• Title/Summary/Keyword: Scaling center

Search Result 249, Processing Time 0.03 seconds

A Study on Geotechnical Centrifuge Testing Method for Seismic Performance Evaluation of Large Embankment Dams (대형 댐의 지진응답특성평가를 위한 원심모형시험 기법 연구)

  • Kim, Nam-Ryong;Lim, Jeong-Yeul;Im, Eun-Sang
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.201-209
    • /
    • 2016
  • Damages of large embankment dams by recent strong earthquakes in the world highlight the importance of seismic security of dams. Some of recent dam construction projects for water storage and hydropower are located in highly seismic zone, hence the seismic performance evaluation is an important issue. While state-of-the-art numerical analysis technology is generally utilized in practice for seismic performance evaluation of large dams, physical modeling is also carried out where new construction technology is involved or numerical analysis technology cannot simulate the behavior appropriately. Geotechnical centrifuge modeling is widely adopted in earthquake engineering to simulate the seismic behavior of large earth structures, but sometimes it can't be applied for large embankment dams due to various limitations. This study proposes a dynamic centrifuge testing method for large embankment dams and evaluated its applicability. Scaling relations for a case which model scale and g-level are different could be derived considering the stress conditions and predominant period of the structure, which is equivalent to previously suggested scaling relations. The scaling principles and testing method could be verified by modified modeling of models using a model at different acceleration levels. Finally, its applicability was examined by centrifuge tests for an embankment dam in Korea.

Comparison of the estimated breeding value and accuracy by imputation reference Beadchip platform and scaling factor of the genomic relationship matrix in Hanwoo cattle

  • Soo Hyun, Lee;Chang Gwon, Dang;Mina, Park;Seung Soo, Lee;Young Chang, Lee;Jae Gu, Lee;Hyuk Kee, Chang;Ho Baek, Yoon;Chung-il, Cho;Sang Hong, Lee;Tae Jeong, Choi
    • Korean Journal of Agricultural Science
    • /
    • v.49 no.3
    • /
    • pp.431-440
    • /
    • 2022
  • Hanwoo cattle are a unique and historical breed in Korea that have been genetically improved and maintained by the national evaluation and selection system. The aim of this study was to provide information that can help improve the accuracy of the estimated breeding values in Hanwoo cattle by showing the difference between the imputation reference chip platforms of genomic data and the scaling factor of the genetic relationship matrix (GRM). In this study, nine sets of data were compared that consisted of 3 reference platforms each with 3 different scaling factors (-0.5, 0 and 0.5). The evaluation was performed using MTG2.0 with nine different GRMs for the same number of genotyped animals, pedigree, and phenotype data. A five multi-trait model was used for the evaluation in this study which is the same model used in the national evaluation system. Our results show that the Hanwoo custom v1 platform is the best option for all traits, providing a mean accuracy improvement by 0.1 - 0.3%. In the case of the scaling factor, regardless of the imputation chip platform, a setting of -1 resulted in a better accuracy increased by 0.5 to 1.6% compared to the other scaling factors. In conclusion, this study revealed that Hanwoo custom v1 used as the imputation reference chip platform and a scaling factor of -0.5 can improve the accuracy of the estimated breeding value in the Hanwoo population. This information could help to improve the current evaluation system.

A Study on the absorbed dose to water for high energy electron beams using Water equivalency of plastic phantom (고 에너지 전자선에서 물등가 고체팬톰을 이용한 물 흡수선량 측정에 관한 연구)

  • Sin, Dong-Ho;Sin, Dong-Oh;Kim, Sung-Hoon;Park, Sung-Yong;Ji, Young-Hoon;Ahn, Hee-Kyung;Kang, Jin-Oh;Hong, Seong-Eon
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.166-169
    • /
    • 2004
  • In the International Code of Practice for dosimetry TRS-398 published by International Atomic Energy Agency(IAEA), water equivalency plastic phantom may be used under certain circumstances for electron beam dosimetry for beam quality E0${\leq}$ 10 MeV. In this study, Palstic Water$^{TM}$ and Virtual Water$^{TM}$ were evaluated in order to determine fluence scaling factor hpl. Plastic phantom was evaluated for five electron energy from 6 MeV to 20 MeV. From the measured data of Palstic Water$^{TM}$, the fluence scaling factor hpl was found to be average 0.9964 and Virtual Water$^{TM}$ fluence scaling factor was 1.0156.

  • PDF

Estimation and Mapping of Methane Emission from Rice Paddies in Gyunggi-do Using the Modified Water Management Scaling Factor (수정된 물관리보정인자를 적용한 경기도 논에서의 메탄 배출량 산정과 지도화)

  • Choi, Sung-Won;Kim, Hakyoung;Kim, Yeonuk;Kang, Minseok;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.18 no.4
    • /
    • pp.320-326
    • /
    • 2016
  • From the perspective of climate-smart agriculture, it is becoming more critical to accurately estimate the amount of greenhouse gas emissions in the agricultural sector. In order to accurately ascertain the methane emissions from rice paddies, which account for a significant portion of the emission from the agricultural sector, we used the data from the 2010 Agriculture, Forestry and Fisheries Census, the revised water management scaling factors and their calculation program. In order to facilitate the analyses and understanding, the results were mapped using the ArcGIS software. The fact that the validation of the mapped values against the actual field measurements at one site showed little difference encourages the necessity to further this study. The administrative districts-based map of methane emission can help clearly identify the regional differences. Furthermore, the analysis of their major controlling factors will provide important scientific basis for the practical policy makings for methane mitigation.

Scaling predictions in seawater reverse osmosis desalination

  • Hchaichi, Houda;Siwar, Saanoun;Elfil, Hamza;Hannachi, Ahmed
    • Membrane and Water Treatment
    • /
    • v.5 no.3
    • /
    • pp.221-233
    • /
    • 2014
  • Simulations were conducted to predict supersaturation along Reverse Osmosis (RO) modules for seawater desalination. The modeling approach is based on the use of conservation principles and chemical equilibria equations along RO modules. Full Pitzer ion interactive forces model for concentrated solutions was implement to calculate activity coefficients. An average rejection rate for all ionic species was considered. Supersaturation has been used to assess scaling. Supersaturations with respect to all calcium carbonate forms and calcium sulfate were calculated up to 50% recovery rate in seawater RO desalination. The results for four different seawater qualities are shown. The predictions were in a good agreement with the experimental results.

Mixed-state Hall effect of $MgB_2$ thin films ($MgB_2$박막의 혼합상태에서의 홀 효과)

  • Kim, Bo-Yeon;Jung, Soon-Gil;Moon, Kyeong-Hee;Kang, W.N.;Choi, Eun-Mi;Kim, Heon-Jung;Lee, Sung-Ik;Kim, Hyeong-Jin
    • Progress in Superconductivity
    • /
    • v.7 no.2
    • /
    • pp.103-108
    • /
    • 2006
  • We have measured the Hall resistivity (${\rho}_{xy}$) and the longitudinal resistivity (${\rho}_{xy}$) on superconducting $MgB_2$ thin films in extended fields up to 18 T. We found a universal scaling behavior between the Hall resistivity and the longitudinal resistivity, which is independent of the temperature and the magnetic field. At a wide magnetic field region from 1 to 18T, a universal power law of ${\beta}=2.0{\pm}0.1$ in a scaling relation, ${\rho}_{xy}={A{\rho}_{xx}}^{\beta}$, was observed in c-axis-oriented $MgB_2$ thin films. These results can be well interpreted by using recent models.

  • PDF

Characteristics of Source Acupoints: Data Mining of Clinical Trials Database (데이터 마이닝을 이용한 임상연구 데이터베이스 기반 원혈의 주치 특성)

  • Choi, Dha-Hyun;Lee, Seoyoung;Lee, In-Seon;Ryu, Yeonhee;Chae, Younbyoung
    • Korean Journal of Acupuncture
    • /
    • v.38 no.2
    • /
    • pp.100-109
    • /
    • 2021
  • Objectives : Source acupoint is one of the representative acupoints to treat various diseases in each meridian. We aimed to identify the patterns of selection of Source acupoints and their associations with diseases using clinical trials data. Methods : We extracted the frequency of Source acupoints across 30 diseases from clinical trials database. Acupuncture treatment regimens were retrieved from the Cochrane Database of Systematic Reviews. The frequency of Source acupoint use was calculated as the number of studies using a certain acupoint divided by the total number of included studies. Using hierarchical clustering and multidimensional scaling, the characteristics of Source acupoints were analyzed based on the similarity of the relationships between the Source acupoints and the diseases. Results : A total of 421 clinical trials were included for this analysis. LR3, HT7, KI3, and LI4 acupoints were most frequently used for the treatment of 30 diseases. Cluster analysis showed that LR3 and LI4 acupoints were grouped together and HT7 and KI3 acupoints were grouped together. Multidimensional scaling revealed that LR3, LI4, HT7, and KI3 acupoints have intrinsic properties in the two-dimensional space. Conclusions : The present study identified the selection patterns of the Source acupoints using clinical trials data. Our finding will provide the understanding of the characteristics of Source acupoints.

Unusual Enhancements of NmF2 in Anyang Ionosonde Data

  • Yun, Jongyeon;Kim, Yong Ha;Kim, Eojin;Kwak, Young-Sil;Hong, Sunhak
    • Journal of Astronomy and Space Sciences
    • /
    • v.30 no.4
    • /
    • pp.223-230
    • /
    • 2013
  • Sudden enhancements of daytime NmF2 appeared in Anyang ionosonde data during summer seasons in 2006-2007. In order to investigate the causes of this unusual enhancement, we compared Anyang NmF2's with the total electron contents (GPS TECs) observed at Daejeon, and also with ionosonde data at at mid-latitude stations. First, we found no similar increase in Daejeon GPS TEC when the sudden enhancements of Anyang NmF2 occurred. Second, we investigated NmF2's observed at other ionosonde stations that use the same ionosonde model and auto-scaling program as the Anyang ionosonde. We found similar enhancements of NmF2 at these ionosonde stations. Moreover, the analysis of ionograms from Athens and Rome showed that there were sporadic-E layers with high electron density during the enhancements in NmF2. The auto-scaling program (ARTIST 4.5) used seems to recognize sporadic-E layer echoes as a F2 layer trace, resulting in the erroneous critical frequency of F2 layer (foF2). Other versions of the ARTIST scaling program also seem to produce similar erroneous results. Therefore we conclude that the sudden enhancements of NmF2 in Anyang data were due to the misrecognition of sporadic-E echoes as a F-layer by the auto-scaling program. We also noticed that although the scaling program flagged confidence level (C-level) of an ionogram as uncertain when a sporadic-E layer occurs, it still automatically computed erroneous foF2's. Therefore one should check the confidence level before using long term ionosonde data that were produced by an auto-scaling program.

하악 매복지치의 예방적 발거 후 구취의 평가

  • Sim, Jeong-Hwan;Kim, Yeong-Gyun;Choe, Yong-Geun
    • The Journal of the Korean dental association
    • /
    • v.41 no.1 s.404
    • /
    • pp.42-47
    • /
    • 2003
  • Dental professions recommend that mandibular impacted third molar be extracted for the prevention of osteomyelities crneoplasm or for the treatment of halitosis. Even the possibility of emergence of unexpected halitosis after the preventive extraction exists, there are few studies describing the unexpected halitosis. This study intended to measure the emergence of halitosis after extraction of mandibular impacted third molar. Thirty-eight patients who visited Daejin Medical Center participated in this study. Halitosis was objectively measured using Halimeter in 3 intervals-before, after I day, after 7 days. Third factors, scaling and gender, which may influence the halitosis were analyzed with stratification. This study finds that in general halitosis decreased after 1 day but increased after 7 days. Scaling was helpful in decreasing halitosis and women have less severe halitosis than men. The effects of time interval(p<0.05), gender(p=0.836), and scaling(p=0.7929) on the severity of halitosis were not statistically significant. However, since this study's patients are neither a representative sample nor a random sample, all data interpretation was focused on clinical significance instead of conventional statistical significance. Clinical significance of this study's findings are: 1) scaling should be conducted in advance, 2) men should be notified of the higher possibility of halitosis.

  • PDF