• 제목/요약/키워드: Saturated Vapor Property

검색결과 10건 처리시간 0.024초

냉매의 포화증기밀도 상관식 비교 (Comparison of Correlations of Saturated Vapor Density for Some Refrigerants)

  • 박경근;강병하;장시열
    • 설비공학논문집
    • /
    • 제19권6호
    • /
    • pp.457-463
    • /
    • 2007
  • Various correlations of saturated vapor density in a truncated power series form are tested and compared in this study. Saturated vapor density correlation can be expressed relating logarithmic reduced density to the reduced temperature. Five types of correlation has been investigated using saturated vapor density data for 22 pure substance refrigerants from ASHRAE (American Society of Heating, Reftigerating and Air-Conditioning Engineers, Inc.) property tables and NIST (National Institute of Standards and Technology) Chemistry Webbook. Correlations are fitted to the data points by least squares method. Data points are equally weighted. The best type of correlation among the five types is suggested. The results obtained indicate that the best correlations with 3, 4, and 5 terms yield average AAD's (Average Absolute Deviation) of 0.27%, 0.04%, and 0.02%, respectively, while widely used conventional correlations with 3, 4, and 5 terms yield those of 1.19%, 0.61%, and 0.17%. The suggested type of correlation could reduce the number of terms while improving performance.

두 개의 온도 의존 매개변수가 있는 3차 상태방정식의 성능비교 (Performance Comparison of Cubic Equations of State With Two Temperature Dependent Parameters)

  • 권영욱;박경근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.205-210
    • /
    • 2001
  • Cubic equations of state with two temperature dependent parameters are suggested and optimized using ASHRAE data for methane, propane, carbon dioxide, R-32 and R-134a. Appropriate simple functional forms are assumed for the temperature dependent parameters. The equations tested are Martin, Fuller, Harmens-Knapp, Schmidt-Wenzel. Among them modified Schmidt-Wenzel equation of state appears to be the choice for calculation of saturation properties such as vapor pressures, saturated liquid volumes, and saturated vapor volumes with an average absolute deviation of about one percent over the entire region excluding; the near cirtical.

  • PDF

신경회로망을 사용한 냉매의 함수근사 (Function Approximation for Refrigerant Using the Neural Networks)

  • 박진현;이태환
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 추계종합학술대회
    • /
    • pp.677-680
    • /
    • 2005
  • 유체의 상변화를 이용하는 냉난방장치 등의 열장치에 대한 열역학적인 성능평가는 열역학적 성질들에 대한 구체적인 수치값을 필요로 한다. 그러나 이러한 열역학적 성질들을 제공하는 증기표를 그대로는 사용할 수 없기 때문에 효과적인 모델링이 필요하다. 본 연구에서는 신경회로망의 함수근사 특성을 이용하여 냉방장치의 매질로 사용되는 냉매(R12)의 포화증기 영역을 모델링하였다. 냉매 R12의 포화증기 영역의 함수근사 해석을 위하여 1개의 노드를 가진 입력층에 대하여 7개의 노드를 가진 출력층을 기본으로 하여, 각각 10개와 20개의 노드를 가진 두 개의 은닉층을 가진 회로망을 구성하였다. 또한 입력이 온도와 압력 두 가지의 경우에 대하여 검토하였다. 제안된 신경회로망을 사용한 결과 엔탈피, 엔트로피의 백분율오차가 대부분 ${\pm}$0.005%, 비체적은 ${\pm}$0.02%, 압력과 온도는 특별한 몇 개를 제외하고는 ${\pm}$0.02% 범위 내로 수렴되었다. 이 결과로부터 냉매를 함수근사하는데 있어서 신경회로망이 아주 강력한 수단이 될 수 있음을 확인하였다.

  • PDF

수치모델에서 레이더 자료동화가 강수 예측에 미치는 영향 (The Effect of Radar Data Assimilation in Numerical Models on Precipitation Forecasting)

  • 이지원;민기홍
    • 대기
    • /
    • 제33권5호
    • /
    • pp.457-475
    • /
    • 2023
  • Accurately predicting localized heavy rainfall is challenging without high-resolution mesoscale cloud information in the numerical model's initial field, as precipitation intensity and amount vary significantly across regions. In the Korean Peninsula, the radar observation network covers the entire country, providing high-resolution data on hydrometeors which is suitable for data assimilation (DA). During the pre-processing stage, radar reflectivity is classified into hydrometeors (e.g., rain, snow, graupel) using the background temperature field. The mixing ratio of each hydrometeor is converted and inputted into a numerical model. Moreover, assimilating saturated water vapor mixing ratio and decomposing radar radial velocity into a three-dimensional wind vector improves the atmospheric dynamic field. This study presents radar DA experiments using a numerical prediction model to enhance the wind, water vapor, and hydrometeor mixing ratio information. The impact of radar DA on precipitation prediction is analyzed separately for each radar component. Assimilating radial velocity improves the dynamic field, while assimilating hydrometeor mixing ratio reduces the spin-up period in cloud microphysical processes, simulating initial precipitation growth. Assimilating water vapor mixing ratio further captures a moist atmospheric environment, maintaining continuous growth of hydrometeors, resulting in concentrated heavy rainfall. Overall, the radar DA experiment showed a 32.78% improvement in precipitation forecast accuracy compared to experiments without DA across four cases. Further research in related fields is necessary to improve predictions of mesoscale heavy rainfall in South Korea, mitigating its impact on human life and property.

물 분무를 이용한 연소가스 냉각 1차원 해석 (1-D Analysis for Water Spray Cooling of Exhaust Gas in Combustor Test Facility)

  • 임주현;김명호;김용련
    • 한국추진공학회지
    • /
    • 제19권1호
    • /
    • pp.61-67
    • /
    • 2015
  • 연소기 시험 장치의 구축 시 고온의 연소 가스의 냉각은 중요한 설계요구조건이다. 물 분무(Water spray) 냉각 방식은 증발 과정에서 물의 잠열을 이용하므로, 효과적인 연소 가스 냉각이 가능하다. 본 연구에서는 연소기 시험 설비 구축 과정의 일환으로, 물 분무를 이용한 연소 가스의 냉각을 이해하기 위하여 연속방정식, 에너지 보존식과 포화 증기의 압력-온도 관계식을 이용한 1차원 해석을 수행하였다. 연소기 시험 장치에서 배출되는 고온, 고압의 연소 가스는 냉각수와의 혼합과정에서 배출가스의 온도가 낮아지며, 분무된 물의 일부는 기화하여 연소가스와 함께 배출되고, 일부는 다시 응축 되어 집수조로 모인다. 냉각수는 연소 가스의 온도를 낮춰주는 동시에, 증발된 증기는 연소기 내부의 압력을 증가시키므로 1차원 해석에서 증기의 압력-온도 관계식을 고려하여 해석을 수행하였다. 1차원 해석으로부터 연소가스의 적절한 냉각과 배기 덕트 내부의 압력의 지나친 상승을 피하기 위한 최적의 물 분무량을 확인하였으며, 물 분무 냉각 방식에 대한 물리적 이해를 얻을 수 있었다.

수평평판의 막응축에서 전도 열저항의 영향 (The Effect of Heat Conduction resistance on Laminar Film Condensation along a Horizontal Plate)

  • 이억수
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.183-188
    • /
    • 2005
  • The effect of heat conduction resistance on laminar film condensation of the pure saturated vapor in forced flow over a flat plate has been investigated as boundary layer solutions. A efficient numerical methods for water are proposed for its solution. The momentum and energy balance equations are reduced to a nonlinear system of ordinary differential equations with four parameters: the Prandtl number, Pr, Modified Jacob number, $Ja^{\ast}/Pr$, defined by an overall temperature difference, a property ratio $\sqrt{P_l{\mu}_l/P_v{\mu}_v}$ and the conjugate parameter ${\zeta}$. The similarity and simplified solutions obtained reveal the effects of the conjugate parameter.

  • PDF

Similarity and Approximate Solutions of Laminar Film Condensation on a Flat Plate

  • Lee, Sung-Hong;Lee, Euk-Soo
    • Journal of Mechanical Science and Technology
    • /
    • 제15권9호
    • /
    • pp.1339-1345
    • /
    • 2001
  • Laminar film condensation of a saturated pure vapor in forced flow over a flat plate is analyzed as boundary layer solutions. Similarity solutions for some real fluids are presented as a function of modified Jakob number (C$\_$pι/ ΔΤ/Prh$\_$fg/) with property ratio (No Abstract.see full/text) and Pγ as parameters and compared with approximate solutions which were obtained from energy and momentum equations without convection and inertia terms in liquid flow. Approximate solutions agree well with the similarity solutions when the values of modified Jakob number are less then 0.1 near 1 atmospheric pressure.

  • PDF

수평평판에서 복합 층류 막응축에 대한 연구 (A Study of Conjugate Laminar Film Condensation on a Flat Plate)

  • 이억수
    • 설비공학논문집
    • /
    • 제17권4호
    • /
    • pp.303-311
    • /
    • 2005
  • The problem of conjugate laminar film condensation of the pure saturated vapor in forced flow over a flat plate has been investigated as boundary layer solutions. A simple and efficient numerical method is proposed for its solution. The interfacial temperature is obtained as a root of 3rd order polynomial for laminar film condensation, and it is presented as a function of the conjugate parameter. The momentum and energy balance equations are reduced to a nonlinear system of ordinary differential equations with four parameters: the Prandtl number, Pr, Jacob number, $Ja^{\ast}$, defined by an overall temperature difference, a property ratio R and the conjugate parameter ${\zeta}$. The approximate solutions thus obtained reveal the effects of the conjugate parameter.

Water Repellency on a Nanostructured Superhydrophobic Carbon Fibers Network

  • Ko, Tae-Jun;Her, Eun-Kyu;Shin, Bong-Su;Kim, Ho-Young;Lee, Kwang-Ryeol;Hong, Bo-Ki;Kim, Sae-Hoon;Oh, Kyu-Hwan;Moon, Myoung-Woon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.224-224
    • /
    • 2012
  • For decades, carbon fiber has expanded their application fields from reinforced composites to energy storage and transfer technologies such as electrodes for super-capacitors and lithium ion batteries and gas diffusion layers for proton exchange membrane fuel cell. Especially in fuel cell, water repellency of gas diffusion layer has become very important property for preventing flooding which is induced by condensed water could damage the fuel cell performance. In this work, we fabricated superhydrophobic network of carbon fiber with high aspect ratio hair-like nanostructure by preferential oxygen plasma etching. Superhydrophobic carbon fiber surfaces were achieved by hydrophobic material coating with a siloxane-based hydrocarbon film, which increased the water contact angle from $147^{\circ}$ to $163^{\circ}$ and decreased the contact angle hysteresis from $71^{\circ}$ to below $5^{\circ}$, sufficient to cause droplet roll-off from the surface in millimeter scale water droplet deposition test. Also, we have explored that the condensation behavior (nucleation and growth) of water droplet on the superhydrophobic carbon fiber were significantly retarded due to the high-aspect-ratio nanostructures under super-saturated vapor conditions. It is implied that superhydrophobic carbon fiber can provide a passage for vapor or gas flow in wet environments such as a gas diffusion layer requiring the effective water removal in the operation of proton exchange membrane fuel cell. Moreover, such nanostructuring of carbon-based materials can be extended to carbon fiber, carbon black or carbon films for applications as a cathode in lithium batteries or carbon fiber composites.

  • PDF

신냉매 R1234yf의 외부 응축 열전달계수 (External Condensation Heat Transfer Coefficients of R1234yf)

  • 박기정;이철희;강동규;정동수
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.345-352
    • /
    • 2010
  • In this study, external condensation heat transfer coefficients(HTCs) of R134a and R1234yf are measured on a plain, low fin, and Turbo-C tubes at the saturated vapor temperature of $39^{\circ}C$ with the wall subcooling of $3{\sim}8^{\circ}C$. R1234yf is a new alternative refrigerant of low greenhouse warming potential for replacing R134a which is one of the greenhouse gases controlled by Kyoto protocol and is used extensively in mobile air-conditioners. Test results show that the external condensation HTCs of R1234yf are very similar to those of R134a for all three surfaces tested. For the application of condensation heat transfer correlations to the design of condensers charged with R1234yf, thorough property measurements are needed for R1234yf in the near future.