• Title/Summary/Keyword: Scan body

Search Result 574, Processing Time 0.027 seconds

A study of making a dress form for women using a 3D printer (3D 프린터를 이용한 여성용 인대 제작 연구)

  • Oh, Seol Young
    • The Research Journal of the Costume Culture
    • /
    • v.24 no.6
    • /
    • pp.725-742
    • /
    • 2016
  • In the Korean fashion industry, 3D printing systems are considered as new technology and a new opportunity. With 3D printers, consumers can be manufacturers and individuals can develop businesses with little upfront capital. In this study, a dress form for the typical Korean women's body shape was developed using 3D technology (3D scanning, 3D modeling, and 3D printing). Ten women with apparel sizes 85-91-160 were selected from 3D body-scan data collected by SizeKorea of 201 women aged 25 to 34 (2010). First, 15 horizontal cross-sections were collected from the 3D scan data of the 10 subjects. Then, inside lines of those cross-sections were drawn at 15-degree intervals, and the lengths were measured. The average of the inside lines was connected to the internal spline curve, and the curves were used as the average cross-sections. The average torso body and the dress form of Korean women were developed into a 3D solid model using a 3D CAD program (Solidworks 2012). An output mockup was printed by the FDM type's 3D printing system (Bonbot 1200, Bonbot 3-H4) using PLA material. The dimensions comparing the 3D solid modeling to the 3D printed mockup of the dress form were measured, and minor differences were between 0.00cm and 0.40cm. In the future, 3D printing systems are expected to be in use for various personalized dress forms.

Using a Body Scanner in Assessing Perceptions of Attractiveness: Cross-Regional Study

  • Aghekyan, Marine;Kim, Dong-Eun;Lichty, Margaret
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.37 no.6
    • /
    • pp.799-808
    • /
    • 2013
  • Previous research reported that body size measured as Body Mass Index (BMI) and body shape measured as waist-hip-ratio (WHR) are two essential factors that form the perceptions of body attractiveness. However, the debate on the importance of BMI versus WHR is ongoing. In addition, scholarly articles, that focus on the role of geographic and cultural variability on perceptions of attractiveness, report inconsistent results. Some suggested that according to globalization and the rise of mass media, geographic variability of perceptions of attractiveness have been altered, while others believed that it remains. This study cross-regionally investigates the role of body size and body shape on the perceptions of female attractiveness. Samples were composed of 107 female college students in Alabama and 107 female college students in California. Participants viewed 27 three-dimensional body scan images of women in three body shapes (pear, hourglass, and rectangle) and three body sizes (underweight, normal weight, and overweight) and rated their perceptions of attractiveness. Images were shown to students in a random order with an overhead projector and Microsoft Office PowerPoint software. A three-way mixed-ANOVA was conducted to analyze the data. The results of the study showed that some regional differences exist between the two sample groups. However, regardless of the regional difference, hourglass shapes were perceived to be the most attractive shape and underweight sizes were perceived to be the most attractive size for both samples.

A Study on Body Shape for 3D Virtual Body Shape Transformation - Focusing on the Women with age of forties - (3차원 가상바디 변형을 위한 체형연구 - 40대 여성을 대상으로 -)

  • Shin, Ju-Young Annie;Nam, Yun-Ja
    • The Korean Fashion and Textile Research Journal
    • /
    • v.17 no.2
    • /
    • pp.265-277
    • /
    • 2015
  • The aim of this study was to successfully reflect human body changes on the transformation of the virtual body within 3D virtual fitting spaces. For this purpose, existing problems of shape transformation of the virtual body were analyzed and regression equations which provides useful basic data for transformation of the virtual body that can be applied usefully to the 3D virtual fitting system was developed. Necessary data for the analyses were body measurement and 3D scan data of women with average physical form between the ages of 40 through 49. The reason that we used human body changes of the female subjects in their forties was based on the recognition that fundamental female body changes start to occur from age of forty. Body shapes were largely divided into 3 groups according to obesity which was found to be the biggest factor of shape change. Seven factors were extracted based on factor analysis of 47 body measurement categories and regression equations were created to extract specific measurements for each BMI group based on these seven factors. The major contribution of this paper can be summarized as follows. First, the regression equations to extract specific measurements based on the 7 representative variables remediated existing problem of virtual bodies as it increased the number of body shape transformation areas. Second, the regression equations helped to overcome the problem of current failing to reflecting changes in body cross-section shape based on simple girth measurements based on analysis of cross-section distances.

Energy Consumption of Taekwondo Practitioners due to a Thigh Muscle Extracted by CT Scan (CT Scan으로 추출한 허벅지 근육량에 따른 태권도 수련자의 에너지 소모량)

  • Kim, Changmo;Ha, Insuk;Lee, SangBock
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.199-204
    • /
    • 2013
  • Despite the suzerain of Korea Taekwondo physical activity and a corresponding lack of basic research on energy consumption and the status of this research is urgent. In this study, the sensor (SenseWear (R) PRO2 Armband), using physical activity were obtained in Taekwondo, and body composition data were obtained by Inbody 520, We were thigh scan using CT scanner and thigh muscle area by CT scan data were acquired. Result of analysis, average thigh muscle area of experimenter 8 people was 132.79 $cm^2$, Of 20 cm above the patella thigh was a 178.79 $cm^2$. Thigh circumference and muscle area showed that the correlation. The average energy consumption per minute was 6.94 calories, and thigh muscle area and average energy consumption per minute also showed that correlation.

Effect of the Bean Sprouts Growth by Scanning Frequency of Diagnostic Ultrasound Probe Type and Mode Change (진단용 초음파 Probe 및 Mode 변화에 따른 초음파 주사빈도가 콩나물 발아 과정에 미치는 영향)

  • Choi, Kwanyong;Lim, Hyun Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.150-154
    • /
    • 2015
  • Long time ultrasound scan can cause a temperature rise in human tissue and affect the physical body. This is closely connected with patients' safety. So many researchers have been studied on this matter with animals such as mammals and experimental rat, because diagnostic ultrasound has been used many types of human organ to find disease. Therefore, this study is tested on bean sprouts to search how far the tissue temperature changes because of the excessive scanning consequence from ultrasound diagnosis and frequent number of ultrasonic scanning and how much affect their growth. The United States and several European countries have restrictions for number of scanning, while South Korea does not have any limitation for using ultrasound diagnosis. Comparison was that how different condition affect its' growing. The testing group is like many pregnancy moms to have 50 minutes in B-mode and color doppler mode by linear, convex and sector probe every day for a week and the other is to scan only once during the testing period. As a result, it was confirmed that there was a significant growing difference on frequent ultrasonic scanning group compared to normal one. So the final conclusion is that there needs to have a significant limitation of ultrasound scan time and a number of inspection when having for diagnostic ultrasound and recommendation like USA and a few European countries.

Colon Cancer Mimicking Physiologic FDG Uptake : with Using of Negative Oral Contrast (네거티브 경구 조영제를 이용한 PET/CT 촬영시 나타난 종양성 섭취와 유사한 생리적 장관 섭취)

  • Jeong, Young-Jin;Kang, Do-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.3
    • /
    • pp.186-187
    • /
    • 2006
  • A 64-year-old female with glioblastoma multiforme (GBM) was assigned to our department for whole body PET/CT scan. She ingested 1 liter of pure water as negative oral contrast just before PET/CT examination. FDG-PET/CT images showed a very intense hypermetabolic, focal lesion in the abdominal cavity around descending colon. The SUVmax of the lesion was 17.2. But there was no abnormal lesion corresponded to the area of PET scan in the combined contrast enhanced CT scan. We suggested considering a malignant lesion due to very intense glycolytic activity. Conventional abdominal CT scan & colonoscopy were accomplished within one week after PET/CT evaluation. There was no abnormality in both examinations. We executed follow-up PET/CT evaluation after 1 month and couldn't find any abnormality around the corresponding area. So we concluded the hypermetabolism was colonic physiologic uptake. A colonic physiologic uptake is a well known cause of false positive finding. Nuclear physicians should be considered the possibility of malignancy when interpret focal colonic uptake, especially incidental finding. There are a few reports that using of negative oral contrast is able to reduce gastrointestinal physiologic uptakes. But as we can see in this case, although we used negative oral contrast, intense physiologic uptake is detected and maxSUV is able to up to 17.2. So, it is important to keep a fact in mind. Even though there is a colonic physiologic uptake in PET/CT image, it may be able to show very intense hypermetabolism regardless of using negative oral contrast.

Estimating Organ Doses from Pediatric Cerebral Computed Tomography Using the WAZA-ARI Web-Based Calculator

  • Etani, Reo;Yoshitake, Takayasu;Kai, Michiaki
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.1
    • /
    • pp.1-7
    • /
    • 2021
  • Background: The use of computed tomography (CT) device has increased in the past few decades in Japan. Dose optimization is strongly required in pediatric CT examinations, since there is concern that an unreasonably excessive medical radiation exposure might increase the risk of brain cancer and leukemia. To accelerate the process of dose optimization, continual assessment of the dose levels in actual hospitals and medical facilities is necessary. This study presents organ dose estimation using pediatric cerebral CT scans in the Kyushu region, Japan in 2012 and the web-based calculator, WAZA-ARI (https://waza-ari.nirs.qst.go.jp). Materials and Methods: We collected actual patient information and CT scan parameters from hospitals and medical facilities with more than 200 beds that perform pediatric CT in the Kyushu region, Japan through a questionnaire survey. To estimate the actual organ dose (brain dose, bone marrow dose, thyroid dose, lens dose), we divided the pediatric population into five age groups (0, 1, 5, 10, 15) based on body size, and inputted CT scan parameters into WAZA-ARI. Results and Discussion: Organ doses for each age group were obtained using WAZA-ARI. The brain dose, thyroid dose, and lens dose were the highest in the Age 0 group among the age groups, and the bone marrow and thyroid doses tended to decrease with increasing age groups. All organ doses showed differences among facilities, and this tendency was remarkable in the young group, especially in the Age 0 group. This study confirmed a difference of more than 10-fold in organ doses depending on the facility and CT scan parameters, even when the same CT device was used in the same age group. Conclusion: This study indicated that organ doses varied widely by age group, and also suggested that CT scan parameters are not optimized for children in some hospitals and medical facilities.

Evaluation on Usefulness of Applying Body-fix to Four Dimensional Radiation Therapy (4차원 방사선 치료시 Body Fix의 유용성 평가)

  • Kim, Young-Jae;Jang, Young-Ill;Ji, Yeon-Sang;Han, Jae-Bok;Choi, Nam-Gil;Jang, Seong-Joo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.10
    • /
    • pp.419-426
    • /
    • 2013
  • This study investigates the usefulness of body fix in 4DRT on Liver cancer trying to find tumor tissue's volume and located variations, absorbed dose on tumor and normal tissues. Test subjects 23 patients were agreed these test. These patient's have a 4 dimensional CT scan. We make an acquisition on patients CT image by two types -put on the body fix or not-. Average tumor volume reduced by 0.17% on GTV and 3.2% on CTV and PTV. Tumor's variation reduces 29.8%(anterior and posterior, AP) and 5.31% (upper and lower, UL). The absorbed tumor doses under put on the body fix was a little higher(1.3%) than other. Normal tissues'(normal liver, stomach, Rt. kidney, spinal cord) absorbed dose could be reduced approximately 5%. Therefore, using body fix on 4DRT for liver cancer patient is considered effectively.

The Effect of a Bed-Backrest Elevation System Combined With Hip and Knee Flexion on Lower Extremity Body-Pressure Reduction

  • Kim, Min-Hee;Yoo, Won-Gyu;Yi, Chung-Hwi;Kim, Han-Sung;Kim, Su-Jin
    • Physical Therapy Korea
    • /
    • v.15 no.4
    • /
    • pp.59-63
    • /
    • 2008
  • Pressure sores are painful and needless complications of critical illness. and manifest as a localized area of ischemic necrosis of tissue caused by pressure. This study analyzed the bed-backrest elevation system combined with hip and knee flexion for lower extremity lower pressure reduction. Eight healthy adults aged 21 to 26 years were recruited. The Body Pressure Measurement Mat of the TekScan system was used to measure the location and magnitude of the peak pressures on the body bed interface. The SPSS statistical package was used to analyze the significance of differences between the general bed-backrest elevation system and the bed-backrest elevation system combined with hip and knee flexion using the paired t-test. The result showed that the body-pressure of the lower extremity was more significantly reduced for the bed-backrest elevation system combined with hip and knee flexion ($26.6{\pm}4.3$ mmHg) than a general bed-backrest elevation system ($37.3{\pm}5.2$ mmHg) (p<.05).

  • PDF

A Study of the Patternmaking Methods for Mass Customization of the Men's Jacket (남성복 재킷의 Mass Customization을 위한 패턴 제작 방법 연구)

  • Oh, Seol-Young;Chun, Jong-Suk;Suh, Dong-Ae
    • The Research Journal of the Costume Culture
    • /
    • v.14 no.1
    • /
    • pp.40-47
    • /
    • 2006
  • Three-dimensional body scanners were used for years in the clothing manufacturing fields. The 3D body surface provide essential data to draft patterns for mass customization, virtual fit model, and computerized patternmaking systems. This research proposed the methods of drafting patterns for men's jacket by using three dimensional body scan data. Eight male subjects were scanned, the surface data was flattened. The differentials of the flattened body surface and the jacket draft were measured, and analyzed the regressions. To verify the fit of the patterns, the jacket was constructed by the regression formulae and tested by experts. The fit of the jacket were significantly improved rather than a ready-made suit especially the shoulder areas. This means that the methods that we proposed were good to improve the fit of the garments and could be used effectively to implement mass customization strategies in the apparel retail industry.

  • PDF