• Title/Summary/Keyword: Scan Mechanism

Search Result 115, Processing Time 0.026 seconds

Renal Localization of Ga-67 Citrate in Noninfectious Nephritis (비세균성 신염환자에서 신장내 $^{67}Ga-Citrate$ 흡수에 관한 연구)

  • Lee, Kang-Wook;Jeong, Min-Soo;Rhee, Sunn-Kgoo;Kim, Sam-Yong;Shin, Young-Tai;Ro, Heung-Kyu
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.318-326
    • /
    • 1992
  • Ga-67 citrate scan has been requested for detection or follow-up of inflammatory or neoplastic disease. Visualization of Ga-67 citrate in the kidneys at 48 and 72 hr post injection is usually interpreted as evidence of renal pathology. But precise mechanisms of abnormal Ga-67 uptake in kidneys were unknown. We undertook a study to determine the clinical value of Ga-67 citrate imaging of the kidneys in 68 patients with primary or secondary nephropathy confirmed by renal biopsy and 66 control patients without renal disease. Renal uptake in 48 to 72 hr images was graded as follows: Grade 0=back-ground activity:1=faint uptake greater than background;2=definite uptake, but less than lumbar vertebrae; 3=same uptake as lumbar vertebrae, but less than liver; 4=same or higher uptake than liver. The results were as follows. 1) 42 of 65 (62%) patients with noninfectious nephritis showed grade 2 or higher Ga-67 renal uptake but only 10 percent of control patients showed similar uptake. 2) In 14 patients with systemic lupus erythematosus, 8 of 9 (89%) patients with lupus nephritis exhibited marked renal uptake 3) 36 of 41 patients (88%) with combined nephrotic syndrome showed Grade 2 or higher renal uptake. 4) Renal Ga-67 uptake was correlated with clinical severity of nephrotic syndrome determined by serum albumin level, 24 hr urine protein excretion and serum lipid levels. 5) After complete remission of nephrotic syndrome, renal uptake in all 8 patients who were initially Grade 3 or 4, decreased to Grade 1 or 0. In conclusion, we think that the mechanism of renal Ga-67 uptake in nephrotic syndrome might be related to the pathogenesis of nephrotic syndrome. In systemic lupus erythematosus, Ga-67 citrate scan is useful in predicting renal involvement.

  • PDF

Inscribed Transceiver Optical System Design for Laser Radar with Zoom-type Expander (줌렌즈 광속확대기를 적용한 레이저 레이더용 송수광 내접형 광학계 설계)

  • Koh, Hae Seog;Ok, Chang Min;Hong, Jin Sug;Lee, Chang Jae;Park, Chan Geun;Kim, Hyun Kyu
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.1
    • /
    • pp.23-28
    • /
    • 2013
  • In this paper, an optical system was designed for 3D imaging laser radar with optical scanner. In order to make it easy to scan, the system was designed to inscribe the transmitting objective lens in the receiving lens. In transmitting optics, the beam expander was designed to have a zoom mechanism so that the transmitted beam size would be 4.8 m or 6.8 m at 1 km distance, when the laser source's numerical aperture value is between 0.13 and 0.22. The beam diameter at the target 1 km away was confirmed by design program. The receiving optics for the returning beam from the target was designed for the $16{\times}16$ array detector with $100{\mu}m$ pixel width. The spot diameter in every pixel was designed and verified to be less than $55{\mu}m$. The receiving optics' obscuration ratio by transmitting optics was 11%.

Full Parametric Impedance Analysis of Photoelectrochemical Cells: Case of a TiO2 Photoanode

  • Nguyen, Hung Tai;Tran, Thi Lan;Nguyen, Dang Thanh;Shin, Eui-Chol;Kang, Soon-Hyung;Lee, Jong-Sook
    • Journal of the Korean Ceramic Society
    • /
    • v.55 no.3
    • /
    • pp.244-260
    • /
    • 2018
  • Issues in the electrical characterization of semiconducting photoanodes in a photoelectrochemical (PEC) cell, such as the cell geometry dependence, scan rate dependence in DC measurements, and the frequency dependence in AC measurements, are addressed, using the example of a $TiO_2$ photoanode. Contrary to conventional constant phase element (CPE) modeling, the capacitive behavior associated with Mott-Schottky (MS) response was successfully modeled by a Havriliak-Negami (HN) capacitance function-which allowed the determination of frequency-independent Schottky capacitance parameters to be explained by a trapping mechanism. Additional polarization can be successfully described by the parallel connection of a Bisquert transmission line (TL) model for the diffusion-recombination process in the nanostructured $TiO_2$ electrode. Instead of shunt CPEs generally employed for the non-ideal TL feature, TL models with ideal shunt capacitors can describe the experimental data in the presence of an infinite-length Warburg element as internal interfacial impedance - a characteristic suggested to be a generic feature of many electrochemical cells. Fully parametrized impedance spectra finally allow in-depth physicochemical interpretations.

Value of Repeat Brain Computed Tomography in Children with Traumatic Brain Injury (소아 두부외상 환자에서의 반복적인 두부 CT 검사의 유용성)

  • Jo, Ho jun;Lim, Yong Su;Kim, Jin Joo;Cho, Jin Seong;Hyun, Sung Youl;Yang, Hyuk Jun;Lee, Gun
    • Journal of Trauma and Injury
    • /
    • v.28 no.3
    • /
    • pp.149-157
    • /
    • 2015
  • Purpose: Traumatic brain injury (TBI) is the most common cause of pediatric trauma patients came to the emergency department. Without guidelines, many of these children underwent repeat brain computed tomography (CT). The purpose of this study was to evaluate the value of repeat brain CT in children with TBI. Methods: We conducted a retrospective study of TBI in children younger than 19 years of age who visited the emergency department (ED) from January 2011 to December 2012. According to the Glasgow Coma Scale (GCS) and Pediatric Glasgow Coma Scale score of the patients, study population divided in three groups. Clinical data collected included age, mechanism of injury, type of TBI, and outcome. Results: A Total 83 children with TBI received repeat brain CT. There were no need for neurosurgical intervention in mild TBI (GCS score 13-15) group who underwent routine repeat CT. 4 patients of mild TBI group, received repeat brain CT due to neurological deterioration, and one patient underwent neurosurgical intervention. Routine repeat CT identified 12 patients with radiographic progression. One patient underwent neurosurgical intervention based on the second brain CT finding, who belonged to the moderate TBI (GCS score 9-12) group. Conclusion: Our study showed that children with mild TBI can be observed without repeat brain CT when there is no evidence of neurologic deterioration. Further study is needed for establish indication for repetition of CT scan in order to avoid unnecessary radiation exposure of children.

  • PDF

Breast Cytology Diagnosis using a Hybrid Case-based Reasoning and Genetic Algorithms Approach

  • Ahn, Hyun-Chul;Kim, Kyoung-Jae
    • Proceedings of the Korea Inteligent Information System Society Conference
    • /
    • 2007.05a
    • /
    • pp.389-398
    • /
    • 2007
  • Case-based reasoning (CBR) is one of the most popular prediction techniques for medical diagnosis because it is easy to apply, has no possibility of overfitting, and provides a good explanation for the output. However, it has a critical limitation - its prediction performance is generally lower than other artificial intelligence techniques like artificial neural networks (ANNs). In order to obtain accurate results from CBR, effective retrieval and matching of useful prior cases for the problem is essential, but it is still a controversial issue to design a good matching and retrieval mechanism for CBR systems. In this study, we propose a novel approach to enhance the prediction performance of CBR. Our suggestion is the simultaneous optimization of feature weights, instance selection, and the number of neighbors that combine using genetic algorithms (GAs). Our model improves the prediction performance in three ways - (1) measuring similarity between cases more accurately by considering relative importance of each feature, (2) eliminating redundant or erroneous reference cases, and (3) combining several similar cases represent significant patterns. To validate the usefulness of our model, this study applied it to a real-world case for evaluating cytological features derived directly from a digital scan of breast fine needle aspirate (FNA) slides. Experimental results showed that the prediction accuracy of conventional CBR may be improved significantly by using our model. We also found that our proposed model outperformed all the other optimized models for CBR using GA.

  • PDF

A Comparative Study of Methods of Measurement of Peripheral Pulse Waveform

  • Kang, Hee-Jung;Lee, Yong-Heum;Kim, Kyung-Chul;Han, Chang-Ho
    • The Journal of Korean Medicine
    • /
    • v.30 no.3
    • /
    • pp.98-105
    • /
    • 2009
  • Objective: Increased aortic and carotid arterial augmentation index (AI) is associated with the risk of cardiovascular disease. The most widely used approach for determining central arterial AI is by calculating the aortic pressure waveform from radial arterial waveforms using a transfer function. But how the change of waveform by applied pressure and the pattern of the change rely on subject's characteristics has not been recognized. In this study, we use a new method for measuring radial waveform and observe the change of waveform and the deviation of radial AI in the same position by applied pressure. Method: Forty-six non-patient volunteers (31 men and 15 women, age range 21-58 years) were enrolled for this study. Informed consent in a form approved by the institutional review board was obtained in all subjects. Blood pressure was measured on the left upper arm using an oscillometric method, radial pressure waves were recorded with the use of an improved automated tonometry device. DMP-3000(DAEYOMEDI Co., Ltd. Ansan, Korea) has robotics mechanism to scan and trace automatically. For each subject, we performed the procedure 5 times for each applied pressure level. We could thus obtain 5 different radial pulse waveforms for the same person's same position at different applied pressures. All these processes were repeated twice for test reproducibility. Result: Aortic AI, peripheral AI and radial AI were higher in women than in men (P<0.01), radial AI strongly correlated with aortic AI, and radial AI was consistently approximately 39% higher than aortic AI. Relationship between representative radial AI of DMP-3000 and peripheral AI of SphygmoCor had strongly correlation. And there were three patterns in change of pulse waveform. Conclusion: In this study, it is revealed the new device was sufficient to measure how radial AI and radial waveform from the same person at the same time change under applied pressure and it had inverse-proportion to applied pressure.

  • PDF

A Fast Mount and Stability Scheme for a NAND Flash Memory-based File System (NAND 플래시 메모리 기반 파일 시스템을 위한 빠른 마운트 및 안정성 기법)

  • Park, Sang-Oh;Kim, Sung-Jo
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.34 no.12
    • /
    • pp.683-695
    • /
    • 2007
  • NAND flash memory-based file systems cannot store their system-related information in the file system due to wear-leveling of NAND flash memory. This forces NAND flash memory-based file systems to scan the whole flash memory during their mounts. The mount time usually increases linearly according to the size of and the usage pattern of the flash memory. NAND flash memory has been widely used as the storage medium of mobile devices. Due to the fact that mobile devices have unstable power supply, the file system for NAND flash memory requires stable recovery mechanism from power failure. In this paper, we present design and implementation of a new NAND flash memory-based file system that provides fast mount and enhanced stability. Our file system mounts 19 times faster than JFFS2's and 2 times faster than YAFFS's. The stability of our file system is also shown to be equivalent to that of JFFS2.

Association of miR-1266 with Recurrence/Metastasis Potential in Estrogen Receptor Positive Breast Cancer Patients

  • Sevinc, Elif Demirdogen;Egeli, Unal;Cecener, Gulsah;Tezcan, Gulcin;Tunca, Berrin;Gokgoz, Sehsuvar;Tasdelen, Ismet;Tolunay, Sahsine;Evrensel, Turkkan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.1
    • /
    • pp.291-297
    • /
    • 2015
  • The Homeobox B13 (HOXB13):Interleukin 17 Receptor B (IL17BR) index of estrogen receptor (ER)-positive breast cancer (ER (+) BC) patients may be a potential biomarker of recurrence/ metastasis. However, effects of microRNA (miRNA) binding to the 3' untranslated region (3' UTR) of HOXB13 and IL17BR and its function on recurrence/metastasis in ER (+) BC remains elusive. The aims of this study were to determine the expression of miRNAs that bind to 3' UTR of HOXB13 and IL17BR in ER (+) BC patients and asess the effects of these miRNAs on recurrence/metastasis. The expression profiles of HOXB13 and IL17BR were evaluated using RT-PCR in tumors and normal tissue samples from 40 ER (+) BC patients. The expression level of 4 miRNAs, which were predicted to bind the 3' UTR of HOXB13 and IL17BR using TargetScan, microRNA.org and miRDB online databases, were further evaluated with RT-PCR. Our findings demonstrated that high miR-1266 levels might be significant prognostic factor for recurrence/metastasis occurrence (3.05 fold p=0.004) and tamoxifen response (3.90 fold; p=0.2514) in ER (+) BC cases. Although we suggest that modulation of miR-1266 expression may be an important mechanism underlying the chemoresistance of ER (+) BC, advanced studies and validation are required.

Surface Reaction of Na0.5K0.5NbO3 Thin Films in Inductively Coupled BCl3/Cl2/Ar Plasma (BCl3/Cl2/Ar 플라즈마에서의 Na0.5K0.5NbO3 박막의 표면반응)

  • Kim, Dong-Pyo;Um, Doo-Seung;Kim, Gwan-Ha;Woo, Jong-Chang;Kim, Chang-Il
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.6
    • /
    • pp.269-273
    • /
    • 2008
  • The etch of $(Na_{0.5}K_{0.5})NbO_3$ (NKN) thin film was performed in $BCl_3/Cl_2/Ar$ inductively coupled plasma. It was found that the 1sccm addition $BCl_3$ (5%) into $Cl_2/Ar$ plasma caused a non-monotonic behavior of the NKN etch rate. The maximum etch rate of NKN was 95.3 nm/min at $BCl_3$ (1 sccm)/$Cl_2$ (16 sccm)/Ar (4 sccm), 800 W ICP power, 1 Pa pressure and 400 W bias power. The NKN etch rate shows a monotonic behavior a s the bias power increases. The analysis of the narrow scan spectra of XPS for both a s-deposited and etched NKN films allowed one to assume ion assisted etch mechanism. The most probable reason for the maximum etch rate can be defined as a concurrence of chemical and physical etch pathways.

Fatigue Crack Growth Characteristics of 9% Ni Steel Welded Joint for LNG Storage Tank at Low Temperature (LNG 저장탱크용 9% Ni강 용접부의 저온피로균열진전 특성)

  • Kim, Jae-Hoon;Shim, Kyue-Taek;Kim, Young-Kyun;Ahn, Byoung-Wook
    • Journal of Welding and Joining
    • /
    • v.28 no.5
    • /
    • pp.45-50
    • /
    • 2010
  • The fatigue crack growth characteristics of base metal and weld joint of 9% Ni steel for LNG storage tank was carried out using CT specimen at room temperature and $-162^{\circ}C$. Fatigue crack growth rate of base and weld metals at RT and $-162^{\circ}C$ was coincided with a single line independent of the change of stress ratio and temperature. In the region of lower stress intensity factor range, fatigue crack growth rate at $-162^{\circ}C$ was slower than that at RT, and the slop of fatigue crack growth rate at $-162^{\circ}C$ increased sharply with propagating of fatigue crack, fatigue crack growth rate at RT and $-162^{\circ}C$ was intersected near the region of $2{\times}10-4\;mm$/cycle, and after the intersection region, fatigue crack growth rate at $-162^{\circ}C$ was faster than that at RT. The micro-fracture mechanism using SEM shows the ductile striation in the stable crack growth region. Also the defects of weld specimen after fatigue testing were detected using the A scan of ultrasonic apparatus.