• Title/Summary/Keyword: Scale for Ventilation Efficiency3

Search Result 15, Processing Time 0.027 seconds

Analysis on ventilation efficiency by CFD simulation for breathing zone in bed room (CFD해석에 의한 침실 호흡역의 환기효율 분석)

  • Yoo, Bok-Hee;Yoon, Chung-Sook
    • KIEAE Journal
    • /
    • v.2 no.3
    • /
    • pp.11-16
    • /
    • 2002
  • Indoor air environment is one of the most important factors that affect resident's health and comfort level. In this paper, the influence of ventilation efficiency with different types of furniture arrangement at breathing zone in a room was analyzed by numerical simulation based on computational fluid dynamics(CFD). The furniture layout of students' bedroom have been classified by three different patterns so that SVE3(scale for ventilation efficiency3) in the rooms was analyzed for air flow distribution. According to the results of the study, SVE3 has the maximum value in spaces between furnitures and each comer of the room. The furniture arrangement influences the ventilation efficiency. It was con finned that ventilation effective in a room is not uniformly distributed as compared the breathing zone with all the area in a room. It means that a study of ventilation efficiency was considered relatively with target zone(a residential or breathing zone) and all the area in a space.

Study on Improvement of Air Quality through Analysis of Ventilation Efficiency in Complex Enclosures of a Ship (선박 복합 밀폐공간 내 환기효율 분석을 통한 공기환경 개선에 관한 연구)

  • Jeong, Jae-Hoon;Song, Doosam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.8
    • /
    • pp.440-447
    • /
    • 2015
  • In the shipbuilding process, the confined work spaces of the ship are formed continuously; the ventilation method can therefore be limited to dilution ventilation due to the complex structure and limited opening of the confined space. Also, it is difficult to evaluate air-quality using measurement and an adequate ventilation method. CFD simulation methods are typically used in analyzing ventilation efficiency in these cases. In this study, a method is suggested to analyze the air quality of the complex enclosures in shipbuilding using CFD. Especially, among the conventional indices, the ventilation efficiency scales or indices, the supply air contribution (SVE4), and the age of the air (SVE3) (fit for the confined and complex enclosure) were applied.

An experimental study of smoke extraction efficiency along with ventilation building location in the mad tunnel (도로터널 내 환기소 위치별 방재 효율에 관한 실험적 연구)

  • Rie, Dong-Ho;Kim, Ha-Young;Yoon, Chan-Hoon;Kim, Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.3
    • /
    • pp.215-222
    • /
    • 2010
  • An experimental study was carried out on a reduced scale model tunnel to investigate the efficiency of disaster prevention at underground and ground ventilation equipments for the fire in road tunnels. Based on Froude modeling, the 1/50 scaled model tunnel (20 m long) was manufactured. The vertical shafts that are used in the analysis of efficiency of disaster prevention are the two models that had considered when the real tunnels are designed and the amounts of smoke exhaust are applied the miniature of the real tunnels' smoke exhaust, 560 and $280\;m^3/s$. As the result of analysis, it is the possible the emissions of the entire quantity of CO gas through the vertical shafts. In the ground ventilation equipments, the concentration of CO is discharged 2.23~2,73 ppm smaller than the underground ventilation equipments. And the temperature rise in the ground ventilation equipments is $0.53{\sim}0.94^{\circ}C$ lower than in the underground ventilation equipments because of a cooling effect of the surface of the tunnel wall. As a result of analysis of CO concentration and the temperature rise in the modeling ventilation equipment, the position of ground ventilation equipment is more effective than the underground ventilation equipment in disaster prevention measures.

A Farm Scale Study on the Modified Ventilation System for Improving Environmental Factors in a Confined Nursery Pig Building (무창자돈사의 환경요인 개선을 위한 변형환기시스템의 현장 평가 연구)

  • Kim, H.T.;Ko, H.J.;Kim, K.Y.;Nishizu, T.;Choi, H.L.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.3 s.116
    • /
    • pp.175-181
    • /
    • 2006
  • Nursery pig building is imperative to provide environmental conditions favorable to maintenance of piglet health and the efficiency of growth rate. To meet the ultimate goal, it is necessary to apply proper ventilation design and construction to a confinement livestock building. This study was conducted to investigate the performance of a modified ventilation system in terms of devised slot-inlet (modification I) and exhaust fan (modification II) to improve air change rate in a confined nursery pig building, with dimension of 5.9 m(W) ${\times}$ 12.6 m(L) ${\times}$ 2.2 m(H) in an Darby Genetic Station. The experiment was carried out in August, especially when the outdoor peak temperature were above $30^{\circ}C$ and the measured indoor environmental factors were temperature, air velocity, humidity and ammonia concentration which have been known to affect the piglet health and growth. There was no difference in indoor temperature between the original and modified ventilation systems, however the air velocity and ammonia concentration in confined nursery pig building with modified ventilation system were, in most cases, better performance than original ventilation system. Therefore, it was concluded that the slot-inlet system that kept indoor environmental factors pertinent and had an economic advantage, should be considered as a ventilation system for decreasing sensible heat from piglet in confined nursery pig building during extreme summer season.

Optimization of the Unducted Auxiliary Ventilation for Large-Opening Underground Limestone Mines (대단면 지하 석회석 광산내 무풍관 국부통기 최적화 연구)

  • Nguyen, Van Duc;Lee, Chang Woo
    • Tunnel and Underground Space
    • /
    • v.29 no.6
    • /
    • pp.480-507
    • /
    • 2019
  • This paper aims at optimizing the auxiliary ventilation system in large-opening limestone mines with unducted fans. An extensive CFD and also site study were carried out for optimization at the blind entries. The fan location, operating mode, and layout are the parameters for optimization. Since the jet stream discharged from the auxiliary fan is flowing faster than 15 m/s in most of the cases, the stream collides with floor, sides or roof and even with the jet stream generated from the other fan placed upstream. Then, it is likely to lose a large portion of its inertial force and then its ventilation efficiency drops considerably. Therefore, the optimal fan installation interval is defined in this study as an interval that maximizes the uninterrupted flowing distance of the jet stream, while the cross-sectional installation location can be optimized to minimize the energy loss due to possible collision with the entry sides. Consequently, the optimization of the fan location will improve ventilation efficiency and subsequently the energy cost. A number of different three-dimensional computational domains representing a full-scale underground space were developed for the CFD study. The velocity profiles and the CO concentrations were studied to design and optimize the auxiliary ventilation system without duct and at the same time mine site experiments were carried out for comparison purposes. The ultimate goal is to optimize the auxiliary ventilation system without tubing to provide a reliable, low-cost and efficient solution to maintain the clean and safe work environment in local large-opening underground limestone mines.

Design and Preparation of High-Performance Bulk Thermoelectric Materials with Defect Structures

  • Lee, Kyu Hyoung;Kim, Sung Wng
    • Journal of the Korean Ceramic Society
    • /
    • v.54 no.2
    • /
    • pp.75-85
    • /
    • 2017
  • Thermoelectric is a key technology for energy harvesting and solid-state cooling by direct thermal-to-electric energy conversion (or vice versa); however, the relatively low efficiency has limited thermoelectric systems to niche applications such as space power generation and small-scale or high-density cooling. To expand into larger scale power generation and cooling applications such as ATEG (automotive thermoelectric generators) and HVAC (heating, ventilation, and air conditioning), high-performance bulk thermoelectric materials and their low-cost processing are essential prerequisites. Recently, the performance of commercial thermoelectric materials including $Bi_2Te_3$-, PbTe-, skutterudite-, and half-Heusler-based compounds has been significantly improved through non-equilibrium processing technologies for defect engineering. This review summarizes material design approaches for the formation of multi-dimensional and multi-scale defect structures that can be used to manipulate both the electronic and thermal transport properties, and our recent progress in the synthesis of conventional thermoelectric materials with defect structures is described.

LARGE EDDY SIMULATION OF ORDINARY & EMERGENCY VENTILATION FLOW IN UNDERGROUND SUBWAY STATION (지하역사 승강장 및 대합실 평상시 비상시 급·배기 환기 Large Eddy Simulation)

  • Jang, Yong-Jun;Ryu, Ji-Min;Park, Duck-Shin
    • Journal of computational fluids engineering
    • /
    • v.18 no.3
    • /
    • pp.72-78
    • /
    • 2013
  • The turbulent flow behavior of air supply and exhaustion in the Shin-gum-ho subway station is analyzed for ordinary and emergency state. The depth of Shin-gum-ho station is 43.6m which consists of the island-type platform(8th floor in underground) and a two-story lobby (first & second floor in underground). An emergency stairway connects between the platform and the lobby. Ventilation operation mode for ordinary state is set up as a combination of air supply and exhaustion in the lobby and platform, while for emergency state it is set up as a full air supply in the lobby and a full exhaustion in the platform. The entire station is covered for simulation. The ventilation diffusers are modeled as 95 square shapes of $0.6m{\times}0.6m$ in the lobby and as 222 square shapes of $0.6m{\times}0.6m$ and 4 rectangular shapes of $1.2m{\times}0.8m$ in the platform. The total of 7.5million grids are generated and whole domain is divided to 22 blocks for MPI efficiency of calculation. Large eddy simulation(LES) is applied to solve the momentum equation and Smagorinsky model($C_s$=0.2) is used as SGS(subgrid scale) model. The time-averaged velocity fields are compared to experimental data and show a good agreement with it.

Characterization of Fine Dust Collection Using a Filter Ventilation (환기장치와 필터를 활용한 미세먼지 제거특성 조사)

  • Jeon, Tae-Yeong;Kim, Jae-Yong
    • Applied Chemistry for Engineering
    • /
    • v.26 no.2
    • /
    • pp.229-233
    • /
    • 2015
  • In this study, we examined the removal characteristics of suspended particulate matters which are one of carcinogens to cause lung cancer. The fine dust capture by a pilot scale filtration system depends on several important variables such as humidity, initial fine dust injection volume, and flow rate. The average concentration of particulate matters in the test chamber decreased, but the ultimate collection efficiency did not change during the filtration under high humidity, compared to those of using ambient conditions The initial injection amount of fine dust did not influence the particle capturing efficiency. When the flow rate reduced from 0.6 m/s to 0.3 m/s, the dust collection time increased approximately 1.4 times. Among all variables tested, the flow rate showed the most significant effect on the removal efficiency of fine particulate matter.

Experimental Studies on PSC Airpit-Slab with Fire Resistance Panel under Static and Dynamic Loads (내화패널이 부착된 프리캐스트 PSC 풍도슬래브의 정적/동적하중에 관한 실험연구)

  • Kim, Tae Kyun;Bae, Jeong;Choi, Heon;Min, In Gi
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.4A
    • /
    • pp.245-253
    • /
    • 2012
  • In the longway tunnel and underground traffic road, the structure of transverse ventilation system is constructed by the airpit slab. In this study, the full scale specimens of the PSC airpit slab that attached fire resistance panel are performed the static and dynamic loading tests for evaluation of bending capacity. The first of all, it confirmed the evaluations about the fundamental efficiency of the fire resistance panel and PSC slab by the 3-point bending test and pull-off test. The tests are performed for evaluation of the bending resistance under ultimate static load and the bonded capacity under dynamic fatigue load. A fatigue test is performed for an investigation of the effect on wind pressure that is developed by transit of traffic. The damage or debonding on surface between fire resistance panel and PSC slab was not developed in dynamic fatigue load test, also the behavior of the specimens is very stable and the debonding of the fire resistance panel attached at the bottom surface of PSC slab was not developed in static load test, too. Therefore, the crack or debonding of the fire resistance panel will be not developed by external loads during the construction or completion of the precast fire resistance system.

A Study on the Design Model of Modular Building System for Disaster Restorations in Fishing and Agrarian Villages (농어촌 재해복구용 모듈러 건축물의 설계안 연구)

  • Lim, Jae-Han
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.9 no.3
    • /
    • pp.33-45
    • /
    • 2007
  • Recently, large scale disasters have been occurred in rural areas. Most people suffering from the disaster live in the temporary containers. These could not provide the fundamental occupancy performances such as thermal insulation, ventilation and heating system. It is very important to rebuild the residence for sufferers quickly and safely. Because modular building system has some advantages such as short construction time, mobility, light-weight structure, modularity, flexibility and economical efficiency, it is expected that it could be easily applied to the disaster restoration. So, this research aims at developing the design model of modular building system for disaster restorations in fishing and agrarian villages. For this purpose, current counterplan for restoration was firstly investigated. Also the basic guideline was established through the investigation of current status of residence in fishing and agrarian villages. Finally, 2 types of design model such as single story residence and temporary accommodation facility were proposed. We could see that we could make the flexible building plan when applying the modular building system to the temporary housing for the sufferers.

  • PDF