• Title/Summary/Keyword: Saving energy rate

Search Result 328, Processing Time 0.034 seconds

Comparison of detergency effectiveness by the type of household washer, detergent and soil - Focused on detergency, rinsing, fabric damage and tanglement - (가정용 세탁기, 세제 및 오염의 종류별 세탁 성능 비교 - 세탁성, 헹굼성, 섬유손상도, 엉킴도를 중심으로 -)

  • Piao, Shujing;Park, Myung-Ja
    • The Research Journal of the Costume Culture
    • /
    • v.21 no.6
    • /
    • pp.950-960
    • /
    • 2013
  • The purpose of this research is to provide accurate information of household washers and detergents for consumers, so that help the producers who make washing machine and detergent to get basic material and also help consumers to choose washing machine. Experiment was proceed with two type of washers to compare energy consumption, washing performance, rinsing effectiveness further, damage caused by entanglement of laundry and fabric was assessed. Detergent P and T were used to compare the performance related to differences of ingredients of detergent. Soiled fabrics of EMPA 108 set were used to evaluate performance of washing by different types of contamination. A summary of experimental results are : First, for the consumption of water, drum-type washer consumed 53% less than pulsator-type washer. On the other hand, the washing time was almost similar for both these machines, but pulsator-type washer showed shorter progress, implying that power saving was more efficient in this case. Second, the drum-type washer showed better performance for contamination with all types of detergent, but the pulsator-type washer showed better rinsing performance. Third, the drum-type washer performed less data of tangle level and fabric damage. Fourth, detergent "P" exhibited better washing performance than did detergent "T", regardless of the type of soil. And with no limit of detergent variety, water-soluble protein soil showed high removal rate, liposoluble soil especially pigment was hardly removed.

Mechanism Improvement of the Heat Exchanger for the Thermal Efficiency Increase of Hot Air Heater (온풍난방기의 열효율 증대를 위한 열교환기 구조개선)

  • Kang, Geum-Choon;Kang, Yoen-Ku;Ryou, Young-Sun;Kim, Young-Joong;Lee, Si-Young;Paek, Yee
    • Journal of Biosystems Engineering
    • /
    • v.34 no.5
    • /
    • pp.363-370
    • /
    • 2009
  • Hot air heater with light oil combustion is used as the most common heater for greenhouse heating in the winter season. Hot air heaters of 256,246 units have been supplied as main greenhouse heating equipment until 2008 and greenhouse heating cost has reached to 620 billions won in Korea. In order to improve the thermal efficiency of the hot air heater and to reduce the expenses for greenhouse heating, prototype hot air heater was manufactured and tested in this experiment. The heat exchanger of tested prototype hot air heater was circular and hexagonal pipe type and inline and stagger arrangement type. Capacity of the heating was 43,062 kJ/h and total heat transfer area of the heat exchanger was $10.728\;m^2$. According to the performance test, it could supply heat of 38,240 to 35,100 kJ/h depending on the fan motor speed of 1,740~1,220 rpm, respectively. Thermal efficiency of hot air heater was 87.0% to 80.8% in the same conditions. As a result, thermal efficiency of hot air heater with hexagonal pipe-stagger arrangement heat exchanger developed in this study was higher 10.2% than that of conventional hot air heater and heating energy saving rate of 14.3% increased.

Fatigue Strength Evaluation of Carbody and Bogie Frame for the Light Rail Transit System (경량전철에 대한 차체 및 대차틀의 피로강도평가)

  • Lee, Eun-Chul;Lee, Joon-Seong;Choi, Yoon-Jong;Lee, Jung-Hwan;Suh, Myung-Won;Lee, Ho-Yong;Lee, Yang-Chang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.10
    • /
    • pp.77-83
    • /
    • 2008
  • In terms of saving costs, energy and materials, the weight of cars has been gradually reduced by optimizing design of structure, which also gives us good performance. In compliance with this, it should satisfy the lifetime of cars for 25 years under the operation. The purpose of this study is to evaluate the strength of fatigue using date from strain gauges attached carbody and bogie frame. This dynamic stress can be evaluated using S-N curve based on stress amplitude. Modified S-N curve by CORTON-DOLAN is used for more conservative and substantial evaluation. In addition, !he loadings itself of carbody and bogie frame are considered by calculating the rate of the differences which are occurred between empty car and fuiiy occupied car with passengers. Rainflow cycle counting method is applied to arrange the stress data for the modified S-N curve to predict lifetime of the materials. Conclusively the cumulative damages are not only calculated by Miner's Rule, but the safety factors are also determined by Goodman diagram.

Pre-processing of load data of agricultural tractors during major field operations

  • Ryu, Myong-Jin;Kabir, Md. Shaha Nur;Choo, Youn-Kug;Chung, Sun-Ok;Kim, Yong-Joo;Ha, Jong-Kyou;Lee, Kyeong-Hwan
    • Korean Journal of Agricultural Science
    • /
    • v.42 no.1
    • /
    • pp.53-61
    • /
    • 2015
  • Development of highly efficient and energy-saving tractors has been one of the issues in agricultural machinery. For design of such tractors, measurement and analysis of load on major power transmission parts of the tractors are the most important pre-requisite tasks. Objective of this study was to perform pre-processing procedures before effective analysis of load data of agricultural tractors (30, 75, and 82 kW) during major field operations such as plow tillage, rotary tillage, baling, bale wrapping, and to select the suitable pre-processing method for the analysis. A load measurement systems, equipped in the tractors, were consisted of strain-gauge, encoder, hydraulic pressure, and radar speed sensors to measure torque and rotational speed levels of transmission input shaft, PTO shaft, and driving axle shafts, pressure of the hydraulic inlet line, and travel speed, respectively. The entire sensor data were collected at a 200-Hz rate. Plow tillage, rotary tillage, baling, wrapping, and loader operations were selected as major field operations of agricultural tractors. Same or different farm works and driving levels were set differently for each of the load measuring experiment. Before load data analysis, pre-processing procedures such as outlier removal, low-pass filtering, and data division were performed. Data beyond the scope of the measuring range of the sensors and the operating range of the power transmission parts were removed. Considering engine and PTO rotational speeds, frequency components greater than 90, 60, and 60 Hz cut off frequencies were low-pass filtered for plow tillage, rotary tillage, and baler operations, respectively. Measured load data were divided into five parts: driving, working, implement up, implement down, and turning. Results of the study would provide useful information for load characteristics of tractors on major field operations.

Development of Concrete Method for Roof Planting (건물옥상 식재용 콘크리트공법의 개발)

  • 이상태;김진선;황정하;한천구
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.28 no.5
    • /
    • pp.48-57
    • /
    • 2000
  • This paper is dealing with the fundamental properties of planting concrete, replacing the existing cover concrete on the roof of a building. This study is to find out the physical characteristics of the planting concrete and rearing characteristics of the grass throughout the modeling experimental materials. As the results of the experiment, the physical properties of planting concrete show the following results; when the paste to aggregate ratio is 0.2~ 0.4, voids volume : 30~17%, unit weight: 1,710~2,010kg/m3, compressive strength : 45~145kgf/$\textrm{cm}^2$, its pH is more than 11, but is reduced to the proper degree for planting after being neutralized. Kentucky bluegrass covered with planting concrete is grown well. The planting concrete used with blast furnace slag cement shows a better properties at the height, the width and the covering rate by 1.1cm, 0.5mm and 7%, respectively, than those used with ordinary portland cement. Also, the less the paste to aggregate ratio is, the better the plant grows. The orders of the effects of temperature control are as follows; the system of planting concrete with grass>the system of planting concrete without grass>the system of mixed soil>the existed roof system. In case, the planting concrete is placed to the roofs of buildings instead of normal concrete slab, and a number of favorable effect can be expected such as the improvement os environmental factors, the reduction of construction cost, the saving of energy and the reduction of environment load. The future research on the change of a variety of the aggregate conditions and the application of the practical structures should be made, and also the research of the endurance also be performed.

  • PDF

A Study on the Diffuser Inlet Shape of Thermocompressor for MED Desalination Plant (다중효용 담수설비용 열압축기의 디퓨져 입구부 형상에 관한 연구)

  • Jin, Chang-Fu;Song, Young-Ho;Kim, Kyung-Keun;Park, Gi-Tae;Chung, Han-Shik;Choi, Du-Youl
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.869-876
    • /
    • 2008
  • A thermocompressor is the equipment which compresses a vapor to a desired discharge pressure. Since it was first used as the evacuation pump for a surface condenser, it has been widely adopted for energy saving systems due to its high working confidence. In the present study, the geometrical analysis of the shape between the jet nozzle and the diffuser inlet, the drag force was calculated by means of the integrated equation of motion and the computational fluid dynamic (CFD) package called FLUENT. The computer simulations were performed to investigate the effects by the various suction flow rates, the distance from jet nozzle outlet to the diffuser inlet and the dimensions of the diffuser inlet section through the iterative calculation. In addition, the results from the CFD analysis on the thermocompressor and the experiments were compared for the verification of the CFD results. In the case of a jet nozzle, the results from the CFD analysis showed a good agreement with the experimental results. Furthermore, in this study, a special attention was paid on the performance of the thermocompressor by varying the diffuser convergence angle of $0.0^{\circ}$, $0.5^{\circ}$, $1.0^{\circ}$, $2.0^{\circ}$, $3.5^{\circ}$ and $4.5^{\circ}$. With the increase of the diffuser convergence angle. the suction capacity was improved up to the degree of $1.0^{\circ}$ while it was decreased over the degree of $1.0^{\circ}$.

Acoustic Valve Leak Diagnosis and Monitoring System for Power Plant Valves (발전용 밸브누설 음향 진단 및 감시시스템)

  • Lee, Sang-Guk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.425-430
    • /
    • 2008
  • To verify the system performance of portable AE leak diagnosis system which can measure with moving conditions, AE activities such as RMS voltage level, AE signal trend, leak rate degree according to AE database, FFT spectrum were measured during operation on total 11 valves of the secondary system in nuclear power plant. AE activities were recorded and analyzed from various operating conditions including different temperature, type of valve, pressure difference, valve size and fluid. The results of this field study are utilized to select the type of sensors, the frequency band for filtering and thereby to improve the signal-to-noise ratio for diagnosis for diagnosis or monitoring of valves in operation. As the final result of application study above, portable type leak diagnosis system by AE was developed. The outcome of the study can be definitely applied as a means of the diagnosis or monitoring system for energy saving and prevention of accident for power plant valve. The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18 ". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

A Study on the Foundation of the Standard of Temperature and Humidity for Preventing Condensation in Apartment Housings (공동주택 세대내 결로방지 설계를 위한 실내외 온습도 기준 수립 연구)

  • Hwang, Ha-Jin;Kim, Jong-Yeop;Lee, Jong-Sung
    • Land and Housing Review
    • /
    • v.2 no.3
    • /
    • pp.269-276
    • /
    • 2011
  • Recently, the chance of dew condensation in apartment buildings is increasing because of several reasons. For example, ventilation rate has been decreased because of high-insulations and airtightness for saving energy. Besides, the humidity has been made by drying washes, cooking and bathing inside of apartment buildings. However, there is lack of resonable design criteria for preventing condensation in real life and real surroundings. Therefore, this study is aimed at making a resonable design criteria of preventing condensation by measuring the indoor temperature and humidity in real life. In addition to this, it is aimed at making a resonable outdoor condition and classifying regions by using weather data. The following are the results. The interior criterion for condensation was set up $25^{\circ}C$ and a relative humidity of 55%. The outdoor criterion for condensation was set up $20^{\circ}C$, $-15^{\circ}C$, and $10^{\circ}C$ respectively for the hard frost, middle, and southern areas.

A Study on the Perception of Water Reuse R&D Support and Water Reuse Vitalization Policy (물 재이용 연구개발 지원 및 활성화 정책 인식에 관한 연구)

  • Kim, Yeon-Shik;Lee, Yong-Sun
    • Industry Promotion Research
    • /
    • v.1 no.1
    • /
    • pp.143-149
    • /
    • 2016
  • This study verified the relationship on the perception of water reuse R&D support and water reuse vitalization policy. The study results showed that the perception of water reuse importance and effectiveness positively affected the perception of the necessity of water reuse vitalization policy, necessity of supporting water reuse water-saving product company, necessity of investing water reuse(p<.001). Also, gender, education, occupation, type of residence and monthly water rate significantly affected the between-group differences of the perception of water reuse vitalization policy. This study provided implications for preparing water reuse investment and vitalization policy by the relationship on the perception of water reuse R&D support and water reuse vitalization policy.

Fabrication of the catalyst free GaN nanorods on Si grown by MOCVD

  • Ko, Suk-Min;Cho, Yong-Hoon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.232-232
    • /
    • 2010
  • Recently light emitting diodes (LEDs) have been expected as the new generation light sources because of their advantages such as small size, long lifetime and energy-saving. GaN, as a wide band gap material, is widely used as a material of LEDs and GaN nanorods are the one of the most widely investigated nanostructure which has advantages for the light extraction of LEDs and increasing the active area by making the cylindrical core-shell structure. Lately GaN nanorods are fabricated by various techniques, such as selective area growth, vapor-liquid-solid (VLS) technique. But these techniques have some disadvantages. Selective area growth technique is too complicated and expensive to grow the rods. And in the case of VLS technique, GaN nanorods are not vertically aligned well and the metal catalyst may act as the impurity. So we just tried to grow the GaN nanorods on Si substrate without catalyst to get the vertically well aligned nanorods without impurity. First we deposited the AlN buffer layer on Si substrate which shows more vertical growth mode than sapphire substrate. After the buffer growth, we flew trimethylgallium (TMGa) as the III group source and ammonia as the V group source. And during the GaN growth, we kept the ammonia flow stable and periodically changed the flow rate of TMGa to change the growth mode of the nanorods. Finally, as the optimization, we changed the various growth conditions such as the growth temperature, the working pressure, V/III ratio and the doping level. And we are still in the process to reduce the diameter of the nanorods and to extend the length of the nanorods simultaneously. In this study, we focused on the shape changing of GaN nanorods with different growth conditions. So we confirmed the shape of the nanorods by scanning electron microscope (SEM) and carried out the Photoluminescence (PL) measurement and x-ray diffraction (XRD) to examine the crystal quality difference between samples. Detailed results will be discussed.

  • PDF