• 제목/요약/키워드: Saturation iron core

검색결과 48건 처리시간 0.022초

Finite Element Study of Ferroresonance in single-phase Transformers Considering Magnetic Hysteresis

  • Beyranvand, Morteza Mikhak;Rezaeealam, Behrooz
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.196-202
    • /
    • 2017
  • The occurrence of ferroresonance in electrical systems including nonlinear inductors such as transformers will bring a lot of malicious damages. The intense ferromagnetic saturation of the iron core is the most influential factor in ferroresonance that makes nonsinusoidal current and voltage. So the nonlinear behavior modeling of the magnetic core is the most important challenge in the study of ferroresonance. In this paper, the ferroresonance phenomenon is investigated in a single phase transformer using the finite element method and considering the hysteresis loop. Jiles-Atherton (JA) inverse vector model is used for modeling the hysteresis loop, which provides the accurate nonlinear model of the transformer core. The steady-state analysis of ferroresonance is done while considering different capacitors in series with the no-load transformer. The accurate results from copper losses and iron losses are extracted as the most important specifications of transformers. The validity of the simulation results is confirmed by the corresponding experimental measurements.

히스테리시스 특성을 고려한 자속구속형 고온초전도 사고전류 제한기의 사고전류 제한특성 분석 (Analysis on Fault Current Limiting Characteristics of a Flux-Lock Type HTSC Fault Current Limiter with Hysteresis Characteristic)

  • 임성훈;최명호
    • 조명전기설비학회논문지
    • /
    • 제21권2호
    • /
    • pp.94-98
    • /
    • 2007
  • 자속구속형 초전도 사고전류 제한기는 평상시 자기적인 결합에 의해 철심의 히스테리시스 손실이 발생하지 않는 특징이 있다. 그러나 사고시에는 사고전류증가로 인해 고온초전도 소자의 저항발생과 함께 철심의 포화가 발생할 경우 제한기의 사고전류제한 특성을 저하시키는 현상이 발생하게 된다. 따라서 본 논문에서는 이를 분석하고 억제하기 위한 설계방안을 도출하기 위해 자속구속형 고온초전도 사고전류 제한기의 구성요소인 자속구속 리액터의 히스테리시스 특성을 고려한 사고전류 제한특성을 분석하였다. 이를 위해 제한기의 등가회로와 사고전류 제한실험으로부터 히스테리시스 곡선을 도출하였다. 1, 2차권선의 인덕턴스 비에 따른 히스테리시스 곡선으로부터 인덕턴스비가 증가함에 따라 제한되는 사고전류크기는 증가한 반면 사고시 자속구속형 사고전류제한기의 구성요소인 철심의 포화가 억제됨을 확인할 수 있었다.

고온 초전도 전원장치를 이용한 BSCCO Magnet의 충전 및 영구전류 운전 특성 (Charging and Persistent-Current Mode Operating Characteristics of BSCCO Magnet Using High-Tc Superconducting Power Supply)

  • 조현철;양성은;김영재;황영진;윤용수;정윤도;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권1호
    • /
    • pp.30-34
    • /
    • 2009
  • This paper deals with charging and persistent-current mode operating characteristics of BSCCO magnet load using high-temperature superconducting (HTS) power supply. The HTS power supply consists of two heater-triggered switches, an iron-core transformer with the primary copper winding and the secondary BSCCO solenoid, and a BSCCO magnet load. The magnet load was fabricated by double pancake winding and its inductance is about 21 mH. A hall sensor was installed at the middle of the magnet load to measure the current in the load. In order to investigate the efficient pumping characteristics, operating tests of heater-triggered switch with respect to dc heater current were carried out, and the electromagnet current was determined by considering saturation characteristics of its iron core. The saturation characteristics of charged current in the magnet load were observed with respect to various pumping periods: 12 s, 14 s, 24 s and 32 s. After charging the magnet load, the persistent current was measured. The operating characteristics of the persistent current mode were mainly determined by joint resistance and magnet load.

내삽법 기반의 최소자승법을 이용한 개선된 CT 포화 복원 알고리즘 (An Enhanced Compensation Algorithm for the CT Saturation Using Interpolation-based LSQ(Least Square) Fitting Method)

  • 류기찬;강상희;이봉현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.14-15
    • /
    • 2006
  • A saturation of magnetic flux in the core may occur when a large primary current flows when the iron-cored current transformer is used. This saturation makes the distorted secondary current of the CT. the distorted secondary current may cause the mal-operation or operation time delay of protective relays. CT compensation algorithm using The LSQ(Least Square) fitting method has a problem. It needs to acquire enough data for executing this algorithm without an error. In this paper, an enhanced algorithm using interpolation based LSQ(Least Square) Fitting Method is proposed. The Lagrange Interpolation Method is used for the interpolation and CT is simulated by EMTP. The results show that the proposed algorithm can accurately compensate a distorted secondary current more than existing Algorithm when the saturation severely occurs.

  • PDF

자기부상열차 추진용 리니어모터 효율향상 설계연구 (A Study on Design of Linear Motor for Maglev for High Efficiency)

  • 김윤현;김기찬
    • 전기학회논문지
    • /
    • 제65권4호
    • /
    • pp.561-566
    • /
    • 2016
  • In this paper, effective design method of linear induction motor(LIM) for Maglev is proposed in order to maximize system efficiency of Maglev. For the high system efficiency of Maglev, it is important to minimize weight of traction motor. Light weight design by changing materials of core and winding is conducted without changing volume of LIM. For the silicon steel core of primary part for magnetic flux path, iron-cobalt alloy steel with high magnetic saturation characteristic compared to silicon steel is suggested. Moreover, aluminium winding with light weight instead of copper winding is wounded in the widen slot area due to the high magnetic saturation level. For the verification of performance of proposed model, the characteristics are analyzed by using finite element method(FEM).

철심 변류기 2차 전류 보상 알고리즘 (A Compensating Algorithm for the Secondary Current of Iron-cored Current Transformers)

  • 강용철;박종근;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.628-630
    • /
    • 1995
  • CT saturation may cause protective relays to malfunction. The conventional method to deal with the problem is overdimensioning of the core so that CTs can carry up to 20 times the rated current without exceeding 10 % ratio correction. However, this not only reduces the sensitivity of relays, but also increases the CT core size. This paper presents a technique of estimating the secondary current corresponding to the CT ratio under CT saturation using the magnetization curve. The proposed algorithm can improve the sensitivity of relays to low level faults and minimize the instability of relays for external faults.

  • PDF

자속구속형 고온초전도 사고전류 제한기의 히스테리시스 특성 분석 (Analysis on Hysteresis Characteristics of Flux-Lock Type HTSC Fault Current Limiter)

  • 임성훈;한병성;박형민;조용선;한태희;두호익;최효상
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.493-495
    • /
    • 2006
  • The hysteresis characteristics of flux-lock reactor, which is an essential component of flux-lock type superconducting fault current limiter (SFCL), was investigated. The hysteresis loss of iron core in flux-lock type SFCL does not happen due to its winding's structure especially in the normal state. From the equivalent circuit for the flux-lock type SFCL and the fault current limiting experiments, the hysteresis curves could be drawn. Through the hysteresis curves together with the fault current level due to the inductance ratio for the 1st and 2nd windings, the increase of the number of turns in the 2nd winding of the flux-lock type SFCL had a role to prevent the iron core from saturation.

  • PDF

The Microencapsulated Ascorbic Acid Release in vitro and Its Effect on Iron Bioavailability

  • Lee, Jun-Beum;Ahn, Joung-Jwa;Lee, Jong-Hwi;Kwak, Hae-Soo
    • Archives of Pharmacal Research
    • /
    • 제26권10호
    • /
    • pp.874-879
    • /
    • 2003
  • The present study was carried out to examine the stability of microencapsulated ascorbic acid in simulated-gastric and intestinal situation in vitro and the effect of microencapsulated ascorbic acid on iron bioavailability. Coating materials used were polyglycerol monostearate (PGMS) and medium-chain triacylglycerol (MCT), and core materials were L-ascorbic acid and ferric ammonium sulfate. When ascorbic acid was microencapsulated by MCT, the release of ascorbic acid was 6.3% at pH 5 and 1.32% at pH 2 in simulated-gastric fluids during 60 min. When ascorbic acid was microencapsulated by PGMS, the more ascorbic acid was released in the range of 9.5 to 16.0%. Comparatively, ascorbic acid release increased significantly as 94.7% and 83.8% coated by MCT and PGMS, respectively, for 60 min incubation in simulated-intestinal fluid. In the subsequent study, we tested whether ascorbic acid enhanced the iron bioavailability or not. In results, serum iron content and transferring saturation increased dramatically when subjects consumed milks containing both encapsulated iron and encapsulated ascorbic acid, compared with those when consumed uncapsulated iron or encapsulated iron without ascorbic acid. Therefore, the present data indicated that microencapsulated ascorbic acid with both PGMS and MCT were effective means for fortifying ascorbic acid into milk and for enhancing the iron bioavailability.

과도상태에서 PT 철공진의 해석적 분석 (Analytical Analysis of PT Ferroresonance in the Transient-State)

  • 강용철;이병은;정태영;김연희
    • 전기학회논문지
    • /
    • 제59권5호
    • /
    • pp.860-865
    • /
    • 2010
  • When a circuit breaker is opened, a large capacitance around the buses, the circuit breaker and the potential transformer (PT) might cause PT ferroresonance. During PT ferroresonance, the iron core repeats saturation and unsaturation even though the supplied voltage is a rated voltage. This paper describes an analytical analysis of PT ferroresonance in the transient-state. To analyze ferroresonance analytically, the iron core is modelled by a simplified two-segment core model in this paper. Thus, a nonlinear ordinary differential equation (ODE) for the flux linkage is changed into a linear ODE with constant coefficients, which enables an analytical analysis. In this simplified model, each state, which is either saturated or unsaturated state, corresponds to one of the three modes, i.e. overdamping, critical damping and underdamping. The flux linkage and the voltage in each state are obtained analytically by solving the linear ODE with constant coefficients. The proposed transient analysis is effective in the more understanding of ferroresonance and thus can be used to design a ferroresonance prevention or suppression circuit of a PT.

유한 요소법에 의한 2자유도 스텝모터의 설계 (Design of Prototype Rotary-Lineat Step Motor by the Finite Element Method)

  • 정태경;한송엽;원종수
    • 대한전기학회논문지
    • /
    • 제35권12호
    • /
    • pp.567-572
    • /
    • 1986
  • In this paper, a new type of step motor with two degree of mechanical freedom, which is named rotary-Linear Step Motor(RLSM), is presented. Its rotor axis can perform linear and rotary motions either separately or simultaneously. This paper discribes the design of RLSM using finite element method in which the magnetic saturation effect of the iron core is taken into account. The design parameters such as torques, forces and inductances are obtained from the computed magnetic vector potentials. A new type of Rotary-Linear Step Motor was constructed. The calculated parameters agree well with measurements.

  • PDF