• Title/Summary/Keyword: Scale efficiency

Search Result 3,078, Processing Time 0.031 seconds

The Effect of Dead Zone on Hydraulic Efficiency in Clearwell (정수지내 사류지역이 수리학적 효율에 미치는 영향 연구)

  • Lee, Seungjae;Shin, Eunher;Kim, Sunghoon;Park, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.2
    • /
    • pp.177-185
    • /
    • 2007
  • Hydraulic efficiency($T_{10}/T$) in clearwell is often estimated by L/W ratio. However, this estimation is not accurate because other factors which give an effect on hydraulic efficiency such as shape of basin, diffuser wall and intra-basin is ignored. Therefore, in this research, hydraulic efficiency is predicted by the quantitative analysis of dead zone using CFD simulation in a pilot scale clearwell. The results show that the reason why higher L/W ratio increase the hydraulic efficiency is to decrease the dead zone of linear region which is located between baffles. Diffuser wall or intra-basin also affects on hydraulic efficiency with this process. Also, we conclude that hydraulic efficiency can not be reached to 0.8 or higher.

Improve the Quality of Public Medical Centers for the Static, Dynamic Efficiency Analysis (공공의료기관의 품질향상을 위한 정태적.동태적 분석)

  • Moon, Jae-Young;Kim, Yong-Tea
    • Journal of Korean Society for Quality Management
    • /
    • v.38 no.3
    • /
    • pp.393-407
    • /
    • 2010
  • The purpose of this study is to analysis relative efficiency and efficiency in process of time. Thus we use panel data of 34 local public medical centers between 2003 and 2005 to use DEA and Malmquist analysis. The result of our this study is as flow; first, The results of static efficiency of 34 local public medical centers show 10 CCR model and 23 BCC model which is difference of efficiency by economic of scale. Second, a cause of increased efficiency is not only change of technology but also change of efficiency to management system index show between 2003 and 2005 by Malmquist analysis and contracting-out is higher than direct management between 2004 and 2005. That means efficiency of local public medical centers is their own effort and innovation not government subsidies.

An Analysis on the Factors Affecting Rice Production Efficiency in Myanmar

  • Tun, YuYu;Kang, Hye-Jung
    • East Asian Economic Review
    • /
    • v.19 no.2
    • /
    • pp.167-188
    • /
    • 2015
  • The objective of this study is to obtain a better understanding of the current rice production condition in Myanmar through efficiency analysis, especially, to examine the impact of farm mechanization on Myanmar rice production efficiency. For representation of efficiency and the determinants, this paper uses both the data envelopment analysis (DEA) and the stochastic frontier approach (SFA) with variable returns to scale on Myanmar rice production. The efficiency of the rice production was estimated and subsequently the determinants factors were investigated based on the estimated efficiency level of these sample farmers. The empirical evidence finds that farm mechanical tools significantly improve the Myanmar rice production efficiency.

Variability of Hydrologic Partitioning revisiting Horton Index (Horton 지수의 재논의를 통한 수문분할의 변동성)

  • Choi, Dae-Gyu;Choi, Min-Ha;Ahn, Jae-Hyeon;Park, Moo-Jong;Kim, Sang-Dan
    • Journal of Wetlands Research
    • /
    • v.13 no.1
    • /
    • pp.35-44
    • /
    • 2011
  • In order to explore vegetation adaptation to climate variability and the impacts on water balance dynamics, the inter-regional and the inter-annual variability of both water availability and vegetation productivity are investigated. The Horton index, which is the ratio between actual evapotranspiration and catchment wetting as a measure of vegetation water use at catchment-scale, is revisited to quantify the effects of growing-season water availability on hydrologic partitioning at catchment scale. It is shown that the estimated Horton index is relatively constant irrespective of inter-annual climate variability. In addition, the Horton index is compared with catchment-scale vegetation rain use efficiency. The results show that there is an interesting pattern in the response of vegetation water use to water availability. When water becomes the limiting factor for vegetation productivity, the catchment-scale vegetation rain use efficiency converges to a common maximum value in agreement with earlier findings at the ecosystem level.

Analysis of Heat Release Rate with Various Diameter of Heptane Pool Fire Using Large Scale Cone Calorimeter (헵탄의 화원 직경 변화를 고려한 대형콘칼로리미터의 발열량 측정 결과 분석)

  • You, Woo Jun;Nam, Dong-Gun;Youm, Moon Cheon;Kim, Sung-Chan;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.1-7
    • /
    • 2014
  • The present study has been conducted to analyse the effects of various pool diameters on the measurement of heat release rate (HRR) of heptane fire using large scale cone calorimeter (LSC). The burning rate which is the major parameter for HRR compared with the previous model suggested by A. Hamins. The combustion efficiency for heptane by oxygen consumption method is about 91%, which is almost same with the previous results of 92% suggested by J. Gore. The convective HRR by enthalpy consumption method was 54% lower than HRR by oxygen consumption method. This results are practical use for establishing the reliability of heat release rate for fire experiment.

A hybrid inverse method for small scale parameter estimation of FG nanobeams

  • Darabi, A.;Vosoughi, Ali R.
    • Steel and Composite Structures
    • /
    • v.20 no.5
    • /
    • pp.1119-1131
    • /
    • 2016
  • As a first attempt, an inverse hybrid numerical method for small scale parameter estimation of functionally graded (FG) nanobeams using measured frequencies is presented. The governing equations are obtained with the Eringen's nonlocal elasticity assumptions and the first-order shear deformation theory (FSDT). The equations are discretized by using the differential quadrature method (DQM). The discretized equations are transferred from temporal domain to frequency domain and frequencies of the nanobeam are obtained. By applying random error to these frequencies, measured frequencies are generated. The measured frequencies are considered as input data and inversely, the small scale parameter of the beam is obtained by minimizing a defined functional. The functional is defined as root mean square error between the measured frequencies and calculated frequencies by the DQM. Then, the conjugate gradient (CG) optimization method is employed to minimize the functional and the small scale parameter is obtained. Efficiency, convergence and accuracy of the presented hybrid method for small scale parameter estimation of the beams for different applied random error, boundary conditions, length-to-thickness ratio and volume fraction coefficients are demonstrated.

Real-time Object Recognition with Pose Initialization for Large-scale Standalone Mobile Augmented Reality

  • Lee, Suwon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.10
    • /
    • pp.4098-4116
    • /
    • 2020
  • Mobile devices such as smartphones are very attractive targets for augmented reality (AR) services, but their limited resources make it difficult to increase the number of objects to be recognized. When the recognition process is scaled to a large number of objects, it typically requires significant computation time and memory. Therefore, most large-scale mobile AR systems rely on a server to outsource recognition process to a high-performance PC, but this limits the scenarios available in the AR services. As a part of realizing large-scale standalone mobile AR, this paper presents a solution to the problem of accuracy, memory, and speed for large-scale object recognition. To this end, we design our own basic feature and realize spatial locality, selective feature extraction, rough pose estimation, and selective feature matching. Experiments are performed to verify the appropriateness of the proposed method for realizing large-scale standalone mobile AR in terms of efficiency and accuracy.

Development of a robust bench-scale testing unit for low-pressure membranes used in water treatment

  • Huang, Haiou;Schwab, Kellogg;Jacangelo, Joseph G.
    • Membrane and Water Treatment
    • /
    • v.2 no.2
    • /
    • pp.121-136
    • /
    • 2011
  • A bench-scale test has recently been proposed as a predictive tool to minimize the scope of pilot-scale testing or to optimize the operation of full-scale membrane filtration systems. Consequently, a bench-scale testing unit was developed for this purpose and systematically evaluated in this study. This unit was capable of accommodating commercially available, low pressure, hollow fiber (LPHF) membranes with various configurations for testing under conditions comparable to real-world applications. Reproducibility of this unit in assessing membrane fouling and microbial removal efficiency of LPHF membranes was tested and statistically comparable results were obtained. This unit serves as a useful apparatus for academic researchers and utilities to evaluate the performance of LPHF membranes used for water treatment.

Comparison of Operational Efficiency and Quality Efficiency of Medical Services by Country : Focused on OECD Member Countries (국가별 의료서비스의 운영효율성과 품질효율성 비교: OECD 회원국들을 중심으로)

  • Hyunjung Kim;Jiyoon Son
    • Journal of Service Research and Studies
    • /
    • v.11 no.4
    • /
    • pp.43-55
    • /
    • 2021
  • This study analyzed the efficiency of medical services in OECD member countries by dividing it into operational efficiency and quality efficiency. For this purpose, data from 2017-2019 OECD Health Statistics were used. As the analysis method, super efficiency was measured by applying an output-oriented Variable Returns to Scale (VRS) model. As a result of the analysis, Switzerland, Korea, and Italy were included in the high group of operational efficiency, Canada, Greece, Denmark, etc. in the medium group, and Belgium, Germany, and Spain in the low group. Based on quality efficiency, Norway, Switzerland, and Spain are in the high group, and Greece, Denmark, Mexico, etc. are in the medium group, and the Netherlands, Germany, Belgium, etc. were included in the low group. As a result of comparative analysis of efficiency by OECD member countries as of 2018, it was found that Korea's operational efficiency was the most efficient and quality efficiency was inefficient. Korea (0.998) should improve life expectancy by 0.2 (0.2%) and subjective health perception by 44.2 (138.1%) by benchmarking Greece (0.422), Switzerland (0.207), and Spain (0.371) to improve quality efficiency. Unlike most previous studies that focused on operational efficiency, this study measured quality efficiency together and analyzed the efficiency of the medical service industry in each OECD member country. Through this, this study has implications in that it confirmed the international competitiveness of the domestic medical service industry and suggested ways to improve efficiency.

Improvement of the $SO_{x}$ Removal by Adding Dibasic Acids into the JBR FGD Process

  • Lee, Byeong-Kyu;Jeon, Sang-Ki;Cho, Seong-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E4
    • /
    • pp.157-162
    • /
    • 2001
  • Jet Bubbling Reactors(JBRs) were operated for the removal of SO$_{x}$ in flue gases produced from many electric power plants. However, many JBR flue gas desulfurization (FGD) facility faced a decrease of SO$_{x}$ removal efficiency and an increase of scale problems with continuous operations. We increased alkalinity of the SO$_{2}$ absorbing medium by adding the dibasic acids (DBAs) to solve these problems more effectively. The SO$_{2}$ removal efficiency, the purity of CaCO$_{3}$ and COD of the wastewater was measured to identify the addition effects of DBAs (150, 200, 250, and 400 ppm) for 2hr in a day into the JBR attached to the large-scale power plants (400 MW$\times$3). Addition of the DBAs resulted in the improvement of the SO$_{2}$ removal efficiency from 2 to 5% and the purity of the gypsum from 1 to 2%; these improvement were due to the alkalinity increase of the absorbing medium and the reduction of a proportion of un-reacted CaCO$_{3}$, respectively. Also, the scale problems formed by un-reacted CaCO$_{3}$ inside the reaction zone of the JBR were substantially reduced. Even though the effluent COD of the wastewater slightly increased from 10~15 to 18~36 mg/l and the erosion problems in the injection pump and duct occurred, this method of increasing SO$_{2}$ removal efficiency by adding the DBAs could be considered as a profitable approach.ach.

  • PDF