• 제목/요약/키워드: Scan Impedance(SI)

검색결과 7건 처리시간 0.02초

개방형 도파관 배열안테나의 조향소자 특성 (Scan Element Characteristics of Open-Ended Waveguide Array Antenna)

  • 김동석;김태현;박동철;김찬홍
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2005년도 종합학술발표회 논문집 Vol.15 No.1
    • /
    • pp.347-352
    • /
    • 2005
  • Scan Element Pattern(SEP) and Scan Impedance(SI) concepts are used to analyze the characteristics of open-ended waveguide array, which is the representative phased array antenna element in C-band and X-band. Transmit SEP's are calculated for 15$\sim$15 subarray and SI's are obtained by applying periodic boundary conditions for a unit cell of the given array condition. CST's MWS and Ansoft's HFSS are utilized for each analysis. Some relations are reviewed between the two results, which are based on mutual coupling effects. For validation purpose, an 8$\sim$8 subarray is constructed and tested. Transmit SEP measured in MTG's far-field range shows good agreement with the calculated transmit SEP.

  • PDF

개방형 도파관 배열 안테나의 조향 소자 패턴 및 조향 임피던스에 관한 연구 (Scan Element Pattern and Scan Impedance of Open-Ended Waveguide Away Antenna)

  • 유제우;라동균;김동석;김찬홍;박동철
    • 한국전자파학회논문지
    • /
    • 제18권1호
    • /
    • pp.7-14
    • /
    • 2007
  • 본 논문에서는 직사각형 개방형 도파관들이 삼각 격자 형태로 배열된 구조의 조향 특성을 연구하였다. 무한배열 해석 이론에서의 도파관 모드와 플로케 모드 함수를 이용하여 도파관 내부와 외부의 전계 성분을 적분방정식으로 유도하고 이를 프로그램화하여 조향 소자 패턴과 조향 임피던스를 수치해석하였다. CST사의 MWS(Microwave Studio)와 Ansoft사의 HFSS(High Frequency Structure Simulator)를 이용하여 얻어진 시뮬레이션 결과와 계산된 결과를 비교하였고, 아울러 $8{\times}8$ 부배열을 제작하고 측정하여 시뮬레이션과 계산 결과와 비교함으로써 접근 방법의 타당성을 검증하였다. 제작된 부배열 안테나는 X-대역에 있는 중심주파수의 10.5 % 대역 내에서 E-면(방위각)과 H-면(고각) 조향 범위 ${\pm}45^{\circ}C,\;{\pm}20^{\circ}C$ 내에서 평탄한 이득을 갖고 또한 -10 dB 이하의 반사 손실을 갖는 것을 확인하였다.

Interval Scan Inspection Technique for Contact Failure of Advanced DRAM Process using Electron Beam-Inspection System

  • Oh, J.H.;Kwon, G.;Mun, D.Y.;Kim, D.J.;Han, I.K.;Yoo, H.W.;Jo, J.C.;Ominami, Y.;Ninomiya, T.;Nozoe, M.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제12권1호
    • /
    • pp.34-40
    • /
    • 2012
  • We have developed a highly sensitive inspection technique based on an electron beam inspection for detecting the contact failure of a poly-Si plugged layer. It was difficult to distinguish the contact failure from normal landing plugs with high impedance. Normally, the thermal annealing method has been used to decrease the impedance of poly-Si plugs and this method increases the difference of charged characteristics and voltage contrast. However, the additional process made the loss of time and broke down the device characteristics. Here, the interval scanning method without thermal annealing was effectively applied to enhance the difference of surface voltage between well-contacted poly-Si plugs and incomplete contact plugs. It is extremely useful to detect the contact failures of non-annealed plug contacts with high impedance.

Electrochemical Behavior of Plasma Electrolytic Oxidized Films Formed in Solution Containing Mn, Mg and Si Ions

  • Lim, Sang-Gyu;Choe, Han Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.80-80
    • /
    • 2017
  • Titanium and its alloys that have a good biocompatibility, corrosion resistance, and mechanical properties such as hardness and wear resistance are widely used in dental and orthopedic implant applications. However, they do not form a chemical bond with bone tissue. Plasma electrolytic oxidation (PEO) that combines the high voltage spark and electro-chemical oxidation is a novel method to form ceramic coatings on light metals such as tita-nium and its alloys. This is an excellent re-producibility and economical, because the size and shape control of the nano-structure is relatively easy. Silicon (Si), manganese (Mn), and magne-sium (Mg) have a useful to bone. Particularly, Si has been found to be essential for normal bone, cartilage growth, and development. Mn influences regulation of bone remodeling be-cause its low content in body is connected with the rise of the concentration of calcium, phosphates and phosphatase out of cells. Pre-studies have shown that Mg plays very im-portant roles in essential for normal growth and metabolism of skeletal tissue in verte-brates and can be detected as minor constitu-ents in teeth and bone. In this study, Electrochemical behavior of plasma electrolytic oxidized films formed in solution containing Mn, Mg and Si ions were researched using various experimental in-struments. A series of Si-Mn-Mg coatings are produced on Ti dental implant using PEO, with the substitution degree, respectively, at 5 and 10%. The potentiodynamic polarization and AC impedance tests for corrosion behav-iors were carried out in 0.9% NaCl solution at similar body temperature using a potentiostat with a scan rate of 1.67mV/s and potential range from -1500mV to + 2000mV. Also, AC impedance was performed at frequencies anging from 10MHz to 100kHz for corrosion resistance.

  • PDF

Electrochemical characteristics of Ca, P, Sr, and Si Ions from PEO-treated Ti-6Al-4V Alloy Surface

  • Yu, Ji-Min;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.154-154
    • /
    • 2017
  • Ti-6Al-4V alloys are widely used as metal-lic biomaterials in dentistry and orthopedics due to its excellent biocompatibility and me-chanical properties. However, because of low biological activity, it is difficult to form bone growth directly on the surface of titanium implants. For this reason, surface treatment of plasma electrolytic oxidation(PEO) was used for dental implants. To enhance bioac-tivity on the surface, strontium(Sr) and sili-con(Si) ions can be added to PEO treated sur-face in the electrolyte containing these ions. The presence of Sr in the coating enhances osteoblast activity and differentiation, where-as it inhibits osteoclast production and prolif-eration. And Si has been found to be essen-tial for normal bone, cartilage growth, and development. In this study, electrochemical characteristics of Ca, P, Sr, and Si ions from PEO-treated Ti-6Al-4V alloy surface was re-searched using various experimental instruments. DC power is used and Ti-6Al-4V al-loy was subjected to a voltage of 280 V for 3 minutes in the electrolyte containing 5, 10, 20M% Sr ion and 5M% Si ion. The morphol-ogies of PEO-treated Ti-6Al-4V alloy by electrochemical anodization were examined by field-emission scanning electron micro-scopes (FE-SEM), energy dispersive x-ray spectroscopy (EDS), x-ray diffraction (XRD) and corrosion analysis using AC impedance and potentiodynamic polarization test in 0.9% NaCl solution at similar body tempera-ture using a potentiostat with a scan rate of 1.67mV/s and potential range from -1500mV to + 2000mV.

  • PDF

Corrosion Behavior of Ti-6Al-4V Alloy after Plasma Electrolytic Oxidation in Solutions Containing Ca, P and Zn

  • Hwang, In-Jo;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.120-120
    • /
    • 2016
  • Ti-6Al-4V alloy have been used for dental implant because of its excellent biocompatibility, corrosion resistance, and mechanical properties. However, the integration of such implant in bone was not in good condition to achieve improved osseointergraiton. For solving this problem, calcium phosphate (CaP) has been applied as coating materials on Ti alloy implants for hard tissue applications because its chemical similarity to the inorganic component of human bone, capability of conducting bone formation and strong affinity to the surrounding bone tissue. Various metallic elements, such as strontium (Sr), magnesium (Mg), zinc (Zn), sodium (Na), silicon (Si), silver (Ag), and yttrium (Y) are known to play an important role in the bone formation and also affect bone mineral characteristics, such as crystallinity, degradation behavior, and mechanical properties. Especially, Zn is essential for the growth of the human and Zn coating has a major impact on the improvement of corrosion resistance. Plasma electrolytic oxidation (PEO) is a promising technology to produce porous and firmly adherent inorganic Zn containing $TiO_2(Zn-TiO_2)$coatings on Ti surface, and the a mount of Zn introduced in to the coatings can be optimized by altering the electrolyte composition. In this study, corrosion behavior of Ti-6Al-4V alloy after plasma electrolytic oxidation in solutions containing Ca, P and Zn were studied by scanning electron microscopy (SEM), AC impedance, and potentiodynamic polarization test. A series of $Zn-TiO_2$ coatings are produced on Ti dental implant using PEO, with the substitution degree, respectively, at 0, 5, 10 and 20%. The potentiodynamic polarization and AC impedance tests for corrosion behaviors were carried out in 0.9% NaCl solution at similar body temperature using a potentiostat with a scan rate of 1.67mV/s and potential range from -1500mV to +2000mV. Also, AC impedance was performed at frequencies ranging from 10MHz to 100kHz for corrosion resistance.

  • PDF

Corrosion Charateristics of PEO-treated Ti-6Al-4V Alloy in Solution Containing Si and Mg Ions

  • Park, Seon-Yeong;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.153-153
    • /
    • 2017
  • The application of the coating supports the mechanical characteristics of the implant, and various materials and coatings are currently being used in the implant in a way to accelerate adhesion. Especially, plasma electrolytic oxidation (PEO) coating has been proposed continually with good surface treatment of titanium alloys. Also, the PEO process can incorporate Ca and P ions on the titanium surface through variables varied factor. PEO process for bioactive surface has carried out in electrolytes containing Ca and P ions. Natural bone is composed of mineral elements such as Mg, Si, Zn, Sr, and Mn, etc. Especially, Mg and Si of these elements play role in bone formation and growth after clinical implantation of bio-implants. In this study, corrosion charateristics of PEO-treated Ti-6Al-4V alloy in solution containing Si and Mg ions has been investigated using several experimental techniques. The PEO-treated surfaces were identified by X-ray diffraction, using a diffractometer (XRD, Philips X' pert PRO, Netherlands) with Cu $K{\alpha}$ radiation. The morphology was observed by field-emission scanning electron microscopy (FE-SEM, Hitachi 4800, Japan) and energy-dispersive X-ray spectroscopy (EDX, Oxford ISIS 310, England). The potentiodynamic polarization and AC impedance tests for electrochemical degradations were carried out in 0.9% NaCl solution at similar body temperature using a potentiostat with a scan rate of 1.67mV/s and potential range from -1500mV to + 2000mV.

  • PDF