Objectives: This study was carried out to investigate the characteristics of odors emitted from sewage in a sanitary sewer and its outlets. Methods: The concentration of mal-odorous sulfur was analyzed by gas chromatograph, and odor intensity was estimated by an on-site sensory test. Odor intensity calculated from instrumental analysis results was compared with odor intensity observed at field. Results: As a results, the concentration of $H_2S$ ranged from 2.4 ppb to 5,889 ppb (average 703 ppb), while $CH_3SH$, $(CH_3)_2S$, and $(CH_3)_2S_2$ showed from 10 ppb to 554 ppb (average 119 ppb) and from 20 ppb to 332 ppb (average 70 ppb) and from 2.7 ppb to 8.1 ppb (average 5 ppb) individually. Average odor intensity observed in the field was degree three. Odor intensity calculated from sulfur compound concentration was confirmed as similar to the observed odor intensity because the coefficient of variance between the observed and the calculated intensities was less than one. Conclusion: It was expected that the results of this study will be helpful to design a deodorizing device to reduce odor emissions from sewerage facilities in the future.
This study is on the space planning of accommodation area in accommodation barge, which is a kind of offshore plant supply vessel providing workers with exclusive accommodation facilities. Firstly, the space layout of accommodation area is analyzed using the general arrangement drawings of 10 actually-built accommodation barges currently in use. Secondary, the design guides and standards for living quarters of offshore plants issued from overseas classification societies such as ABS, NORSOK etc. are analyzed and based on the analysis design guidelines for accommodation area of accommodation barge are newly suggested. Thirdly, a model of accommodation area in accommodation barge is set up and space arrangements and movement lines for each deck of the accommodation area of the model are planned. Fourthly, cabins, dinning room and galley, recreation spaces, and sanitary spaces of the accommodation area of the model are planned. The results of this study may be summarized as follows. An accommodation barge has 'barge deck' for small scale work and material storage, and 'accommodation area' for the living and resting of workers. The accommodation area is made of workers accommodation sector, service sector, crew sector and business sector. The interior design guidelines for accommodation area of accommodation barge should be made soon by Korea Register of Shipping.
Although the improvements in the health sanitary facilities of the elementary school were made by the implementation of the 7th curriculum, color design and concept of toilets used by lower classes students were shown to be still insufficient and so, it is also necessary to have color planning for toilets considering users' preferences. This study is targeting lower classes children of elementary schools under Seoul Gangseo Office of Education. The purpose of this study is to propose a toilet color design direction preferred by children as users. Therefore, the toilets of elementary school were investigated and at the same time, juvenile pictures were analyzed. The results of this study are that the color space used in the current design, the following gives a substantial psychological and emotional impact for many elementary school children in the developmental stages of children leads to an interesting use of color. Therefore, this study propose to improve the toilet to a more familiar environment with high accessibility considering the development of the child when using color in design space through color preference.
This study carried out a survey of students in Gangwon province's general opinion and satisfaction with the school food-service programs implemented in Gangwon province. The method involved a survey of 1,500 elementary, middle, and high school students from 30 schools. The main results of this study can be summarized as follows: With regards to their general opinion of the school food-service programs, $70\%$ of the students answered that the size of the portions was appropriate. Moreover, the survey students answered that they were satisfied with the current method in which the food services. The elementary school students were found to be the best at maintaining public order when the food services were being conducted. The largest complaint which the students had towards these food service programs was the taste of the food itself. With regard to the students' degree of satisfaction with the school food service programs, the highest level of satisfaction with the atmosphere during meal times(3.88), followed by the degree of satisfaction with the food(3.27), and the school cafeteria environment(3.20), and the sanitary conditions of the food service facilities(3.14). The overall opinion and degree of satisfaction with school food service programs demonstrated significant differences, depending on the school level and type of food service.
Sludge production from water treatment plants is increasing each year because water resources deterioration is proceeding and water supply facilities are growing due to water demand increase. Water treatment plant sludges can be modified to soil cover in sanitary landfilling site through the lime treatment and other alternatives. The compression strength of $1.0kg/cm^2$ is necessary for the dozer operation on soft son cover material at municipal landfilling site. Modified sludge was experimentally produced in this study with lime, bentonite, loess, and activated loess dosing. X-ray diffraction patterns of the limed water treatment plant sludge confirmed the presence of calcium carbonate and ettringite. Unconfined compression strength properties of modified sludges showed material property improvement applicable for soil cover alternatives. When adding 20-30% activated loess to water treatment plant sludges. the modified sludges could reach the compression strength for cover soil after 7 days solidification reaction, but decrease of compression strength was intentioned in 28 days reaction period. Solidification effect of the modified sludge with activated loess was observed through the scanning electron microscope.
A study was carried out to find out the biological contamination of beaches in Korea from May 16, to June 2, 1972. Turbidity was measured and coliform groups were examined by membrane filter method as well as general sanitary condition of beaches. Main findings were as follows: 1. The average coliform group count was 5.0 per 100 ml of tested water, and the range of coliform. group count was 0~120 out of 8 beaches, Chungmun beach was found to be the least contaminated while Daechun was the most contaminated (23. 3/100 ml), however, those beaches surveyed. were satisfactory as far as bacteriological contaminations were concerned. 2. The average coliform group count of water samples from rising tides was 2.8/100 ml. The range of coliform count from rising tide was 0~26/100 ml, and those from receding were 1~120/100 ml. 3. The average turbidity of the water in Korean western beaches was 5.0 ppm, while that of Chejudo was 2.0 ppm. of 8 beaches surveyed, the turbidity of Daechon beach was the highest (7.0 ppm). 4. Out of 8 beaches surveyed shower facilities existed at only 4 beaches (50%), however the drainages of showers and bath rooms were not sanitarily adequate.
Journal of The Korea Institute of Healthcare Architecture
/
v.3
no.4
/
pp.59-68
/
1997
This study is intended to review the Nucleus System of standard hospitals in U.K. The research is focused on the theoretical background, contents of Nucleus System, and the operational problems through the survey of sample hospitals. The contents of research include the development history of standardization, outlines, aimes, advantages, the data of Nucleus system, and the study-visits of sample hospitals. The conclusion could be summarized as follows ; 1) The form of standard hospitals is compact and low-rise the major movements are horizontal. The standard plans of the functional dpartments are unified as cruciform with $15m{\times}15m$ module. 2) The Nulceus System has been developed. The hospitals have 3 stories maximum and courtyards for natural light & ventilation. 3) The advantages of Nucleus System includes reduction of design & construction period, the buildability due to the repetitive construction, and the running cost. And the disadvantages are mentioned as the lack of storage, staff accomodation, pantry, and sanitary facilities. 4) Sample hospitals provide human scale, possibilities of growth & change, and curing environment from art decoration & artificial lake. 5) In case of Korean situation, even the minimum standardization such as hospital design guidelines should be developed in near future.
In this study, the hygiene control status of meals for the elderly was investigated for the elderly care facilities, communal living families, and day care centers, which are members of the Cheongju Social Welfare Food Management Support Center, and the improvement of food hygiene management was compared and analyzed to find out the effectiveness of the pilot project after conducting management support such as hygiene education for the elderly and providing related supplies and information. The study found that after the first support, the average score of overall feeding hygiene control increased significantly from 63.13 points (out of 100) to 75.10 points (p<0.001) and from 75.10 points (out of 100) to 80.89 points (p<0.001). After primary support, 16 out of 29 items showed significant differences in average scores in the checklist, and 7 out of 29 after secondary visit support (p<0.05, p<0.01, p<0.001). Based on the effectiveness of the above-mentioned pilot project to support senior citizens' meal service management, more welfare facilities for senior citizens should be continuously supported by the Foodservice Management Support Center.
This survey was carried out for a month from Jan. 15th, 1979 to Feb, 15th, 1979 to study the sanitary environments of the "book-lending" shops (comic-book shops) in Inchon area, and the special emphasis was placed on their illumination and carbon monoxide gas, which plays an important part in the whole sanitary environment. 120 shops surveyed were chosen at random from 4 administrative districts, 30 shops from one district respectively. The results of the survey were as follows:1) The average space of the book-lending shops (63.3%) was 2.0~3.9 pyung, at 21 number of shops (17.5%) was 1.0~1.9 pyung, at 53 number of shops (10.8%) was 4.0~5.9 pyung, at 9 number of shops (7.5%) was 6.0~7.9 pyung. 2) The ages of 42.8 percent of the whole 888 customers range from 10 to 14 and those of 36.5 percent from 15 to 19, and those of 11.9 percent from 20 to 24, and 89.2 percent were male and 10.8 percent were females and the percent of spending time in shops was shown 10.2% in under 1 hr, 25.4% in 1 hr to 2 hrs, 46.5% in 2 hrs to 3 hrs and 17.8% in over 3 hrs. 3)The CO pollution was quite different by shops where the ventilator was equipped and where not equipped. In the shops equipped shown 36 shops (80.8%) and non-equipped shown 65 shops (86.7%), the pollution ratio of all the shops (120 shops) was 84.2 percent. 4) The CO Concentration of the ventilator equipped shops was shown 44.5 percent in 100~149 ppm, 150~199 ppm shown 33.3 percent and 22.2 percent was 200~250 ppm, In the non-equipped shops the CO concentration was shown 36.9 percent was 150~199 ppm and 200~250 ppm was 25.6 percent. The totally was 39.6 percent in 100~149 ppm. 5) 37.5 percent of the book-lending shops had the ventilation facilities but 62.6 percent had no ventilators. 6) The maxmum average illumination of the shops was 38.5 Lux and the minimum average illumination was 14.1 Lux, and the mean average illumination S.D. was 24.6\pm38.4. 7) 35.8 percent of the shops had the illumination of 20~29 Lux and 8.3 percent had that of more than 40 Lux. In other words 91.7 percent had the illumination of less than 40 Lux.
The incineration process has commonly used for wastes amount reduction and thermal treatments of pollutants as the technologies accumulated. However, the process is getting negative public images owing to matter of hazardous pollutants emission. Specially dioxins became a main issue and were mostly emitted from municipal solid wastes incineration. In this reason, pyrolysis/gasification/melting process is presented as an alternative of incineration process. The pyrolysis/gasification/melting process, a novel technology, is middle of verification of commercial plant and development of technologies in Korea. But the survey about the pollutant emission from the process, and background data in these facilities is necessary. So in this survey, t is investigated that the behavior of chlorobenzenes and chlorophenols in plasma type pyrolysis/gasification/melting plant of pilot scale. We investigated discharging behavior of each phase of chlorobenzene through each process in the plsasma type pyrolysis/gasification/melting process. From this result, it was found that about 99 percent of particle-phase chlorobenzene was removed, but on the other hand gas-phase chlorobenzene was increased by about 600 percent through heat exchanger, flue gas cooling, system and semi dry absorption bag filter(SDA/BF). Also, this investigation presented that di-chlorobenzene(DCB) tri-chlorobenzene(TCB), tetra-chlorobenzene(TeCB), penta-chlorobenzene (PCB), except mono-chlorobenzene(MCB) and hexa-chlorobenzene(HCB) were increased through the flue gas cooling system and the semi dry absorption bag filter(SDA/BF). It was investigated that concentration of particle-phase chlorophenol was decreased by about 66 percent, but on the other hand, concentration of gas-phase chlorophenol was increased by about 170 percent through heat exchanger, flue gas cooling system, and semi dry absorption bag filter(SDA/BF). Also, it was found that di-chlorophenol(DCP), tri-chlorophenol(TCP), and penta-chlorophenol(PCP) were increased through the flue gas cooling system, and the semi dry absorption bag filter(SDA/BF). It can be considered that small-scale pilot facility and short investigation period might cause the concentration increase through the flue gas cooling system and the semi dry absorption bag filter(SDA/BF). A further study on real-scale pilot facility and accurate investigation may be required.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.