• 제목/요약/키워드: Saturable Reactor

검색결과 11건 처리시간 0.027초

대전력 SCR 초퍼에서 가포하리액터-저항짝의 효과 (A Effect of Saturable Reactor-Resistor Pair on High Power SCR Chopper)

  • 강민구;조규형
    • 대한전기학회논문지
    • /
    • 제37권7호
    • /
    • pp.442-447
    • /
    • 1988
  • Saturable reactor-resistor pair is proposed as a part of snubber and applied to a hard commutation chopper. SCR turn off process is modeled to simulate the hard commutation chopper. State equations are derived for each mode of the chopper and they are solved by Runge-Kutta 4th order method. It is shown that the reverse voltage spike and reverse dv/dt can be minimized by applying saturable reactor-resistor pair to the chopper which controls peak reverse recovery current and damping factor. Saturable reactor-resistor pair can be used to reduced SCR power loss and value of snubber capacitor and can be applied to high power thyristor devices.

  • PDF

Study on EMTP Simulation Applying Dual Reactor for Prevention of the Ferro-resonance and VT Burnout in Substation System

  • Kim, Seok-kon;An, Yong-ho;Jang, Byung-tae;Choi, Jong-kee;Lee, Nam-ho;Han, Jung-yeol;Lee, You-jin
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.1-8
    • /
    • 2015
  • When the line and switchgear of the substation system are disconnected, ferro-resonance can occur. This happens even if the capacitive reactance and inductive reactance are not equal, which are not common resonance conditions. Resonance conditions vary depending on the busbar configuration environment. Although the damping resistance method applying the existing saturable reactor to cope with ferro-resonance has been successfully applied on site, there can be loss of normal function during long-term operation. The reason is because the rise in the operating frequency of saturable reactors means the saturation number is increased. Therefore, it can no longer function as saturable reactor since the resistor having inadequate capacity is burned out. To address this problem, in this paper, an EMTP-based simulation test was performed by designing and applying a dual reactor method, which adds an extended divergence reactor to the 1st side of the VT. The test result confirms that when the divergence reactor is inserted, the voltage and current values obtained at the 1st side and 2nd side of the VT as well as current values of divergence reactor part were stabilized from the transient phenomena and return to normal values. When compared with existing measures, although this method is similar in adding having a reactor added to a system regarding ferro-resonance, it has the advantage of being able to prevent ferro-resonance in advance since the reactor is added before the system is saturated. In addition, because it does not use damping resistance, it can extend the equipment life and stabilize its operation. Therefore, there are a lot of differences in terms of its operating characteristics and achivement of goal between the conventional method and new divergence reactor method.

자기 포화형 고온 초전도 한류기의 구조 및 단락특성에 관한 연구 (The Structure and Short Circuit Analysis of Saturable Magnetic Core Superconducting Fault Current Limiter)

  • 최석진;이승제;이찬주;이상진;현옥배;고태국
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.154-157
    • /
    • 2000
  • Superconducting tape easily can applied to distribution of electricity. It designs basic model of Saturable Reactor type Fault Current Limiter which used superconducting tape, and observes a specific character by means of simulation. Saturable Reactor type Fault Current Limiter is not influenced by saturation of Magnet core appeared in Induction Fault Current Limiter, because it exploit saturation of Iron core. But, it is possible that superconducting tape quenched when AC current flow to superconducting tape which biased DC voltage.

  • PDF

EMTP를 이용한 362kV Gas VT의 철공진제거를 위한 가포화리엑터의 파라미터 선정 (Parameter Selection of the Saturable Reactor for Removing Ferroresonance of 362kV Gas VT Using EMTP)

  • 최재구;김익수;박경원;송희석
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권4호
    • /
    • pp.197-203
    • /
    • 2001
  • Recently, the construction of gas insulated substation(GIS)s has been increased in Korea. But, the whole quantity of the VTs which were used in GIS has been imported. Under the circumstance that $SF_6$ gas power apparatus are being developed up to 800kV rating in Korea, the development of EHV $SF_6$ gas VT is essential for localizing the power apparatus. As for EHV VT, destructive ferroresonance can be generated due to the combination of capacitiances between poles of circuit breaker, ground capacitance of bus and nonlinear excitation property of VT core. But the theoretical analysis about ferroresonance has not been fully achieved in Korea. Therefore, in this paper the authors would like to contribute for localizing EHV $SF_6$ gas VT by developing the diagram of ferroresonance zone according to the parameters of the circuit and the saturable reactor.

  • PDF

자기증폭기의 시형설계 및 동작특성 (Design and Characteristics of Magnetic Amplifier)

  • 현경호;오명환;이광원
    • 전기의세계
    • /
    • 제20권3호
    • /
    • pp.17-26
    • /
    • 1971
  • An experimental design of magnetic amplifiers and their characteristics in steady state are presented. A saturable reactor model having 2KVA capacity was designed, using Z-10 grain-oriented silicon steel which is commonly used in power transformers. Experimental and theoretical analysis show that the experimental results are in good agreement with the equal ampere-turns law. In addition to the saturable reactor, the self-saturated magnetic amplifiers of 0.4VA and 5VA capacity, using 50% Ni-Fe alloy cores having rectangular hysteresis loops were designed. Control characteristic curves of these amplifiers show high ampere-turn gain enough to be used for voltage controllers under load and non-contact magnetic switches of the rated capacity.

  • PDF

저 도통손실 특성을 갖는 향상된 영전압 부분 직렬 공진형 DC/DC 컨버터 (An Improved ZVS Partial Series Resonant DC/DC Converter with Low Conduction Losses)

  • 김의성;이동윤;현동석
    • 전력전자학회논문지
    • /
    • 제5권4호
    • /
    • pp.386-393
    • /
    • 2000
  • 본 논문에서는 고전력, 고주파 응용에 적합한 저 도통손실 특성을 갖는 향상된 양전압 부분 직렬 공진행 DC/DC 컨버터를 제안한다. 제안된 컨버터는 많은 범위에서 주 스위치의 영전압 스위칭을 보장히며 주 스위치의 전류 스트레스 감소에 의해 저도통 손실 특성올 이룬다. 또한 제안된 컨버터의 보조회로는 주 전력 흐름과 분리되어 있어 주 회로의 공진 시간동안 유효 듀티비 감소는 발생하지 않는다. 보조 회로는 인덕터, 커피시터, 다이오드 그리고 과포화 리엑터의 수동 소자들만으로 구성 되어있다. 따라서 향상된 ZVS PSRC는 전체 시스템의 효율과 전류 스트레스 감소면 에서 개선된 특성을 지닌다. 제안한 컨버터의 동작 원리를 자세히 설명하고 그 타당성올 시뮬레이션과 실험을 통하여 검증하고자 한다.

  • PDF

새로운 액티브 스너버를 이용한 소프트 스위칭 PWM 컨버터 (Soft Switching PWM Converter Using a New Active Snubber)

  • 조만철;김주용;문상필;서기영;권순걸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.261-263
    • /
    • 2006
  • A new soft switched active snubber circuit is proposed to achieve zero voltage and zero current switching for all the switching devices in PWM DC-DC converters. The unique location of the snubber and inductor ensures low current/voltage stresses and commutation losses. With a saturable reactor, the conduction loss of auxiliary switch could be further minimized. A boost converter adopting this technique is presented as an example, to illuminate its operation principles and derive the design procedures. Simulation and hardware implementation have been made to validate its performance. Some other basic PWM DC-DC topologies using the proposed snubber have also been given.

  • PDF

대용량 GTO 구동회로용 Power Supply Unit 개발 (Development of Power Supply Unit for high power GTO driver)

  • 차재덕;양항준;홍순욱;이학성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.609-612
    • /
    • 1996
  • This paper describes a design and implementation of the practical SMPS(Switched Mode Power Supply) with multi-output independent regulation scheme. The designed SMPS is applied to the PSU(Power Supply Unit) of high power GTO drivers for a inverter system. In order to accomplish precise voltage regulations for both turn-on and turn-off bias voltages of the GTO driver, the conventional forward type PWM converter scheme is adopted with the Post Regulator using a Saturable Reactor. Analytic design criteria and control schemes are described for practical applications. Finally, the precise regulation of multi-output voltages is proved by experimental results.

  • PDF

새로운 액티브 스너버를 이용한 고주파 PWM DC-DC 컨버터의 토플로지 (Topologies of hige freguency PWM DC-DC converter using a new active snubber)

  • 조만철;김칠용;서기영;이현우;권순걸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1010-1011
    • /
    • 2006
  • A new soft switched active snubber circuit is proposed to achieve zero voltage and zero current switching for all the switching devices in PWM DC-DC converters. The unique location of the snubber capacitor and inductor ensures low current/voltage stresses and commutation losses. With a saturable reactor, the conduction loss of the auxiliary switch could be further minimized. A boost converter adopting this technique is presented as an example, to illuminate its operation principles and derive the design procedures. Simulation and hardware implementation have been made to validate its performance. Some other basic PWM DC-DC topologies using the proposed snubber have also been given.

  • PDF

대전력 응용을 위한 새로운 ZVZCS PWM 컨버어터 (New ZVZCS PWM Converter For High Power Application)

  • 류홍제;조정구;유동욱;임근희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.521-524
    • /
    • 1996
  • A new zero voltage and nero current switching(ZVZCS) full bridge(FB) PWM converter b proposed to improve the performance of the previously presented ZVZCS-FB-PWM converters [7,8]. By adding a secondary active clamp and controlling the clamp switch moderately, ZVS(for leading-leg switches) are ZCS(for lagging-leg switches) are achieved without nay lossy components, the reverie avalanche break down of leading-leg IGBTs[7] or the saturable reactor in the primary[8]. Many advantages including simple circuit topology, high efficiency, and low cost mate the new converter attractive for high voltage and high power(> 10 kW) applications. The principle of operation is explained and analyzed. The features and design considerations of the new converter are also illustrated and verified on an 1.8 kW, 100 kHz IGBT based experimental circuit.

  • PDF