A study on adaptation measures to climate crisis for water supply system of Jeju Special Self-Governing Province (제주특별자치도 상수도 기후위기 적응대책 연구)

  • Jinkeun Kim
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.6
    • /
    • pp.447-456
    • /
    • 2023
  • Risk assessment on Jeju Special Self-Governing Province(JSSGP)'s water supply facilities and establishment of adaptation measures for climate crisis factors were implemented. JSSGP's vulnerability to the climate crisis was high in the order of drought, heat wave, heavy rain and strong wind. As a drought adaptation measure, policies of water saving and revenue water ratio improvement were considered. As for the heat wave adaptation measure, the introduction of an advanced water treatment process was suggested in response to the increase of algae cell number which resulting in taste and odor problem. As for heavy rain adaptation measures, the installation and operation of automatic coagulant injection devices for water purification plants that take turbid surface water were proposed. As a measure to adapt to strong winds, stabilization of power supply such as installation of dual power line was proposed in preparation for power outages. It is expected that water facilities will be able to supply high-quality tap water to customers even under extreme climate conditions without interruption through risk assessment for climate crisis factors and active implementation of adaptation measures.

Development of ECO Driving Meter System for Diesel Locomotives (디젤기관차 연료사용량 측정장치 개발)

  • Park, Tae-Gi;Lee, Eul-Jae
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2357-2364
    • /
    • 2011
  • Diesel locomotive operates the generator with the power from the diesel engine, and it consists of the typical serial-hybrid system which operates the train wheels by converting its generated electric energy into the torque of DC (or AC) motor. However, the technology of locomotives is only focused on trains' controlling power generation mechanism. Hence, it is a current issue that the efficiency of its engine and its generator is relatively lower than that of auto vehicles'. Particularly, since there are no proper equipment to measure the amount of fuel which is essentially necessary for the efficient use of fuel, it is not easy to confirm the instant amount of fuel use as well as the exact average fuel consumption per an hour. Due to those difficulties, it is urgent to develop the device that measures the fuel consumption. Plus, this use of the developed measuring device allows the various and useful analysis relating to the fuel consumption, and this could lead to establishing the efficient driving pattern regarding to fuel saving. This device consists of two flux (fuel level) measuring censors, MCU for calculating the measured values, the information recorder for saving measured values, and the display device for indicating the fuel amount consumed during driving.

  • PDF

Eco-efficiency Analysis of Urban Agglomeration in the Middle Reaches of the Yangtze River

  • Chen, Minghui;Miao, Jianjun
    • The Journal of Industrial Distribution & Business
    • /
    • v.10 no.1
    • /
    • pp.9-17
    • /
    • 2019
  • Purpose - Urban agglomeration construction is one of national strategic plans to accelerate the development of industrialization and urbanization in China, which has threatened the eco-environmental quality at the same time. This paper selected the urban agglomeration in the middle reaches of the Yangtze River as the research area. Research design, data, and methodology - The the slack-based measurement (SBM) model considering undesirable outputs is applied to measure the eco-efficiency of this urban agglomerations during 2006-2015. Results - The empirical results show that average eco-efficiency of the urban agglomeration in the middle reaches of the Yangtze River is 0.595. Regional ecological development is unbalanced. The highest eco-efficiency is recorded at Wuhan Metropolitan Area, and the lowest one is at the Changsha-Zhuzhou-Xiangtan City Group. Energy consumption and waste dust emissions are the key factors led to ecological inefficiency. Based on this, potentials for energy saving and waste dust reducing are calculated. Conclusions - Finally, this study provides policy implications targeted to promote the coordinating development of economy and eco-environment under the construction of urban agglomeration.

of Renovation for Green Building of Public BuildingA Study on Adequacy (공공 건축물의 그린빌딩화를 위한 리노베이션수법의 타당성 연구)

  • Hyun, Gun-Chul;Kim, Tae-Il;Yang, Gun
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.1-10
    • /
    • 2010
  • The aims of this study is to analyze that the double-skinned outer surface of building will be the effective measure to improve the use of space and save energy through the evaluation of the buildings renovation. In other words, it is significantly effective to increase the insulation of the outer surface where the most heat loss occurs; it is also energy-saving to convert the space created by pilotis in the southern and northern parts of the buildings into an double-skinned atrium. Research methods of this study are consisted with two steps, situation analysis and simulation analysis. IRISYS 1000 Series Imager was used for research of situation analysis and Visual DOE 4.0 was used for simulation analysis with the 1st Buildings of Jeju Special self-Governing Province. As results of simulation, it was proved that Double skin Method is more effective for green building than basic model. it was predicted to save 8.6% of energy by Double skin Method. Especially, in case of using of ventilation within double-skinned atrium, it was predicted that saving of energy was most effective than other method.

Analysis of the Building Energy Efficiency Rating Certified for Public Office Buildings (공공기관 업무용 건물의 건축물에너지효율등급 인증 현황 분석)

  • Lee, Han-Sol;Kim, Seo-Hun;Kim, Jonghun;Kim, Jun-Tae;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.75-82
    • /
    • 2015
  • Purpose: The first grade of Korea's Building Energy Efficiency Rating System(BEERS) is required for new government office buildings as a mandatory measure to reduce greenhouse gas emission. However, there is no specific criteria about performance that which level should apply to energy-saving design element for obtaining Building Energy Efficiency Rating 1st grade. Therefore, Certification status should be analyzed firstly, about the office building which is certificated. Certification analysis for office buildings acquired certification therefore should be done first. Method: In this study, Certification status(Office buildings acquired Building Energy Efficiency Rating Certification)was analyzed by classified year, region, specific scale etc. And we analyzed statistically by eliciting an average value of each element influencing to the amount of energy. Result: Energy demands were gradually decreased due to revision of thermal insulation standards for enhanced u-value. Energy consumptions were different from the kind of equipment and yearly trends applied depending on the size of the building. Total primary energy consumptions were influenced by heat source types and the primary energy scale factors.

Estimating Potential Energy Consumption and Carbon Emission Reduction in South Korea Using Non-radial Data Envelopment Analysis Approach (Non-radial Data Envelopment Analysis를 적용한 지역별 에너지 및 이산화탄소 저감가능성 추정)

  • Kim, Kwang-Uk;Kang, Sang-Mok
    • Environmental and Resource Economics Review
    • /
    • v.25 no.2
    • /
    • pp.299-320
    • /
    • 2016
  • This study estimates an energy efficiency of 16 metropolitans and provinces in Korea, and measures potential energy-saving and carbon emission reduction using a non-radial data envelopment analysis method. Based on energy mix scenarios, this study also evaluates the impact of changes in energy structural adjustment on a regional environmental performance. The empirical results show that, on average, 12.70% of energy consumption and 13.73% of carbon emission can be reduced by improvement in energy efficiency, and low efficiency of oil usage in metropolitan cities is a major source of the inefficiency. Furthermore, it is found that energy mix policy should be considered to achieve an extra energy-saving and carbon reduction.

The Recommendation on Power Saving through the Measuring of the Standby Power of OA Equipments (OA기기의 대기전력 측정을 통한 절전 평가 제안)

  • Kim, Man-Geon;Choi, Don-Mook
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.161-167
    • /
    • 2013
  • The purpose of this study was to assess power loss in the computer and office automation equipment and identified a way to save power consumptions through field measurement. In this study, the meaning of standby power was to consume power while waiting for the use of any electronic equipment. This standby consumption was about 11% of total power consumption even though we did not seriously realize it. Therefore, it was very important to measure accurate power consumption at the standby status of electronic equipment. In addition, it also helped to reduce potential risks of electricity associated disasters. This study proposed the way to reduce power losses through automatic turn off switches for power outlets and switches. Finally, this study can evaluate power consumption patterns that can reduce power consumptions and potential risks of power related disasters. This also can achieve the goals of sustainability that can reduce environmental impacts by lowering energy consumptions and greenhouse gas emissions.

A Study on the Generation of Datasets for Applied AI to OLED Life Prediction

  • CHUNG, Myung-Ae;HAN, Dong Hun;AHN, Seongdeok;KANG, Min Soo
    • Korean Journal of Artificial Intelligence
    • /
    • v.10 no.2
    • /
    • pp.7-11
    • /
    • 2022
  • OLED displays cannot be used permanently due to burn-in or generation of dark spots due to degradation. Therefore, the time when the display can operate normally is very important. It is close to impossible to physically measure the time when the display operates normally. Therefore, the time that works normally should be predicted in a way other than a physical way. Therefore, if you do computer simulations based on artificial intelligence, you can increase the accuracy of prediction by saving time and continuous learning. Therefore, if we do computer simulations based on artificial intelligence, we can increase the accuracy of prediction by saving time and continuous learning. In this paper, a dataset in the form of development from generation to diffusion of dark spots, which is one of the causes related to the life of OLED, was generated by applying the finite element method. The dark spots were generated in nine conditions, such as 0.1 to 2.0 ㎛ with the size of pinholes, the number was 10 to 100, and 50% with water content. The learning data created in this way may be a criterion for generating an artificial intelligence-based dataset.

A Study on Methodology for Verifying Energy Saving and Activity in School (학교 건물에서의 에너지절감 성과 활동 검증을 위한 방법론 연구)

  • Lee, Hangju;Kim, Insoo
    • Journal of Energy Engineering
    • /
    • v.29 no.1
    • /
    • pp.25-33
    • /
    • 2020
  • Recently, as the mandatory policy of zero energy building is promoted, policies / systems for transition to Zero Energy School are being promoted, but there is no method to systematically analyze and verify the results of energy saving activities for school buildings. For the study of energy performance verification methodology, the current status of related standards was referred to, and the case study of other methodologies was conducted to examine the tools that can analyze the performance in the field. In addition, this study analyzed the current status and characteristics of energy management through domestic school visits. In this paper, we presented various energy saving projects such as air conditioning and heating facilities, lighting, insulation, change operation behavior, and improve operation methods in new and existing school buildings, and M & V methods for verifying energy savings before and after implementation of energy conservation projects.

The study of in-situ measurement method for wall thermal performance diagnosis of existing apartment (기존 공동 주택의 벽체 열성능 현장 측정법에 관한 연구)

  • Kim, Seohoon;Kim, Jonghun;Yoo, Seunghwan;Jeong, Hakgeun;Song, Kyoodong
    • KIEAE Journal
    • /
    • v.16 no.4
    • /
    • pp.71-77
    • /
    • 2016
  • Purpose : The energy saving in a residential building (apartment) sector is known as one of the effective solution of energy reduction. In South Korea, the government has recently reinforced regulations associated with the energy performance of buildings. However, there is a lack of research on the methods for the energy performance diagnosis that is used to analyze the wall thermal performance of the existing apartments. Because a reliable diagnosis is necessary to save the building energy, this study analyzed wall thermal performance of an existing apartment in Seoul. Method : This paper applied two methods for analysis of the thermal insulation performance; HFM(Heat Flow Meter) method and ASTR(Air-Surface Temperature Ratio) method. The HFM method is suggested by ISO9869-1 code to measure the thermal performance. The ASTR method is proposed by this study for the simplified In-situ measurement and it uses three temperature data (interior wall surface, interior and exterior air) and the overall heat transfer coefficient. This study conducted the experiment of an existing apartment in Seoul using these methods and analyzed the results. Furthermore, the energy simulation tool of the building was used to suggest retrofit of the building based on the results of measurements. Result : The error rate of HFM method and ASTR method was analyzed in about 17 to 20%. As the results of comparison between the initial design values of the wall and the measured values, the 26% degradation of insulation thermal performance was measured. Lastly, the energy simulation tool of the building shows 10.8% energy savings in accordance with the construction of suggested retrofit.