• 제목/요약/키워드: Scan Model

검색결과 473건 처리시간 0.026초

3D 측정치를 이용한 여성용 모자 패턴 개발 - 6면 크라운 중심으로 - (A Study on Development of the Basic Hat Pattern using 3D Scan Data for Korean Women - Focusing on the 6 pieces Crown -)

  • 김차현;김금화
    • 한국의류산업학회지
    • /
    • 제12권3호
    • /
    • pp.354-363
    • /
    • 2010
  • The purpose of this study was to provide some preliminary results on application of 3D scan data of head shapes to the hat design and pattern-making. This paper defined necessary measurement items and concepts in 3-dimensional images of head shapes. And also it presented the methodology to pattern-making of 6-piece crown hat based on 3D data. It used the data of Size Korea to pick up and choose a head shape model with the average head size of Korean women in their twenties. Main results were: 1. The 3D scan data of head shape was better than the 1 dimensional measurement data. Because I could establish a hat pattern-making theory by the 3D scan data of head. 2. The 3D scan data provided the basis for conceptualization of basic measurement points and items for a better fit of hats as well as the definition of the basic hat circumference. 3. This presented a methodology for analyzing out head shape by 3D scan data, and allowed the derivation of the basic hat circumference from the maximum head circumference. 4. As the 6-piece Crown cloche hat made by this method fitted the head shape model perfectly, this methodology could suggest potential applicability to various hat design.

A Study of Nondestructive Evaluation Using Scan type Magnetic Camera

  • Hwang, Ji-Seong;Lee, Jin-Yi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1830-1835
    • /
    • 2005
  • It is important to estimate the distribution of intensity of a magnetic field for application of magnetic method to industrial nondestructive evaluation. Magnetic camera provides the distribution of a quantitative magnetic field with homogeneous lift-off and same spatial resolution. And it is possible to interpret the distribution of the magnetic field when the dipole model is introduced. This study introduces the numerical and experimental considering of the quantitative evaluation of several size and shapes of the cracks using the magnetic field images of the scan type magnetic camera.

  • PDF

회귀방법에 의한 초음파 진단기의 측면해상도 개선에 관한 연구 (A recursive scheme for improvement of the lateral resolution in B-scan ultrasonography)

  • 김선일;민병구;고명삼
    • 전기의세계
    • /
    • 제31권3호
    • /
    • pp.204-208
    • /
    • 1982
  • The objective of this paper is to present a digital method for improving the lateral resolution of the B-scan images in the medical applications of ultrasound. The method is based upon a mathematical model of the lateral blurring caused by the finite beam width of the transducers. This model provides a simple method of applying a recursive scheme for image restoration with fast computation time. The point spread function (P.S.F.) can be measured by the reflective signals after scanning the small pins located along the depth of interest. From the measured P.S.F., one can compute the coefficient matrices of the inverse discrete-time dynamic state variable equation of the blurring process. Then, a recursive scheme for deblurring is applied to the recorded B-scan to improve the lateral resolution. One major advantage of the present recursive scheme over the transform method is in its applicability for the space-variant imaging, such as in the case of the rotational movement of transducer.

  • PDF

광조형법에 있어서 OFFSET정보생성 알고리즘 개발에 관한 연구 (A Study on Algorithm Development of Offset Data Generation in Stereolithography)

  • 김준안;홍삼열;백인환
    • 한국정밀공학회지
    • /
    • 제13권9호
    • /
    • pp.70-76
    • /
    • 1996
  • In the Stereolithography process, three-dimensional objects are built by sequentially curing, generated by horizontal slicing of a three-dimensional CAD model. The dimensional accuracy of a menufactured part depends on the accuracy of curing performed by laser beam radius and the half of curing width. When offsetting, some slices have collinear segments, coincident vertices, line jerks and open loops. After remove above issues we have correct offsets data. And in last step, these data are used to scan paths.

  • PDF

3차원 인체스캔형상을 재현한 3D 아바타 제작을 위한 가상착의 시스템의 활용성 검증 -CLO 3D 프로그램을 중심으로- (Usability verification of virtual clothing system for the production of a 3D avatar reproduced from 3D human body scan shape data - Focusing on the CLO 3D program -)

  • 홍은희
    • 한국의상디자인학회지
    • /
    • 제22권1호
    • /
    • pp.1-13
    • /
    • 2020
  • The purpose of this study is to create a 3D avatar from 3D human body shape data using the CLO 3D virtual clothing program and to verify the feasibility of avatar production using the virtual clothing system for verifying size and shape. The research method was to select one virtual representative model that is the closest to the mean size of each body item for each age group. Using the 3D human body scan shape of a 40-69 years old male was applied to the CLO 3D virtual wearing system. Using the CLO 3D Avatar conversion menu, we verified the feasibility of creating a 3D avatar that reproduces the human body scan shape. In the dimension comparison between the 3D avatar and the fictitious representative model, the dimension difference was noticeable in height, circumference, and length. However, as a result, the converted 3D avatar showed less than a 5% difference in most human dimensions. In addition, since the body shape and posture were reproduced similarly, the utilization of the avatar was verified.

매설관 주변 지하 공동 탐지를 위한 지하 탐사 레이다의 모의실험 (Laboratory Experiments of a Ground-Penetrating Radar for Detecting Subsurface Cavities in the Vicinity of a Buried Pipe)

  • 현승엽
    • 한국전자파학회논문지
    • /
    • 제27권2호
    • /
    • pp.131-137
    • /
    • 2016
  • 본 논문에서는 지하에 매설된 관 주변에 발생한 지하 공동의 탐지를 위해 지하 탐사 레이다의 가능성을 모의실험으로 조사하였다. 실험 장치는 임펄스형 지하 탐사 레이다 시스템, xy 직교 좌표 로봇, 지하 매질을 채운 탱크, 금속관, 모의실험용 공동 모델로 구현하였다. 특히, 모의실험용 공동 모델은 공기로 채워진 지하 공동의 전기적 특성과 유사하면서 견고한 형상을 유지할 수 있는 스티로폼 ?과 볼을 포장해서 구성하였다. 대표적인 3가지 실험을 통해서 지하 탐사 레이다의 B-scan 자료를 획득하여 2차원 그레이 스케일 영상으로 가시화하였다. B-scan 영상들의 비교를 통해 지하에 매설된 관 주변에 존재하는 지하 공동을 지하 탐사 레이다로 탐지할 수 있음을 보였다.

흉부CT 검사 시 HRCT 영상 재구성의 유용성 (Usefulness Evaluation of HRCT using Reconstruction in Chest CT)

  • 박성민;김긍식;강성민;유병규;이기배
    • 대한디지털의료영상학회논문지
    • /
    • 제17권1호
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.

  • PDF

3D SCAN DATA 를 이용한 직접유한요소모델 생성 (Direct Finite Element Model Generation using 3 Dimensional Scan Data)

  • 이수용;김성진;정재영;박종식;이성범
    • 한국정밀공학회지
    • /
    • 제23권5호
    • /
    • pp.143-148
    • /
    • 2006
  • It is still very difficult to generate a geometry model and finite element model, which has complex and many free surface, even though 3D CAD solutions are applied. Furthermore, in the medical field, which is a big growth area of recent years, there is no drawing. For these reasons, making a geometry model, which is used in finite element analysis, is very difficult. To resolve these problems and satisfy the requests of the need to create a 3D digital file for an object where none had existed before, new technologies are appeared recently. Among the recent technologies, there is a growing interest in the availability of fast, affordable optical range laser scanning. The development of 3D laser scan technology to obtain 3D point cloud data, made it possible to generate 3D model of complex object. To generate CAD and finite element model using point cloud data from 3D scanning, surface reconstruction applications have widely used. In the early stage, these applications have many difficulties, such as data handling, model creation time and so on. Recently developed point-based surface generation applications partly resolve these difficulties. However there are still many problems. In case of large and complex object scanning, generation of CAD and finite element model has a significant amount of working time and effort. Hence, we concerned developing a good direct finite element model generation method using point cloud's location coordinate value to save working time and obtain accurate finite element model.

Does the palatal vault form have an influence on the scan time and accuracy of intraoral scans of completely edentulous arches? An in-vitro study

  • Osman, Reham;Alharbi, Nawal
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권5호
    • /
    • pp.294-304
    • /
    • 2022
  • PURPOSE. The purpose of this study was to evaluate the influence of different palatal vault configurations on the accuracy and scan speed of intraoral scans (IO) of completely edentulous arches. MATERIALS AND METHODS. Three different virtual models of a completely edentulous maxillary arch with different palatal vault heights- Cl I moderate (U-shaped), Cl II deep (steep) and Cl III shallow (flat)-were digitally designed using CAD software (Meshmixer; Autodesk, USA) and 3D-printed using SLA-based 3D-printer (XFAB; DWS, Italy) (n = 30; 10 specimens per group). Each model was scanned using intraoral scanner (Trios 3; 3ShapeTM, Denmark). Scanning time was recorded for all samples. Scanning accuracy (trueness and precision) were evaluated using digital subtraction technique using Geomagic Control X v2020 (Geomagic; 3DSystems, USA). One-way analysis of variance (ANOVA) test was used to detect differences in scanning time, trueness and precision among the test groups. Statistical significance was set at α = .05. RESULTS. The scan process could not be completed for Class II group and manufacturer's recommended technique had to be modified. ANOVA revealed no statistically significant difference in trueness and precision values among the test groups (P=.959 and P=.658, respectively). Deep palatal vault (Cl II) showed significantly longer scan time compared to Cl I and III. CONCLUSION. The selection of scan protocol in complex cases such as deep palatal vault is of utmost importance. The modified, adopted longer path scan protocol of deep vault cases resulted in increased scan time when compared to the other two groups.

3차원 이미지 스캔 기반 MEP 시설물 관리 기술 연구 (Study on 3D Image Scan-based MEP Facility Management Technology)

  • 강태욱
    • 한국BIM학회 논문집
    • /
    • 제6권4호
    • /
    • pp.18-26
    • /
    • 2016
  • Recently, for the purpose of maintenance of facilities and energy, there have been growing cases of the 3D image scan-based reverse design technology mostly in the manufacturing field. In the MEP field, because of differences between design and physical model, the reverse technology has been utilized in factory facilities such as a semiconductor factory. Because 3D point clouds from scanning include accurate 3D object information, the efficiency of management works related to the complex MEP facilities can be enhanced. In this study, the reverse technology was surveyed, and the MEP facility management based on 3D image scanning was analyzed. Based on the results, a method of 3D image scan-based MEP facility management was proposed.