• Title/Summary/Keyword: Saturation management

Search Result 192, Processing Time 0.022 seconds

A Study on the Introduction and Application Plan of the Mobile Saturation Diving System for ROK Navy Salvage Operations (한국 해군의 해난구조작전을 위한 이동식 포화잠수체계 도입 및 활용방안에 관한 연구)

  • Yu, Ho-Hwi;Kang, Sin-Young;Lim, An
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.4
    • /
    • pp.389-396
    • /
    • 2015
  • This study examined how to improve the Korean Navy diving system, particularly focused on using the mobile saturation diving system. This study determined the range of navy operations, and suggested requirements of mobile saturation diving system from the analysis of previous study and current Navy Diving system. Also, this study examined the use of military strategy in terms of its technical and applicable possibility for the enhancement of current system. In addition, the study analyzed both advantages/disadvantages of importing mobile saturation diving system products and domestic development. To review measures in installing and operating such system, this study included analysis on the effectiveness of individual platform. As the result, the study suggested requirements of mobile saturation diving system to be able to be operated by more than 6 divers for more than 17 days at more than 200m depth. And the study confirmed that there are beneficial to use mobile saturation diving system and current Navy saturation diving system together. However, it is low economical efficiency to change current Navy gas diving system to Saturation diving system. To review measures in installing and operating such system, this study suggested that second ATS-II should be built to be able to install mobile saturation diving system. Also, this study generated an utilization method of the system to use it for training when peacetime, and than it should be installed on other platform to use as additional salvage strength during wartime.

Performance Evaluation of the HomePNA 3.0 Asynchronous MAC Mode with Collision Management Protocol (HomePNA 3.0 비동기 MAC 모드의 Collision Management Protocol 성능 분석)

  • 김희천;정민영;이태진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.7A
    • /
    • pp.727-734
    • /
    • 2004
  • Collision Management Protocol (CMP) efficiently resolves collisions when data frames are transmitted in networks consisting of HomPNA 3.0 asynchronous MAC mode device with random access. Unlike Distributed Fair Priority Queueing (DFPQ) algorithm in HomePNA 2.0 or Binary Exponential Backoff (BEB) algorithm in IEEE 802.11, order of retransmission is decided according to Collision Signaling Sequence (CSS) values allocated to each device. Thus, CMP can minimize the number of mean collisions because order of retransmission is decided in a deterministic way. In this paper. we evaluate the saturation performance of CMP in HomePNA 3.0 using an analytic method.

Effect of Tillage on Nonpoint Source Pollution of Surface and Ground Water System (I); Effect of Tillage Practices on Density and Saturation of Soil

  • ;shirmohammadi,Adel
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.34 no.E
    • /
    • pp.1-11
    • /
    • 1992
  • Increasing national concern on nonpoint source pollution of surface and ground water Systems has led researchers and policy makers to develop certain agricultural Best Management Practices. As an initial step of broad study program above mentioned, this study reflected the effects of different tillage practice on bulk density and degree of saturation on two regional soils, namely Tama silt loam and Catlin silt loam. Results may help to clarify some of the conflicting findings on the impact of tillage systems on these parameters and it may also explain some of the reasons for specific role that different tillage systems play regarding nonpoint source pollution from agricultural fields.

  • PDF

Differences of Blood Oxygen Saturation between Male and Female due to Change of Supply Rate of Highly Concentrated Oxygen (고농도 산소 공급량 변화에 따른 남/녀 혈중 산소 포화도의 차이)

  • Yi, Jeong-Han;Choi, Mi-Hyun;Kim, Ji-Hye;Lee, Su-Jeong;Yang, Jae-Woong;Chung, Soon-Cheol;Lim, Dae-Woon;Lee, Dong-Hyung;Min, Byung-Chan
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.32 no.4
    • /
    • pp.203-207
    • /
    • 2009
  • The purpose of this study was to examine differences between male and female in blood oxygen saturation due to 93% oxygen administration of the three levels (1L/min, 3L/min, 5L/min). Ten healthy male ($25.0{\pm}1.8$ years) and ten female ($23.7{\pm}1.9$ years) college students were selected as the subjects for this study. The experiment consisted of three runs, i.e., the three levels of 93% oxygen administration, respectively. The each run consisted of three phases, i.e., Rest 1 (5 min), Hyperoxia (10 min), and Rest 2 (5 min). Blood oxygen saturation were measured throughout the three phases. By increasing the supply rate of highly concentrated oxygen, rising rate of blood oxygen saturation was increased. Blood oxygen saturation of female was higher than male regardless of supply rate of highly concentrated oxygen and phases.

Ammonia half-saturation constants of sludge with different community compositions of ammonia-oxidizing bacteria

  • Kayee, Pantip;Rongsayamanont, Chaiwat;Kunapongkiti, Pattaraporn;Limpiyakorn, Tawan
    • Environmental Engineering Research
    • /
    • v.21 no.2
    • /
    • pp.140-144
    • /
    • 2016
  • Owing to the kinetic differences in ammonia oxidation among ammonia-oxidizing microorganisms (AOM), there is no standard set of kinetic values that can be used as a representative set for nitrifying wastewater treatment plant (WWTP) design. As a result, this study clarified a link between the half-saturation constants for ammonia oxidation (Ks) and the dominant ammonia-oxidizing bacterial (AOB) groups in sludge from full-scale WWTPs and laboratory-scale nitrifying reactors. Quantitative polymerase chain reaction analyses revealed that AOB affiliated with the Nitrosomonas oligotropha cluster were the dominant AOM groups in the sludge taken from the low-ammonia-level WWTPs, while AOB associate with the Nitrosomonas europaea cluster comprised the majority of AOM groups in the sludge taken from the high-ammonia-level WWTPs and nitrifying reactors. A respirometric assay demonstrated that the ammonia Ks values for the high-ammonia-level WWTPs and nitrifying reactors were higher than those of the low-ammonia-level plants. Using the Ks values of available AOM cultures as a reference, the Ks values of the analyzed sludge were mainly influenced by the dominant AOB species. These findings implied that.different sets of kinetic values may be required for WWTPs with different dominant AOM species for more accurate WWTP design and operations.

ANALYSIS OF AN SEIQRVS EPIDEMIC DYNAMICS FOR INFECTIOUS VIRAL DISEASE: QUARANTINE AS A CONTROL STRATEGY

  • RAKESH SINGH TOMAR;JOYDIP DHAR;AJAY KUMAR
    • Journal of applied mathematics & informatics
    • /
    • v.41 no.1
    • /
    • pp.107-121
    • /
    • 2023
  • An epidemic infectious disease model consists of six compartments viz. Susceptible, Exposed, Infected, Quarantine, Recovered, and Virus with nonlinear saturation incidence rate is proposed to know the viral disease dynamics. There exist two biological equilibrium points for the model system. The system's local and global stability is done through Lyapunov's direct method about equilibrium points. The sensitivity analysis has been performed for the basic reproduction number and equilibrium points through the normalized forward sensitivity index. Sensitivity analysis shows that virus growth and quarantine rates are more sensitive parameters. In support of mathematical conclusions, numerical experimentation has been shown.

The Comparison of Electrical Conductivity for Soil Solutions Extracted in Field Capacity and Saturation-Paste (포장용수량과 포화 반죽 토양용액의 전기전도도 비교)

  • Lee, Ye-Jin;Lee, Jong-Sik;Yang, Jae-E.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.6
    • /
    • pp.776-781
    • /
    • 2010
  • Estimating the electrical conductivity of the saturation-paste (SP) is a common method to assess soil salinity. To assess soil salinity realistically, it is important to extract soil solution under field capacity. However, few studies on salinity assessment have been conducted for soil solution extracted under field capacity (-33 kPa; FC) moisture condition due to difficulty in soil solution extraction. This study was conducted to evaluate whether saturation-paste can represent field condition. Soil solutions were extracted from 22 soils in the plastic film house (PFH) and 18 soils in the reclaimed land (RL) at saturation and field capacity moisture conditions. Those were analyzed for pH, EC, cations ($K^+$, $Ca^{2+}$, $Mg^{2+}$, $Na^+$) and anions ($Cl^-$, ${NO_3}^-$, ${PO_4}^{3-}$, ${SO_4}^{2-}$). Both cations and anions of soil solution extracted from FC showed high correlations with ions extracted from SP in the PFH and the RL, except for ${NO_3}^-$, ${PO_4}^{3-}$ in the RL. Results of the t-test, the ECe and $EC_{FC}$ were not significant at significance level 0.05. The slopes of the equations between $EC_{FC}$ and ECe at more than sand 50% soils were higher than less than sand 50% soils, and differences of saturation percentage between SP and FC showed larger as increasing sand percentage. EC was related to soil water retention by soil texture. To determine the EC, soil texture and other soil properties which effect the soil moisture should be considered.

Wearable oxygen saturation measurement platform for worker safety management (작업자의 안전관리를 위한 웨어러블 산소포화도 측정 플랫폼)

  • Lee, Yun Ju;Song, Chai Jong;Yoo, Sun Kook
    • Smart Media Journal
    • /
    • v.11 no.9
    • /
    • pp.30-38
    • /
    • 2022
  • It is important to grasp biometric data in real time for prompt action in the event of a safety accident at a work site where the risk of safety accidents exists. Among them, blood oxygen saturation is the most important factor in maintaining human life, so real-time oxygen saturation measurement and monitoring is necessary according to the situation as a preemptive response for worker safety management. By receiving real-time bio-signals from workers wearing health and life-risk protective clothing, and sharing and analyzing the worker's risk status in an external system, it is possible to diagnose the worker's current condition and efficiently respond to emergencies that may occur to the worker. In this paper, we propose a wearable oxygen saturation measurement platform technology that can monitor the risk of harmful gases and oxygen saturation of the wearer in real time and ensure the wearer's activity and safety in order to cope with emergency situations at the scene of an accident. If we overcome the limitations identified through the results of the proposed system later and apply improved biodata such as motion correction to the platform, we expect that it will be usable not only in hazardous gas environments, but also in hospitals and homes for emergency patients.

Assessment of The Above-Ground Carbon Stock and Soil Physico-Chemical Properties of an Arboretum within The University of Port Harcourt, Nigeria

  • Akhabue, Enimhien Faith;Chima, Uzoma Darlington;Eguakun, Funmilayo Sarah
    • Journal of Forest and Environmental Science
    • /
    • v.37 no.3
    • /
    • pp.193-205
    • /
    • 2021
  • The importance of forests and trees in climate change mitigation and soil nutrient cycling cannot be overemphasized. This study assessed the above-ground carbon stock of two exotic and two indigenous tree species - Gmelina arborea, Tectona grandis, Khaya grandifoliola and Nauclea diderrichii and their litter impact on soil nutrient content of an arboretum within the University of Port Harcourt, Nigeria. Data were collected from equal sample plots from the four species' compartments. Tree growth variables including total height, diameter at breast height, crown height, crown diameter and merchantable height were measured for the estimation of above-ground carbon stock. Soil samples were collected from a depth of 0-30 cm from each compartment and analyzed for particle size distribution, organic carbon, total nitrogen, available phosphorus, exchangeable bases, exchangeable acidity, cation exchange capacity, base saturation, pH, Manganese, Iron, Copper and Zinc. Analysis of Variance (ANOVA) was used to test for significant difference (p<0.05) in the carbon contents of the four species and the soil nutrient contents of the different species' compartments. Pearson correlation was used to assess the relationships between the carbon contents, growth parameters and soil parameters. The highest and lowest carbon stock per hectare was observed for G. arborea (151.52 t.ha-1) and K. grandifoliola (45.45 t.ha-1) respectively. Cation exchange capacity and base saturation were highest and lowest for soil under G. arborea and K. grandifoliola respectively. The pH was highest and lowest for soil under G. arborea and T. grandis respectively. Carbon stock correlated positively with dbh, crown diameter, merchantable height and Zn and negatively with base saturation. The study revealed that G. arborea and N. diderrichii can effectively be used for reforestation and afforestation programmes aimed at climate change mitigation across Nigeria. Therefore, policies to encourage and enhance their planting should be encouraged.