• Title/Summary/Keyword: Saturation field

Search Result 542, Processing Time 0.029 seconds

Estimation of Unprotected Left-Turn Saturation Flows (비보호 좌회전 포화유률 추정)

  • 김경환
    • Proceedings of the KOR-KST Conference
    • /
    • 1998.10a
    • /
    • pp.236-244
    • /
    • 1998
  • When the capacity and traffic operation at signalized intersections are analyzed in Korea, the unprotected left-turn saturation flow rate, which is an important parameter for the analysis, is estimated form the USHCM model. thus, exact analysis of the left-turn is not possible because of the difference of traffic environments between two contries. In order to improve this problem, it is undertaken in this study to develop techniques for the estimation of unprotected left-turn saturation flows based on Korean drivers' data. As study intersections, signalized or unsignalized intersections on the 6, 4 and 2 lane streets are selected. the data for the saturation flow measurement and gap-acceptance behavior analysis are inputed in a notebook computer on the sites. The critical acceptance gaps of the 6, 4, and 2 lane streets are analyzed to be 6.0 secs, 4.6 secs, and 4.3 secs respectively. the average minimum headway of the left-turn vehicle was observed to be 2.6 secs. As the model to estimate unportected left-turn saturation flows, the drew model is recommended for 6 and 4 lane streets, and a graph is suggested for the 2-lane street. As the values of the parameters of the Drew model, the 2.6 secs of this study is recommended for the average minimum headway of the left-turn. But, the critical acceptance gap varies according to the approach speed of opposing traffic and driver population, it requires field survey to measure the gap of an intersection; however, the values of the gaps studied in this study may be used for the general intersections in urban area in Korean.

  • PDF

Near-field optical study of 3rd order Nonlinear properties of amorphous silicon (비정질 실리콘의 3차비선형 효과에 대한 근접장 광학 연구)

  • 최윤진;박준형;김명룡;제원호;이범구
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.160-161
    • /
    • 2000
  • The 3rd order nonlinear properties show Optical bleaching (Saturation) and Reverse saturation in absorption aspect, whereas Self-focusing[3][4] and Self-defocusing in refraction aspect. Optical bleaching and Self-focusing phenomena of those properties in particular can be useful to make the optical beam spot size smaller for application on the higher optical storage density. (omitted)

  • PDF

Effects of NiFeCo of NiFe Insertion Layers on the Giant Magnetoresistance Behavior of Ni/Cu Artificial Superlattice (Ni/Cu 인공초격자에서 NiFeCo 및 NiFe 계면 삽입층이 거대자기저항 거동에 미치는 영향)

  • 송용진;주승기
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.6
    • /
    • pp.963-967
    • /
    • 1995
  • Ultra thin layers of NiFeCo or NiFe were inserted at the interfaces of Ni and Cu to form a multilayer structure. In case of inserting a NiFe layer, the magnetoresistance was about 6%, the saturation magnetic field was 50 Oe and the hysteresis of R-H (resistance-magnetic field) was very small. In case of inserting a NiFeCo layer, the magnetoresistance increased to about 7% but the saturation magnetic field and hysteresis were also increased. The increase of the output under biased magnetic field was much larger in case of inserting a NiFe layer because of relatively smaller hysteresis in R-H behavior.

  • PDF

Effect of Annealing on the Magnetic Anisotropy of Amorphous $Co_{89}Nb{8.5}Zr{2.5}$Thin Films ($Co_{89}Nb{8.5}Zr{2.5}$ 비정질 박막의 이방성에 미치는 열처리 효과)

  • 김현식;민복기;송재성;오영우
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.6
    • /
    • pp.486-492
    • /
    • 1998
  • The amorphous Co-based magnetic films have a large saturation flux density, a low coercive force, and a zero magnetostriction constant. Therefore, they have been studied for application to magnetic recoding heads and micro magnetic devices. However, it was found that the magnetic anisotropy was changed for each film fabrication processes. In this study, we investigated how to control the anisotropy of sputtered amorphous $Co_{89}Nb{8.5}Zr{2.5}$ films. After deposition, the rotational field annealing ant the uniaxial field annealing were performed under the magnetic field of 1.5 kOe. the annealing was done at the temperature range from 400 to $600^{\circ}C$ for one hour. As-deposited amorphous $Co_{89}Nb{8.5}Zr{2.5}$ thin film had saturation magnetization ($4\piM_5$) of 0.8 T, coercive force($_IH_C$) of 1.5 Oe, and anisotropy field($H_k$) of 11 Oe. The amorphous $Co_{89}Nb{8.5}Zr{2.5}$ thin films annealed by rotational field annealing at $500^{\circ}C$ for one hour was found to be isotropy, and $4\piM_5$ of 0.9 T was obtained from these films, Also, the magnetic anisotropy of as-deposited films could be controlled by uniaxial field annealing at $400^{\circ}C$ for one hour. Anisotropy field($H_k$) of 17 Oe and $4\piM_5$ of 1.0 T were obtained by this method.

  • PDF

A Coupled Circuit and Field Analysis of a Stand-Alone Permanent-Magnet Synchronous Generator with Inset Rotor

  • Chan T. F.;Yan Lie-Tong;Lai L. L.
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.3
    • /
    • pp.253-257
    • /
    • 2005
  • By using a coupled circuit, time-stepping, two-dimensional finite element method (2-D FEM), the performance of a stand-alone permanent-magnet synchronous generator (PMSG) with inset rotor can be computed without involving the classical two-axis model. The effects of interpolar air gap length and armature resistance on the load characteristics are investigated. It is shown that the interpolar flux density, and hence the amount of voltage compensation, is affected by magnetic saturation. Validity of the coupled circuit and field analysis is confirmed by experiments on a prototype generator. The machine exhibits an approximately level load characteristic when it is supplying an isolated unity-power-factor load.

Evaluation of Selective Saturation and Refocousing Pulses in Chemical Shift NMR Imaging

  • Shin, Yong-Jin;Park, Young-Sik
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.4 no.1
    • /
    • pp.64-73
    • /
    • 2000
  • There are several methods to achieve selective NMR image of differing chemical species with the three most popular methods of Dixon's, CHESS, and SECSI. A major problem common to all chemical shift imaging methods is the uniformity of the static magnetic field and distortions introduced when RF coils are loaded with a conducting specimen. Without magnetic field shimming, these methods cannot be used to acquire selectively image protons in fat and water which are separated by approximately 3.0ppm. Experiments with a phantom, with linewidths of 2.5 to 3.5ppm, were quantitatively evaluated for the three methods and a new chemical shift imaging method. In this study the new chemical shift imaging method (modified CHESS+SECSI technique) which included a selective saturation and refocusing pulse, was developed to determine the ratios of water and fat in different samples.

  • PDF

Analytical Thermal Noise Model of Deep-submicron MOSFETs

  • Shin, Hyung-Cheol;Kim, Se-Young;Jeon, Jong-Wook
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.6 no.3
    • /
    • pp.206-209
    • /
    • 2006
  • This paper presents an analytical noise model for the drain thermal noise, the induced gate noise, and their correlation coefficient in deep-submicron MOSFETs, which is valid in both linear region and saturation region. The impedance field method was used to calculate the external drain thermal noise current. The effect of channel length modulation was included in the analytical equation. The noise behavior of MOSFETs with decreasing channel length was successfully predicted from our model.

Finite Element Method using Complex Harmonics for analyzing saturation characteristics (포화 특성 해석을 위한 복소 고조파 유한 요소해석법)

  • Chung, Yong-Seek;Park, Gwan-Soo;Hahn, Song-Yop
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.11-14
    • /
    • 1990
  • The Complex Harmonic Balance Finite Element Method CHBFEM ) is dicussed for the time - periodic magnetic field with saturation characteristics. And Jw - method which is used for analyzing liner system with sinusoidal voltage input can be generalized in nonlinear time-periodic magnetio field system. The CHBFEM enables us to calculate the each harmonic magnetic flux ditribution and the distortion of currents resulting from material at an AC voltage source and to save calculating time, the number of calculation and computer memory.

  • PDF

A Study on the Occurrence Cause of the Zero Sequence Voltage at Tertiary Side of 345[kV] Main Transformer (345[kV] 주변압기 3차측 영상전압 발생원인 분석 및 대책에 관한 연구)

  • Woo, Jung-Wook;Kweon, Dong-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.150-158
    • /
    • 2010
  • We had experienced the several system failures which were concerned about zero sequence voltages at the tertiary side of 345[kV] transformers. In this paper, we had considered the zero sequence voltage and its reduction methods at the 345[kV] auto-transformer tertiary. For analysis, we used EMTP(Electro-Magnetic Transients Program). The calculation results by EMTP were compared with the measured data of the field tests. From the calculation and the field tests, we had verified that it is due to pre-saturation characteristics of the potential transformer. So, we had improved its saturation characteristics and applied it at real site. After improvements, we could reduce the zero sequence voltage below the setting level of the relay.