• Title/Summary/Keyword: Scaled distance

Search Result 113, Processing Time 0.031 seconds

A Study on the Behavior of a Closely-spaced Tunnel by Using Particle Flow Code (입자 유동 해석(PFC)을 통한 근접터널의 거동에 관한 연구)

  • Suh, Byung-Wook;Jo, Seon-Ah;Jung, Seon-Ah;Lee, Seok-Won
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.159-169
    • /
    • 2008
  • In general, it is considered that a pillar between closely-spaced tunnel is sensitive for stress concentration. Stability of a pillar is key factor for excavation of closely-spaced tunnel. In this paper, the study is focused on tracing the behaviors, displacement and plotting damages around tunnels that is modelled with Particle Flow Code, $PFC^{2D}$. Parametric study was performed with changing distance between center of tunnels and coefficient of earth pressure(K). Scaled-model tests were also carried out to validate a numerical analysis model. It was found that $PFC^{2D}$ could show dynamic visualized result in quite good agreement with the experimental test.

  • PDF

The Mach-scale Performance Test of Next-Generation Blade(NRSB- 1M/2M) (차세대 블레이드(NRSB-1M/2M)의 마하 스케일 성능시험)

  • Song, Geun-Ung;Kim, Jun-Ho;Kim, Seung-Ho
    • Aerospace Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.27-36
    • /
    • 2006
  • This paper describes the performance test procedures and results of NRSB-1M and NRSB-2M Not only aerodynamic performance test but also sound measurement test were performed for the small-scaled blades in the ground Total thrusts and torques of the rotor were measured using rotating balance for aerodynamic performance test. Sound pressure levels were measured using microphone in 1.64D distance for sound measurement test. Non-dimensionalized test data are compared and analyzed. Consequently, It was confirmed that NRSB-2 was better than NRSB-1.

  • PDF

Analysis of Excluded Volume Effect in Theta Solvent Systems of Polymethyl Methacrylate and Polystyrene by Means of a Modified Scaled Temperature Parameter

  • Kim, Myeong Ju;Park, Il Hyeon
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.11
    • /
    • pp.1255-1260
    • /
    • 2001
  • The expansion of two different kinds of hydrodynamic size of polymethyl methacrylate (PMMA Mw: 1.56- 2.04 ${\times}$ 106 g/mol) has been measured by dynamic light scattering and viscometry above the Flory $\theta$ temperature of the variou s solvents such as n-butyl chloride, 3-heptanone, and 4-heptanone. The expansion of PMMA chains was analyzed in terms of universal temperature parameters and also compared with previous results of polystyrene (PS) system. First it was found that simple $\tau/{\tau}c$ parameter no longer had its universality for the expansion behavior of hydrodynamic size in the chemically different linear polymer chains. However after modifying ${\tau}/{\tau}c$ parameter into $(Mw/Ro2)3}2(\tau/\tauc)$, we observed a much better universality for both PMMA and PS systems. Here Mw, Ro, $\tau[=(T-{\theta}$)/${\theta}$]$, and ${\tau}c[=({\theta}-Tc)/Tc]$ are defined as the weight average molecular weight, the unperturbed end-to-end distance, the reduced temperature and the reduced critical temperature, respectively.

Evaporation Characteristics of Paired Sessile Droplets on a Heated Substrate (가열된 표면에 고착된 한 쌍의 액적 증발 특성)

  • Hyung Ju Lee;Won Yeong Hwang;Jing Hao Jin;Chang Kyoung Choi;Seong Hyuk Lee
    • Journal of ILASS-Korea
    • /
    • v.28 no.3
    • /
    • pp.113-118
    • /
    • 2023
  • This study investigates the evaporation characteristics of paired sessile droplets on a heated substrate. In particular, the evaporation time and contact line behaviors were analyzed based on the droplet-to-droplet distance and substrate temperature. The contact line behavior and volume variations were visualized using the shadowgraph method. It was observed that the contact diameter and contact angle exhibited similar behavior for both single and paired droplets regardless of the droplet-to-droplet distance and substrate temperature. The paired droplets demonstrated a longer evaporation time than the single droplet due to the vapor accumulation between the droplets. Furthermore, the scaled lifetime, defined as the ratio of evaporation time between paired and single droplets, increased as the droplet-to-droplet distance decreased and decreased as the substrate temperature increased, attributed natural convection.

Interactions between pre-existing large pipelines and a new tunnel (기존 대구경 파이프라인과 신설터널간의 상호작용)

  • Jeong, Sun-Ah;Choi, Jung-In;Hong, Eun-Soo;Chun, Youn-Chul;Lee, Seok-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.11 no.2
    • /
    • pp.175-188
    • /
    • 2009
  • When a new tunnel is excavated by the drill and blast method near pre-existing underground structures or tunnels due to the region restricted condition such as urban area, the ground will be relaxed by the excavation. In this case, issues can be created in terms of stability of pre-existing underground structures. One of major factors determining the stability of pre-existing underground structures can be a separation distance between pre-existing underground structures and a newly excavated tunnel. The region of ground relaxation defined by the plastic zone due to new excavation can be varied by separation distance. In this study, in other to estimate an influence of new tunnel excavation in terms of separation distance on the stability of pre-existing large pipelines, two-dimensional scaled model tests using plaster were performed for six models which have a different separation distance, The results show that based on the analysis of induced displacement during tunnel construction, the displacement decreases as the separation distance between large pipeline and new tunnel is increased until the distance is 2.5 times of pipeline diameter. Beyond this point, however, the displacement has become stabilized.

Hydrodynamic coupling distance between a falling sphere and downstream wall

  • Lin, Cheng-Chuan;Huang, Hung-Tien;Yang, Fu-Ling
    • Coupled systems mechanics
    • /
    • v.7 no.4
    • /
    • pp.407-420
    • /
    • 2018
  • In solid-liquid two phase flow, the knowledge of how descending solid particles affected by the presence of downstream wall is important. This work studies at what interstitial distance the velocity of a vertically descending sphere is affected by a downstream wall as a consequence of wall-modified hydrodynamic forces through a validated dynamic model. This interstitial distance-the hydrodynamic coupling distance ${\delta}_c-is$ found to decay monotonically with the approach Stokes number St which compares the particle inertia to viscous drag characterized by the quasi-steady Stokes' drag. The scaling relation ${\delta}_c-St-1$ decays monotonically as literature below the value of St equal to 10. However, the faster diminishing rate is found above the threshold value from St=10-40. Furthermore, an empirical relation of ${\delta}_c-St$ shows dependence on the drop height which clearly indicates the non-negligible effect of unsteady hydrodynamic force components, namely the added mass force and the history force. Finally, we attempt a fitting relation which embedded the particle acceleration effect in the dependence of fitting constants on the diameter-scaled drop height.

Estimation of Optimum Pile length Using Various Prediction (다양한 예측기법을 이용한 현장타설말뚝의 최적길이 산정)

  • Choi, Young-Seok;Iim, Hyung-Joon;Song, Myung-Jun;Jang, Hak-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.700-707
    • /
    • 2008
  • As plan connecting island to island or island to land is needed, a lot of long-span bridge is being designed lately in Southern part of Korea. With development of pile equipment, overhanging large-scaled concrete pile are adopted to foundation type of main tower or pylon. About the number of 15~30 group piles per tower foundation is designed to resist long-spaning super-structure load, but by restricted condition of site investigation cost, a few boring-hole tests are performed to identify sub-ground layers. Up to now, direct-curved method connecting two or three known boring logs and representative interval method are usually used to evaluate unknown depth and rock properties at locations where piles are constructed. Because this approach is not logical and so rough, much difference occurs between designed length of piles and real length of it. In this paper, using a lot of various prediction method(reciprocal distance method, inverse square distance method and kriging method etc.), we suggest optimum length of group piles.

  • PDF

Scaled Model Study on the Underground Mise-à-la-masse Method (갱도(坑道)를 이용(利用)한 인공분극법(人工分極法) 모형(模型) 연구(硏究))

  • Suh, Baek-Soo;Song, Young-Soo
    • Journal of Industrial Technology
    • /
    • v.5
    • /
    • pp.81-89
    • /
    • 1985
  • A Mise-$\grave{a}$-la-masse method is to use a subsurface conductive mass itself as one current electrode of a pair by connecting it directly to one pole of a voltage source, the second current electrode being placed on the ground surface at a great distance and connected to the other pole. This paper is to study the modified Mise-$\grave{a}$-la-masse method using a water tank, that is, the second current electrode is placed on the underground level instead of being placed at a great distance, to find the geometry and the continuity of ore bodies.

  • PDF

A Study on Safety Blasting Design with Blast Vibration Analysis Urban Area (도심지 미진동 제어 발파에서 진동분석을 통한 안전발파설계에 관한 연구)

  • 안명석;박종남;배상근
    • Explosives and Blasting
    • /
    • v.17 no.2
    • /
    • pp.36-44
    • /
    • 1999
  • A study was made on the design of the prediction model concerning blasting vibration in a constraction site, Namgu, Daegu City. The geology in this area consists of hornfels of shale and mud underlain by quartize, of which the main strike of the geological structure is NW direction. Measurements were carried out on the top of the wall concrete water storage tank, which is burried in the ground earth. The attenuation due to the vertical wall of the concrete structure may be experted because of spherical divergency at the bottom corner of the wall by the Huygens principle. For design of blasting prediction model, thus among scaled distance(SD) may be preferable to use in the regression model, since they represents most likely the average ground condition. Judging from the regression results, the cube root method may be more suitable for this area. The SD values for the maximum allowable vibration velocity of 0.5 cm/s, in this area are 22.5, 28.0 and 30.6 for the significance level of 50%, 95% and 99%, respectively.

  • PDF

A Study on the Development for Prediction Model of Blasting Noise and Vibration During Construction in Urban Area (도시지역 공사 시 발파 소음·진동 예측식 개발에 관한 연구)

  • Jinuk Kwon;Naehyun Lee;Jeongha Woo
    • Journal of Environmental Impact Assessment
    • /
    • v.33 no.2
    • /
    • pp.84-98
    • /
    • 2024
  • This study proposed a prediction equation for the estimation of blasting vibaration and blasting noise, utilizing 320 datasets for the blasting vibration and blasting noise acquired during urban blasting works in the Incheon, Suwon, Wonju, and Yangsan regions. The proposed blasting vibration prediction equation, derived from regression analysis, indicated correlation coefficients of 0.879 and 0.890 for SRSD and CRSD, respectively, with an R2 value exceeding 0.7. In the case of the blasting noise prediction equation, stepwise regression analysis yielded a correlation coefficient of 0.911 between the prediction values and real measurements for the blasting nosie, and further analysis to determine the constant value revealed a correlation coefficient of 0.881, with an R2 value also exceeding 0.7. These results suggest the feasibility of applying the proposed prediction equations when environmental impact assessments or education environment evaluation according to urban development or apartment construction projects is performed.