• Title/Summary/Keyword: Scaler Tip

Search Result 26, Processing Time 0.026 seconds

Morphological aspect of the attached bacteria by the sterilization method of the ultrasonic scaling tip (소독멸균 방법에 따른 초음파 스케일링 팁에 부착된 세균의 양상)

  • Nam, Seoul-Hee;Kim, Yu-rin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.15 no.4
    • /
    • pp.713-718
    • /
    • 2015
  • Objectives: The purpose of the study was to investigate the bacterial morphology attached on ultrasonic scaler tips using no cleansing solution, alcohol cotton, liquid chemical disinfecting agent, and autoclave method. Methods: Scaling tip was applied to the mouth and the ultrasonic scaler tips were assigned to four groups. Group 1 was control group with no cleansing solution. Group 2 was treated with alcohol cotton. Group 3 was treated with 2% green Y-Na solution in liquid chemical disinfecting agent, and Group 4 was sterilized by autoclave method. Live bacteria were observed by phase contrast microscopy. The scanning electron microscopy(SEM) revealed the morphological characteristics of scaler surface. The type of attached bacteria were analyzed using SPSS 21.0 program. The data were analyzed by one-way analysis of variance(ANOVA) and Tukey's post-hoc test. Results: The types of sterilization methods had influences on the bacterial viability. The numbers of cocci, bacilli, spiral form bacteria, and filamentous bacteria was observed in $89.00{\pm}3.60%$, $29.67{\pm}3.51%$, $3.33{\pm}0.57%$ and $1.67{\pm}0.57%$ in control group, $31.67{\pm}3.51%$, $63.33{\pm}4.04%$, $2.00{\pm}1.00%$ and $1.67{\pm}0.57%$ in alcohol cotton group, $69.67{\pm}4.50%$, $12.33{\pm}2.51%$, 0% and 0% in liquid chemical disinfecting agent group, and 0.0%, 0.0%, 0.0% and 0.0% in autoclave method group. The clean surface of ultrasonic scaler tip was shown on SEM by autoclave method. Conclusions: The most effective sterilization method of ultrasonic scaler tip was the autoclave method. Autoclave method is the most effective sterilization method and can reduce the cross-infection in the dental clinic.

The Effect of a Piezoelectric Ultrasonic Scaler with Curette Tip on Root Substitute Removal in Vitro (큐렛형 팁을 장착한 압전방식 초음파 치석제거기가 치근대체물 삭제에 미치는 영향)

  • Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.2
    • /
    • pp.429-442
    • /
    • 2000
  • Based on current evidence in the literature, it is known that endotoxin is a weakly adherent surface phenomenon and that power-driven instruments can be used to accomplish definitive root detoxification and maximal wound healing without overinstrumentation of root and without extensive cementum removal. And one of the newly developed curette tips used with low power of piezoelectric ultrasonic scaler, is effective to remove calculus and not to remove the excessive cementum. The purpose of this study is therefore, to assess the influence of ultrasonic power and various working parameters on root substitute removal when instrumentation is performed with the curette tip on piezoelectric ultrasonic scaler. This study assessed defect depth, width and area resulting from instrumentation using a piezoelectric ultrasonic scaler with a curette type tip in vitro to acrylic resin block as a root substitute. The working parameters was standardized by the sledge device which controls lateral force(0.5 N, 1 N, 2 N) and instrumentation time(5 sec, 10 sec, 20 sec) and power setting was adjusted 0,2,4,8 in P mode. Power setting had the greatest influence on defect depth compared to lateral force and instrumentation time(standardized regression parameter estimates${\pm}$standard error, $0.37{\pm}0.02$, $0.19{\pm}0.02$, $0.07{\pm}0.02$). The effects on defect area also greatest for power setting($0.57{\pm}0.03$) compared to lateral force and instrumentation time($0.33{\pm}0.03$, $0.12{\pm}0.03$). The effect of the power setting on the defect width($0.15{\pm}0.01$) is not so great as defect depth or defect area compared to lateral force($0.12{\pm}0.01$) and effect of instrumentation time is minimal($0.02{\pm}0.01$). It could be concluded that the power setting has the greatest influence on the defect depth and area in curette type tip with low power of piezoelectric ultrasonic device. Many parameters can be adjusted in various situation in clinical use of piezoelectric ultrasonic scaler but the power setting is the first parameter to be adjusted.

  • PDF

The Effect of a Piezoelectric Ultrasonic Scaler with Curette Tip on Casting Gold Removal in Vitro (큐렛팁을 장착한 압전방식 초음파치석제거기의 작업조건에 따른 치과주조용 합금의 삭제에 관한 연구)

  • Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.3
    • /
    • pp.531-542
    • /
    • 2001
  • Periodontal debridement is most important procedure in periodontal treatment, because periodontal disease is the biofilm infection. The use of ultrasonic instrument has many clinical advantages compared to classical hand instrument. The introduction of newly developed ultrasonic scaler tips made the use of ultrasonic scaler popular. However the study of tooth substance removal according to the working parameters of ultrasonic scaler with newly developed tips is not sufficient. The purpose of this study is to evaluate the effects of working parameters of piezoelectric ultrasonic scaler with curette tip on casting gold removal. The working parameters was standardized by the sledge device which controls lateral force(0.5 N, 1.0 N, 2.0 N) and power setting was adjusted 2, 4, 8 in P mode and S mode and instrumentation time was 5 seconds. The defect depth and width were measured with profile meter and defect surface was examined by SME. The depth of defect was significantly large in S mode( $39.58{\pm}19.35{\mu}m$) compared to P mode( $8.37{\pm}6.98{\mu}m$). There was significant decrease of depth of defect between 1.0N($32.87{\pm}27.18{\mu}m$) and 2.0N( $14.86{\pm}15.04{\mu}m$). The area of defect was also significantly large in S mode($4482.42{\pm}3551.71{\mu}m^2$) compared to P mode( $922.06{\pm}960.32{\mu}m^2$). There was significant decrease of area of defect between 1.0N($3889.12{\pm}3936.00{\mu}m$) and 2.0N( $974.66{\pm}986.01{\mu}m$). The change of mode did not effect on the width of the defect. The change of power setting did not effect on the depth, width, and area of defect. In spite of limitation of this study it could be concluded that the use of piezoelectric ultrasonic scaler with curette tip on S mode could make significant tooth substance loss.

  • PDF

Comparative evaluation of roughness of titanium surfaces treated by different hygiene instruments

  • Unursaikhan, Otgonbayar;Lee, Jung-Seok;Cha, Jae-Kook;Park, Jung-Chul;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.3
    • /
    • pp.88-94
    • /
    • 2012
  • Purpose: The use of appropriate instruments to clean surfaces with minimal change, is critical for the successful maintenance of a dental implant. However, there is no consensus about the type and methodology for such instruments. The aim of this study was to characterize changes in the roughness of titanium surfaces treated by various scaling instruments. Methods: Thirty-seven identical disks (5 mm in diameter) were investigated in this study. The specimens were divided into eight groups according to the types of instrumentation and the angle of application. Ultrasonic scaling systems were applied on a titanium disk to simulate standard clinical conditions. The equipment included a piezoelectric ultrasonic scaler with a newly developed metallic tip (NS group), a piezoelectric ultrasonic scaler with a conventional tip (CS group), a piezoelectric root planer ultrasonic scaler with a conventional tip (PR group), and a plastic hand curette (PH group). In addition, the sites treated using piezoelectric ultrasonic scaler systems were divided two sub-groups: 15 and 45 degrees. The treated titanium surfaces were observed by scanning electron microscopy (SEM), and the average surface roughness (Ra) and mean roughness profile depth (Rz) were measured with a profilometer. Results: SEM no significant changes in the titanium surfaces in the NS group, regardless of the angle of application. The PH group also showed no marked changes to the titanium surface, although some smoothening was observed. All CS and PR sites lost their original texture and showed irregular surfaces in SEM analysis. The profilometer analysis demonstrated that the roughness values (Ra and Rz) of the titanium surfaces increased in all, except the PH and NS groups, which showed roughness decreases relative to the untreated control group. The Ra value differed significantly between the NS and PR groups (P<0.05). Conclusions: The results of this study indicated that changes in or damage to titanium surfaces might be more affected by the hardness of the scaler tip than by the application method. Within the limitations of this study, the newly developed metallic scaler tip might be especially suitable for peri-implant surface decontamination, due to its limited effects on the titanium surface.

Computer Aided Engineering Design of Power Injection Molding Process for Dental Scaler Top Mold Design

  • Hwang, C.J.;Ko, Y.B.;Park, H.P.;Chung, S.T.;Rhee, B.O.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.497-498
    • /
    • 2006
  • Powder Injection Molding (PIM) has recently been recognized as an advanced manufacturing technology for low-cost mass production of metal or ceramic parts of complicated geometry. With this regards, design technology of dental scaler tip PIM mold, which has complex shape, with the help of computer-aided analysis for powder injection molding process was developed. Compter aided analysis results, such as filling pattern, weldline formation, and air vent position prediction were investigated and eventually showed good agreements with experimental results.

  • PDF

Root surface roughness following mechanical instrumentation, in vitro 3 dimensional planimetric study (기구조작후 치근표면의 조도에 관한 연구; 3차원 측정기틀 이용한 in vitro 연구)

  • Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.4
    • /
    • pp.823-828
    • /
    • 1998
  • A primary goal of periodontal therapy is the creation of root surfaces that are free of plaque and calculus. It is not yet to be determined whether it is desirable to have a smooth root surface after treatment. It is also not clear what degree of roughness result from different instruments. In the present study various instruments for root surface debridement were evaluated. 20 extracted teeth were utilized, and the teeth were treated with one of the following instrument: Gracey curette, Perio Clean, and piezo ultrasonic device(Setlec, P Max) with general scaler tip, curette-like tip, and diamond tip. 3 dimensional planimetric device(Accura) was used to evaluate the average surface roughness. It was demonstrated hand and power-driven instruments did not have a significant difference in roughness of the root surface following instrumentation. And ultrasonic scaler tip tended to make a most smooth surface than other instruments. The possible reasons of the result were discussed.

  • PDF

Effect of various types of dental magnetostrictive ultrasonic scaler tip on surface characteristics of titanium (여러가지 치과용 자기변형 초음파 스케일러 팁이 티타늄 표면특성에 미치는 영향)

  • Min-Cheol Yang;Seok-Hwan Jeong;Seol Kim;Seung-Hwan Seol;Seung-Kyu Lee;Sang-Joun Yu;Byung-Ock Kim
    • Journal of the Korean institute of surface engineering
    • /
    • v.57 no.4
    • /
    • pp.296-305
    • /
    • 2024
  • The aim of this in vitro study was to evaluate the changes in the roughness and weight of titanium discs treated with 3 different types of magnetostrictive ultrasonic scaler tip. Eighty identical disks (10 mm in diameter), 50 for surface roughness and 30 for weight change, were investigated in this study. For this study, 3 types of scaler tip were used as follows; Powerline(FSI-PWR-1000), Slimline(FSI-SLI-1000), and Thinsert(-16 00037374). The power was set to high power(HP), medium power(MP), and low power(LP), in the blue zone recommended by the manufacturer. Surface topography analysis was carried out using scanning electron microscopy (SEM). Surface roughness measurements, the average surface roughness (Ra) and mean roughness profile depth (Rz), were compared between treated and non-treated surfaces with a profilometer. A PowerLINE-MP of magnetostrictive ultrasonic scalers for implant patients might be recommended when considering changes in the roughness and weight of titanium discs.

The effect of copper alloy scaler tip on the surface roughness of dental implant and restorative materials (구리 합금 초음파 스케일러 팁이 치과 임플란트 및 수복 재료 표면에 미치는 영향)

  • Lee, Ah-Reum;Chung, Chung-Hoon;Jung, Gyu-Un;Pang, Eun-Kyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.177-185
    • /
    • 2014
  • Purpose: This study is designed to investigate the various impacts of different types of scaler tips such as cooper alloy base tip and the others on the surface roughness of teeth and implant by the method which is currently in clinical use. Materials and methods: Four different types of disc shaped porcelain, titanium, zirconia, and Type III gold alloy dental materials sized 15 mm diameter, 1.5 mm thickness were used for the experiment. Plastic hand curette (Group PS), cooper alloy new tip (Group IS), and stainless steel tip (Group SS) were used as testing appliances. A total of 64 specimens were used for this study; Four specimens for each material and appliance group. Surface roughness was formed with 15 degree angle in ultrasonic scaler tip and with 45 degree angle in hand curette of instrument tip and the specimen surface with 5 mm long, one horizontal-reciprocating motion per second for 30 seconds by 40 g force. To survey the surface roughness of each specimen, a field emission scanning electron microscope, an atomic force microscope, and a surface profiler were used. (Ra, ${\mu}m$). Results: According to SEM, most increased surface roughness was observed in SS group while IS groups had minimal roughness change. Measurement by atomic force microscope presented that the surface roughness of SS group was significantly greater than those of PS, IS and control groups in the type III gold alloy group (P<.05). IS group showed lesser surface roughness changes compared to SS group in porcelain and gold alloy group (P<.05). According to surface profiler, surface roughness of SS group showed greater than those of PS, IS and control groups and IS group showed lesser than those of SS group in all specimen groups. Type III gold alloy group had large changes on surface roughness than those of porcelain, titanium, zirconia (P<.05). Conclusion: The result of this study showed that newly developed copper alloy scaler tip can cause minimal roughness impacts on the surface of implant and dental materials; therefore this may be a useful alternative for prophylaxis of implant and restored teeth.

Cytotoxicity(MTT) evaluation of dental instruments made of polymers (치과용 폴리머 기구의 세포독성(MTT) 평가)

  • Choi, Eun-Mi
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.8
    • /
    • pp.187-195
    • /
    • 2021
  • In order to assess the cell toxicity of 10 instruments made of polymers, the MTT assay which utilizes the L-929 cell was selected. Specimens were eluted at a temperature of 37℃ for 24 hours at a rate of 4g per 20mL, RPMI 1640, and then was positively and negatively contrasted with a control test solution, in accordance with the Notification No. 2020-12 Protocols of Medical Apparatus Biological Safety from the Ministry of Drug and Food Safety. As a result of 24 hours of incubation in 37℃, 5% CO2 Incubator and assessment using an ELISA reader, the results of Intraoral camera indiciated a cellular viability of more than 70% at a 50% eluate. But, the Plastic impression tray, 3D printing tweezer, Impression disposable syringe, Dental floss holder, Hand implant scaler, Surgical retractor, Oral scanner tip, Dental mirror, and the Water pick tip all reported a cellular viability of more than 70% at a 100% eluate, which indicates that do not exhibit cytotoxicity, thus allowing it to be used in contact with the mucous membrane of the oral cavity.

A Study on Temperature Changes during Bone Scaling and Cutting of Dental Ultrasonic Scaling/Surgery System (치과용 초음파 스케일러/수술기 통합 시스템의 스케일링 및 절삭 시 온도 변화에 관한 연구)

  • Sa, Min-Woo;Ko, Tae-Jo;Kim, Jong Young
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.2
    • /
    • pp.1-8
    • /
    • 2020
  • While dental clinics still use the ultrasonic scaling/surgery tool for teeth scaling and cleaning the tool's use is expanding steadily to include treatment of damaged teeth and bone tissue. In this study, a handpiece moving system (HMS) was developed to evaluate bone scaling and cutting in the field of dentistry. The HMS, through a scaling test of bone using a scaler tip, it was able to identify surface damage. Additionally, a thermos-graphic camera was used to observe the temperature distribution that occurred during the bone scaling and cutting process. Consequently, we found that increasing the working load increased the amount of surface damage. Changes in temperature distribution occurred slowly and were maintained within safety bounds for 10 minutes. Going forward, we will compare the HMS performance on scaling and cutting with other devices.