• Title/Summary/Keyword: Scan Mechanism

Search Result 115, Processing Time 0.032 seconds

Performance of Wireless Mobile Node based on Experience Path with SSEPT Scheme (무선 단말의 이동경로를 고려한 선택적 채널탐색방식의 성능분석)

  • Yoon, Hong;Yoon, Chong-Ho
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.87-88
    • /
    • 2006
  • In this paper, we propose a new selective scanning scheme based on hand-off path information, which can provide an efficient reducing of delay time. This scheme eliminates almost of the scanning delay time by using Selective Scan based on Experience Path Table(SSEPT) algorithm and also completed hand-off within few milliseconds by using the next candidate channel indexing mechanism. Our scheme reduces the total number of scanning channels as well as the delay time on each channel. From the simulation result, we show that the proposed scheme is advantageous over the legacy schemes in terms of the scanning channels and the total delay time.

  • PDF

A study on SLA(Scanned Linear Array) Applications for Mobile Communication Units (이동통신 단말기용 SLA(Scanned Linear Array) 적용에 관한 연구)

  • 김인회;안원석;문현찬
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.275-278
    • /
    • 1998
  • In recent years, miniaturization has become the key factor in the development of mobile communication system. Portable communications and computing devices suffer from two conflicting requirements which are device size to be as small as possible and large, high resolution display. These problems can be solved by virtual display. Any display in which the user views an image through an optical system is a virtual display. It provides a display which is high resolution, appears large to the viewer and at the same time occupies little physical space. In this study, handhold units of mobile communication was investigated through use of the SLA(Scanned Linear Array). The basic SLA mechanism comprises a linear array of LED's, a magnifying lens, and a scan mirror. To optimize virtual image, we investigated optical system design and operating condition for each part.

  • PDF

Development of opto-mechanical switch (광스위치 개발)

  • Park, Kap-Seok;Choi, Shin-Ho;Jang, Eun-Sang;Kim, Seong-Il;Lee, Byeong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2464-2466
    • /
    • 1998
  • A switch is a component with two or more ports that selectively transmits, redirects, or blocks optical power in a fiber transmission line. Our switch uses rotation mechanism using stepping motor, hence the common optical fiber can scan and allign to one of the arrayed N optical fibers to provide optical path by electronic precise control. The developed switch is consisted of switching module and its control module. The performance parameters of a switching loss and a repeatability are considered very important. We performed the study to reduce the switching loss and improve the repeatability of switch. The switch can be widely used as a test instrument of optical device and of optical cable in factory, also of optical cable monitoring systems.

  • PDF

"Brain Stunning" Atypical Feature of tPA Thrombolysis Following Aneurysm Embolization

  • Park, Min-Woo;Yi, Hyeong-Joong;Gupta, Rishi;Horowitz, Michael B.
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.4
    • /
    • pp.300-302
    • /
    • 2006
  • "Stunning" represents prolonged contractile depression of any muscular component after alleviation of severe ischemia, as shown in reperfusion following acute myocardial ischemia or ischemic stroke. Clinically, it presents with no or delayed recovery past to thrombolytic therapy but its pathogenic mechanism is not fully uncovered yet. We describe a unique case of a 63-year-old woman, who was undertaken endovascular coiling for the aneurysms, deteriorated several hours later without known cause, and showed delayed clinical improvement over the next 3 days following thrombolysis. Immediate post-thrombolysis magnetic resonance imaging scan showed no apparent abnormality except for high signal intensity within the corresponding hemisphere. Reversible but delayed nature of " brain stunning" can be explained by these images and it seems to be caused by a certain type of reperfusion injury.

Multi-feature local sparse representation for infrared pedestrian tracking

  • Wang, Xin;Xu, Lingling;Ning, Chen
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.3
    • /
    • pp.1464-1480
    • /
    • 2019
  • Robust tracking of infrared (IR) pedestrian targets with various backgrounds, e.g. appearance changes, illumination variations, and background disturbances, is a great challenge in the infrared image processing field. In the paper, we address a new tracking method for IR pedestrian targets via multi-feature local sparse representation (SR), which consists of three important modules. In the first module, a multi-feature local SR model is constructed. Considering the characterization of infrared pedestrian targets, the gray and edge features are first extracted from all target templates, and then fused into the model learning process. In the second module, an effective tracker is proposed via the learned model. To improve the computational efficiency, a sliding window mechanism with multiple scales is first used to scan the current frame to sample the target candidates. Then, the candidates are recognized via sparse reconstruction residual analysis. In the third module, an adaptive dictionary update approach is designed to further improve the tracking performance. The results demonstrate that our method outperforms several classical methods for infrared pedestrian tracking.

Characteristics of Magnetic Resonance(M.R.) and Comprehension of its Imaging Mechanism (자기공명(M.R.)진단법의 특징 및 그 영상기전의 이해)

  • Chang, Jae-Chun;Hwang, Mi-Soo;Kim, Sun-Yong
    • Journal of Yeungnam Medical Science
    • /
    • v.4 no.1
    • /
    • pp.1-15
    • /
    • 1987
  • Magnetic Resonance (M.R.) is rapidly emerging technique that provides high quality images and potentially provides much more diagnostic information than do conventional imaging modalities. M.R.I. is conceptually quite different from currently used imaging methods. The complex nature of M.R.I. allows a great deal of flexibility in image product ion and available information, and key points are as follows. 1. M.R.I. offers a non-invasive technique with which to gene rate in vivo human images without ionizing radiation and with no known adverse biological effects. 2. Imaging mechanism of M.R.I. is quite different from conventional imaging modality and for more accurate diagnostic application, It is necessary for physician to understand imaging mechanism of M.R.I. 3. M.R. makes available basic chemical parameters that may provide to be useful for diagnostic medical imaging and more specific pathophysiologic information which are not available by alternate techniques. 4. M.R. can be produced by number of different methods. This flexibility allows the imaging technique to be applicated for particular clinical purpose. Multiplanar and three dimensional imaging may extend the imaging process beyond the single section available with current CT. 5. Future directions include efforts to; a. Further development of hard ware b. More fasternning scan time c. Respiratory and cardiac gated imaging d. Imaging of additional nuclei except hydrogen e. Further development of contrast media f. M.R. in vivo spectroscopy g. Real time M.R. imaging.

  • PDF

An Efficient Test Access Mechanism for System On a Chip Testing (시스템 온 칩 테스트를 위한 효과적인 테스트 접근 구조)

  • Song, Dong-Seop;Bae, Sang-Min;Gang, Seong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.5
    • /
    • pp.54-64
    • /
    • 2002
  • Recently System On a Chip(SoC) design based on IP cores has become the trend of If design To prevent the testing problem from becoming the bottleneck of the core-based design, defining of an efficient test architecture and a successful test methodology are mandatory. This paper describes a test architecture and a test control access mechanism for SoC based on IEEE 1149.1 boundary,scan. The proposed SoC test architecture is fully compatible with IEEE P1500 Standard for Embedded Core Test(SECT), and applicable for both TAPed cores and Wrapped cores within a SOC with the same test access mechanism. Controlled by TCK, TMS, TDI, and TDO, the proposed test architecture provides a hierarchical test feature.

Anomaly Detection Mechanism based on the Session Patterns and Fuzzy Cognitive Maps (퍼지인식도와 세션패턴 기반의 비정상 탐지 메커니즘)

  • Ryu Dae-Hee;Lee Se-Yul;Kim Hyeock-Jin;Song Young-Deog
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.6 s.38
    • /
    • pp.9-16
    • /
    • 2005
  • Recently, since the number of internet users is increasing rapidly and, by using the Public hacking tools, general network users can intrude computer systems easily, the hacking problem is setting more serious. In order to prevent the intrusion. it is needed to detect the sign in advance of intrusion in a Positive Prevention by detecting the various forms of hackers intrusion trials to know the vulnerability of systems. The existing network-based anomaly detection algorithms that cope with port-scanning and the network vulnerability scans have some weakness in intrusion detection. they can not detect slow scans and coordinated scans. therefore, the new concept of algorithm is needed to detect effectively the various. In this Paper, we propose a detection algorithm for session patterns and FCM.

  • PDF

The Delamination and Fatigue Crack Propagation Behavior in A15052/AFRP Laminates Under Cyclic Bending Moment (반복-굽힘 모멘트의 진폭에 따른 A15052/AFRP 적층재의 층간분리 영역과 피로균열진전 거동)

  • Song, Sam-Hong;Kim, Cheol-Ung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.8
    • /
    • pp.1277-1286
    • /
    • 2001
  • Aluminum 5052/Aramid Fiber Reinforced Plastic(Al5052/AFRP) laminates are applied to the fuselage-wing intersection. The Al5052/AFRP laminates suffer from the cyclic bending moment of variable amplitude during the service. Therefore, the influence of cyclic bending moment on the delamination and the fatigue crack propagation behavior in Al5052/AFRP laminate was investigated in this study. Al5052/AFRP laminate composite consists of three thin sheets of Al5052 and two layers of unidirectional aramid fibers. The cyclic bending moment fatigue tests were performed with five different levels of bending moment. The shape and size of the delamination zone formed along the fatigue crack between Al5052 sheet and aramid fiber-adhesive layer were measured by an ultrasonic C-scan. The relationships between da/dN and ΔK, between the cyclic bending moment and the delamination zone size, and between the fiber bridging mechanism and the delamination zone were studied. Fiber failures were not observed in the delamination zone in this study. It represents that the fiber bridging modification factor should turn out to increase and that the fatigue crack growth rate should decrease. The shape of delamination zone turns out to be semi-elliptic with the contour decreased non-linearly toward the crack tip.

Incomplete bone formation after sinus augmentation: A case report on radiological findings by computerized tomography at follow-up

  • Lee, Kyung-Shil;Kwon, Young-Hyuk;Herr, Yeek;Shin, Seung-Il;Lee, Ji-Yeon;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.6
    • /
    • pp.283-288
    • /
    • 2010
  • Purpose: The aim of this case report is to present a case of incomplete bone formation after sinus augmentation. Methods: A patient having alveolar bone resorption of the maxillary posterior edentulous region and advanced pneumatization of the maxillary sinus was treated with sinus elevation using deproteinized bovine bone in the Department of Periodontology, Kyung Hee University School of Dentistry and re-evaluated with computed tomography (CT) follow-up. Results: Even though there were no significant findings or abnormal radiolucency on the panoramic radiograph, incomplete bone formation in the central portion of the augmented sinus was found fortuitously in the CT scan. The CT scan revealed peri-implant radiolucency in the apical portion of the implant placed in the augmented maxillary sinus. Nevertheless, the dental implants placed in the grafted sinus still functioned well at over 15 months follow-up. Conclusions: The result of this case suggests that patients who received maxillary sinus augmentation may experience incomplete bone formation. It is possible that 1) osteoconductive graft material with poor osteogenic potential, 2) overpacking of graft material that restricts the blood supply, and 3) bone microbial contamination may cause the appearance of incomplete bone formation after sinus augmentation. Further studies are needed to elucidate the mechanism of this unexpected result and care must be taken to prevent it.