyeong;Sim, Woo-Seok
    • The Korean Journal of Pain
    • /
    • v.23 no.1
    • /
    • pp.11-17
    • /
    • 2010
  • Background: The target of lumbar sympathetic ganglion block is the anterolateral surface of the L2, 3 and 4 vertebral bodies, where the lumbar sympathetic ganglion usually lies. In most cases, a block-needle is inserted approximately 5-8 cm lateral to spinous process on the skin and directed to the anterolateral surface of vertebral body obliquely. The purpose of this study is to determine the safe entry angle and entry point in Korean by using the abdominal CT scan images. Methods: The abdominal CT images of eighty five patients were recruited to this study. The minimal angle aimed at the lumbar sympathetic ganglion that can pass through the lateral aspect of body and maximal angle that avoids puncturing the kidney, ureter or retroperitoneal space were measured. The distance from midline to skin entry point was also measured. Results: There was no significant difference in entry angle among L2, 3, and 4 level. The entry angle was similar in the right and left side, and in males and females. The entry angle of old age group was significantly smaller than that of young age group. The calculated safe entry angle was $30.5{\pm}0.4^{\circ}$ and entry point was $7.7{\pm}0.2\;cm$ and $6.7{\pm}0.1\;cm$ lateral from midline in males and females respectively. Conclusions: These measurements can be used as a reference for lumbar sympathetic ganglion block and radiofrequency lesioning. Prior to performing the lumbar sympathetic ganglion block for cancer patients, the abdominal CT scan should be reviewed to prevent complications.

Classification of Torso Shape According to Abdominal Protrusion of Middle-Aged Women (중년 여성 복부 돌출 정도에 따른 토르소 형태 분류)

  • Do, Wolhee;Lee, Jeongeun
    • The Korean Fashion and Textile Research Journal
    • /
    • v.23 no.2
    • /
    • pp.226-236
    • /
    • 2021
  • The purpose of this study was to classify the torso shape based on abdominal protrusion caused by changes in the physical characteristics of middle-aged women. This study analyzed 3D shape data of 401 females ranging in age from 40 to 59 years who participated in the 6th Size Korea project. Based on the Size Korea 3D measurement standard, 27 additional items such as height, protrusion, and angle were measured in the 3D scan data. Nine factors were extracted from the analysis of constituent factors of the torso: "vertical size of torso," "flatness and protrusion of abdomen," "torso front extrusion," "upper body height," "bust size and flatness," "size of belly and angle of lower abdomen," "hip length," "hip flatness," and "horizontal size of bust." As a result of the cluster analysis using these nine factors, the torsos of middle-aged women were classified into three types. Type 1 has upper abdominal deposition with a small and long upper body and an advanced abdomen; type 2 has lower abdominal deposition with a small and short torso and a small belly and hip flexion; and type 3 has central abdominal deposition with a big and long torso, large breasts, and protruding abdo¬men front. The middle-aged women were mostly distributed in Type 2. The above results will be useful as basic data for the development of clothing with improved fit to accommodate the changed physical characteristics of middle-aged women.